Takayuki Oku
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takayuki Oku has a total of 231 co-authors. Here are the top co-authors by number of shared publications:
- Takashi Ino
High Energy Accelerator Research Organization Institute of Materials Structure Science 1-1 Oho, Tsukuba, Ibaraki 305-0801
9 shared publications - Takuya Okudaira
J-PARC Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195, Japan
9 shared publications - Hirohiko M. Shimizu
Nagoya University
8 shared publications - Kenichi Oikawa
J-PARC Center, Japan Atomic Energy Agency, Tokai, Ibaraki 319-1195, Japan
7 shared publications - Shingo Takahashi
Institute for Solid State Physics, University of Tokyo
7 shared publications - Masaaki Kitaguchi
Nagoya University Department of Physics Furocho, Chikusa, Nagoya 464-8602
6 shared publications
Latest Publications
- 15 June 2026
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 95 (6)
Verification of Atomic-Scale Magnetic Imaging Using Polarized Neutrons
- 15 June 2026
- Published by Physical Society of Japan in Journal of the Physical Society of Japan
- Vol. 95 (6)
Verification of Atomic-Scale Magnetic Imaging Using Polarized Neutrons
- Open Access
- 19 May 2026
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (6)
First Constraint on the P-odd/T-odd Cross Section in Polarized Neutron Transmission through Transversely Polarized 139La
We report the first constraint on time-reversal invariance violating (TRIV) effects in polarized neutron transmission through a transversely polarized $^{139}$La target. We formulate the transmission asymmetry within the density matrix formalism, explicitly incorporating the forward scattering amplitude of $^{139}$La including tensor polarization terms up to the third rank. The formalism is applied to existing transmission data originally obtained to measure the spin-dependent cross section near the 0.75 eV p-wave resonance. Since these data were not optimized for P-odd/T-odd observables, the attainable sensitivity is intrinsically limited; nevertheless, they provide a useful test of the formalism on real experimental data. No statistically significant TRIV signal is observed. By analyzing the global $\chi ^2$ structure in the parameter space, we obtain an upper limit of $|W_T|\lt 15~\mathrm{eV}$ at the 90% confidence level. This corresponds to an upper limit on the resonance-averaged TRIV cross section of $|\Delta \sigma _{\not{T}\not{P}}|\lt 8.3\times 10^2~\mathrm{b}$. These results validate the present theoretical framework and provide guidance for future dedicated TRIV searches in polarized neutron transmission experiments.- 19 May 2026
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2026 (6)
Open AccessFirst Constraint on the P-odd/T-odd Cross Section in Polarized Neutron Transmission through Transversely Polarized 139La
We report the first constraint on time-reversal invariance violating (TRIV) effects in polarized neutron transmission through a transversely polarized $^{139}$La target. We formulate the transmission asymmetry within the density matrix formalism, explicitly incorporating the forward scattering amplitude of $^{139}$La including tensor polarization terms up to the third rank. The formalism is applied to existing transmission data originally obtained to measure the spin-dependent cross section near the 0.75 eV p-wave resonance. Since these data were not optimized for P-odd/T-odd observables, the attainable sensitivity is intrinsically limited; nevertheless, they provide a useful test of the formalism on real experimental data. No statistically significant TRIV signal is observed. By analyzing the global $\chi ^2$ structure in the parameter space, we obtain an upper limit of $|W_T|\lt 15~\mathrm{eV}$ at the 90% confidence level. This corresponds to an upper limit on the resonance-averaged TRIV cross section of $|\Delta \sigma _{\not{T}\not{P}}|\lt 8.3\times 10^2~\mathrm{b}$. These results validate the present theoretical framework and provide guidance for future dedicated TRIV searches in polarized neutron transmission experiments. - Open Access
- 1 February 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (1) , 69-79
Magnetic-lens-generated polarized neutron beam with enhanced intensity and Q resolution for small-angle neutron scattering
We installed a 30 mm-bore 3.2 m-long magnetic lens in the small-angle neutron scattering diffractometer (SANS-J) at the Japan Research Reactor 3 to focus the neutron beam near the sample position for measurements at Q > 0.1 nm −1 . The focused beam at the sample position was over three times more intense than the standard non-focused beam, while the Q resolution was improved. The positive spin component of the neutron beam was focused near the sample, whereas the negative spin component was defocused and blocked by the slit just in front of the sample, producing a polarized beam. The 8 mm-diameter focusing polarized beam achieved a polarization of 0.95–0.96 and an intensity up to 22 times greater than that of a non-focusing polarized beam with the same collimation length. Using this beam with a remanent supermirror-coated spin analyser, we demonstrate that polarization analysis measurements of hydrogen-containing samples can be completed within tens of minutes.
