Shiv Patel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shiv Patel has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jesse Vincent Jokerst
University of California, San Diego
3 shared publications - Wonjun Yim
Materials Science and Engineering Program University of California San Diego, La Jolla, California, USA
3 shared publications - Andrew M. Vahabzadeh-Hagh
University of California San Diego
2 shared publications - Anupam K. Garg
Wilmer Eye Institute, Johns Hopkins Hospital, Baltimore, Maryland
2 shared publications - Sahil H. Shah
Byers Eye Institute and Spencer Center for Vision Research, Stanford University
2 shared publications Anupam K. Garg
School of Medicine, University of California, San Diego, La Jolla, California, USA
1 shared publication
Latest Publications
- Open Access
- 21 February 2022
- Published by F1000 Research Ltd in MedEdPublish
- Vol. 12
A low-cost otoscopy simulator increased confidence in mechanical otoscopy skills and tympanic membrane pathology identification among preclinical medical students during the COVID-19 pandemic
Background: Diagnostic evaluation of otologic diseases often requires otoscopy to visualize the tympanic membrane. The fundamentals of otoscopy include both learning the mechanics of using an otoscope and accurately identifying ear pathologies. During the COVID-19 pandemic, there was limited peer-to-peer physical exam practice for preclinical medical students. We developed a low-cost 3D-printed otoscopy simulator to teach the otoscopic exam to small groups of medical students. Methods: A modified open-source 3-dimensional (3D) head was printed, and a silicone ear was attached. A user interface was created to display one normal tympanic membrane and four pathologies. Preclinical medical students attended a didactic lecture on common otologic pathologies and on how to perform otoscopy. Students then practiced otoscopy and pathology identification on the simulator in small groups. After the session, students were provided an optional survey to evaluate their confidence in otoscopy skills and pathology identification. Results: A total of 47 out of 134 (35%) medical students completed the survey, of whom 60% reported that training with the 3D printed otoscopy simulator was at least moderately effective in learning the mechanical techniques of otoscopy, and 66% found the simulator to be at least moderately effective in helping them learn to identify pathology. The majority (57%) of students reported that the otoscopy simulator was more effective than practicing otoscopy on their peers. Conclusions: We demonstrate the utility of a novel low-cost 3D printed otoscopy simulator to teach both the mechanical skills and pathology identification necessary in performing an otoscopic exam to preclinical medical students.
- 21 February 2022
- Published by F1000 Research Ltd in MedEdPublish
- Vol. 12
Open AccessA low-cost otoscopy simulator increased confidence in mechanical otoscopy skills and tympanic membrane pathology identification among preclinical medical students during the COVID-19 pandemic
Background: Diagnostic evaluation of otologic diseases often requires otoscopy to visualize the tympanic membrane. The fundamentals of otoscopy include both learning the mechanics of using an otoscope and accurately identifying ear pathologies. During the COVID-19 pandemic, there was limited peer-to-peer physical exam practice for preclinical medical students. We developed a low-cost 3D-printed otoscopy simulator to teach the otoscopic exam to small groups of medical students. Methods: A modified open-source 3-dimensional (3D) head was printed, and a silicone ear was attached. A user interface was created to display one normal tympanic membrane and four pathologies. Preclinical medical students attended a didactic lecture on common otologic pathologies and on how to perform otoscopy. Students then practiced otoscopy and pathology identification on the simulator in small groups. After the session, students were provided an optional survey to evaluate their confidence in otoscopy skills and pathology identification. Results: A total of 47 out of 134 (35%) medical students completed the survey, of whom 60% reported that training with the 3D printed otoscopy simulator was at least moderately effective in learning the mechanical techniques of otoscopy, and 66% found the simulator to be at least moderately effective in helping them learn to identify pathology. The majority (57%) of students reported that the otoscopy simulator was more effective than practicing otoscopy on their peers. Conclusions: We demonstrate the utility of a novel low-cost 3D printed otoscopy simulator to teach both the mechanical skills and pathology identification necessary in performing an otoscopic exam to preclinical medical students.
- Open Access
- 27 December 2021
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 103 (8) , 481-483
Breathy Dysphonia, Not Just a Pain in the Neck
We describe a rare occurrence of unilateral vocal fold paralysis associated with a cervical osteophyte abutting the course of the recurrent laryngeal nerve. Trans-nasal laryngoscopy is vital in diagnosing vocal fold paralysis, but often does not provide insight into etiology. This case highlights the importance of radiographic imaging in newly diagnosed vocal fold paralysis, and underscores the principle that a diagnosis is not idiopathic until all sources have been ruled out.
