Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Fiona Li has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Cone Beam Computed Tomography (CBCT)-Based Online Adaptive Radiotherapy for Patients With Metal Implants: An Institutional Experience

    by Fiona Li, Sean Tanny, Wesley Rivais, Olga Dona Lemus, Alexander Podgorsak, Dandan Zheng

  • Top Cited Papers
    Open Access

    Boron Neutron Capture Therapy: A Technology-Driven Renaissance

    by Dandan Zheng, Guang Han, Olga Dona Maria Lemus, Alexander Podgorsak, Matthew Webster, Fiona Li, Yuwei Zhou, Hyunuk Jung, Jihyung Yoon

    Boron neutron capture therapy (BNCT) is experiencing a global resurgence driven by advances in boron pharmacology, accelerator-based neutron sources, and molecular imaging-guided theranostics. BNCT produces high linear energy transfer particles with micrometer-range energy deposition, enabling cell-selective irradiation confined to boron-enriched tumor cells in a geometrically targeted region by the neutron beam. This mechanism offers the potential for exceptionally high therapeutic ratios, provided two core requirements are met: sufficient differential tumor uptake of 10B and a neutron beam with appropriate energy and penetration. After early clinical attempts in the mid-20th century were hindered by inadequate boron agents and reactor-based neutron beams, recent technological breakthroughs have made BNCT clinically viable. The development of hospital-compatible accelerator neutron sources, next-generation boron delivery systems (such as receptor-targeted compounds and nanoparticles), advanced theranostic approaches (such as 18F-BPA positron emission tomography and boron-sensitive magnetic resonance imaging), and AI-driven biodistribution modeling now support personalized treatment planning and patient selection. These innovations have catalyzed modern clinical implementation, exemplified by Japan’s regulatory approval of BNCT for recurrent head and neck cancer and the rapid expansion of clinical programs across Asia, Europe, and South America. Building on these foundations, BNCT has transitioned from a predominantly academic experimental modality into an increasingly commercialized and industrially supported therapeutic platform. The emergence of dedicated BNCT companies, international collaborations between accelerator manufacturers and hospitals, and pharmaceutical development pipelines for next-generation boron carriers has accelerated clinical translation. Moreover, BNCT now occupies a unique position among radiation modalities due to its hybrid nature, namely combining the biological targeting of radiopharmaceutical therapy with the external-beam controllability of radiotherapy, thereby offering new therapeutic opportunities where competitive approaches fall short. Emerging evidence suggests therapeutic promise in glioblastoma, recurrent head and neck cancers, melanoma, meningioma, lung cancer, sarcomas, and other difficult-to-treat malignancies. Looking ahead, continued innovation in compact neutron source engineering, boron nanocarriers, multimodal theranostics, microdosimetry-guided treatment planning, and combination strategies with systemic therapies such as immunotherapy will be essential for optimizing outcomes. Together, these converging developments position BNCT as a biologically targeted and potentially transformative modality in the era of precision oncology.


  • Top Cited Papers
    Open Access

    New Approaches in Radiotherapy

    by Matthew Webster, Alexander Podgorsak, Fiona Li, Yuwei Zhou, Hyunuk Jung, Jihyung Yoon, Olga Dona Lemus, Dandan Zheng

    Radiotherapy (RT) has undergone transformative advancements since its inception over a century ago. This review highlights the most promising and impactful innovations shaping the current and future landscape of RT. Key technological advances include adaptive radiotherapy (ART), which tailors treatment to daily anatomical changes using integrated imaging and artificial intelligence (AI), and advanced image guidance systems, such as MR-LINACs, PET-LINACs, and surface-guided radiotherapy (SGRT), which enhance targeting precision and minimize collateral damage. AI and data science further support RT through automation, improved segmentation, dose prediction, and treatment planning. Emerging biological and targeted therapies, including boron neutron capture therapy (BNCT), radioimmunotherapy, and theranostics, represent the convergence of molecular targeting and radiotherapy, offering personalized treatment strategies. Particle therapies, notably proton and heavy ion RT, exploit the Bragg peak for precise tumor targeting while reducing normal tissue exposure. FLASH RT, delivering ultra-high dose rates, demonstrates promise in sparing normal tissue while maintaining tumor control, though clinical validation is ongoing. Spatially fractionated RT (SFRT), stereotactic techniques and brachytherapy are evolving to treat challenging tumor types with enhanced conformality and efficacy. Innovations such as 3D printing, Auger therapy, and hyperthermia are also contributing to individualized and site-specific solutions. Across these modalities, the integration of imaging, AI, and novel physics and biology-driven approaches is redefining the possibilities of cancer treatment. This review underscores the multidisciplinary and translational nature of modern RT, where physics, engineering, biology, and informatics intersect to improve patient outcomes. While many approaches are in various stages of clinical adoption and investigation, their collective impact promises to redefine the therapeutic boundaries of radiation oncology in the coming decade.


