Sonja Schickhardt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sonja Schickhardt has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Gerd Uwe Auffarth
International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, INF 400, 69120 Heidelberg, Germany
9 shared publications - Patrick Merz
David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
5 shared publications - Ramin Khoramnia
The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany
5 shared publications - Lu Zhang
David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Im Neuenheimer Feld 400, Heidelberg 69120, Germany
4 shared publications - Timur Mert Yildirim
Universitätsklinikum Heidelberg
4 shared publications - Donald John Munro
The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany
3 shared publications
Latest Publications
- Open Access
- 30 May 2024
- Published by Wiley in Journal of Ophthalmology
- Vol. 2024, 1-8
Evaluation of Parameters and Nozzle Tip Damage after Clinical Use of Three Hydrophilic Intraocular Lens Injector Models
Purpose. To assess the nozzle tip damage and the parameters of three different hydrophilic intraocular lens (IOL) injector models. Methods. After routine cataract surgeries at the University Eye Hospital Heidelberg, all the used IOL injectors were collected from the operating room and sent to our laboratory. Nozzle tip damage was assessed under a microscope and graded as follows: no damage (grade 0), slight scratches (1), deep scratches (2), extensions (3), cracks (4), and bursts (5). Each damage grade was assigned a score from 0 to 5, and the total damage score for each injector system was calculated and compared. Nozzle tip parameters (diameters and areas), plunger tip parameters, and tip angles were also measured in each model. Results. The damage scores were (median, Q3-Q1): 1 (1-1) for Accuject, 1 (1-1) for Bluemixs, and 1 (1-1) for RayOne. There was no statistically significant difference in the damage scores between the study groups ( ). The outer cross-sectional vertical and horizontal diameters were 1.69 and 1.69 mm for Accuject, 1.69 and 1.69 mm for Bluemixs, and 1.70 and 1.71 mm for RayOne. Plunger tip areas were 0.78 mm2 for Accjuect, 0.74 mm2 for Bluemixs, and 0.43 mm2 for RayOne. Plunger tip area/inner cross-sectional area of the nozzle tip (%) was 31.2% for RayOne, 66.7% for Accuject, and 63.8% for Bluemixs. The tip angles for three injector models were 56° (Accuject), 56° (Bluemixs), and 44° (RayOne). Conclusions. All the injector models showed mild to moderate damage to the nozzle tip after IOL implantation, even with smaller diameter tips. RayOne resulted in the lowest ratio between plunger tip area and inner cross-sectional area of the nozzle tip and a better distribution of damage categories than the other two groups. All three injector models had relatively small tip parameters. If smaller incisions are required in certain patients, smaller tip parameters should be considered.
- 30 May 2024
- Published by Wiley in Journal of Ophthalmology
- Vol. 2024, 1-8
Open AccessEvaluation of Parameters and Nozzle Tip Damage after Clinical Use of Three Hydrophilic Intraocular Lens Injector Models
Purpose. To assess the nozzle tip damage and the parameters of three different hydrophilic intraocular lens (IOL) injector models. Methods. After routine cataract surgeries at the University Eye Hospital Heidelberg, all the used IOL injectors were collected from the operating room and sent to our laboratory. Nozzle tip damage was assessed under a microscope and graded as follows: no damage (grade 0), slight scratches (1), deep scratches (2), extensions (3), cracks (4), and bursts (5). Each damage grade was assigned a score from 0 to 5, and the total damage score for each injector system was calculated and compared. Nozzle tip parameters (diameters and areas), plunger tip parameters, and tip angles were also measured in each model. Results. The damage scores were (median, Q3-Q1): 1 (1-1) for Accuject, 1 (1-1) for Bluemixs, and 1 (1-1) for RayOne. There was no statistically significant difference in the damage scores between the study groups ( ). The outer cross-sectional vertical and horizontal diameters were 1.69 and 1.69 mm for Accuject, 1.69 and 1.69 mm for Bluemixs, and 1.70 and 1.71 mm for RayOne. Plunger tip areas were 0.78 mm2 for Accjuect, 0.74 mm2 for Bluemixs, and 0.43 mm2 for RayOne. Plunger tip area/inner cross-sectional area of the nozzle tip (%) was 31.2% for RayOne, 66.7% for Accuject, and 63.8% for Bluemixs. The tip angles for three injector models were 56° (Accuject), 56° (Bluemixs), and 44° (RayOne). Conclusions. All the injector models showed mild to moderate damage to the nozzle tip after IOL implantation, even with smaller diameter tips. RayOne resulted in the lowest ratio between plunger tip area and inner cross-sectional area of the nozzle tip and a better distribution of damage categories than the other two groups. All three injector models had relatively small tip parameters. If smaller incisions are required in certain patients, smaller tip parameters should be considered.
