Tongdong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tongdong Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chenyu Zhang
College of Power and Energy Engineering, Harbin Engineering University, Harbin 150001, People’s Republic of China
2 shared publications - Jianjun Ding
School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an, Shaanxi 710049, People’s Republic of China
2 shared publications - Liang Yu
Northwestern Polytechnical University
2 shared publications - Libo Zhao
School of Instrument Science and Technology, Xi’an Jiaotong University, Xi’an, China
2 shared publications - Ran Wang
College of Logistics Engineering, Shanghai Maritime University, Shanghai 201306, P. R. China
2 shared publications - Xiaopeng Zhang
Northwest Institute of Nuclear Technology, Xi’an 710024, China
2 shared publications
Latest Publications
- Open Access
- 2 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8850
Uncertainty Quantification for Infrasound Propagation in the Atmospheric Environment
The propagation of infrasound in the atmosphere is influenced by atmospheric environmental parameters, which affect the precise localization of the infrasound source. Therefore, it has become crucial to quantify the influence of atmospheric environmental parameters on infrasound propagation. First, in this paper, the tau-p model is chosen as the physical model of infrasound propagation in a non-uniform moving medium. The atmospheric environmental parameters affecting infrasound propagation are determined. Secondly, the atmospheric environmental parameter distribution data are generated using the Sobol sampling method. Third, the generated atmospheric data are incorporated into the physical model of infrasound propagation to solve the output. Finally, Sobol sensitivity analysis is performed for each parameter, and the atmospheric parameter with the largest Sobol index is identified as the one with the most significant influence on infrasound propagation.
- 2 September 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (17) , 8850
Open AccessUncertainty Quantification for Infrasound Propagation in the Atmospheric Environment
The propagation of infrasound in the atmosphere is influenced by atmospheric environmental parameters, which affect the precise localization of the infrasound source. Therefore, it has become crucial to quantify the influence of atmospheric environmental parameters on infrasound propagation. First, in this paper, the tau-p model is chosen as the physical model of infrasound propagation in a non-uniform moving medium. The atmospheric environmental parameters affecting infrasound propagation are determined. Secondly, the atmospheric environmental parameter distribution data are generated using the Sobol sampling method. Third, the generated atmospheric data are incorporated into the physical model of infrasound propagation to solve the output. Finally, Sobol sensitivity analysis is performed for each parameter, and the atmospheric parameter with the largest Sobol index is identified as the one with the most significant influence on infrasound propagation.
- Open Access
- 2 July 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (13) , 3181
Infrasound Source Localization of Distributed Stations Using Sparse Bayesian Learning and Bayesian Information Fusion
The precise localization of the infrasound source is important for infrasound event monitoring. The localization of infrasound sources is influenced by the atmospheric propagation environment and infrasound measurement equipment in the large-scale global distribution of infrasound arrays. A distributed infrasound source localization method based on sparse Bayesian learning (SBL) and Bayesian information fusion is proposed to reduce the localization error. First, the arrival azimuth of the infrasound source is obtained based on the SBL algorithm. Then, the infrasound source localization result is obtained by the Bayesian information fusion algorithm. The localization error of the infrasound source can be reduced by this infrasound source method, which incorporates the uncertainty of the infrasound propagation environment and infrasound measurement equipment into the infrasound source localization results. The effectiveness of the proposed algorithm was validated using rocket motor explosion data from the Utah Test and Training Range (UTTR). The experimental results show that the arrival azimuth estimation error can be within 2° and the localization distance error is 3.5 km.
- 2 July 2022
- Published by MDPI AG in Remote Sensing
- Vol. 14 (13) , 3181
Open AccessInfrasound Source Localization of Distributed Stations Using Sparse Bayesian Learning and Bayesian Information Fusion
The precise localization of the infrasound source is important for infrasound event monitoring. The localization of infrasound sources is influenced by the atmospheric propagation environment and infrasound measurement equipment in the large-scale global distribution of infrasound arrays. A distributed infrasound source localization method based on sparse Bayesian learning (SBL) and Bayesian information fusion is proposed to reduce the localization error. First, the arrival azimuth of the infrasound source is obtained based on the SBL algorithm. Then, the infrasound source localization result is obtained by the Bayesian information fusion algorithm. The localization error of the infrasound source can be reduced by this infrasound source method, which incorporates the uncertainty of the infrasound propagation environment and infrasound measurement equipment into the infrasound source localization results. The effectiveness of the proposed algorithm was validated using rocket motor explosion data from the Utah Test and Training Range (UTTR). The experimental results show that the arrival azimuth estimation error can be within 2° and the localization distance error is 3.5 km.
