XMXiaofeng Meng

Xiaofeng Meng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiaofeng Meng has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method

    by Ningning Lin, Xiaofeng Meng, Jing Nie

    In this paper, the influence of temperature on quartz crystal microbalance (QCM) sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of −3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability.


  • Research on the Dynamic Calibration of Thermocouple and Temperature Excitation Signal Generation Method Based on Shock-Tube Theory

    by Zhaoxin Yang, Xiaofeng Meng

    This paper introduces the equipment for generating an excitation signal during the process of thermocouple dynamic calibration in air medium, with the objective of dealing with the problems existing extensively in the excitation signal of incapable assessment of the rising time and inaccuracy in the traceability for the step amplitude. Based on the shock-tube theory, the step-temperature excitation signal that is suitable for the dynamic calibration of the thermocouple with appreciable rising time, wide-frequency bandwidth, and traceable step amplitude can be generated by means of the improvement in the structure of the traditional shock tube as well as the compensation of the shock-tube parameters. Through on-site assessment experimentation and dynamic modeling of the thermocouple, the time constant of the thermocouple can be obtained and the dynamic response of the thermocouple can be modified and compensated, the calibration result of which shows that the dynamic calibration method of the thermocouple proposed in this paper can be implemented for different ranges of frequencies and different phases of the temperature sensor with high reliability; moreover, the calibration equipment is miniaturized.