Liang Xu
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Liang Xu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Zhaopeng Dong
College of Engineering Science and Technology, Shanghai Ocean University, Shanghai 201306, China
3 shared publications - Lin Ye
Department of Instrument Science and Engineering, Shanghai Jiaotong University, Shanghai 200240, China
1 shared publication - Ming Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication - Shiyang Li
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication - Tianyue Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication - Tianyue Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication
Latest Publications
- Open Access
- 28 November 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (12) , 1438
RETRACTED: Dong et al. Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers. Micromachines 2022, 13, 1638
The journal retracts the article titled “Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers”
- 28 November 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (12) , 1438
Open AccessRETRACTED: Dong et al. Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers. Micromachines 2022, 13, 1638
The journal retracts the article titled “Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers”
- Open Access
- 16 August 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1610
Performance Analysis and Experimental Research of a Dual-Vibrator Traveling Wave Ultrasonic Motor
In order to facilitate the widespread application of ultrasonic motors, it is essential to conduct a quantitative study aimed at enhancing their performance. The present paper provides a comprehensive theoretical analysis of an ultrasonic motor equipped with dual vibrators, enabling operation in both the single-driven and dual-driven modes, thereby enhancing versatility in terms of performance adjustment. This study provides a detailed examination of the motor’s unique performance characteristics and its varying output responses to different driving signals. Experimental investigations are conducted in both the single-driven and dual-driven modes to validate theoretical predictions. The results demonstrate that the motor exhibits a maximum speed, torque, and power that are 1.59, 1.28, and 1.62 times higher than those of the single-driven stator, respectively. A conclusion can be drawn that the motor will attain the desired performance when operated in the appropriate driven mode.
- 16 August 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (8) , 1610
Open AccessPerformance Analysis and Experimental Research of a Dual-Vibrator Traveling Wave Ultrasonic Motor
In order to facilitate the widespread application of ultrasonic motors, it is essential to conduct a quantitative study aimed at enhancing their performance. The present paper provides a comprehensive theoretical analysis of an ultrasonic motor equipped with dual vibrators, enabling operation in both the single-driven and dual-driven modes, thereby enhancing versatility in terms of performance adjustment. This study provides a detailed examination of the motor’s unique performance characteristics and its varying output responses to different driving signals. Experimental investigations are conducted in both the single-driven and dual-driven modes to validate theoretical predictions. The results demonstrate that the motor exhibits a maximum speed, torque, and power that are 1.59, 1.28, and 1.62 times higher than those of the single-driven stator, respectively. A conclusion can be drawn that the motor will attain the desired performance when operated in the appropriate driven mode.
- Open Access
- 29 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1638
RETRACTED: Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers
To improve suitability in applications with high dynamic performance requirements, the transient response characteristics of high-power piezoelectric transducers should be studied quantitatively. This paper proposes the vector reduction method to solve the complex transient equations and obtains a transient matching scheme clarifying the mechanism of electrical matching resistance on electromechanical damping. A matching scheme with a combination of full-bridge inverter, transformer and series LC circuit is designed and validated, which can provide suitable electrical damping without causing energy losses. Consequently, the experiment verifies the transient properties of the proposed scheme. For a typical piezoelectric cutting transducer with 100.8 ms response time, our scheme is verified to have high dynamic performance within frequency response time of 5.5 ms and vibration response time of 15.0 ms.
- 29 September 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1638
Open AccessRETRACTED: Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers
To improve suitability in applications with high dynamic performance requirements, the transient response characteristics of high-power piezoelectric transducers should be studied quantitatively. This paper proposes the vector reduction method to solve the complex transient equations and obtains a transient matching scheme clarifying the mechanism of electrical matching resistance on electromechanical damping. A matching scheme with a combination of full-bridge inverter, transformer and series LC circuit is designed and validated, which can provide suitable electrical damping without causing energy losses. Consequently, the experiment verifies the transient properties of the proposed scheme. For a typical piezoelectric cutting transducer with 100.8 ms response time, our scheme is verified to have high dynamic performance within frequency response time of 5.5 ms and vibration response time of 15.0 ms.
- Open Access
Nonlinearity Analysis and Parameters Optimization for an Inductive Angle Sensor
Using the finite element method (FEM) and particle swarm optimization (PSO), a nonlinearity analysis based on parameter optimization is proposed to design an inductive angle sensor. Due to the structure complexity of the sensor, understanding the influences of structure parameters on the nonlinearity errors is a critical step in designing an effective sensor. Key parameters are selected for the design based on the parameters’ effects on the nonlinearity errors. The finite element method and particle swarm optimization are combined for the sensor design to get the minimal nonlinearity error. In the simulation, the nonlinearity error of the optimized sensor is 0.053% in the angle range from −60° to 60°. A prototype sensor is manufactured and measured experimentally, and the experimental nonlinearity error is 0.081% in the angle range from −60° to 60°.
Open AccessNonlinearity Analysis and Parameters Optimization for an Inductive Angle Sensor
Using the finite element method (FEM) and particle swarm optimization (PSO), a nonlinearity analysis based on parameter optimization is proposed to design an inductive angle sensor. Due to the structure complexity of the sensor, understanding the influences of structure parameters on the nonlinearity errors is a critical step in designing an effective sensor. Key parameters are selected for the design based on the parameters’ effects on the nonlinearity errors. The finite element method and particle swarm optimization are combined for the sensor design to get the minimal nonlinearity error. In the simulation, the nonlinearity error of the optimized sensor is 0.053% in the angle range from −60° to 60°. A prototype sensor is manufactured and measured experimentally, and the experimental nonlinearity error is 0.081% in the angle range from −60° to 60°.