Zhongke Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhongke Wang has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Yee Cheong Lam
SIMTech-NTU Joint Laboratory (Precision Machining), Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
3 shared publications - Celescia Siew Mun Lye
SIMTech-NTU Joint Laboratory (Precision Machining), Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
2 shared publications H. Y. Zheng
Singapore Institute of Manufacturing Technology (SIMTech) , 71 Nanyang Drive, Singapore 638075, Singapore
2 shared publicationsH.Y. Zheng
Singapore Institute of Manufacturing Technology, Singapore, Singapore
2 shared publicationsS.M. Yuan
Beihang University, Beijing, P.R. China
2 shared publications- Yingchun Guan
School of Mechanical Engineering and Automation, Beihang University 1 , Beijing 100191
2 shared publications
Latest Publications
- Open Access
- 31 December 2022
- Published by MDPI AG in Micromachines
- Vol. 14 (1) , 119
Interaction Energy Dependency on Pulse Width in ns NIR Laser Scanning of Silicon
Laser ablation of semiconductor silicon has been extensively studied in the past few decades. In the ultrashort pulse domain, whether in the fs scale or ps scale, the pulse energy fluence threshold in the ablation of silicon is strongly dependent on the pulse width. However, in the ns pulse scale, the energy fluence threshold dependence on the pulse width is not well understood. This study elucidates the interaction energy dependency on pulse width in ns NIR laser ablation of silicon. The level of ablation or melting was determined by the pulse energy deposition rate, which was proportional to laser peak power. Shorter pulse widths with high peak power were likely to induce surface ablation, while longer pulse widths were likely to induce surface melting. The ablation threshold increased from 5.63 to 24.84 J/cm2 as the pulse width increased from 26 to 500 ns. The melting threshold increased from 3.33 to 5.76 J/cm2 as the pulse width increased from 26 to 200 ns, and then remained constant until 500 ns, the longest width investigated. Distinct from a shorter pulse width, a longer pulse width did not require a higher power level for inducing surface melting, as surface melting can be induced at a lower power with the longer heating time of a longer pulse width. The line width from surface melting was less than the focused spot size; the line appeared either as a continuous line at slow scanning speed or as isolated dots at high scanning speed. In contrast, the line width from ablation significantly exceeded the focused spot size.
- 31 December 2022
- Published by MDPI AG in Micromachines
- Vol. 14 (1) , 119
Open AccessInteraction Energy Dependency on Pulse Width in ns NIR Laser Scanning of Silicon
Laser ablation of semiconductor silicon has been extensively studied in the past few decades. In the ultrashort pulse domain, whether in the fs scale or ps scale, the pulse energy fluence threshold in the ablation of silicon is strongly dependent on the pulse width. However, in the ns pulse scale, the energy fluence threshold dependence on the pulse width is not well understood. This study elucidates the interaction energy dependency on pulse width in ns NIR laser ablation of silicon. The level of ablation or melting was determined by the pulse energy deposition rate, which was proportional to laser peak power. Shorter pulse widths with high peak power were likely to induce surface ablation, while longer pulse widths were likely to induce surface melting. The ablation threshold increased from 5.63 to 24.84 J/cm2 as the pulse width increased from 26 to 500 ns. The melting threshold increased from 3.33 to 5.76 J/cm2 as the pulse width increased from 26 to 200 ns, and then remained constant until 500 ns, the longest width investigated. Distinct from a shorter pulse width, a longer pulse width did not require a higher power level for inducing surface melting, as surface melting can be induced at a lower power with the longer heating time of a longer pulse width. The line width from surface melting was less than the focused spot size; the line appeared either as a continuous line at slow scanning speed or as isolated dots at high scanning speed. In contrast, the line width from ablation significantly exceeded the focused spot size.
- Open Access
- 24 March 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (4) , 506
Multi-Foci Laser Separation of Sapphire Wafers with Partial Thickness Scanning
With multi-foci laser cutting technology for sapphire wafer separation, the entire cross-section is generally scanned with single or multiple passes. This investigation proposes a new separation technique through partial thickness scanning. The energy effectivity and efficiency of the picosecond laser were enhanced through a two-zone partial thickness scanning by exploiting the internal reflection at the rough exit surface. Each zone spanned only one-third thickness of the cross-section, and only two out of three zones were scanned consecutively. A laser beam of 0.57 W and 50 kHz pulse repetition rate was split into 9 foci, each with a 2.20 μm calculated focused spot diameter. By only scanning the top two-thirds sample thickness, first its middle section then upper section, a cleavable sample could result. This was achieved with the lowest energy deposition at the fastest scanning speed of 10 mm/s investigated. Although with partial thickness scanning only, counter intuitively, the cleaved sample had a previously unattained uniform roughened sidewall profile over the entire thickness. This is a desirable outcome in LED manufacturing. As such, this proposed scheme could attain a cleavable sample with the desired uniformly roughened sidewall profile with less energy usage and faster scanning speed.
