Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinyuan Yao has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Simulation of Unidirectional Ion Ejection in Miniature Four-Channel Linear Ion Trap Array

    by Yunfan He, Zhuoqing Yang, Yan Zhang, Yunna Sun, Jinyuan Yao, Guifu Ding

    With the surging demand for dynamic, real-time, and rapid qualitative analysis of chemical components, chip-scale mass spectrometers have attracted widespread attention. Ion traps have become the preferred mass analyzer for chip-scale mass spectrometers due to their excellent analytical performance. However, the miniaturization of ion traps inevitably leads to a reduction in ion storage capacity, which in turn affects their sensitivity and dynamic range. In this study, a Miniature Four-Channel Linear Ion Trap Array (M-FLITA) with hyperbolic electrodes and a 1 mm field radius was established and optimized. Concurrently, unidirectional ion ejection was accomplished by the application of asymmetric RF voltages on M-FLITA. The results demonstrate that, in the stretched structure, the mass resolution is improved to 732, while the unidirectional ion ejection efficiency is maintained at 96%. M-FLITA demonstrates advantages in terms of high ion storage capacity and mass resolution under high ion flux conditions, providing an ideal solution for high-performance micro mass analyzers in chip-scale mass spectrometers.

  • Open Access

    Simulation of a Miniature Linear Ion Trap with Half-Round Rod Electrodes

    by Xichi Lu, John T. W. Yeow, Gongyu Jiang, Yu Xiao, Rujiao Yao, Qi Zhang, Jiacheng Song, Jinyuan Yao

    The miniaturization of ion trap mass analyzers is an important direction in the development of mass spectrometers. In this work, we proposed two models of miniaturized HreLIT with a field radius of about 2 mm based on the existing research on conventional HreLIT and other ion traps, one with ions ejection slits on one pair of electrodes only (2-slit model) and the other with the same slits on all electrodes (4-slit model). The relationship of mass resolution with r/rx and the “stretch” distance of electrodes in the ejection direction is investigated by theoretical simulations. Trends of electric fields inside the ion traps were discussed as well. The comparable maximum resolution is observed at r/rx = 2/1.4 in both models, but stretching simulations revealed that the peak resolution of the 2-slit model was higher than that of the other model by about 8%. The highest value of 517 was obtained when stretching 1.1 mm. Furthermore, the resolution of ions with m/z = 119 could exceed 1000 when the scan rate was reduced to 800 Th/s. The mass spectrometry capability of miniature HreLIT has been confirmed theoretically, and it laid the foundation for the subsequent fabrication with MEMS technology.

  • Open Access

    In Situ Sputtering Silver Induction Electrode for Stable and Stretchable Triboelectric Nanogenerators

    by Jinyuan Yao, Qi Zhang, Haodong Zhang, Mengqiu Li, Xichi Lu, Yu Xiao, Rujiao Yao, Xuhong Wang

    Triboelectric nanogenerators (TENG) can convert mechanical energy into electricity and exhibit unique advantages in the field of low-frequency and discrete energy harvesting. However, the interfacial state and stability between the triboelectric layer and electrode layer influence the output and applications of TENG. Herein, an in situ sputtering Ag process for fabricating induction electrodes is proposed to match with TENG. The sputtering Ag process is optimized by a variety of parameters, such as sputtering power, single-cycle time, number of cycles, cycle interval, and vacuum degree. In addition, the chemical state of Ag as a function of air placement is investigated, showing the sputtered Ag has excellent conductivity and stability. Moreover, four kinds of polymers are selected for fabricating TENGs based on the sputtered Ag induction electrodes, i.e., nylon 66, polyimide (PI), fluorinated ethylene propylene (FEP), and polydimethylsiloxane (PDMS), which shows great applicability. Considering the demand of flexible power suppliers, the sputtered Ag is integrated with a PDMS substrate, and shows good adhesion, flexibility, and ductility after severe deformation of the PDMS. Finally, the developed induction electrode processing technology is used in flexible TENG and shows great prospects in self-powered electronics for practical applications.


  • A Single‐Droplet Electricity Generator Achieves an Ultrahigh Output Over 100 V Without Pre‐Charging

    by Qi Zhang, Yahui Li, Han Cai, Mingfang Yao, Haodong Zhang, Linqi Guo, Zhenjie Lv, Mengqiu Li, Xichi Lu, Chao Ren, et al.