  • Open Access

    Clinical Practice-Based Failure Modes and Root Cause Analysis of Cone Beam CT-Guided Online Adaptive Radiotherapy of the Pelvis

    by Dandan Zheng, Michael Cummings, Hong Zhang, Alexander Podgorsak, Fiona Li, Olga Dona Lemus, Matthew Webster, Neil Joyce, Erika Hagenbach, Kevin Bylund, et al.

    Background/Objectives: Cone-beam computed tomography (CBCT)-guided online adaptive radiotherapy (oART) represents a significant advancement in radiation oncology, enabling on-couch plan adaptation to account for daily anatomical changes. While this automation improves precision and workflow efficiency, it also introduces new failure modes (FMs) and workflow irregularities. This study aimed to systematically evaluate the clinical and technical challenges associated with CBCT-guided oART implementation. Methods: We retrospectively analyzed over 1000 CBCT-guided oART sessions for pelvic malignancies performed at our institution. A multidisciplinary team conducted a comprehensive review to identify and classify FMs, followed by root cause analysis (RCA) to evaluate their impact on treatment safety, efficacy, and workflow robustness. Results: In addition to session-terminating FMs, we identified recurring failure modes across three major domains: (1) system-driven issues, such as rigid target localization and software-driven irregularities; (2) patient-driven challenges, including interfractional and intrafractional anatomical variations; and (3) treatment planning and execution failures, including excessive dose hotspots from field-of-view limitations. The system’s closed-loop automation, while streamlining processes, introduced rigid constraints in plan adaptation and fallback plan execution, occasionally leading to unintended dose discrepancies. Conclusions: This study provides a comprehensive clinical practice-based evaluation of CBCT-guided oART, highlighting system-specific failure modes and their implications. Addressing these challenges requires structured quality assurance processes, multidisciplinary collaboration, and continuous workflow refinement. Our findings contribute to the development of safer and more robust adaptive radiotherapy platforms and clinical workflows.


  • Synthetic CT for gamma knife radiosurgery dose calculation: A feasibility study

    by Fiona Li, Yuanguang Xu, Olga D. Lemus, Tony J.C. Wang, Michael B. Sisti, Cheng-Shie Wuu

  • Open Access

    Commissioning of Mobius3D/FX for patient‐specific quality assurance: The CUIMC—NewYork Presbyterian Hospital experience

    by Fiona Li, Michael Price

    Purpose: To present the process undertaken by our institute in commissioning Mobius3D (M3D) for patient‐specific quality assurance.Method: 168 plans were randomly selected to compare dose distribution measured with ArcCheck and dose calculated from M3D, both compared against the treatment planning system (TPS). The gamma criteria for measurement and M3D are 3%/2 mm with 10% and 50% dose thresholds, respectively. The effect of tissue inhomogeneity was investigated on 11 plans by recalculating the dose in M3D on a homogeneous phantom. Tolerance and action limits were established following the AAPM Task Group 218 recommendations.Results: The M3D showed high variability in gamma passing rate compared to the measurement. Twenty‐three out of 168 plans had false negative dose comparisons. These plans fall under high tissue inhomogeneity like lung and metal implants, small field targets, and breast plans planned with high energy. One false negative case (0.6%) was observed. A single tolerance limit of 91% and 92% gamma passing rate for the M3D and measurement‐based PSQA were established, respectively. Against the expectation, recalculating plans on the homogeneous phantom in M3D did not necessarily increase the gamma passing rate. These plans have a duty cycle >4.2, and the small field sizes combined with differences in slice thickness contributed to observed dose differences in the homogeneous phantom comparisons.Conclusion: Following the commissioning, M3D is adopted in our institute. Currently, the gamma criteria used for measurement and M3D are 3%/2 mm, 40% dose threshold, with gamma passing rates of 92% and 95%, respectively. A higher passing rate for M3D is adopted until more data is available. The combined effect of plan modulation, the field sizes, the tissue inhomogeneity, the dose algorithm, and the volume averaging effect from differences in slice thickness can contribute to the differences in dose in M3D and TPS.