- 24 March 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (4) , 506
Open AccessMulti-Foci Laser Separation of Sapphire Wafers with Partial Thickness Scanning
With multi-foci laser cutting technology for sapphire wafer separation, the entire cross-section is generally scanned with single or multiple passes. This investigation proposes a new separation technique through partial thickness scanning. The energy effectivity and efficiency of the picosecond laser were enhanced through a two-zone partial thickness scanning by exploiting the internal reflection at the rough exit surface. Each zone spanned only one-third thickness of the cross-section, and only two out of three zones were scanned consecutively. A laser beam of 0.57 W and 50 kHz pulse repetition rate was split into 9 foci, each with a 2.20 μm calculated focused spot diameter. By only scanning the top two-thirds sample thickness, first its middle section then upper section, a cleavable sample could result. This was achieved with the lowest energy deposition at the fastest scanning speed of 10 mm/s investigated. Although with partial thickness scanning only, counter intuitively, the cleaved sample had a previously unattained uniform roughened sidewall profile over the entire thickness. This is a desirable outcome in LED manufacturing. As such, this proposed scheme could attain a cleavable sample with the desired uniformly roughened sidewall profile with less energy usage and faster scanning speed.
- Open Access
- 28 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1328
Multi-Foci Division of Nonlinear Energy Absorption on Ultrashort Pulse Laser Singulation of Sapphire Wafers
The multi-foci division of through thickness nonlinear pulse energy absorption on ultrashort pulse laser singulation of single side polished sapphire wafers has been investigated. Firstly, it disclosed the enhancement of energy absorption by the total internal reflection of the laser beam exiting from an unpolished rough surface. Secondly, by optimizing energy distribution between foci and their proximity, favorable multi-foci energy absorption was induced. Lastly, for effective nonlinear energy absorption for wafer separation, it highlighted the importance of high laser pulse energy fluence at low pulse repetition rates with optimized energy distribution, and the inadequacy of increasing energy deposition through reducing scanning speed alone. This study concluded that for effective wafer separation, despite the lower pulse energy per focus, energy should be divided over more foci with closer spatial proximity. Once the power density per pulse per focus reached a threshold in the order of 1012 W/cm2, with approximately 15 m between two adjacent foci, wafer could be separated with foci evenly distributed over the entire wafer thickness. When the foci spacing reduced to 5 m, wafer separation could be achieved with pulse energy concentrated only at foci distributed over only the upper or middle one-third wafer thickness.- 28 October 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1328
Open AccessMulti-Foci Division of Nonlinear Energy Absorption on Ultrashort Pulse Laser Singulation of Sapphire Wafers
The multi-foci division of through thickness nonlinear pulse energy absorption on ultrashort pulse laser singulation of single side polished sapphire wafers has been investigated. Firstly, it disclosed the enhancement of energy absorption by the total internal reflection of the laser beam exiting from an unpolished rough surface. Secondly, by optimizing energy distribution between foci and their proximity, favorable multi-foci energy absorption was induced. Lastly, for effective nonlinear energy absorption for wafer separation, it highlighted the importance of high laser pulse energy fluence at low pulse repetition rates with optimized energy distribution, and the inadequacy of increasing energy deposition through reducing scanning speed alone. This study concluded that for effective wafer separation, despite the lower pulse energy per focus, energy should be divided over more foci with closer spatial proximity. Once the power density per pulse per focus reached a threshold in the order of 1012 W/cm2, with approximately 15 m between two adjacent foci, wafer could be separated with foci evenly distributed over the entire wafer thickness. When the foci spacing reduced to 5 m, wafer separation could be achieved with pulse energy concentrated only at foci distributed over only the upper or middle one-third wafer thickness. - Open Access
- 24 February 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (3) , 227
Electrical Resistance Reduction Induced with CO2 Laser Single Line Scan of Polyimide
We conducted a laser parameter study on CO2 laser induced electrical conductivity on a polyimide film. The induced electrical conductivity was found to occur dominantly at the center of the scanning line instead of uniformly across the whole line width. MicroRaman examination revealed that the conductivity was mainly a result of the multi-layers (4–5) of graphene structure induced at the laser irradiation line center. The graphene morphology at the line center appeared as thin wall porous structures together with nano level fiber structures. With sufficient energy dose per unit length and laser power, this surface modification for electrical conductivity was independent of laser pulse frequency but was instead determined by the average laser power. High electrical conductivity could be achieved by a single scan of laser beam at a sufficiently high-power level. To achieve high conductivity, it was not efficient nor effective to utilize a laser at low power but compensating it with a slower scanning speed or having multiple scans. The electrical resistance over a 10 mm scanned length decreased significantly from a few hundred Ohms to 30 Ohms when energy dose per unit length increased from 0.16 J/mm to 1.0 J/mm, i.e., the laser power increased from 5.0 W to 24 W with corresponding power density of 3.44 × 10 W/cm2 to 16.54 W/cm2 respectively at a speed of 12.5 mm/s for a single pass scan. In contrast, power below 5 W at speeds exceeding 22.5 mm/s resulted in a non-conductive open loop.