- Open Access
- 3 January 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106368
In-vitro assessment of a novel intraocular lens made of crosslinked polyisobutylene
- 3 January 2024
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 152, 106368
Open AccessIn-vitro assessment of a novel intraocular lens made of crosslinked polyisobutylene
- Open Access
- 17 November 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (12) , 2183-2188
Capsule Dynamics, Implantation, and Explantation of the Smaller Incision, New-Generation Implantable Miniature Telescope: a Miyake–Apple Study
Purpose: The smaller incision, new-generation implantable miniature telescope is a novel implant to optimize vision in retinal patients with central vision loss. Using Miyake–Apple techniques we visualized the device implantation, repositioning, and explantation, while noting capsular bag dynamics. Methods: Using the Miyake–Apple technique, we assessed capsular bag deformation after successful implantation of the device in human autopsy eyes. We assessed rescue strategies for converting a sulcus implantation to a capsular implantation and explantation strategies. We noted the occurrence of posterior capsule striae, zonular stress, and the haptics' arc of contact with the capsular bag after implantation. Results: Acceptable zonular stress was observed during the successful implantation of the SING IMT. When it was implanted in the sulcus, one could reposition the haptics into the bag with two spatulas using counter-pressure in an effective strategy despite inducing tolerable, medium zonular stress. A similar technique, in reverse, allows safe explantation without damaging the rhexis or the bag, while inducing similar medium, tolerable zonular stress. In all eyes we examined, the implant considerably stretches the bag, inducing a capsular bag deformation and posterior capsule striae. Conclusion: The SING IMT can be safely implanted without significant zonular stress. In sulcus implantation and explantation, repositioning of the haptic is achievable without perturbing zonular stress using the presented approaches. It stretches average-sized capsular bags to support its weight. This is achieved by an increased arc of contact of the haptics with the capsular equator.
- 17 November 2023
- Published by Wolters Kluwer Health in Retina
- Vol. 43 (12) , 2183-2188
Open AccessCapsule Dynamics, Implantation, and Explantation of the Smaller Incision, New-Generation Implantable Miniature Telescope: a Miyake–Apple Study
Purpose: The smaller incision, new-generation implantable miniature telescope is a novel implant to optimize vision in retinal patients with central vision loss. Using Miyake–Apple techniques we visualized the device implantation, repositioning, and explantation, while noting capsular bag dynamics. Methods: Using the Miyake–Apple technique, we assessed capsular bag deformation after successful implantation of the device in human autopsy eyes. We assessed rescue strategies for converting a sulcus implantation to a capsular implantation and explantation strategies. We noted the occurrence of posterior capsule striae, zonular stress, and the haptics' arc of contact with the capsular bag after implantation. Results: Acceptable zonular stress was observed during the successful implantation of the SING IMT. When it was implanted in the sulcus, one could reposition the haptics into the bag with two spatulas using counter-pressure in an effective strategy despite inducing tolerable, medium zonular stress. A similar technique, in reverse, allows safe explantation without damaging the rhexis or the bag, while inducing similar medium, tolerable zonular stress. In all eyes we examined, the implant considerably stretches the bag, inducing a capsular bag deformation and posterior capsule striae. Conclusion: The SING IMT can be safely implanted without significant zonular stress. In sulcus implantation and explantation, repositioning of the haptic is achievable without perturbing zonular stress using the presented approaches. It stretches average-sized capsular bags to support its weight. This is achieved by an increased arc of contact of the haptics with the capsular equator.
