Jizhou Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jizhou Hu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Hemi Qu
State Key Laboratory of Precision Measuring Technology & Instruments , Tianjin University , Tianjin 300072 , China
3 shared publications - Wei Pang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China
3 shared publications - Xuexin Duan
State Key Laboratory of Precision Measuring Technology and Instruments, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin 300072, China
3 shared publications - Hao Zhang
State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
2 shared publications - Wenpeng Liu
Harvard Medical School Harvard University Boston MA 02115 USA
2 shared publications
Latest Publications
- Open Access
In-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
A microfluidic film bulk acoustic wave resonator gas sensor (mFBAR) adapted specifically as an in-line detector in gas chromatography was described. This miniaturized vapor sensor was a non-destructive detector with very low dead volume (0.02 μL). It was prepared by enclosing the resonator in a microfluidic channel on a chip with dimensions of only 15 mm × 15 mm × 1 mm. The device with polymer coating showed satisfactory performance in the detection of organophosphorus compound, demonstrating a very low detection limit (a dozen parts per billion) with relatively short response time (about fifteen seconds) toward the simulant of chemical warfare agent, dimethyl methylphosphonate. The in-line detection of the mFBAR sensor with FID was constructed and employed to directly measure the concentration profile on the solid surface by the mFBAR with the controlled concentration profile in the mobile phase at the same time. The difference of peak-maximum position between mobile phase and solid phase could be a convenient indicator to measure mass transfer rate. With the response of the mFBAR and FID obtained in one injection, an injection mass-independent parameter can be calculated and used to identify the analyte of interest.
Open AccessIn-Line Detection with Microfluidic Bulk Acoustic Wave Resonator Gas Sensor for Gas Chromatography
A microfluidic film bulk acoustic wave resonator gas sensor (mFBAR) adapted specifically as an in-line detector in gas chromatography was described. This miniaturized vapor sensor was a non-destructive detector with very low dead volume (0.02 μL). It was prepared by enclosing the resonator in a microfluidic channel on a chip with dimensions of only 15 mm × 15 mm × 1 mm. The device with polymer coating showed satisfactory performance in the detection of organophosphorus compound, demonstrating a very low detection limit (a dozen parts per billion) with relatively short response time (about fifteen seconds) toward the simulant of chemical warfare agent, dimethyl methylphosphonate. The in-line detection of the mFBAR sensor with FID was constructed and employed to directly measure the concentration profile on the solid surface by the mFBAR with the controlled concentration profile in the mobile phase at the same time. The difference of peak-maximum position between mobile phase and solid phase could be a convenient indicator to measure mass transfer rate. With the response of the mFBAR and FID obtained in one injection, an injection mass-independent parameter can be calculated and used to identify the analyte of interest.
- Open Access
- 5 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (6) , 178
Correction: Liu, W. et al. A Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films. Micromachines, 2017, 8, 116
In the published paper [1], there is an error in Figure 3
- 5 June 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (6) , 178
Open AccessCorrection: Liu, W. et al. A Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films. Micromachines, 2017, 8, 116
In the published paper [1], there is an error in Figure 3
- Open Access
- 5 April 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (4) , 116
A Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films
We developed a highly sensitive humidity sensor based on the combination of ultrahigh-frequency film bulk acoustic resonator (FBAR) and nano-assembled polyelectrolyte (PET) thin films. The water molecule absorption efficiency was optimized by forming loosely-packed PET nanostructures. Then, the humidity sensing characteristics were analyzed in terms of sensitivity, linearity, reversibility, stability and detection limit. As a result, PET-coated FBAR exhibits excellent humidity sensitivity of 2202.20 Hz/ppm, which is five orders of magnitude higher than quartz crystal microbalance (QCM). Additionally, temperature dependence was investigated with the result that PET-coated FBAR possessed a higher sensitivity at low temperature. Furthermore, we realized the selective detection of water vapor from volatile organic compounds (VOCs) with respect to the polarity property. Owing to the high sensitivity, miniaturized size and ultrahigh operating frequency, PET-coated FBAR is uniquely favorable as a wireless humidity sensor node to integrate into wireless sensor networks (WSNs).
- 5 April 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (4) , 116
Open AccessA Highly Sensitive Humidity Sensor Based on Ultrahigh-Frequency Microelectromechanical Resonator Coated with Nano-Assembled Polyelectrolyte Thin Films
We developed a highly sensitive humidity sensor based on the combination of ultrahigh-frequency film bulk acoustic resonator (FBAR) and nano-assembled polyelectrolyte (PET) thin films. The water molecule absorption efficiency was optimized by forming loosely-packed PET nanostructures. Then, the humidity sensing characteristics were analyzed in terms of sensitivity, linearity, reversibility, stability and detection limit. As a result, PET-coated FBAR exhibits excellent humidity sensitivity of 2202.20 Hz/ppm, which is five orders of magnitude higher than quartz crystal microbalance (QCM). Additionally, temperature dependence was investigated with the result that PET-coated FBAR possessed a higher sensitivity at low temperature. Furthermore, we realized the selective detection of water vapor from volatile organic compounds (VOCs) with respect to the polarity property. Owing to the high sensitivity, miniaturized size and ultrahigh operating frequency, PET-coated FBAR is uniquely favorable as a wireless humidity sensor node to integrate into wireless sensor networks (WSNs).