  • Open Access

    Plasma radio–metabolite analysis of PET tracers for dynamic PET imaging: TLC and autoradiography

    by Fiona Li, Justin W Hicks, Lihai Yu, Lise Desjardin, Laura Morrison, Jennifer Hadway, Ting-Yim Lee

    Background In molecular imaging with dynamic PET, the binding and dissociation of a targeted tracer is characterized by kinetics modeling which requires the arterial concentration of the tracer to be measured accurately. Once in the body the radiolabeled parent tracer may be subjected to hydrolysis, demethylation/dealkylation and other biochemical processes, resulting in the production and accumulation of different metabolites in blood which can be labeled with the same PET radionuclide as the parent. Since these radio-metabolites cannot be distinguished by PET scanning from the parent tracer, their contribution to the arterial concentration curve has to be removed for the accurate estimation of kinetic parameters from kinetic analysis of dynamic PET. High performance liquid chromatography has been used to separate and measure radio-metabolites in blood plasma, however, the method is labor intensive and remains a challenge to implement for each individual patient. The purpose of this study is to develop an alternate technique based on thin layer chromatography (TLC) and a sensitive commercial autoradiography system (Beaver, Ai4R, Nantes, France) to measure radio-metabolites in blood plasma of two targeted tracers - [ 18 F]FAZA and [ 18 F]FEPPA , for imaging hypoxia and inflammation respectively. Results Radioactivity as low as 17Bq in 2µL of pig’s plasma can be detected on the TLC plate using autoradiography. Peaks corresponding to the parent tracer and radio-metabolites could be distinguished in the line profile through each sample (n=8) in the autoradiographic image. Significant inter-subject and intra-subject variability in radio-metabolites production could be observed with both tracers. For [ 18 F]FEPPA, 50% of plasma activity was from radio-metabolites as early as 5 min post injection while for [ 18 F]FAZA, significant metabolites did not appear until 50 min post. Simulation study investigating the effect of radio-metabolite in the estimation of kinetic parameters indicated that 32-400% parameter error can result without radio-metabolites correction. Conclusion TLC coupled with autoradiography is a good alternative to high performance liquid chromatography for radio-metabolite correction. The advantages of requiring only small blood samples (~ 100 μL) and of analyzing multiple samples simultaneously, make the method suitable for individual dynamic PET studies.

  • Open Access

    Pharmacokinetic Analysis of Dynamic [18F]FAZA PET Imaging in Pancreatic Cancer Patient

    by Fiona Li, Edward Taylor, Ivan Yeung, David Jaffray, Ur Metser, Neesha Dhani, David W Hedley, Ting-Yim Lee

    Purpose This study assessed the pharmacokinetics of the hypoxia PET tracer, [18F]fluoroazomycin arabinoside ([18F]FAZA), in pancreatic cancer (PCa) patients and determined the optimal kinetic parameters to distinguish cancerous from normal pancreatic tissue. Method Twenty patients with pancreatic ductal adenocarcinoma underwent dynamic [ 18 F]FAZA scans. The tissue time activity curve (TAC) was analyzed using graphical methods to determine reversibility of tracer binding and with standard compartment (S2TC) model and flow modified two tissue compartment (F2TC) model, developed to incorporate transit time of tracer through the blood vessel, to estimate the kinetic parameters. The optimal parameter set to distinguish hypoxic tumors from normal tissues was determined using logistic regression. Results Both graphical and kinetic model analysis indicated that tracer was reversibly bound. According to the Akaike Information Criteria, the F2TC model fitted the tumor TAC better than the S2TC model. Total distribution volume, V T , estimated by the F2TC model for both tumor and normal pancreatic tissue was not significant but that estimated by the S2TC model was significantly different from Logan graphical analysis. The extravascular distribution volume ( DV ) and tracer dissociation rate constant ( k 4 ) can classify hypoxic PCa from normal tissue with sensitivity of 95% and negative predictive value of 89% (P<0.01). Conclusions Kinetic analysis of dynamic [ 18 F]FAZA PET can distinguish PCa from normal tissue with high sensitivity. The reversibility of [ 18 F]FAZA binding in hypoxic cells could be due to glutathionylation of the nitroreductase reduced products and their subsequent efflux from same cells via the ATP mediated multidrug resistant protein (MRP-1) efflux pump.