- Open Access
Forward Light Scattering of First to Third Generation Vitreous Body Replacement Hydrogels after Surgical Application Compared to Conventional Silicone Oils and Vitreous Body
To treat certain vitreoretinal diseases, the vitreous body, a hydrogel composed of mostly collagen and hyaluronic acid, must be removed. After vitrectomy surgery, the vitreous cavity is filled with an endotamponade. Previously, pre-clinical hydrogel-based vitreous body substitutes either made from uncrosslinked monomers (1st generation), preformed crosslinked polymers (2nd generation), or in situ gelating polymers (3rd generation) have been developed. Forward light scattering is a measure of Stray light induced by optical media, when increased, causing visual disturbance and glare. During pinhole surgery, the hydrogels are injected into the vitreous cavity through a small 23G-cannula. The aim of this study was to assess if and to what extent forward light scattering is induced by vitreous body replacement hydrogels and if Stray light differs between different generations of vitreous body hydrogel replacements due to the different gelation mechanisms and fragmentation during injection. A modified C-Quant setup was used to objectively determine forward light scattering. In this study, we found that the 1st and 3rd generation vitreous body replacements show very low stray light levels even after injection (2.8 +/− 0.4 deg2/sr and 0.2 +/− 0.2 deg2/sr, respectively) as gel fragmentation and generation of interfaces is circumvented. The 2nd generation preformed hydrogels showed a permanent increase in stray light after injection that will most likely lead to symptoms such as glare when used in patients (11.9 +/− 0.9 deg2/sr). Stray light of the 2nd generation hydrogels was 3- and 2-fold increased compared to juvenile and aged vitreous bodies, respectively. In conclusion, this significant downside in the forward light scattering of the 2nd generation hydrogels should be kept in mind when developing vitreous body replacement strategies, as any source of stray light should be minimized in patients with retinal comorbidities.
Open AccessForward Light Scattering of First to Third Generation Vitreous Body Replacement Hydrogels after Surgical Application Compared to Conventional Silicone Oils and Vitreous Body
To treat certain vitreoretinal diseases, the vitreous body, a hydrogel composed of mostly collagen and hyaluronic acid, must be removed. After vitrectomy surgery, the vitreous cavity is filled with an endotamponade. Previously, pre-clinical hydrogel-based vitreous body substitutes either made from uncrosslinked monomers (1st generation), preformed crosslinked polymers (2nd generation), or in situ gelating polymers (3rd generation) have been developed. Forward light scattering is a measure of Stray light induced by optical media, when increased, causing visual disturbance and glare. During pinhole surgery, the hydrogels are injected into the vitreous cavity through a small 23G-cannula. The aim of this study was to assess if and to what extent forward light scattering is induced by vitreous body replacement hydrogels and if Stray light differs between different generations of vitreous body hydrogel replacements due to the different gelation mechanisms and fragmentation during injection. A modified C-Quant setup was used to objectively determine forward light scattering. In this study, we found that the 1st and 3rd generation vitreous body replacements show very low stray light levels even after injection (2.8 +/− 0.4 deg2/sr and 0.2 +/− 0.2 deg2/sr, respectively) as gel fragmentation and generation of interfaces is circumvented. The 2nd generation preformed hydrogels showed a permanent increase in stray light after injection that will most likely lead to symptoms such as glare when used in patients (11.9 +/− 0.9 deg2/sr). Stray light of the 2nd generation hydrogels was 3- and 2-fold increased compared to juvenile and aged vitreous bodies, respectively. In conclusion, this significant downside in the forward light scattering of the 2nd generation hydrogels should be kept in mind when developing vitreous body replacement strategies, as any source of stray light should be minimized in patients with retinal comorbidities.
- Open Access
- 1 June 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1943
Clinical Characteristics of Patients with Intraocular Lens Calcification after Pars Plana Vitrectomy
Aim: To determine the clinical risk factors that may increase the occurrence of intraocular lens (IOL) calcification in patients who had undergone pars plana vitrectomy (PPV). Methods: The medical records of 14 patients who underwent IOL explantation due to clinically significant IOL opacification after PPV were reviewed. The date of primary cataract surgery, technique and implanted IOL characteristics; the time, cause and technique of PPV; tamponade used; additional surgeries; the time of IOL calcification and explantation; and IOL explantation technique were investigated. Results: PPV had been performed as a combined procedure with cataract surgery in eight eyes and solely in six pseudophakic eyes. The IOL material was hydrophilic in six eyes, hydrophilic with a hydrophobic surface in seven eyes and undetermined in one eye. The endotamponades used during primary PPV were C2F6 in eight eyes, C3F8 in one eye, air in two eyes and silicone oil in three eyes. Two of three eyes underwent subsequent silicone oil removal and gas tamponade exchange. Gas in the anterior chamber was detected in six eyes after PPV or silicone oil removal. The mean interval between PPV and IOL opacification was 20.5 ± 18.6 months. The mean BCVA in logMAR was 0.43 ± 0.42 after PPV, which significantly decreased to 0.67 ± 0.68 before IOL explantation for IOL opacification (p = 0.007) and increased to 0.48 ± 0.59 after the IOL exchange (p = 0.015). Conclusions: PPV with endotamponades in pseudophakic eyes, particularly gas, seems to increase the risk for secondary IOL calcification, especially in hydrophilic IOLs. IOL exchange seems to solve this problem when clinically significant vision loss occurs.