- 27 December 2021
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 103 (8) , 481-483
Open AccessBreathy Dysphonia, Not Just a Pain in the Neck
We describe a rare occurrence of unilateral vocal fold paralysis associated with a cervical osteophyte abutting the course of the recurrent laryngeal nerve. Trans-nasal laryngoscopy is vital in diagnosing vocal fold paralysis, but often does not provide insight into etiology. This case highlights the importance of radiographic imaging in newly diagnosed vocal fold paralysis, and underscores the principle that a diagnosis is not idiopathic until all sources have been ruled out.
- Open Access
- 9 December 2021
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 7 (1) , 190-196
Patient‐worn endoscopy mask to protect against viral transmission
Objectives To design and evaluate patient-worn personal protective equipment (PPE) that allows providers to perform endoscopy while protecting against droplet and airborne disease transmission. Study design Single subject study. Methods Mask efficacy was evaluated using a cough simulator that sprays dye visible under ultra-violet light. User-testing was performed on an airway trainer mannequin where each subject performed the endoscopy with and without the mask in random orders. Their time to completion and number of attempts before successful completion were recorded, and each subject was asked to fill out a NASA Task Load Index (TLX) form with respect to their experience. Results The mask has a filtration efficiency of 97.31% and eliminated any expelled particles with the cough simulator. Without the mask, a simulated cough is visualized as it progresses away from the cough origin. Subjects who performed trans-nasal endoscopy spent 27.8 ± 8.0 s to visualize the vocal cords for the no mask condition and 28.7 ± 13.6 s for the mask condition (mean ± SD, p > .05). There was no statistically significant difference found in the mental demand, physical demand, temporal demand, performance, effort, and frustration of endoscopy under the no mask and mask conditions (all p > .05). Conclusion The designed PPE provides an effective barrier for viral droplet and airborne transmission while allowing the ability to perform endoscopy with ease. Level of Evidence 3 Laryngoscope, 2021.
- 9 December 2021
- Published by Wiley in Laryngoscope Investigative Otolaryngology
- Vol. 7 (1) , 190-196
Open AccessPatient‐worn endoscopy mask to protect against viral transmission
Objectives To design and evaluate patient-worn personal protective equipment (PPE) that allows providers to perform endoscopy while protecting against droplet and airborne disease transmission. Study design Single subject study. Methods Mask efficacy was evaluated using a cough simulator that sprays dye visible under ultra-violet light. User-testing was performed on an airway trainer mannequin where each subject performed the endoscopy with and without the mask in random orders. Their time to completion and number of attempts before successful completion were recorded, and each subject was asked to fill out a NASA Task Load Index (TLX) form with respect to their experience. Results The mask has a filtration efficiency of 97.31% and eliminated any expelled particles with the cough simulator. Without the mask, a simulated cough is visualized as it progresses away from the cough origin. Subjects who performed trans-nasal endoscopy spent 27.8 ± 8.0 s to visualize the vocal cords for the no mask condition and 28.7 ± 13.6 s for the mask condition (mean ± SD, p > .05). There was no statistically significant difference found in the mental demand, physical demand, temporal demand, performance, effort, and frustration of endoscopy under the no mask and mask conditions (all p > .05). Conclusion The designed PPE provides an effective barrier for viral droplet and airborne transmission while allowing the ability to perform endoscopy with ease. Level of Evidence 3 Laryngoscope, 2021.
- 1 February 2021
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 222, 76-81
Assessment of Respiratory Droplet Transmission During the Ophthalmic Slit-Lamp Exam: A Particle Tracking Analysis
- 1 February 2021
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 222, 76-81
Assessment of Respiratory Droplet Transmission During the Ophthalmic Slit-Lamp Exam: A Particle Tracking Analysis
- Open Access
- 17 September 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (9) , 3002
Assessing the Physiological Relevance of Cough Simulators for Respiratory Droplet Dispersion
Various breathing and cough simulators have been used to model respiratory droplet dispersion and viral droplets, in particular for SARS-CoV-2 modeling. However, limited data are available comparing these cough simulations to physiological breathing and coughing. In this study, three different cough simulators (Teleflex Mucosal Atomization Device Nasal (MAD Nasal), a spray gun, and GloGermTM MIST) that have been used in the literature were studied to assess their physiologic relevance. Droplet size, velocity, dispersion, and force generated by the simulators were measured. Droplet size was measured with scanning electron microscopy (SEM). Slow-motion videography was used to 3D reconstruct and measure the velocity of each simulated cough. A force-sensitive resistor was used to measure the force of each simulated cough. The average size of droplets from each cough simulator was 176 to 220 µm. MAD Nasal, the spray gun, and GloGermTM MIST traveled 0.38 m, 0.89 m, and 1.62 m respectively. The average velocities for the MAD Nasal, spray gun, and GloGermTM MIST were 1.57 m/s, 2.60 m/s, and 9.27 m/s respectively, and all yielded a force of TM MIST and the spray gun most closely resemble physiological coughs and breathing respectively. In conclusion, none of the simulators tested accurately modeled all physiologic characteristics (droplet size, 3-D dispersion velocity, and force) of a cough, while there were various strengths and weaknesses of each method. One should take this into account when performing simulations with these devices.
