Mohd Fairouz Mohd Yousof
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohd Fairouz Mohd Yousof has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
- Salem Al-Ameri
Institute of High Voltage and High Current, School of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Malaysia
11 shared publications - Norhafiz Azis
Department of Electrical and Electronic Engineering, Universiti Putra Malaysia, Selangor, Malaysia
10 shared publications - Ahmed Abu-Siada
Curtin University, Perth, WA, Australia
9 shared publications - Muhammad Saufi Kamarudin
University Tun Hussein Onn Malaysia
8 shared publications - Rahisham Abdul Rahman
Universiti Tun Hussein Onn Malaysia (UTHM)
8 shared publications - Jasronita Jasni
Univ Putra Malaysia, Fac Engn, Dept Elect & Elect Engn, Serdang 43400, Selangor, Malaysia
6 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by Penteract Technology in Malaysian Journal of Science and Advanced Technology
- p. 20-28
Experimental and Numerical Investigation of Surface Flashover Characteristics in Insulated High Voltage Electrode Systems
This study investigates the effectiveness of insulation materials in enhancing the breakdown voltage performance of high-voltage (HV) electrode systems. Bare electrodes and electrodes coated with Teflon and polyolefin were used to conduct the experimental analysis under controlled conditions (DC). Measurement of the breakdown voltage was done through repeated trials, and statistical analyses, including mean and standard deviation, were carried out to determine the consistency of performance. Furthermore, the distribution of electric fields was modeled through a numerical simulation to describe the breakdown behavior. Results indicate that insulated electrodes significantly improve breakdown voltage compared to bare configurations, with polyolefin demonstrating the highest performance. Despite lower variability demonstrated by Teflon, polyolefin attains a high level of dielectric strength with reasonable variability. AC testing further reveals differences in leakage behavior, indicating the influence of alternating stress on surface conduction. These results confirm that the insulation coating can minimize the concentration of the electric fields, thus increasing the reliability of the system. This work provides a viable and efficient methodology toward enhancing HV electrode workability in industrial process applications like EV contactor testing.
- 20 October 2026
- Published by Penteract Technology in Malaysian Journal of Science and Advanced Technology
- p. 20-28
Open AccessExperimental and Numerical Investigation of Surface Flashover Characteristics in Insulated High Voltage Electrode Systems
This study investigates the effectiveness of insulation materials in enhancing the breakdown voltage performance of high-voltage (HV) electrode systems. Bare electrodes and electrodes coated with Teflon and polyolefin were used to conduct the experimental analysis under controlled conditions (DC). Measurement of the breakdown voltage was done through repeated trials, and statistical analyses, including mean and standard deviation, were carried out to determine the consistency of performance. Furthermore, the distribution of electric fields was modeled through a numerical simulation to describe the breakdown behavior. Results indicate that insulated electrodes significantly improve breakdown voltage compared to bare configurations, with polyolefin demonstrating the highest performance. Despite lower variability demonstrated by Teflon, polyolefin attains a high level of dielectric strength with reasonable variability. AC testing further reveals differences in leakage behavior, indicating the influence of alternating stress on surface conduction. These results confirm that the insulation coating can minimize the concentration of the electric fields, thus increasing the reliability of the system. This work provides a viable and efficient methodology toward enhancing HV electrode workability in industrial process applications like EV contactor testing.
- Open Access
- 12 August 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (8) , e0355934
Grounding systems enhancement using biodegradable waste soil additives: Measurement and analysis
A grounding system is essential for ensuring the safety and reliability of structures, buildings, telecommunication facilities, and transmission line towers by protecting them from short faults or lightning strikes during storms. An efficient grounding system requires low-resistance pathways, which can be achieved by incorporating grounding enhancement materials as additives to the local soil. Grounding enhancement materials generally include conventional chemical agents, natural substances, and modern waste-derived alternatives. This paper proposes the use of new biodegradable waste materials and a metrological framework to improve the effectiveness of grounding systems. In this regard, five grounding system installations were developed and tested using locally available materials in Miri, Sarawak, Malaysia. Investigated materials as high to lower performance are include palm oil decanter cake (DC), wash ash mixed with sea sand (WS, 50:50), coconut shell charcoal (CC), and palm oil mesocarp fibre (POMF). For comparison, the systems were monitored over 6 months from 15 October to 30 April the nest year using the fall-of-potential (FOP) method measurement technique with the 62% rule of single-rod and layered low-resistivity-material (LRM) configurations. This refines a measurement technique that was compared to the performance of the system with native soil (NS). A post-installation proposed for boosting treatment (activated-carbon slurry for CC; decanter-cake slurry for DC) restored resistance improvements over a short observation. The findings contribute to measurement science by finding that validated biodegradable soil-enhancement materials significantly improve grounding resistance over time. Particularly, the CC and DC offer a low-cost, friendly, environmentally responsible option for enhancing grounding system resistance.