- 1 June 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1943
Open AccessClinical Characteristics of Patients with Intraocular Lens Calcification after Pars Plana Vitrectomy
Aim: To determine the clinical risk factors that may increase the occurrence of intraocular lens (IOL) calcification in patients who had undergone pars plana vitrectomy (PPV). Methods: The medical records of 14 patients who underwent IOL explantation due to clinically significant IOL opacification after PPV were reviewed. The date of primary cataract surgery, technique and implanted IOL characteristics; the time, cause and technique of PPV; tamponade used; additional surgeries; the time of IOL calcification and explantation; and IOL explantation technique were investigated. Results: PPV had been performed as a combined procedure with cataract surgery in eight eyes and solely in six pseudophakic eyes. The IOL material was hydrophilic in six eyes, hydrophilic with a hydrophobic surface in seven eyes and undetermined in one eye. The endotamponades used during primary PPV were C2F6 in eight eyes, C3F8 in one eye, air in two eyes and silicone oil in three eyes. Two of three eyes underwent subsequent silicone oil removal and gas tamponade exchange. Gas in the anterior chamber was detected in six eyes after PPV or silicone oil removal. The mean interval between PPV and IOL opacification was 20.5 ± 18.6 months. The mean BCVA in logMAR was 0.43 ± 0.42 after PPV, which significantly decreased to 0.67 ± 0.68 before IOL explantation for IOL opacification (p = 0.007) and increased to 0.48 ± 0.59 after the IOL exchange (p = 0.015). Conclusions: PPV with endotamponades in pseudophakic eyes, particularly gas, seems to increase the risk for secondary IOL calcification, especially in hydrophilic IOLs. IOL exchange seems to solve this problem when clinically significant vision loss occurs.
- Open Access
- 28 June 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (7) , 1364
Intravitreal Application: Physicochemical Properties of Drugs Dissolved in Silicone Oils of Different Density in Comparison to the Porcine Vitreous Body
Silicone oil endotamponades provide a reservoir for drugs in the eye. Following vitrectomy surgery to treat retinal detachments, extensive diabetic retinopathy or endophthalmitis, they can be used as long-term lipophilic depots. This study aimed to investigate the physicochemical properties of intravitreally applied drugs of different lipophilicity, namely vancomycin, ceftazidime and voriconazole. For this purpose, an in vitro model of the silicone-oil-filled eye compared to porcine vitreous bodies (PVBs) was used. In a glass container, either light or heavy silicone oil or PVB was set into equilibrium with an aqueous fluid. Vancomycin, voriconazole and ceftazidime were added in concentrations commonly applied in clinical practice. The time course of the concentration of the drugs was determined in the hydrophilic phase for up to 24 h. With silicone oil present, the concentrations of vancomycin, voriconazole and ceftazidime were elevated in the aqueous humor when compared to the vitreous body (p < 0.001 for all drugs). With increasing lipophilicity, higher concentrations of the drug dissolved in silicone oil after 24 h (52.7%, 49.1% and 34.3% for vancomycin, ceftazidime and voriconazole, respectively). While no difference between lighter- and heavier-than-water silicone oil was apparent for vancomycin and ceftazidime (p = 0.17 and p = 0.72), voriconazole dissolved significantly better in the heavier-than-water silicone oil (p = 0.002). A higher-than-expected percentage of the glycopeptide vancomycin dissolved in the porcine vitreous body, possibly due to protein binding. In conclusion, silicone oils influence the drug concentration and distribution of intravitreally applied drugs depending on their lipophilicity. The addition of F6H8 used to create heavy silicone oils attenuates these effects for lipophilic drugs. Knowledge of the distribution of these intravitreally applied drugs is crucial to ensure the desired anti-infectious effect.