- 1 February 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (1) , 69-79
Open AccessMagnetic-lens-generated polarized neutron beam with enhanced intensity and Q resolution for small-angle neutron scattering
We installed a 30 mm-bore 3.2 m-long magnetic lens in the small-angle neutron scattering diffractometer (SANS-J) at the Japan Research Reactor 3 to focus the neutron beam near the sample position for measurements at Q > 0.1 nm −1 . The focused beam at the sample position was over three times more intense than the standard non-focused beam, while the Q resolution was improved. The positive spin component of the neutron beam was focused near the sample, whereas the negative spin component was defocused and blocked by the slit just in front of the sample, producing a polarized beam. The 8 mm-diameter focusing polarized beam achieved a polarization of 0.95–0.96 and an intensity up to 22 times greater than that of a non-focusing polarized beam with the same collimation length. Using this beam with a remanent supermirror-coated spin analyser, we demonstrate that polarization analysis measurements of hydrogen-containing samples can be completed within tens of minutes.
- Open Access
- 16 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 981
Development of the Direct Deuteration Method for Amino Acids and Characterization of Deuterated Tryptophan
Proteins and peptides are vital biomolecules, and deuterated amino acids are increasingly applied in areas such as drug discovery, metabolic tracing, and neutron scattering studies. In this study, we performed deuteration on all 20 proteinogenic amino acids, including their side chains, and established efficient methods for 13 amino acids. Using a Pt/C-catalyzed hydrogen–deuterium exchange reaction, the reaction parameters were optimized to achieve the selective and stable incorporation of deuterium. In addition, the resulting deuterated compounds, focusing on tryptophan, were characterized in order to assess their physicochemical properties. Because the deuteration reaction caused significant racemization of amino acids, deuterated D/L-tryptophan was isolated using a chiral separation method. Deuterated tryptophan characterization studies confirmed that the photostability was markedly enhanced by deuteration, whereas the acid stability showed no clear isotopic effect. The X-ray crystal structure analyses revealed minimal changes upon the hydrogen-to-deuterium substitution. These results provide a robust platform for the supply of deuterated amino acids, facilitating their application in drug development, structural analysis, and creation of advanced functional biomaterials.
- 16 September 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (9) , 981
Open AccessDevelopment of the Direct Deuteration Method for Amino Acids and Characterization of Deuterated Tryptophan
Proteins and peptides are vital biomolecules, and deuterated amino acids are increasingly applied in areas such as drug discovery, metabolic tracing, and neutron scattering studies. In this study, we performed deuteration on all 20 proteinogenic amino acids, including their side chains, and established efficient methods for 13 amino acids. Using a Pt/C-catalyzed hydrogen–deuterium exchange reaction, the reaction parameters were optimized to achieve the selective and stable incorporation of deuterium. In addition, the resulting deuterated compounds, focusing on tryptophan, were characterized in order to assess their physicochemical properties. Because the deuteration reaction caused significant racemization of amino acids, deuterated D/L-tryptophan was isolated using a chiral separation method. Deuterated tryptophan characterization studies confirmed that the photostability was markedly enhanced by deuteration, whereas the acid stability showed no clear isotopic effect. The X-ray crystal structure analyses revealed minimal changes upon the hydrogen-to-deuterium substitution. These results provide a robust platform for the supply of deuterated amino acids, facilitating their application in drug development, structural analysis, and creation of advanced functional biomaterials.
- Open Access
- 25 July 2025
- Published by MDPI AG in Preprints.org
Development of the Direct Deuteration Method for Amino Acids and Characterization of Deuterated Tryptophan
Proteins and peptides are essential biomolecules involved in the maintenance of biological functions and disease development. Their structural and functional analyses are crucial for drug discovery and pathology. Amino acids, the fundamental building blocks of these biomolecules, are increasingly utilized in deuterated forms in diverse fields, such as metabolic tracing and neutron scattering studies. In this study, we have developed an efficient deuteration method that targets all 20 proteinogenic amino acids, including their side chains. Using a Pt/C-catalyzed hydrogen–deuterium exchange reaction, the reaction parameters were optimized to achieve the selective and stable incorporation of deuterium. In addition, the resulting deuterated compounds, focusing on tryptophan, were characterized in order to assess their physicochemical properties. Because the deuteration reaction caused significant racemization of amino acids, deuterated D/L-tryptophan was isolated using a chiral separation method. Deuterated tryptophan characterization studies confirmed that the photostability was markedly enhanced by deuteration, whereas the acid stability showed no clear isotopic effect. The X-ray crystal structure analyses revealed minimal changes upon the hydrogen-to-deuterium substitution. These results provide a robust platform for the supply of deuterated amino acids, facilitating their application in drug development, structural analysis, and creation of advanced functional biomaterials.
