HJHyunuk Jung

Hyunuk Jung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hyunuk Jung has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative phantom‐based comparison of commercial CT metal artifact reduction algorithms

    by Beechui Koo, Daehong Kim, Hyunuk Jung, Mitchell Polizzi, Indra J. Das, Siyong Kim, James J. Sohn

    Background: Metal artifacts in computed tomography (CT) significantly compromise image quality and CT number (CTN) accuracy, which may influence downstream applications such as radiation therapy workflows. Although commercial metal artifact reduction (MAR) algorithms are widely used, their performance varies across vendors and clinical scenarios, and standardized methods for quantitative comparison remain limited. Purpose: This study quantitatively compares four commercial MAR algorithms using standardized metrics and a novel analytical approach. Methods: A custom‐designed resin phantom with interchangeable inserts (solid water, aluminum, titanium, and stainless steel) was scanned using four CT systems: Canon, GE, Philips, and Siemens. Each system's proprietary MAR algorithm was applied to obtain artifact‐reduced image sets. Quantitative analysis employed complementary methods: (1) circular profile analysis measuring mean CTN deviations at concentric distances from metal objects; (2) geometric accuracy assessment of metal objects; and (3) volumetric artifact characterization using analysis of severe artifact voxels and composite error metric ( M ‐error index) that integrates both artifact extent and intensity. Color maps and accumulated histograms of ΔCTN values between pre‐ and post‐MAR images were used to characterized artifact patterns and MAR performance. Results: All four MAR methods showed minimal |ΔCTN| at mid (2.80 cm) and far (3.80 cm) distances but showed pronounced increases in |ΔCTN| near the metal interface at the closest radius (1.27 cm). Smart‐MAR exhibited the highest CTN deviation for aluminum (16.83 HU), while O‐MAR showed the largest deviations for titanium and stainless steel (42.40 and 42.60 HU). Quantitative evaluation showed that single‐energy metal artifact reduction (SEMAR) and iterative metal artifact reduction (iMAR) achieved the most consistent geometric accuracy (M Error values (0.00–0.83) than O‐MAR, which showed significantly higher values (1.15–2.45). Conclusion: SEMAR and iMAR achieved the most consistent geometric accuracy (<5% error) and artifact suppression across all metals, while O‐MAR demonstrated material‐dependent performance with substantial residual artifacts near metal interfaces. These phantom‐based benchmarks provide vendor‐neutral performance data on MAR performance under controlled settings.

  • Top Cited Papers
    Open Access

    Boron Neutron Capture Therapy: A Technology-Driven Renaissance

    by Dandan Zheng, Guang Han, Olga Dona Maria Lemus, Alexander Podgorsak, Matthew Webster, Fiona Li, Yuwei Zhou, Hyunuk Jung, Jihyung Yoon

    Boron neutron capture therapy (BNCT) is experiencing a global resurgence driven by advances in boron pharmacology, accelerator-based neutron sources, and molecular imaging-guided theranostics. BNCT produces high linear energy transfer particles with micrometer-range energy deposition, enabling cell-selective irradiation confined to boron-enriched tumor cells in a geometrically targeted region by the neutron beam. This mechanism offers the potential for exceptionally high therapeutic ratios, provided two core requirements are met: sufficient differential tumor uptake of 10B and a neutron beam with appropriate energy and penetration. After early clinical attempts in the mid-20th century were hindered by inadequate boron agents and reactor-based neutron beams, recent technological breakthroughs have made BNCT clinically viable. The development of hospital-compatible accelerator neutron sources, next-generation boron delivery systems (such as receptor-targeted compounds and nanoparticles), advanced theranostic approaches (such as 18F-BPA positron emission tomography and boron-sensitive magnetic resonance imaging), and AI-driven biodistribution modeling now support personalized treatment planning and patient selection. These innovations have catalyzed modern clinical implementation, exemplified by Japan’s regulatory approval of BNCT for recurrent head and neck cancer and the rapid expansion of clinical programs across Asia, Europe, and South America. Building on these foundations, BNCT has transitioned from a predominantly academic experimental modality into an increasingly commercialized and industrially supported therapeutic platform. The emergence of dedicated BNCT companies, international collaborations between accelerator manufacturers and hospitals, and pharmaceutical development pipelines for next-generation boron carriers has accelerated clinical translation. Moreover, BNCT now occupies a unique position among radiation modalities due to its hybrid nature, namely combining the biological targeting of radiopharmaceutical therapy with the external-beam controllability of radiotherapy, thereby offering new therapeutic opportunities where competitive approaches fall short. Emerging evidence suggests therapeutic promise in glioblastoma, recurrent head and neck cancers, melanoma, meningioma, lung cancer, sarcomas, and other difficult-to-treat malignancies. Looking ahead, continued innovation in compact neutron source engineering, boron nanocarriers, multimodal theranostics, microdosimetry-guided treatment planning, and combination strategies with systemic therapies such as immunotherapy will be essential for optimizing outcomes. Together, these converging developments position BNCT as a biologically targeted and potentially transformative modality in the era of precision oncology.