- Open Access
A Novel Slope Method for Measurement of Fluid Density with a Micro-cantilever under Flexural and Torsional Vibrations
A novel method, which was called a slope method, has been proposed to measure fluid density by the micro-cantilever sensing chip. The theoretical formulas of the slope method were discussed and established when the micro-cantilever sensing chip was under flexural and torsional vibrations. The slope was calculated based on the fitted curve between the excitation and output voltages of sensing chip under the nonresonant status. This measuring method need not sweep frequency to find the accurate resonant frequency. Therefore, the fluid density was measured easily based on the calculated slope. In addition, the micro-cantilver was drived by double sided excitation and free end excitation to oscillate under flexural and torsional vibrations, respectively. The corresponding experiments were carried out to measure the fluid density by the slope method. The measurement results were also analyzed when the sensing chip was under flexural and torsional nonresonant vibrations separately. The measurement accuracies under these vibrations were all better than 1.5%, and the density measuring sensitivity under torsional nonresonant vibration was about two times higher than that under flexural nonresonant vibration.
Open AccessA Novel Slope Method for Measurement of Fluid Density with a Micro-cantilever under Flexural and Torsional Vibrations
A novel method, which was called a slope method, has been proposed to measure fluid density by the micro-cantilever sensing chip. The theoretical formulas of the slope method were discussed and established when the micro-cantilever sensing chip was under flexural and torsional vibrations. The slope was calculated based on the fitted curve between the excitation and output voltages of sensing chip under the nonresonant status. This measuring method need not sweep frequency to find the accurate resonant frequency. Therefore, the fluid density was measured easily based on the calculated slope. In addition, the micro-cantilver was drived by double sided excitation and free end excitation to oscillate under flexural and torsional vibrations, respectively. The corresponding experiments were carried out to measure the fluid density by the slope method. The measurement results were also analyzed when the sensing chip was under flexural and torsional nonresonant vibrations separately. The measurement accuracies under these vibrations were all better than 1.5%, and the density measuring sensitivity under torsional nonresonant vibration was about two times higher than that under flexural nonresonant vibration.
- Open Access
A MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes
Methods to calculate fluid density and viscosity using a micro-cantilever and based on the resonance principle were put forward. Their measuring mechanisms were analyzed and the theoretical equations to calculate the density and viscosity were deduced. The fluid-solid coupling simulations were completed for the micro-cantilevers with different shapes. The sensing chips with micro-cantilevers were designed based on the simulation results and fabricated using the micro electromechanical systems (MEMS) technology. Finally, the MEMS resonant sensor was packaged with the sensing chip to measure the densities and viscosities of eight different fluids under the flexural and torsional vibrating modes separately. The relative errors of the measured densities from 600 kg/m3 to 900 kg/m3 and viscosities from 200 μPa·s to 1000 μPa·s were calculated and analyzed with different microcantilevers under various vibrating modes. The experimental results showed that the effects of the shape and vibrating mode of micro-cantilever on the measurement accuracies of fluid density and viscosity were analyzed in detail.
Open AccessA MEMS Resonant Sensor to Measure Fluid Density and Viscosity under Flexural and Torsional Vibrating Modes
Methods to calculate fluid density and viscosity using a micro-cantilever and based on the resonance principle were put forward. Their measuring mechanisms were analyzed and the theoretical equations to calculate the density and viscosity were deduced. The fluid-solid coupling simulations were completed for the micro-cantilevers with different shapes. The sensing chips with micro-cantilevers were designed based on the simulation results and fabricated using the micro electromechanical systems (MEMS) technology. Finally, the MEMS resonant sensor was packaged with the sensing chip to measure the densities and viscosities of eight different fluids under the flexural and torsional vibrating modes separately. The relative errors of the measured densities from 600 kg/m3 to 900 kg/m3 and viscosities from 200 μPa·s to 1000 μPa·s were calculated and analyzed with different microcantilevers under various vibrating modes. The experimental results showed that the effects of the shape and vibrating mode of micro-cantilever on the measurement accuracies of fluid density and viscosity were analyzed in detail.