- 12 August 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (8) , e0355934
Open AccessGrounding systems enhancement using biodegradable waste soil additives: Measurement and analysis
A grounding system is essential for ensuring the safety and reliability of structures, buildings, telecommunication facilities, and transmission line towers by protecting them from short faults or lightning strikes during storms. An efficient grounding system requires low-resistance pathways, which can be achieved by incorporating grounding enhancement materials as additives to the local soil. Grounding enhancement materials generally include conventional chemical agents, natural substances, and modern waste-derived alternatives. This paper proposes the use of new biodegradable waste materials and a metrological framework to improve the effectiveness of grounding systems. In this regard, five grounding system installations were developed and tested using locally available materials in Miri, Sarawak, Malaysia. Investigated materials as high to lower performance are include palm oil decanter cake (DC), wash ash mixed with sea sand (WS, 50:50), coconut shell charcoal (CC), and palm oil mesocarp fibre (POMF). For comparison, the systems were monitored over 6 months from 15 October to 30 April the nest year using the fall-of-potential (FOP) method measurement technique with the 62% rule of single-rod and layered low-resistivity-material (LRM) configurations. This refines a measurement technique that was compared to the performance of the system with native soil (NS). A post-installation proposed for boosting treatment (activated-carbon slurry for CC; decanter-cake slurry for DC) restored resistance improvements over a short observation. The findings contribute to measurement science by finding that validated biodegradable soil-enhancement materials significantly improve grounding resistance over time. Particularly, the CC and DC offer a low-cost, friendly, environmentally responsible option for enhancing grounding system resistance.
- Open Access
- 7 July 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (7) , e0353356
Insulation failure mapping on power transformer bushing using FRA and electrostatic simulation
The power transformer bushing is a critical insulation component and a frequent contributor to transformer failures. This paper presents combined electrical and Multiphysics approaches for mapping failure mechanisms in Resin-Impregnated Paper (RIP) transformer bushings using frequency response analysis (FRA) and electrostatic analysis. An 11 kV/0.433 kV, 500 kVA power transformer bushing is selected as a case study and modeled using a MATLAB-based equivalent circuit to simulate its FRA characteristics. Variations in bushing circuit capacitance are introduced to represent insulation degradation, surface pollution, and insulator damage, and the corresponding failure modes are mapped through their distinctive FRA signatures. To provide physical insight into these failure mechanisms, a detailed model is developed in COMSOL Multiphysics, where degradation, pollution, and destructive damage are analyzed using electric field and electric potential distributions. The results from the FRA simulation and electrical Multiphysics in this paper provide a framework for understanding the behavior of transformer bushing failures and enable early fault detection. This also improves the transformer bushing maintenance and condition monitoring.
- 7 July 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (7) , e0353356
Open AccessInsulation failure mapping on power transformer bushing using FRA and electrostatic simulation
The power transformer bushing is a critical insulation component and a frequent contributor to transformer failures. This paper presents combined electrical and Multiphysics approaches for mapping failure mechanisms in Resin-Impregnated Paper (RIP) transformer bushings using frequency response analysis (FRA) and electrostatic analysis. An 11 kV/0.433 kV, 500 kVA power transformer bushing is selected as a case study and modeled using a MATLAB-based equivalent circuit to simulate its FRA characteristics. Variations in bushing circuit capacitance are introduced to represent insulation degradation, surface pollution, and insulator damage, and the corresponding failure modes are mapped through their distinctive FRA signatures. To provide physical insight into these failure mechanisms, a detailed model is developed in COMSOL Multiphysics, where degradation, pollution, and destructive damage are analyzed using electric field and electric potential distributions. The results from the FRA simulation and electrical Multiphysics in this paper provide a framework for understanding the behavior of transformer bushing failures and enable early fault detection. This also improves the transformer bushing maintenance and condition monitoring.