- 28 June 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (7) , 1364
Open AccessIntravitreal Application: Physicochemical Properties of Drugs Dissolved in Silicone Oils of Different Density in Comparison to the Porcine Vitreous Body
Silicone oil endotamponades provide a reservoir for drugs in the eye. Following vitrectomy surgery to treat retinal detachments, extensive diabetic retinopathy or endophthalmitis, they can be used as long-term lipophilic depots. This study aimed to investigate the physicochemical properties of intravitreally applied drugs of different lipophilicity, namely vancomycin, ceftazidime and voriconazole. For this purpose, an in vitro model of the silicone-oil-filled eye compared to porcine vitreous bodies (PVBs) was used. In a glass container, either light or heavy silicone oil or PVB was set into equilibrium with an aqueous fluid. Vancomycin, voriconazole and ceftazidime were added in concentrations commonly applied in clinical practice. The time course of the concentration of the drugs was determined in the hydrophilic phase for up to 24 h. With silicone oil present, the concentrations of vancomycin, voriconazole and ceftazidime were elevated in the aqueous humor when compared to the vitreous body (p < 0.001 for all drugs). With increasing lipophilicity, higher concentrations of the drug dissolved in silicone oil after 24 h (52.7%, 49.1% and 34.3% for vancomycin, ceftazidime and voriconazole, respectively). While no difference between lighter- and heavier-than-water silicone oil was apparent for vancomycin and ceftazidime (p = 0.17 and p = 0.72), voriconazole dissolved significantly better in the heavier-than-water silicone oil (p = 0.002). A higher-than-expected percentage of the glycopeptide vancomycin dissolved in the porcine vitreous body, possibly due to protein binding. In conclusion, silicone oils influence the drug concentration and distribution of intravitreally applied drugs depending on their lipophilicity. The addition of F6H8 used to create heavy silicone oils attenuates these effects for lipophilic drugs. Knowledge of the distribution of these intravitreally applied drugs is crucial to ensure the desired anti-infectious effect.
- Open Access
- 28 June 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (2) , 230-237
Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study
Purpose: To compare 1 new intraocular lens injector system against 3 standard injector systems in porcine eyes. Setting: David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany. Design: In vitro laboratory study. Methods: In 70 porcine eyes, +20.0 diopter IOLs were implanted with the following systems: multiSert, UltraSert, iTec and RayOne, i.e., S1.8 (incision size: 1.8mm), S2.0 (2.0mm), S2.2P (2.2mm, push-mode), S2.2S (2.2mm, screw-mode), U2.2 (2.2mm), iT2.2 (2.2mm) and R2.0 (2.0mm). Corneal incision sizes were measured before and after implantation with a incision gauge set. Ease of use was evaluated using a Likert scale. IOL delivery time and performance were determined based on Miyake-Apple view videos. Results: The incision enlargements were 0.36 ± 0.08mm (S1.8), 0.15 ± 0.07mm (S2.0), 0.17 ± 0.12mm (S2.2P), 0.28 ± 0.10mm (S2.2S), 0.32 ± 0.09mm (U2.2), 0.30 ± 0.08mm (iT2.2) and 0.35 ± 0.11mm (R2.0). Total scores of ease of use were 23.00 (S1.8), 25.00 (S2.0), 29.00 (S2.2P), 26.00 (S2.2S), 26.00 (U2.2), 25.00 (iT2.2) and 24.00 (R2.0). As for the mean delivery time, iT2.2 took the longest time (13.20 ± 3.29 seconds), while S2.2S took the shortest time (4.50 ± 0.71 seconds). Haptic-optic adhesion was observed in S1.8 (4, 40%), S2.2P (2, 20%), U2.2 (5, 50%) and iT2.2 (5, 50%). Conclusions: Injector S, with the appropriate incision size and implantation method, could achieve better results regarding incision enlargement, ease of use, delivery time and performance than other injector systems. There was an indirect relationship between incision size and inadvertent events.
- 28 June 2021
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (2) , 230-237
Open AccessComparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study
Purpose: To compare 1 new intraocular lens injector system against 3 standard injector systems in porcine eyes. Setting: David J Apple Center for Vision Research, Department of Ophthalmology, University Hospital Heidelberg, Heidelberg, Germany. Design: In vitro laboratory study. Methods: In 70 porcine eyes, +20.0 diopter IOLs were implanted with the following systems: multiSert, UltraSert, iTec and RayOne, i.e., S1.8 (incision size: 1.8mm), S2.0 (2.0mm), S2.2P (2.2mm, push-mode), S2.2S (2.2mm, screw-mode), U2.2 (2.2mm), iT2.2 (2.2mm) and R2.0 (2.0mm). Corneal incision sizes were measured before and after implantation with a incision gauge set. Ease of use was evaluated using a Likert scale. IOL delivery time and performance were determined based on Miyake-Apple view videos. Results: The incision enlargements were 0.36 ± 0.08mm (S1.8), 0.15 ± 0.07mm (S2.0), 0.17 ± 0.12mm (S2.2P), 0.28 ± 0.10mm (S2.2S), 0.32 ± 0.09mm (U2.2), 0.30 ± 0.08mm (iT2.2) and 0.35 ± 0.11mm (R2.0). Total scores of ease of use were 23.00 (S1.8), 25.00 (S2.0), 29.00 (S2.2P), 26.00 (S2.2S), 26.00 (U2.2), 25.00 (iT2.2) and 24.00 (R2.0). As for the mean delivery time, iT2.2 took the longest time (13.20 ± 3.29 seconds), while S2.2S took the shortest time (4.50 ± 0.71 seconds). Haptic-optic adhesion was observed in S1.8 (4, 40%), S2.2P (2, 20%), U2.2 (5, 50%) and iT2.2 (5, 50%). Conclusions: Injector S, with the appropriate incision size and implantation method, could achieve better results regarding incision enlargement, ease of use, delivery time and performance than other injector systems. There was an indirect relationship between incision size and inadvertent events.