  • Top Cited Papers
    Open Access

    New Approaches in Radiotherapy

    by Matthew Webster, Alexander Podgorsak, Fiona Li, Yuwei Zhou, Hyunuk Jung, Jihyung Yoon, Olga Dona Lemus, Dandan Zheng

    Radiotherapy (RT) has undergone transformative advancements since its inception over a century ago. This review highlights the most promising and impactful innovations shaping the current and future landscape of RT. Key technological advances include adaptive radiotherapy (ART), which tailors treatment to daily anatomical changes using integrated imaging and artificial intelligence (AI), and advanced image guidance systems, such as MR-LINACs, PET-LINACs, and surface-guided radiotherapy (SGRT), which enhance targeting precision and minimize collateral damage. AI and data science further support RT through automation, improved segmentation, dose prediction, and treatment planning. Emerging biological and targeted therapies, including boron neutron capture therapy (BNCT), radioimmunotherapy, and theranostics, represent the convergence of molecular targeting and radiotherapy, offering personalized treatment strategies. Particle therapies, notably proton and heavy ion RT, exploit the Bragg peak for precise tumor targeting while reducing normal tissue exposure. FLASH RT, delivering ultra-high dose rates, demonstrates promise in sparing normal tissue while maintaining tumor control, though clinical validation is ongoing. Spatially fractionated RT (SFRT), stereotactic techniques and brachytherapy are evolving to treat challenging tumor types with enhanced conformality and efficacy. Innovations such as 3D printing, Auger therapy, and hyperthermia are also contributing to individualized and site-specific solutions. Across these modalities, the integration of imaging, AI, and novel physics and biology-driven approaches is redefining the possibilities of cancer treatment. This review underscores the multidisciplinary and translational nature of modern RT, where physics, engineering, biology, and informatics intersect to improve patient outcomes. While many approaches are in various stages of clinical adoption and investigation, their collective impact promises to redefine the therapeutic boundaries of radiation oncology in the coming decade.


  • Open Access

    Dosimetric evaluation of LINAC-based single-isocenter multi-target multi-fraction stereotactic radiosurgery with more than 20 targets: comparing MME, HyperArc, and RapidArc

    by Hyunuk Jung, Jihyung Yoon, Olga Dona Lemus, Sean Tanny, Yuwei Zhou, Michael Milano, Kenneth Usuki, Sara Hardy, Dandan Zheng

    Background: To compare the dosimetric quality of three widely used techniques for LINAC-based single-isocenter multi-target multi-fraction stereotactic radiosurgery (fSRS) with more than 20 targets: dynamic conformal arc (DCA) in BrainLAB Multiple Metastases Elements (MME) module and volumetric modulated arc therapy (VMAT) using RapidArc (RA) and HyperArc (HA) in Varian Eclipse. Methods: Ten patients who received single-isocenter fSRS with 20–37 targets were retrospectively replanned using MME, RA, and HA. Various dosimetric parameters, such as conformity index (CI), Paddick CI, gradient index (GI), normal brain dose exposures, maximum organ-at-risk (OAR) doses, and beam-on times were extracted and compared among the three techniques. Wilcoxon signed-rank test was used for statistical analysis. Results: All plans achieved the prescribed dose coverage goal of at least 95% of the planning target volume (PTV). HA plans showed superior conformity compared to RA and MME plans. MME plans showed superior GI compared to RA and HA plans. RA plans resulted in significantly higher low and intermediate dose exposure to normal brain compared to HA and MME plans, especially for lower doses of ≥ 8Gy and ≥ 5Gy. No significant differences were observed in the maximum dose to OARs among the three techniques. The beam-on time of MME plans was about two times longer than RA and HA plans. Conclusions: HA plans achieved the best conformity, while MME plans achieved the best dose fall-off for LINAC-based single-isocenter multi-target multi-fraction SRS with more than 20 targets. The choice of the optimal technique should consider the trade-offs between dosimetric quality, beam-on time, and planning effort.