- Open Access
- 18 February 2026
- Published by Elsevier in SSRN Electronic Journal
Metrological Approach to Enhance Grounding Systems using Biodegradable Waste Soil Additives: Measurement Techniques and Theoretical Analysis
A grounding system is essential for ensuring the safety and reliability of structures, buildings, telecommunication facilities, and transmission line towers by protecting them from short faults or lightning strikes during storms. An efficient grounding system requires low-resistance pathways, which can be achieved by incorporating grounding enhancement materials as additives to the local soil. Grounding enhancement materials generally include conventional chemical agents, natural substances, and modern waste-derived alternatives. This paper proposes the use of new biodegradable waste materials and a metrological framework to improve the effectiveness of grounding systems. In this regard, five grounding system installations were developed and tested using locally available materials in Miri, Sarawak, Malaysia. Investigated materials include coconut shell charcoal (CC), palm oil decanter cake (DC), wash ash mixed with sea sand (WS, 50:50), and palm oil mesocarp fibre (POMF). For comparison, the systems were monitored over 166 days using the fall-of-potential (FOP) method measurement technique with the 62% rule of single-rod and layered low-resistivity-material (LRM) configurations. This refines a measurement technique that was compared to the performance of the system with native soil (NS). A post-installation proposed for boosting treatment (activated-carbon slurry for CC; decanter-cake slurry for DC) restored resistance improvements over a short observation. The findings contribute to measurement science by finding a validated biodegradable soil-enhancement materials significantly improve grounding resistance over time. Particularly, the CC and DC offer a low-cost, friendly, environmentally responsible option for enhancing grounding system resistance.
- 18 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMetrological Approach to Enhance Grounding Systems using Biodegradable Waste Soil Additives: Measurement Techniques and Theoretical Analysis
A grounding system is essential for ensuring the safety and reliability of structures, buildings, telecommunication facilities, and transmission line towers by protecting them from short faults or lightning strikes during storms. An efficient grounding system requires low-resistance pathways, which can be achieved by incorporating grounding enhancement materials as additives to the local soil. Grounding enhancement materials generally include conventional chemical agents, natural substances, and modern waste-derived alternatives. This paper proposes the use of new biodegradable waste materials and a metrological framework to improve the effectiveness of grounding systems. In this regard, five grounding system installations were developed and tested using locally available materials in Miri, Sarawak, Malaysia. Investigated materials include coconut shell charcoal (CC), palm oil decanter cake (DC), wash ash mixed with sea sand (WS, 50:50), and palm oil mesocarp fibre (POMF). For comparison, the systems were monitored over 166 days using the fall-of-potential (FOP) method measurement technique with the 62% rule of single-rod and layered low-resistivity-material (LRM) configurations. This refines a measurement technique that was compared to the performance of the system with native soil (NS). A post-installation proposed for boosting treatment (activated-carbon slurry for CC; decanter-cake slurry for DC) restored resistance improvements over a short observation. The findings contribute to measurement science by finding a validated biodegradable soil-enhancement materials significantly improve grounding resistance over time. Particularly, the CC and DC offer a low-cost, friendly, environmentally responsible option for enhancing grounding system resistance.
