RARodianah Alias

Rodianah Alias

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rodianah Alias has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Statistical Analysis of the Deposition Parameters of Multilayer AgO/Ag–TaO/TaO Thin Films on an SS316L Substrate

    by Mohd Amirul, Rodianah Alias, Muhammad Rizwan, W.N.F Mohamad, Abd Rahman Z., M. S. Hamid, Afifah Juri, Mohd Faizal Ali Akhbar, Abd Razak Bushroa

    Surgical instruments designed for high performance require coatings with strong mechanical properties, water-repellent features and compatibility with biological tissues to minimise interactions with bodily fluids during surgery. In this study, the structural and surface characteristics of multilayer AgO/Ag–TaO/TaO thin films deposited on a stainless steel 316L (SS316L) substrate by physical vapor deposition magnetron sputtering were investigated as functions of various deposition parameters. The effect of AgO deposition time and radiofrequency (RF) sputtering power was studied by using a central composite design with response surface methodology. Results demonstrate a significant correlation between the predicted and actual values of adhesion strength (R2 = 0.9105), confirming the adequacy of the model. Adhesion strength was significantly affected by RF sputtering power then by deposition time. Wettability was also influenced by these parameters. Interaction plots show enhanced wettability at certain RF power levels, with a maximum contact angle of 89.6°. The optimal adhesion strength was obtained under specific RF power and deposition time conditions, with a maximum scratch distance of 705 mN. This work provides useful insights into the role of deposition parameters in tailoring the performance of thin films for biomedical and industrial applications.

  • Optimization of Surgical Drill Margin Dimension to Reduce Bone Temperature

    by Mohd Faizal Ali Akhbar, Shahrizan Jamaludin, Rodianah Alias

    Excessive heat generation during bone drilling is a leading cause of thermal osteonecrosis—a serious risk in medical departments. Despite extensive drill design research, the influence of margin geometry remains underexplored. This study presents finite element modeling and statistical optimization to evaluate and optimize drill margin geometry—specifically margin width ( Mw ) and height ( Mh )—to reduce bone temperature rise during surgery. A thermo-mechanical finite element model was developed in DEFORM-3D to simulate cortical bone drilling using drill bits with varied margin dimensions. The models were validated experimentally using bovine cortical bone, with an average temperature prediction errors of 2.4–8.0%. The maximum bone temperature ( T max ) was selected as the objective function. A central composite design (CCD) was applied to generate experimental runs, followed by response surface methodology (RSM) and desirability-based optimization. The second-order effect of Mw contributed 47.2% to T max . The optimal Mh (0.05 mm) and Mw (0.22 mm)—with a desirability value of 0.985—could reduce T max below the osteonecrosis level with only a 44.8 °C temperature rise. This study demonstrates a novel computational approach for optimizing surgical drill margins—a previously underutilized parameter. The findings may support future developments in drill bit customization and robotic surgery systems to minimize thermal injury to bone cells.


  • Open Access

    Optimization of Drill Bit Geometries for Minimum Thermal Damage in Bone Drilling

    by Mohd Faizal Ali Akhbar, Mohamad Faris Mohd Ashri, Ahmad Razlan Yusoff, Shahrizan Jamaludin, Rodianah Alias, Fatin Alias, Razhan Hassan, Muhammad Rizwan

    Thermal injury is a common post-operative effect in bone drilling surgeries. The extreme heat generated during the drilling process kills bone cells, which causes irreversible bone death. This bone death loosens medical fixations—screws, plates, and implants—and subsequently refractures the bone. Research on drill bit geometries in bone drilling has attracted interest from engineering and medical researchers. However, previous research has mainly focused on the simulation of bone drilling, which could generate an incorrect approximation of thermal bone damage if the simulation model is not validated. For this reason, this study focuses on the optimization and parametric analysis of the bone temperature elevations induced by customized drill bit features—point angle (60-180°), web thickness (25-50 %), and helix angle (10-55°)—in comprehensive ex-vivo bone (bovine) experimental drilling tests. The L9 Taguchi optimization method was then applied to determine the optimal design to minimize maximum bone temperature rise. Results from the parametric analysis revealed that the optimal setup for the drill point features can be obtained with the ranges of point angle of 160-180°, web thickness of 25-30 %, and helix angle of 30-40°. Based on the Taguchi optimization results, the minimum thermal damage is produced with the point angle of 180°, web thickness of 25 %, and helix angle of 35°. This work offers a promising solution for reducing thermal injury and preventing thermal osteonecrosis in bone drilling surgeries.


  • Physico-chemical and antimicrobial properties of Ag/Ta2O5 nanocomposite coatings

    by Rodianah Alias, Muhammad Rizwan, Reza Mahmoodian, K.M. Vellasamy, Mohd Hamdi


  • Open Access

    Bioglass-fibre reinforced hydroxyapatite composites synthesized using spark plasma sintering for bone tissue engineering

    by Muhammad Rizwan, Ali Dad Chandio, Muhammad Sohail, Nasir M. Bashir, Sumra Yousuf, Rodianah Alias, Hammad Ur Rehman, M. Hamdi, Jeffrey Wan Basirun

    Hydroxyapatite (HA) exhibits several desirable characteristics, but it still lacks osteoinduction, which is a necessary requirement for a bone scaffold. HA-based composites with different amounts of Bioglass? (BG) were prepared using spark plasma sintering (SPS). Careful selection of the SPS parameters avoided undesirable reactions between the calcium phosphate (CaP) and bioglass (BG present in the form of powder and fibres), as confirmed through X-ray diffraction analysis. Scanning electron microscopy images of the composite scaffolds revealed a fibre like appearance of the glassy region. The in vitro bioactivity and biodegradation analyses were performed by immersing the composites in simulated body fluid (SBF) and tris(hydroxymethyl)aminomethane (Tris), respectively. The ability to obtain only the CaP phase and glassy phase with desirable bioactive and biodegradation behaviour, indicated that these SPS scaffolds can be employed as bone scaffolds for clinical trials, after further in vivo analyses.


