Keyu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Keyu Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Fei Wang
School of Chemical Engineering and Dyeing & Printing Engineering, Henan University of Engineering, Zhengzhou 450007, People’s Republic of China
2 shared publications - Yanju Wu
School of Chemical Engineering and Dyeing Engineering, Henan University of Engineering, Zhengzhou 450007, China
2 shared publications - Baoshan Wang1 shared publication
Fei Wang
Henan Institute of Engineering
1 shared publicationHui Liu
Zhengzhou Normal University
1 shared publication- Junlong Ma1 shared publication
Latest Publications
- Open Access
- 10 December 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (12) , 1024
C-undecylcalix[4]resorcinarene Langmuir–Blodgett/Porous Reduced Graphene Oxide Composite Film as a Electrochemical Sensor for the Determination of Tryptophan
In this study, a composite film was developed for the electrochemical sensing of tryptophan (Trp). Porous reduced graphene oxide (PrGO) was utilized as the electron transfer layer, and a C-undecylcalix[4]resorcinarene Langmuir–Blodgett (CUCR-LB) film served as the molecular recognition layer. Atomic force microscopy (AFM), transmission electron microscopy (TEM), Raman spectroscopy, scanning electron microscopy (SEM), and electrochemical experiments were employed to analyze the characteristics of the CUCR-LB/PrGO composite film. The electrochemical behavior of Trp on the CUCR-LB/PrGO composite film was investigated, revealing a Trp linear response range of 1.0 × 10−7 to 3.0 × 10−5 mol L−1 and a detection limit of 3.0 × 10−8 mol L−1. Furthermore, the developed electroanalytical method successfully determined Trp content in an amino acid injection sample. This study not only introduces a rapid and reliable electrochemical method for the determination of Trp but also presents a new strategy for constructing high-performance electrochemical sensing platforms.
- 10 December 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (12) , 1024
Open AccessC-undecylcalix[4]resorcinarene Langmuir–Blodgett/Porous Reduced Graphene Oxide Composite Film as a Electrochemical Sensor for the Determination of Tryptophan
In this study, a composite film was developed for the electrochemical sensing of tryptophan (Trp). Porous reduced graphene oxide (PrGO) was utilized as the electron transfer layer, and a C-undecylcalix[4]resorcinarene Langmuir–Blodgett (CUCR-LB) film served as the molecular recognition layer. Atomic force microscopy (AFM), transmission electron microscopy (TEM), Raman spectroscopy, scanning electron microscopy (SEM), and electrochemical experiments were employed to analyze the characteristics of the CUCR-LB/PrGO composite film. The electrochemical behavior of Trp on the CUCR-LB/PrGO composite film was investigated, revealing a Trp linear response range of 1.0 × 10−7 to 3.0 × 10−5 mol L−1 and a detection limit of 3.0 × 10−8 mol L−1. Furthermore, the developed electroanalytical method successfully determined Trp content in an amino acid injection sample. This study not only introduces a rapid and reliable electrochemical method for the determination of Trp but also presents a new strategy for constructing high-performance electrochemical sensing platforms.
- Open Access
- 13 October 2023
- Published by MDPI AG in Preprints.org
C-undecylcalix[4]resorcinarene Langmuir-Blodgett/Porous Reduced Graphene Oxide Composite Film as a Electrochemical Sensor for Determination of Tryptophan
In this study, a composite film was developed for electrochemical sensing of tryptophan (Trp). Porous reduced graphene oxide (PrGO) was utilized as the electron transfer layer, and a C-undecylcalix[4] resorcinarene Langmuir-Blodgett (CUCR-LB) film served as the molecular recognition layer. Atomic force microscopy (AFM), transmission electron microscopy (TEM), Raman spectroscopy, scanning electron microscopy (SEM), and electrochemical experiments were employed to analyze the characteristics of the CUCR-LB/PrGO composite film. The electrochemical behavior of Trp on the CUCR-LB/PrGO composite film was investigated, revealing a linear response range of Trp was 1.0×10-7 to 3.0×10-5 mol L-1 and a detection limit of 3.0×10-8 mol L-1. Furthermore, the developed electroanalytical method successfully determined Trp content in an amino acid injection samples. This study not only introduces a rapid and reliable electrochemical method for determination of Trp but also presents a new strategy for constructing high-performance electrochemical sensing platforms.
- 13 October 2023
- Published by MDPI AG in Preprints.org
Open AccessC-undecylcalix[4]resorcinarene Langmuir-Blodgett/Porous Reduced Graphene Oxide Composite Film as a Electrochemical Sensor for Determination of Tryptophan
In this study, a composite film was developed for electrochemical sensing of tryptophan (Trp). Porous reduced graphene oxide (PrGO) was utilized as the electron transfer layer, and a C-undecylcalix[4] resorcinarene Langmuir-Blodgett (CUCR-LB) film served as the molecular recognition layer. Atomic force microscopy (AFM), transmission electron microscopy (TEM), Raman spectroscopy, scanning electron microscopy (SEM), and electrochemical experiments were employed to analyze the characteristics of the CUCR-LB/PrGO composite film. The electrochemical behavior of Trp on the CUCR-LB/PrGO composite film was investigated, revealing a linear response range of Trp was 1.0×10-7 to 3.0×10-5 mol L-1 and a detection limit of 3.0×10-8 mol L-1. Furthermore, the developed electroanalytical method successfully determined Trp content in an amino acid injection samples. This study not only introduces a rapid and reliable electrochemical method for determination of Trp but also presents a new strategy for constructing high-performance electrochemical sensing platforms.
- 12 May 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 16 (10) , 3227-3235
Electrochemical oxidation behavior of methotrexate at DNA/SWCNT/Nafion composite film-modified glassy carbon electrode
- 12 May 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 16 (10) , 3227-3235
Electrochemical oxidation behavior of methotrexate at DNA/SWCNT/Nafion composite film-modified glassy carbon electrode