Improving magnetic fields in overhead transmission lines using the insulated cross-arm method
Authors:
- Matiullah AhsanMAMatiullah Ahsan
- Nor Ramdon BaharomNBNor Ramdon Baharom
- Zainab ZainalZZZainab Zainal
- Norain SahariNSNorain Sahari
- Faridah HanimFHFaridah Hanim
- Saufi KamarudinSKSaufi Kamarudin
- Rashisham Abd RahmanRashisham Abd Rahman
- Mohd Fairouz Mohd YousofMYMohd Fairouz Mohd Yousof
- Nor Akmal JamailNJNor Akmal Jamail
- Nordiana Azlin OthmanNONordiana Azlin Othman
Open Access
- 1 October 2024
- journal article
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 36 (1) , 53-63
Abstract
This research study evaluates the effectiveness of the insulated cross-arm (ICA) method in reducing magnetic field (MF) levels in transmission lines. Using Ansys Maxwell finite element method (FEM) software, the study models and analyses the MF distribution in 132 kV and 275 kV overhead transmission lines (OTLs) in Malaysia. The findings reveal that implementing the ICA method can substantially reduce MF levels, improving MF performance by 36% (at 132 kV) and 48% (at 275 kV). These findings have important implications for mitigating potential health risks associated with high MF exposure near transmission lines. Furthermore, the study highlights the potential for future enhancements in ampacity and emphasizes the importance of promoting a health-conscious environment. Field studies, assessments, and investigations into economic feasibility and practical implementation are recommended for further validation and application of the ICA method. Overall, this research study contributes to the knowledge and understanding of reducing MF exposure and improving the efficiency of power transmission systems.Keywords
This publication has 20 references indexed in Scilit:
- IEEE Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power Lines2020
- Comparative Analysis of Photovoltaic Faults and Performance Evaluation of its Detection TechniquesIEEE Access, 2020
- SOC prediction of Lithium-Ion Battery using Extended Kalman Filter2018
- Innovative insulated cross-arm: Requirements, testing and construction2017
- Modeling and control of extended multiterminal high voltage direct current systems with three-wire bipole structureInternational Transactions on Electrical Energy Systems, 2014
- A coastal trial facility for high voltage composite cross-arms2012
- GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 Hz TO 100 kHz)Health Physics, 2010
- Power transfer capacity improvements of existing overhead line systems2010
- Extremely low frequency electromagnetic field (ELF EMF) survey of residential areas around transmission lines2007
- A pooled analysis of magnetic fields and childhood leukaemiaBritish Journal of Cancer, 2000