XWXuechun Wang

Xuechun Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xuechun Wang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Systematic evaluation of surgical insertion of flexible neural probe arrays into deeper brain targets using length modulation methods

    by Yingyi Gao, Zhouxiao Lu, Xuechun Wang, Zihan Jin, Alberto Esteban Linares, Jeffery Guo, Huijing Xu, Kee Scholten, Dong Song, Ellis Meng

    Objective. Penetrating polymer-based microelectrode arrays (pMEAs) offer the potential for long term high-quality electrophysiological recordings of dynamic neural activity. Compared to rigid metal wire and silicon MEAs, improved device-tissue interface stability has been reported. However, accurate surgical placement of long, thin shanks in deeper brain regions is challenging as flexibility is achieved at the expense of axial stiffness. This study systematically evaluates then compares two pMEA placement strategies—dissolvable dip coating and molded brace, both with bare, exposed pMEA tips— to address the need for consistent, reliable, and accurate surgical targeting. These methods were selected based on the criteria of ease of fabrication, surgical feasibility, and mechanical performance. Approach. Sham (mechanical model with no electrodes) and fully functional pMEAs with shanks up to 5.5 mm long were fabricated and then modified using biodegradable polyethylene glycol (PEG) to support implantation. PEG was applied to shanks by motorized dip coating or a mechanical mold. Dissolution time and insertion in agarose gel brain models and rat cortex were evaluated followed by targeting of dip coated pMEAs to the rat hippocampus. Main results. Dip coating at high withdrawal speeds achieved uniform coating on shanks. Both strategies yielded similar critical buckling forces and insertion forces for single shank and arrayed pMEAs. Dip coated pMEAs were successfully placed in hippocampal regions without severe tissue damage as confirmed by histology and recordings obtained. Significance. Dip coating is a simpler method to prepare pMEAs for surgical targeting of deep brain regions compared to the bracing technique, as it does not require both a specialized mold and application process. This work provides a guide for researchers using single or multi-shank pMEAs to an accessible insertion strategy for implanting into deep brain regions in rodents and other small animal models.


  • Reconfigurable mixed-kernel heterojunction transistors for personalized support vector machine classification

    by Xiaodong Yan, Justin H. Qian, Jiahui Ma, Aoyang Zhang, Stephanie E. Liu, Matthew P. Bland, Kevin J. Liu, Xuechun Wang, Vinod K. Sangwan, Han Wang, et al.


  • A Microfabricated Nanobubble-Based Sensor for Physiological Pressure Monitoring

    by Xuechun Wang, Eugene Yoon, Ellis Meng

    A microfabricated nanobubble-based sensor was developed for real-time physiological pressure monitoring. The fully immersed sensor utilizes an electrolytic bubble generated and localized within a microfluidic channel that is in communication with the local environment. Bubble size varies with local pressure changes, allowing pressure to be monitored by tracking the resulting electrochemical impedance changes. An asymmetric electrode pair bubble generator design achieved precise picoliter-volume bubble control using either oxygen or hydrogen gas. Precise pressure monitoring down to a resolution of 1 mmHg (0.13-kPa) was achieved using long-lasting ( $>$ 4 hours) oxygen bubbles tracked under a quasi-stable regime bounded by distinct, traceable bubble-channel wall detachment interac-tions. This corresponds to a 20 $\times$ improvement in resolution compared to microbubble-based pressure sensors reported to date. 2023-0077


  • A Parylene Neural Probe Array for Multi-Region Deep Brain Recordings

    by Xuechun Wang, Ahuva Weltman Hirschberg, Huijing Xu, Zachary Slingsby-Smith, Aziliz Lecomte, Kee Scholten, Dong Song, Ellis Meng

    A Parylene C polymer neural probe array with 64 electrodes purposefully positioned across 8 individual shanks to anatomically match specific regions of the hippocampus was designed, fabricated, characterized, and implemented in vivo for enabling recording in deep brain regions in freely moving rats. Thin film polymer arrays were fabricated using surface micromachining techniques and mechanically braced to prevent buckling during surgical implantation. Importantly, the mechanical bracing technique developed in this work involves a novel biodegradable polymer brace that temporarily reduces shank length and consequently, increases its stiffness during implantation, therefore enabling access to deeper brain regions while preserving a low original cross-sectional area of the shanks. The resulting mechanical properties of braced shanks were evaluated at the benchtop. Arrays were then implemented in vivo in freely moving rats, achieving both acute and chronic recordings from the pyramidal cells in the cornu ammonis (CA) 1 and CA3 regions of the hippocampus which are responsible for memory encoding. This work demonstrated the potential for minimally invasive polymer-based neural probe arrays for multi-region recording in deep brain structures. [2020-0018]


  • Identification of Proteus genomic island 2 variants in two clonal Proteus mirabilis isolates with coexistence of a novel genomic resistance island PmGRI1

    by Chang-Wei Lei, Tian-Ge Yao, Jia Yan, Bo-Yang Li, Xue-Chun Wang, Yu Zhang, Yu-Feng Gao, Hong-Ning Wang

    Objectives: To characterize the MDR genomic islands (GIs) in Proteus mirabilis isolates.Methods: Two P. mirabilis strains (C55 and C74) of chicken origin were subjected to WGS (HiSeq and PacBio) and the MDR GIs were determined.Results: P. mirabilis strains C55 and C74 are clonal strains and harbour different Proteus genomic island 2 (PGI2) variants (PGI2-C55 and PGI2-C74). The MDR region of PGI2-C55 is composed of two class 1 integrons, separated by a region containing seven copies of IS26 and eight resistance genes, including blaCTX-M-3 and fosA3. The region in PGI2-C74 is a complete In4-type class 1 integron, harbouring five gene cassettes (dfrA16, blaCARB-2, aadA2, cmlA1 and aadA1). In addition, C55 and C74 carry an SXT/R391 integrative and conjugative element (ICEPmiJpn1), harbouring blaCMY-2, and a novel 50.46 kb genomic resistance island named PmGRI1-C55. PmGRI1-C55 harbours a tyrosine-type recombinase/integrase that might be responsible for the integration of PmGRI1-C55 at the 3′ end of tRNA-Sec. It carries an MDR region derived from Tn2670 that harbours a Tn21 region and carries six resistance genes (catA1, blaTEM-1b, aphA1a, sul2, strA and strB). Blast analysis showed diverse PmGRI1 variants in P. mirabilis and Escherichia coli strains.Conclusions: The finding of the two new PGI2 variants highlights that the homologous recombination between shared components of class 1 integrons and transposition by IS26 promote the diversity of MDR regions in PGI2. PmGRI1 is a new GI that carries various resistance genes identified in P. mirabilis and E. coli.