- 24 February 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (3) , 227
Open AccessElectrical Resistance Reduction Induced with CO2 Laser Single Line Scan of Polyimide
We conducted a laser parameter study on CO2 laser induced electrical conductivity on a polyimide film. The induced electrical conductivity was found to occur dominantly at the center of the scanning line instead of uniformly across the whole line width. MicroRaman examination revealed that the conductivity was mainly a result of the multi-layers (4–5) of graphene structure induced at the laser irradiation line center. The graphene morphology at the line center appeared as thin wall porous structures together with nano level fiber structures. With sufficient energy dose per unit length and laser power, this surface modification for electrical conductivity was independent of laser pulse frequency but was instead determined by the average laser power. High electrical conductivity could be achieved by a single scan of laser beam at a sufficiently high-power level. To achieve high conductivity, it was not efficient nor effective to utilize a laser at low power but compensating it with a slower scanning speed or having multiple scans. The electrical resistance over a 10 mm scanned length decreased significantly from a few hundred Ohms to 30 Ohms when energy dose per unit length increased from 0.16 J/mm to 1.0 J/mm, i.e., the laser power increased from 5.0 W to 24 W with corresponding power density of 3.44 × 10 W/cm2 to 16.54 W/cm2 respectively at a speed of 12.5 mm/s for a single pass scan. In contrast, power below 5 W at speeds exceeding 22.5 mm/s resulted in a non-conductive open loop.
- 15 June 2020
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 32 (3) , 032009
Investigation on fiber laser irradiation of transparent polycarbonate
The study aims to understand the carbonization mechanism when an ns NIR transparent fiber laser beam irradiation of polycarbonate (PC) instead of irradiation using a UV laser beam or ultrashort pulsed laser beam. It reveals that PC can be decomposed with an ns transparent 1064 nm laser beam. The laser fluence threshold under which to cause ablation in PC was not a constant value. The threshold decreased as the scanning pulse number increased. The threshold fluence was above 2.9 J/cm2 at irradiation with 10 pulses. The threshold fluence was above 11.6 mJ/cm2 at irradiation with 2 pulses. The optical transmittance of PC was decreased under laser irradiation. The optical transmittance was reduced by 50% and 90% at laser fluence of 2.9 J/cm2 and 11.6 J/cm2, respectively, at irradiation with 15 pulses. In addition, x-ray photoelectron spectroscopy measurements show that the C/O ratio was reduced 20.8% and 33.2%, respectively. The water contact angle was reduced due to the carbon loss at the PC surface. Inside marking of PC produced a darker contrast than surface marking due to that the carbon was lost at the surface, in contrary, carbonate concentration remained when marking inside the bulk of PC.
- 15 June 2020
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 32 (3) , 032009
Investigation on fiber laser irradiation of transparent polycarbonate
The study aims to understand the carbonization mechanism when an ns NIR transparent fiber laser beam irradiation of polycarbonate (PC) instead of irradiation using a UV laser beam or ultrashort pulsed laser beam. It reveals that PC can be decomposed with an ns transparent 1064 nm laser beam. The laser fluence threshold under which to cause ablation in PC was not a constant value. The threshold decreased as the scanning pulse number increased. The threshold fluence was above 2.9 J/cm2 at irradiation with 10 pulses. The threshold fluence was above 11.6 mJ/cm2 at irradiation with 2 pulses. The optical transmittance of PC was decreased under laser irradiation. The optical transmittance was reduced by 50% and 90% at laser fluence of 2.9 J/cm2 and 11.6 J/cm2, respectively, at irradiation with 15 pulses. In addition, x-ray photoelectron spectroscopy measurements show that the C/O ratio was reduced 20.8% and 33.2%, respectively. The water contact angle was reduced due to the carbon loss at the PC surface. Inside marking of PC produced a darker contrast than surface marking due to that the carbon was lost at the surface, in contrary, carbonate concentration remained when marking inside the bulk of PC.