- Open Access
- 9 January 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 255
A novel analytical methodology for estimating high-frequency lumped model inductances and series capacitance of transformer winding: an indirect measurement procedure
- 9 January 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 255
Open AccessA novel analytical methodology for estimating high-frequency lumped model inductances and series capacitance of transformer winding: an indirect measurement procedure
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 20 (1)
An Indirect Measurement Approach of a Uniform Transformer Winding Inductances Using Frequency Response Analysis Data: An Analytical Approach
This article proposes an innovative analytical method that estimates winding inductances directly from measurable frequency response analysis (FRA) data. The method constructs a polynomial function based on the inverse‐square sum of short‐circuit natural frequencies and equivalent inductance, incorporating a coupling factor that captures the extent of mutual interaction between discs. Unlike earlier numerical and optimisation‐based methods that typically involve a large number of inductance parameters, the proposed approach yields a physically meaningful real positive solution for the coupling factor. The approach offers a practical analytical solution for indirectly measuring the self‐ and mutual inductances of uniform windings, involving the measurement of relevant winding parameters—such as equivalent inductance, short‐circuit natural frequencies and series and shunt capacitances—using frequency response impedance data. The method then estimates self‐ and mutual inductances for uniform windings by solving a generalised polynomial developed for an N ‐section model, enabling the derivation of all windings' inductances. Experimental validation on isolated transformer windings demonstrated strong agreement between measured and estimated FRA curves, with root mean square error (RMSE) values below . These results confirm that the method offers a practical, traceable and accurate measurement‐based solution for inductance estimation, with potential applications in transformer condition assessment and fault diagnosis.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 20 (1)
Open AccessAn Indirect Measurement Approach of a Uniform Transformer Winding Inductances Using Frequency Response Analysis Data: An Analytical Approach
This article proposes an innovative analytical method that estimates winding inductances directly from measurable frequency response analysis (FRA) data. The method constructs a polynomial function based on the inverse‐square sum of short‐circuit natural frequencies and equivalent inductance, incorporating a coupling factor that captures the extent of mutual interaction between discs. Unlike earlier numerical and optimisation‐based methods that typically involve a large number of inductance parameters, the proposed approach yields a physically meaningful real positive solution for the coupling factor. The approach offers a practical analytical solution for indirectly measuring the self‐ and mutual inductances of uniform windings, involving the measurement of relevant winding parameters—such as equivalent inductance, short‐circuit natural frequencies and series and shunt capacitances—using frequency response impedance data. The method then estimates self‐ and mutual inductances for uniform windings by solving a generalised polynomial developed for an N ‐section model, enabling the derivation of all windings' inductances. Experimental validation on isolated transformer windings demonstrated strong agreement between measured and estimated FRA curves, with root mean square error (RMSE) values below . These results confirm that the method offers a practical, traceable and accurate measurement‐based solution for inductance estimation, with potential applications in transformer condition assessment and fault diagnosis.
- 17 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
Effect of dibenzyl disulphide on partial discharge characteristics in mineral oil–impregnated cellulose pressboard
- 17 September 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 251
Effect of dibenzyl disulphide on partial discharge characteristics in mineral oil–impregnated cellulose pressboard
- Open Access
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (2) , 1289-1296
Broken rotor bar detection of three phase induction motor using frequency response analysis
Three phase induction motors (TPIMs) are broadly utilized for various applications in the industry, but they are prone to different faults that can affect their performance and reliability. One common fault is a broken rotor bar, which leads to vibration, noise, and reduced efficiency. Therefore, detecting and identifying this fault early is important to avoid further damage and reduce maintenance costs. This paper proposes a novel method using frequency response analysis (FRA) to diagnose broken rotor bars in a TPIM. The response of normal motor is measured to obtain the baseline. Subsequently, the rotor was inflected with physical damage to represent a broken rotor bar. By comparing normal and faulty rotors, the measurement shows that frequency response analysis is sensitive toward various fault severity based on the number of broken rotor bars.
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (2) , 1289-1296
Open AccessBroken rotor bar detection of three phase induction motor using frequency response analysis
Three phase induction motors (TPIMs) are broadly utilized for various applications in the industry, but they are prone to different faults that can affect their performance and reliability. One common fault is a broken rotor bar, which leads to vibration, noise, and reduced efficiency. Therefore, detecting and identifying this fault early is important to avoid further damage and reduce maintenance costs. This paper proposes a novel method using frequency response analysis (FRA) to diagnose broken rotor bars in a TPIM. The response of normal motor is measured to obtain the baseline. Subsequently, the rotor was inflected with physical damage to represent a broken rotor bar. By comparing normal and faulty rotors, the measurement shows that frequency response analysis is sensitive toward various fault severity based on the number of broken rotor bars.