  • Synthesis, Characterization, and In Vitro Biochemical Analysis of Hydroxyapatite–Bioglass® Composite Scaffolds for Bone Tissue Repair

    by Muhammad Rizwan, Sumra Yousuf, Muhammad Sohail, M. Nasir Bashir, Rodianah Alias, M. Hamdi, Wan Jeffrey Basirun

  • Open Access

    In vitro evaluation of novel low-pressure spark plasma sintered HA–BG composite scaffolds for bone tissue engineering

    by Muhammad Rizwan, Krishnamurithy Genasan, Malliga Raman Murali, Hanumantha Rao Balaji Raghavendran, Rodianah Alias, Yi Ying Cheok, Won Fen Wong, Azura Mansor, M. Hamdi, Wan Jeffrey Basirun, et al.

    The low-pressure spark plasma sintering (SPS) technique is adopted to fabricate hydroxyapatite–bioglass (HA–BG) scaffolds while maintaining the physical properties of both components, including their bulk and relative density and hardness. However, prior to their orthopaedic and dental applications, these scaffolds must be validated via pre-clinical assessments. In the present study, scaffolds with different ratios of HA : BG, namely, 100 : 0 (HB 0 S), 90 : 10 (HB 10 S), 80 : 20 (HB 20 S) and 70 : 30 (HB 30 S) were fabricated. These scaffolds were characterized by investigating their physicochemical properties (X-ray diffraction (XRD) and surface wettability), bioactivity in a simulated body fluid (SBF) (field emission scanning electron microscopy (FESEM), Fourier-transform infrared spectroscopy (FTIR) and calcium dissolution), antimicrobial properties, biocompatibility and osteoinduction of human bone marrow-derived mesenchymal stromal cells (hBMSCs) and human monocyte immune cell response. The XRD and surface wettability results confirmed no formation of undesirable phases and the enhanced surface hydrophilicity of the scaffolds, respectively. The bioactivity in SBF indicated the formation of bone-like apatite on the surface of the scaffolds, corresponding to an increase in BG%, which was confirmed through FTIR spectra and the increasing trend of calcium release in SBF. The scaffolds showed inhibition properties against Staphylococcus aureus and Staphylococcus epidermidis. The scanning electron microscopy (SEM) micrographs and Alamar Blue proliferation assay indicated the good attachment and significant proliferation, respectively, of hBMSCs on the scaffolds. Alizarin Red S staining confirmed that the scaffolds supported the mineralisation of hBMSCs. The osteogenic protein secretion (bone morphogenetic protein-2 (BMP2), type-I collagen (COL1) and osterix (OSX)) was significant on the HB 30 S-seeded hBMSCs when compared with that of HB 0 S. The monocyte migration was significantly halted in response to HA–BG-conditioned media when compared with the positive control (monocyte chemoattractant protein-1: MCP-1). In conclusion, the HB 30 S composite scaffold has a greater potential to substitute bone grafts in orthopaedic and dental applications.


  • Study the effect of thermal annealing on adhesion strength of Silver-Tantalum Oxide thin film deposited by reactive magnetron sputtering

    by Rodianah Alias, Reza Mahmoodian, Muhammad Rizwan, Mohd Hamdi Abd Shukor

    Stainless steel (SS) are extensively used for healthcare, hygiene and surgical applications due to their excellent corrosion resistance and adequate mechanical strength. Among this class SS 316 L is employed most widely, due to highest corrosion resistance, good mechanical properties, resistance to sensitization and ease of fabrication. To incorporate antimicrobial characteristic in SS 316 L based surgical tools a nanocomposite layer comprising of Silver (Ag) and Tantalum oxide (TaxOx) has been deposited by using Physical Vapor Deposition (PVD) magnetron sputtering. Delamination of ceramic layers on SS 316 L substrate is one of the major limitation arising from insufficient crystallization and poor adhesion strength. PVD magnetron sputtering has been employed to develop 5.49 µm thick Ag-TaxOx nanocomposite layer on SS 316 L. Substantially improved adhesion strength has been achieved by controlling thermal treatment. The microstructure, surface and phase analysis of as-sputtered and annealed thin films has been carried out to determine the characteristics of the developed layer. A nanocomposite layer on SS 316 L substrate comprising of Ag and TaxOx has been achieved by releasing O2 during deposition. Thermal treatment was performed at 300, 400, 500 and 600 °C which progressively increased the crystallinity and segregation of Ag at the surface. Highest adhesion strength was achieved by annealing the coated samples at 400 °C, which exhibited four-fold increased adhesion strength when compared to as-deposited layer. The precipitation of a new phase Silver tantalum oxide (AgTaO3) was observed for the samples annealed at temperature above 400 °C, which may be responsible for the decrease in adhesion strength.