- 1 June 2019
- Published by ASME International in Journal of Micro and Nano-Manufacturing
- Vol. 7 (2)
Laser Surface Modification of Rare Earth Containing Magnesium Alloy Through Simulated Body Fluid and Its Impact on Cell Viability
Magnesium alloys have a good potential as structural biomaterials for temporary implant applications because of their self-degradation properties and biocompatibility. The surface condition is important for such applications, and lasers are often used to modify the surface characteristics of such components. In this context, the media through which the laser beam passes before reaching the surface to be irradiated is also of interest. In particular, laser irradiation in liquids affects the thermal energy delivery to the surface of the material, which in turns influences the formation of surface structures. In this work, rare earth containing WE54 Mg alloy has been irradiated under air and through a simulated body fluid (SBF) layer using a 500 watt pulsed Nd: YAG laser. As compared to direct laser surface treatment through air, laser irradiation through SBF generates new surface structures and deposition of ions issued from the SBF solution. Scanning electron microscope combined with energy dispersive spectroscopy (EDS) was used for the examination of surface structures formation and determination of elemental composition. Mesenchymal stem cells (MSC) culture was performed on laser modified WE54 alloy surface, and the MSC cytocompatibility on SBF-treated substrates was evaluated by the PrestoBlue™ assay test method. Cell reproducibility was observed on the SBF laser-treated surface which indicated that cell viability was improved by the surface treatment. The deposition of calcium and phosphorus ions on the WE54 surface was beneficial for cell viability. These results motivate the potential use of SBF-based films for biomedical purposes.
- 1 June 2019
- Published by ASME International in Journal of Micro and Nano-Manufacturing
- Vol. 7 (2)
Laser Surface Modification of Rare Earth Containing Magnesium Alloy Through Simulated Body Fluid and Its Impact on Cell Viability
Magnesium alloys have a good potential as structural biomaterials for temporary implant applications because of their self-degradation properties and biocompatibility. The surface condition is important for such applications, and lasers are often used to modify the surface characteristics of such components. In this context, the media through which the laser beam passes before reaching the surface to be irradiated is also of interest. In particular, laser irradiation in liquids affects the thermal energy delivery to the surface of the material, which in turns influences the formation of surface structures. In this work, rare earth containing WE54 Mg alloy has been irradiated under air and through a simulated body fluid (SBF) layer using a 500 watt pulsed Nd: YAG laser. As compared to direct laser surface treatment through air, laser irradiation through SBF generates new surface structures and deposition of ions issued from the SBF solution. Scanning electron microscope combined with energy dispersive spectroscopy (EDS) was used for the examination of surface structures formation and determination of elemental composition. Mesenchymal stem cells (MSC) culture was performed on laser modified WE54 alloy surface, and the MSC cytocompatibility on SBF-treated substrates was evaluated by the PrestoBlue™ assay test method. Cell reproducibility was observed on the SBF laser-treated surface which indicated that cell viability was improved by the surface treatment. The deposition of calcium and phosphorus ions on the WE54 surface was beneficial for cell viability. These results motivate the potential use of SBF-based films for biomedical purposes.
- 1 January 2016
- Published by Elsevier
Contributors
- 1 March 2012
- Published by AIP Publishing in Biomicrofluidics
- Vol. 6 (1) , 012820-1282012
Investigation on CO2 laser irradiation inducing glass strip peeling for microchannel formation
The study investigates the use of CO2 laser to induce glass strip peeling off to form microchannels on soda lime gass substrate. The strip peeling exhibits a strong dependence on the energy deposition rate on the glass surface. In spite of the vast difference in the combination of laser power and scanning speed, when the ratio of the two makes the energy deposition rate in the range 3.0-6.0 J/(cm2 s), the temperature rising inside glass will be above the strain point and reach the softening region of the glass. As a result, glass strip peeling is able to occur and form microchannels with dimensions of 20-40 μm in depth and 200-280 μm in width on the glass surface. Beyond this range, higher energy depsotion rate would lead to surface melting associated with solidification cracks and lower energy deposition rate causes the generation of fragment cracks.
- 1 March 2012
- Published by AIP Publishing in Biomicrofluidics
- Vol. 6 (1) , 012820-1282012
Investigation on CO2 laser irradiation inducing glass strip peeling for microchannel formation
The study investigates the use of CO2 laser to induce glass strip peeling off to form microchannels on soda lime gass substrate. The strip peeling exhibits a strong dependence on the energy deposition rate on the glass surface. In spite of the vast difference in the combination of laser power and scanning speed, when the ratio of the two makes the energy deposition rate in the range 3.0-6.0 J/(cm2 s), the temperature rising inside glass will be above the strain point and reach the softening region of the glass. As a result, glass strip peeling is able to occur and form microchannels with dimensions of 20-40 μm in depth and 200-280 μm in width on the glass surface. Beyond this range, higher energy depsotion rate would lead to surface melting associated with solidification cracks and lower energy deposition rate causes the generation of fragment cracks.
- 2 July 2010
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 10 (1) , 225-229
Femtosecond laser-induced modification of surface wettability of PMMA for fluid separation in microchannels
- 2 July 2010
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 10 (1) , 225-229
Femtosecond laser-induced modification of surface wettability of PMMA for fluid separation in microchannels