- Open Access
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (1) , 76-88
Transmission line sag and magnetic field analysis with sag parabolic equations and Biot-Savart law
This study presents a novel approach to enhance the precision of calculating sag and magnetic fields beneath overhead transmission lines. The Biot-Savart law is integrated with parabolic equations to assign multiple magnetic field sources to each conductor, resulting in improved prediction accuracy. Addressing oversimplifications in traditional models improves the analysis of transmission lines in real-world scenarios. An analysis was performed using MATLAB and Simulink to validate the effectiveness and broad applicability of different configurations. The results demonstrated a significant improvement in precision compared to traditional methods, indicating that this approach has the potential to establish new benchmarks in the field. This methodology makes significant contributions to electromagnetic studies, offering engineers a reliable tool for designing transmission systems that are both safer and more efficient. This advancement in electrical engineering greatly improves transmission network performance by enhancing sag and magnetic field prediction accuracy. This aids in better maintenance planning and reduces outage risks, resulting in more efficient operations and improved overall performance.
- 1 February 2025
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 15 (1) , 76-88
Open AccessTransmission line sag and magnetic field analysis with sag parabolic equations and Biot-Savart law
This study presents a novel approach to enhance the precision of calculating sag and magnetic fields beneath overhead transmission lines. The Biot-Savart law is integrated with parabolic equations to assign multiple magnetic field sources to each conductor, resulting in improved prediction accuracy. Addressing oversimplifications in traditional models improves the analysis of transmission lines in real-world scenarios. An analysis was performed using MATLAB and Simulink to validate the effectiveness and broad applicability of different configurations. The results demonstrated a significant improvement in precision compared to traditional methods, indicating that this approach has the potential to establish new benchmarks in the field. This methodology makes significant contributions to electromagnetic studies, offering engineers a reliable tool for designing transmission systems that are both safer and more efficient. This advancement in electrical engineering greatly improves transmission network performance by enhancing sag and magnetic field prediction accuracy. This aids in better maintenance planning and reduces outage risks, resulting in more efficient operations and improved overall performance.
- Open Access
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 36 (1) , 53-63
Improving magnetic fields in overhead transmission lines using the insulated cross-arm method
This research study evaluates the effectiveness of the insulated cross-arm (ICA) method in reducing magnetic field (MF) levels in transmission lines. Using Ansys Maxwell finite element method (FEM) software, the study models and analyses the MF distribution in 132 kV and 275 kV overhead transmission lines (OTLs) in Malaysia. The findings reveal that implementing the ICA method can substantially reduce MF levels, improving MF performance by 36% (at 132 kV) and 48% (at 275 kV). These findings have important implications for mitigating potential health risks associated with high MF exposure near transmission lines. Furthermore, the study highlights the potential for future enhancements in ampacity and emphasizes the importance of promoting a health-conscious environment. Field studies, assessments, and investigations into economic feasibility and practical implementation are recommended for further validation and application of the ICA method. Overall, this research study contributes to the knowledge and understanding of reducing MF exposure and improving the efficiency of power transmission systems.
- 1 October 2024
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 36 (1) , 53-63
Open AccessImproving magnetic fields in overhead transmission lines using the insulated cross-arm method
This research study evaluates the effectiveness of the insulated cross-arm (ICA) method in reducing magnetic field (MF) levels in transmission lines. Using Ansys Maxwell finite element method (FEM) software, the study models and analyses the MF distribution in 132 kV and 275 kV overhead transmission lines (OTLs) in Malaysia. The findings reveal that implementing the ICA method can substantially reduce MF levels, improving MF performance by 36% (at 132 kV) and 48% (at 275 kV). These findings have important implications for mitigating potential health risks associated with high MF exposure near transmission lines. Furthermore, the study highlights the potential for future enhancements in ampacity and emphasizes the importance of promoting a health-conscious environment. Field studies, assessments, and investigations into economic feasibility and practical implementation are recommended for further validation and application of the ICA method. Overall, this research study contributes to the knowledge and understanding of reducing MF exposure and improving the efficiency of power transmission systems.