    The working principle of the triboelectric nanogenerator (TENG), contact electrification and electrostatic induction, has been used to harvest raindrop energy in recent years. However, the existing research is mainly concentrated on solid–liquid electrification, and adopts traditional electrostatic induction (TEI) for output. As a result, the efficiency of droplet electricity generators (DEGs) is severely constrained. Therefore, previous studies deem that the DEG output is limited by interfacial effects. This study reveals that this view is inappropriate and, in reality, the output strategy is the key bottleneck restricting the DEG performance. Here, a switch effect based on an electric‐double‐layer capacitor (EDLC) is introduced, and an equivalent circuit model is established to understand its working mechanism. Without pre‐charging, a single droplet can generate high voltage over 100 V and the output is directly improved by two‐orders of magnitude compared with TEI, which is precisely utilizing the interfacial effect. This work provides insightful perspective and lays solid foundation for DEG applications in large scale.


  • Open Access

    A Miniature Four-Channel Ion Trap Array Based on Non-silicon MEMS Technology

    by Qi Zhang, Xichi Lu, Ting Chen, Yu Xiao, Rujiao Yao, Jinyuan Yao

    With the increasing application field, a higher requirement is put forward for the mass spectrometer. The reduction in size will inevitably cause a loss of precision; therefore, it is necessary to develop a high-performance miniature mass spectrometer. Based on the researches of rectangular ion trap, the relationship between mass resolution and structural parameters of the ion trap array was analyzed by further simulation. The results indicate that, considering the balance of mass resolution and extraction efficiency, the preferable values for the field radius of exit direction y0 and ion exit slot width s0 are 1.61 mm and 200 μm, respectively. Afterwards, a miniature four-channel ion trap array (MFITA) was fabricated, by using MEMS and laser etching technology, and mass spectrometry experiments were carried out to demonstrate its performance. The mass resolution of butyl diacetate with m/z = 230 can reach 324. In addition, the consistency of four channels is verified within the error tolerance, by analyzing air samples. Our work can prove the correctness of the structural design and the feasibility of MEMS preparation for MFITA, which will bring meaningful guidance for its future development and optimization.


  • Open Access

    Thermal Performance of Micro Hotplates with Novel Shapes Based on Single-Layer SiO2 Suspended Film

    by Qi Liu, Guifu Ding, Yipin Wang, Jinyuan Yao

    In this paper, two kinds of suspended micro hotplate with novel shapes of multibeam structure and reticular structure are designed. These designs have a reliable mechanical strength, so they can be designed and fabricated on single-layer SiO2 suspended film through a simplified process. Single-layer suspended film helps to reduce power consumption. Based on the new film shapes, different resistance heaters with various widths and thicknesses are designed. Then, the temperature uniformity and power consumption of different micro hotplates are compared to study the effect of these variables and obtain the one with the optimal thermal performance. We report the simulations of temperature uniformity and give the corresponding infrared images in measurement. The experimental temperature differences are larger than those of the simulation. Experimental results show that the lowest power consumption and the minimum temperature difference are 43 mW and 50 °C, respectively, when the highest temperature on the suspended platform (240 × 240 μm2) is 450 °C. Compared to the traditional four-beam micro hotplate, temperature non-uniformity is reduced by about 30–50%.


  • Open Access

    Fabrication of Electromagnetically-Driven Tilted Microcoil on Polyimide Capillary Surface for Potential Single-Fiber Endoscope Scanner Application

    by Zhuoqing Yang, Jianhao Shi, Bin Sun, Jinyuan Yao, Guifu Ding, Renshi Sawada

    The design and fabrication of a Micro-electromechanical Systems (MEMS)-based tilted microcoil on a polyimide capillary are reported in this paper, proposed for an electromagnetically-driven single-fiber endoscope scanner application. The parameters of the tilted microcoil were optimized by simulation. It is proved that the largest driving force could be achieved when the tilt-angle, the pitch and the coil turns of the designed microcoil were 60°, 80 µm and 20, respectively. The modal simulation of the designed fiber scanner was carried out. The prototypes of the tilted microcoils were fabricated on the surface of polyimide capillary with 1 mm-diameter using our developed cylindrical projection lithography system. The dimensions of the two tilted microcoils were as follows: one was tilt-angle 45°, line width 10 ± 0.2 µm, coil pitch 78.5 ± 0.5 µm, and the other was tilt-angle 60°, line width 10 ± 0.2 µm, coil pitch 81.5 ± 0.5 µm. Finally, a direct mask-less electroplating process was employed to fabricate the copper microcoil with 15 µm thickness on the gold (Au) seed-layer, and the corresponding line width was expanded to 40 µm.