- Open Access
- 5 February 2021
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 10 (1) , 165-174
Quantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
Introduction Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material from its introduction to the present day. Methods In a laboratory setup, an in vitro model was used to induce glistenings in hydrophobic acrylic IOLs manufactured by one company (Alcon, Fort Worth, TX, USA) in different years: 23 1990s-manufacture hydrophobic acrylic three-piece IOLs (MA30BA/MA60AC) that were explanted in 1996 and 1997, and five of each of the newer AcrySof IOL models (MA60AC, SA60AT, TFNT00 and SN60WF) from 2014 to 2017. Furthermore, five Clareon (SY60WF) IOLs were put through the same accelerated aging procedure. The number of microvacuoles per square millimeter (MV/mm2) was determined in the central part of each IOL optic and compared between the groups. Results The mean number of MV was highest in the 1990s-manufacture Alcon acrylic IOLs, with 1289 (± 738) MV/mm2. The number decreased to 650 (± 101), 192 (± 105), 175 (± 112) and 47 (± 26) for MA60AC, SA60AT, TFNT00 and SN60WF, respectively. The lowest count was obtained in the Clareon group, with 1 (± 1) MV/mm2. Conclusions A high number of glistenings was induced in the explanted IOLs from the 1990s. The propensity for glistening formation decreased considerably after that decade and now in current use. Even though in vitro glistening formation in today’s AcrySof material was low, the Clareon material was essentially glistenings-free.
- 5 February 2021
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 10 (1) , 165-174
Open AccessQuantification of the In Vitro Predisposition to Glistening Formation in One Manufacturer’s Acrylic Intraocular Lenses Made in Different Decades
Introduction Foldable hydrophobic acrylic intraocular lenses (IOLs) are prone to develop a long-term postoperative material change called glistenings. The aim of this study was to investigate the changes in the predisposition for glistening formation in one type of hydrophobic acrylic IOL material from its introduction to the present day. Methods In a laboratory setup, an in vitro model was used to induce glistenings in hydrophobic acrylic IOLs manufactured by one company (Alcon, Fort Worth, TX, USA) in different years: 23 1990s-manufacture hydrophobic acrylic three-piece IOLs (MA30BA/MA60AC) that were explanted in 1996 and 1997, and five of each of the newer AcrySof IOL models (MA60AC, SA60AT, TFNT00 and SN60WF) from 2014 to 2017. Furthermore, five Clareon (SY60WF) IOLs were put through the same accelerated aging procedure. The number of microvacuoles per square millimeter (MV/mm2) was determined in the central part of each IOL optic and compared between the groups. Results The mean number of MV was highest in the 1990s-manufacture Alcon acrylic IOLs, with 1289 (± 738) MV/mm2. The number decreased to 650 (± 101), 192 (± 105), 175 (± 112) and 47 (± 26) for MA60AC, SA60AT, TFNT00 and SN60WF, respectively. The lowest count was obtained in the Clareon group, with 1 (± 1) MV/mm2. Conclusions A high number of glistenings was induced in the explanted IOLs from the 1990s. The propensity for glistening formation decreased considerably after that decade and now in current use. Even though in vitro glistening formation in today’s AcrySof material was low, the Clareon material was essentially glistenings-free.
- Open Access
- 1 September 2020
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 19, 100797
Variation in intraocular lens calcification under different environmental conditions in eyes with supplementary sulcus-supported lenses
- 1 September 2020
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 19, 100797
Open AccessVariation in intraocular lens calcification under different environmental conditions in eyes with supplementary sulcus-supported lenses