- 25 July 2025
- Published by MDPI AG in Preprints.org
Open AccessDevelopment of the Direct Deuteration Method for Amino Acids and Characterization of Deuterated Tryptophan
Proteins and peptides are essential biomolecules involved in the maintenance of biological functions and disease development. Their structural and functional analyses are crucial for drug discovery and pathology. Amino acids, the fundamental building blocks of these biomolecules, are increasingly utilized in deuterated forms in diverse fields, such as metabolic tracing and neutron scattering studies. In this study, we have developed an efficient deuteration method that targets all 20 proteinogenic amino acids, including their side chains. Using a Pt/C-catalyzed hydrogen–deuterium exchange reaction, the reaction parameters were optimized to achieve the selective and stable incorporation of deuterium. In addition, the resulting deuterated compounds, focusing on tryptophan, were characterized in order to assess their physicochemical properties. Because the deuteration reaction caused significant racemization of amino acids, deuterated D/L-tryptophan was isolated using a chiral separation method. Deuterated tryptophan characterization studies confirmed that the photostability was markedly enhanced by deuteration, whereas the acid stability showed no clear isotopic effect. The X-ray crystal structure analyses revealed minimal changes upon the hydrogen-to-deuterium substitution. These results provide a robust platform for the supply of deuterated amino acids, facilitating their application in drug development, structural analysis, and creation of advanced functional biomaterials.
- Open Access
- 16 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
Development of a compact in-situ 3He neutron spin filter at J-PARC
- 16 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
Open AccessDevelopment of a compact in-situ 3He neutron spin filter at J-PARC
- Open Access
- 14 March 2025
- Published by Springer Nature in The European Physical Journal D
- Vol. 79 (3) , 1-15
Precision measurements of muonium and muonic helium hyperfine structure at J-PARC
At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is now performing new precision measurements of the ground state hyperfine structure (HFS) of both muonium and muonic helium atoms. High-precision measurements of the muonium ground-state HFS are recognized as one of the most sensitive tools for testing bound-state quantum electrodynamics theory to precisely probe the standard model and determine fundamental constants of the positive muon magnetic moment and mass. The same technique can also be employed to measure muonic helium HFS, obtain the negative muon magnetic moment and mass, and test and improve the theory of the three-body atomic system. Measurements at zero magnetic field have already yielded more accurate results than previous experiments for both muonium and muonic helium atoms. High-field measurements are now ready to start collecting data using the world’s most intense pulsed muon beam at the MUSE H-line. We aim to improve the precision of previous measurements ten times for muonium and a hundred times or more for muonic helium. We review all the key developments for these new measurements, focusing on the high-field experiment, and report the latest results and prospects.
- 14 March 2025
- Published by Springer Nature in The European Physical Journal D
- Vol. 79 (3) , 1-15
Open AccessPrecision measurements of muonium and muonic helium hyperfine structure at J-PARC
At the J-PARC Muon Science Facility (MUSE), the MuSEUM collaboration is now performing new precision measurements of the ground state hyperfine structure (HFS) of both muonium and muonic helium atoms. High-precision measurements of the muonium ground-state HFS are recognized as one of the most sensitive tools for testing bound-state quantum electrodynamics theory to precisely probe the standard model and determine fundamental constants of the positive muon magnetic moment and mass. The same technique can also be employed to measure muonic helium HFS, obtain the negative muon magnetic moment and mass, and test and improve the theory of the three-body atomic system. Measurements at zero magnetic field have already yielded more accurate results than previous experiments for both muonium and muonic helium atoms. High-field measurements are now ready to start collecting data using the world’s most intense pulsed muon beam at the MUSE H-line. We aim to improve the precision of previous measurements ten times for muonium and a hundred times or more for muonic helium. We review all the key developments for these new measurements, focusing on the high-field experiment, and report the latest results and prospects.
- 12 March 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (3)
Transverse asymmetry of individual rays in the reaction- 12 March 2025
- Published by American Physical Society (APS) in Physical Review C
- Vol. 111 (3)
Transverse asymmetry of individual rays in the reaction- Open Access
- 9 August 2024
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2024 (9)
Performance of the Fully Equipped Spin Flip Chopper for the Neutron Lifetime Experiment at J-PARC
To solve the “neutron lifetime puzzle,” where measured neutron lifetimes differ depending on the measurement methods, an experiment with a pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250–400, which is comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in the statistics will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.
- 9 August 2024
- Published by Oxford University Press (OUP) in Progress of Theoretical and Experimental Physics
- Vol. 2024 (9)
Open AccessPerformance of the Fully Equipped Spin Flip Chopper for the Neutron Lifetime Experiment at J-PARC
To solve the “neutron lifetime puzzle,” where measured neutron lifetimes differ depending on the measurement methods, an experiment with a pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250–400, which is comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in the statistics will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.