- 17 September 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (9) , 3002
Open AccessAssessing the Physiological Relevance of Cough Simulators for Respiratory Droplet Dispersion
Various breathing and cough simulators have been used to model respiratory droplet dispersion and viral droplets, in particular for SARS-CoV-2 modeling. However, limited data are available comparing these cough simulations to physiological breathing and coughing. In this study, three different cough simulators (Teleflex Mucosal Atomization Device Nasal (MAD Nasal), a spray gun, and GloGermTM MIST) that have been used in the literature were studied to assess their physiologic relevance. Droplet size, velocity, dispersion, and force generated by the simulators were measured. Droplet size was measured with scanning electron microscopy (SEM). Slow-motion videography was used to 3D reconstruct and measure the velocity of each simulated cough. A force-sensitive resistor was used to measure the force of each simulated cough. The average size of droplets from each cough simulator was 176 to 220 µm. MAD Nasal, the spray gun, and GloGermTM MIST traveled 0.38 m, 0.89 m, and 1.62 m respectively. The average velocities for the MAD Nasal, spray gun, and GloGermTM MIST were 1.57 m/s, 2.60 m/s, and 9.27 m/s respectively, and all yielded a force of TM MIST and the spray gun most closely resemble physiological coughs and breathing respectively. In conclusion, none of the simulators tested accurately modeled all physiologic characteristics (droplet size, 3-D dispersion velocity, and force) of a cough, while there were various strengths and weaknesses of each method. One should take this into account when performing simulations with these devices.
- Open Access
Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density
Personal protective equipment (PPE) including N95 respirators are critical for persons exposed to SARS-CoV-2. KN95 respirators and N95 decontamination protocols have been described as solutions to a lack of such PPE. However, there are a few materials science studies that characterize the charge distribution and physical changes accompanying disinfection treatments particularly heating. Here, we report the filtration efficiency, dipole charge density, and fiber integrity of pristine N95 and KN95 respirators before and after various decontamination methods. We found that the filter layer of N95 is 8-fold thicker than that of KN95, which explains its 10% higher filtration efficiency (97.03 %) versus KN95 (87.76 %) under pristines condition. After 60 minutes of 70 °C treatment, the filtration efficiency and dipole charge density of N95 became 97.16% and 12.48 μC/m 2 , while those of KN95 were 83.64% and 1.48 μC/m 2 ; moreover, fit factor of N95 was 55 and that of KN95 was 2.7. In conclusion, the KN95 respirator is an inferior alternative of N95 respirator. In both systems, a loss of electrostatic charge does not directly correlate to a decrease in performance.
Open AccessAssessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density
Personal protective equipment (PPE) including N95 respirators are critical for persons exposed to SARS-CoV-2. KN95 respirators and N95 decontamination protocols have been described as solutions to a lack of such PPE. However, there are a few materials science studies that characterize the charge distribution and physical changes accompanying disinfection treatments particularly heating. Here, we report the filtration efficiency, dipole charge density, and fiber integrity of pristine N95 and KN95 respirators before and after various decontamination methods. We found that the filter layer of N95 is 8-fold thicker than that of KN95, which explains its 10% higher filtration efficiency (97.03 %) versus KN95 (87.76 %) under pristines condition. After 60 minutes of 70 °C treatment, the filtration efficiency and dipole charge density of N95 became 97.16% and 12.48 μC/m 2 , while those of KN95 were 83.64% and 1.48 μC/m 2 ; moreover, fit factor of N95 was 55 and that of KN95 was 2.7. In conclusion, the KN95 respirator is an inferior alternative of N95 respirator. In both systems, a loss of electrostatic charge does not directly correlate to a decrease in performance.
- Open Access
Assessment of respiratory droplet transmission during the ophthalmic slit lamp exam: a particle tracking analysis
Importance: The global COVID-19 pandemic, which began in late 2019, has resulted in a renewed focus on the importance of personal protective equipment (PPE) and other interventions to decrease the spread of infectious diseases. While several ophthalmology organizations have recently released guidance on appropriate PPE for surgical procedures and ophthalmology clinics, there is limited experimental evidence demonstrating the efficacy of the various interventions that have been suggested. In this study, we evaluate high-risk aspects of the slit-lamp exam and the effect of various PPE interventions. Objective: To determine the effectiveness of surgical masks, slit lamp shields, and gloves in decreasing the spread of large droplets in an ophthalmology clinical setting and evaluating high-risk sources of contamination. Design: Experimental cough simulation using a fluorescent surrogate of respiratory droplets during an ophthalmic slit lamp examination. Setting: Single-center Participants: Patient Simulation Main outcomes and measure(s): Presence of fluorescent particles in the air near or on slit lamp and simulated slit lamp examiner. Results: Simulated coughing without a mask or slit lamp shield resulted in widespread dispersion of fluorescent droplets on the model slit lamp examination. Coughing with a mask resulted in the most significant decrease in fluorescent droplets, however, particles were still seen to escape from the top of the mask. Coughing with the slit lamp shield alone blocked the majority of forward particle dispersion; however significant distributions of respiratory droplets were found on the slit lamp joystick as well as table. Coughing with both mask and slit lamp shield resulted in the least dispersion on to the simulated examiner. Scanning electron microscopy demonstrated particle sizes of 3-100μm. Conclusion and relevance: Masking has the greatest effect in limiting spread of respiratory droplets, while slit lamp shields, and gloves also contribute to limiting exposure to respiratory droplets from SARS-CoV-2 during slit lamp examination. Key Points: Question: How effective are certain personal protective equipment and interventions in the clinic in preventing respiratory droplet spread? Findings: Simulating patient coughing during the slit lamp exam demonstrated that masking appeared to be the most effective intervention to prevent spread of respiratory droplets. Slit lamp shields and gloves were also effective in decreasing exposure to respiratory droplets. Meaning: This study confirms the importance of masking, slit lamp shields, as well as gloves as important interventions to limit exposure to respiratory droplets from respiratory viruses such as SARS-CoV-2.
Open AccessAssessment of respiratory droplet transmission during the ophthalmic slit lamp exam: a particle tracking analysis
Importance: The global COVID-19 pandemic, which began in late 2019, has resulted in a renewed focus on the importance of personal protective equipment (PPE) and other interventions to decrease the spread of infectious diseases. While several ophthalmology organizations have recently released guidance on appropriate PPE for surgical procedures and ophthalmology clinics, there is limited experimental evidence demonstrating the efficacy of the various interventions that have been suggested. In this study, we evaluate high-risk aspects of the slit-lamp exam and the effect of various PPE interventions. Objective: To determine the effectiveness of surgical masks, slit lamp shields, and gloves in decreasing the spread of large droplets in an ophthalmology clinical setting and evaluating high-risk sources of contamination. Design: Experimental cough simulation using a fluorescent surrogate of respiratory droplets during an ophthalmic slit lamp examination. Setting: Single-center Participants: Patient Simulation Main outcomes and measure(s): Presence of fluorescent particles in the air near or on slit lamp and simulated slit lamp examiner. Results: Simulated coughing without a mask or slit lamp shield resulted in widespread dispersion of fluorescent droplets on the model slit lamp examination. Coughing with a mask resulted in the most significant decrease in fluorescent droplets, however, particles were still seen to escape from the top of the mask. Coughing with the slit lamp shield alone blocked the majority of forward particle dispersion; however significant distributions of respiratory droplets were found on the slit lamp joystick as well as table. Coughing with both mask and slit lamp shield resulted in the least dispersion on to the simulated examiner. Scanning electron microscopy demonstrated particle sizes of 3-100μm. Conclusion and relevance: Masking has the greatest effect in limiting spread of respiratory droplets, while slit lamp shields, and gloves also contribute to limiting exposure to respiratory droplets from SARS-CoV-2 during slit lamp examination. Key Points: Question: How effective are certain personal protective equipment and interventions in the clinic in preventing respiratory droplet spread? Findings: Simulating patient coughing during the slit lamp exam demonstrated that masking appeared to be the most effective intervention to prevent spread of respiratory droplets. Slit lamp shields and gloves were also effective in decreasing exposure to respiratory droplets. Meaning: This study confirms the importance of masking, slit lamp shields, as well as gloves as important interventions to limit exposure to respiratory droplets from respiratory viruses such as SARS-CoV-2.