MEMohamed Elshirbeny Elawsya

Mohamed Elshirbeny Elawsya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohamed Elshirbeny Elawsya has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Abeer ElSayed ElEmbaby

    Department of Conservative Dentistry, Faculty of Dentistry, Mansoura University, Mansoura, Egypt

    3 shared publications
  • Nadia Mohamed Zaghloul

    Mansoura Univ, Fac Dent, Dept Operat Dent, Algomhoria St, Mansoura 35516, Egypt

    2 shared publications
  • A. Ali

    Associate Professor, Department of Conservative Dentistry, Faculty of Dentistry, Mansoura University, Egypt

    1 shared publication
  • Abeer El Sayed El Embaby

    Mansoura Univ, Fac Dent, Dept Conservat Dent, Algomhoria St,POB 35516, Mansoura, Aldakhlia, Egypt

    1 shared publication
  • Abeer ElSayed ElEmbaby

    Department of Conservative Dentistry, Faculty of Dentistry Mansoura University Mansoura Egypt

    1 shared publication
  • Adham Essam Nassar

    College of Liberal Arts and Sciences, University of Florida, Gainesville, USA

    1 shared publication

Latest Publications

  • Color Matching and Surface Roughness of Initial Enamel Caries After Treatment With Different Remineralizing Agents

    by Tarek Adel Arisha, Mohamed Elshirbeny Elawsya, Abeer ElSayed ElEmbaby

    Objectives: To evaluate and compare the effect of four different remineralizing agents on color matching and surface roughness of initial enamel caries. Materials and Methods: Forty maxillary central incisors were allocated into four groups ( n = 10) according to the remineralizing agent used: Curodont Repair Fluoride Plus, 10% nano‐hydroxyapatite, 10% nano‐bioactive glass, and Fluor Protector S. Artificial caries lesions were induced by immersion in a demineralizing solution. Color was assessed using a spectrophotometer, and surface roughness was measured with a contact profilometer. Data were analyzed using one‐way ANOVA and Tukey's post hoc tests ( p < 0.05). Results: Fluor Protector S exhibited the highest color change (ΔE₀₀), whereas Curodont Repair Fluoride Plus showed the lowest. Curodont Repair Fluoride Plus significantly reduced surface roughness compared with the other groups, while Fluor Protector S showed the highest roughness values. Conclusions: The greatest color‐masking effect was observed with Curodont Repair Fluoride Plus and 10% nano‐bioactive glass. Nevertheless, none of the tested treatments was able to completely restore the original enamel color. Flour Protector S showed the least effect in restoring surface smoothening compared to other materials, while Curodont Repair Fluoride Plus showed the greatest effect in reducing surface roughness of initial enamel caries. Clinical Significance: Curodont Repair Fluoride Plus may be recommended for the management of initial enamel caries due to its enhanced ability to promote favorable color integration and surface smoothening compared to other remineralizing agents, contributing to improved clinical outcomes.

  • Open Access

    Dentin Bonding Performance, Nanoleakage, and Micromorphological Characteristics of Universal Adhesives in Self-etch Mode: Comparative Evaluation

    by Maryam Wessam, Mohamed Elshirbeny Elawsya, Mansoura Taher Mahmoud Elkotb, Hamdi Hamama, Salah Hasab Mahmoud

    The current study aimed to evaluate and compare the microtensile bond strength (µTBS), nanoleakage, and micromorphological characteristics of six universal adhesives (UAs) applied in self-etch (SE) mode to dentin. The occlusal one-third of 60 freshly extracted intact human molars was removed, and the exposed surfaces were treated with one of the six UAs (Gluma Bond [GB], Zipbond Universal [ZB], Scotchbond Universal Plus [SB + ], Single Bond Universal [SB], Futurabond U [FB], or OptiBond eXTRa Universal [OB]) in SE mode (n = 10). After resin composite build-up (Tetric N Ceram Bulk-Fill), specimens were subjected to 5,000 thremocycles and stored in artificial saliva in an incubator for 24 h. For each group, composite resin–dentin beams were prepared (n = 56) from seven specimens and the µTBS test was performed. The failure patterns of the debonded specimens were investigated using a stereo binuclear microscope (x = 30). Data were analyzed using one-way ANOVA and Tukey's significant difference (HSD) tests at a significance level of p < 0.05. The remaining specimens from each group (n = 3) were sectioned in mesio-distal direction. Buccal sections were immersed into ammoniacal silver nitrate followed by a photodeveloper under a fluorescent light and then investigated using scanning electron microscope (SEM) in backscattered mode. Lingual sections were used for assessing the micromorphological pattern of adhesive–dentin interface using SEM in secondary electron mode. One-way ANOVA test indicated a significant difference in the microtensile bond strength among the types of the tested adhesives (p < 0.05). SB+ demonstrated the highest bond strength among all tested adhesives (p < 0.05). SB also showed significantly higher bond strength compared with the other tested adhesives, except for OB (p = 0.317). No statistically significant differences were observed among FB, GB, ZB, and OB (p > 0.05). Regarding nanoleakage patterns, GB showed the highest degree while the lowest nanoleakage pattern was exhibited in OB. Resin–dentin interface exhibited the highest massive amount of resin tags in SB+ and the least amount of resin tags in FB followed by ZB. Based on the extracted results, UA bonding performance was material dependent. The number and depth of resin tags were found to correlate with bond strength, whereas nanoleakage patterns showed no such correlation.

  • Open Access

    Surface roughness and wear resistance of ormocer- versus methacrylate-based single-shade resin composites after simulated tooth brushing

    by Maha M. Ebaya, Mohamed Elshirbeny Elawsya

    Background: To evaluate and compare the surface roughness and wear resistance of ormocer-based and methacrylate-based single-shade resin composites after simulated tooth brushing. Methods: Two single-shade composites; an ormocer-based composite (Admira Fusion X-tra, Voco) and a methacrylate-based composite (Omnichroma, Tokuyama), were used in this study. From each material, 20 disc-shaped specimens (3-mm thickness, 5-mm diameter) were prepared ( n = 20). Specimens were subjected to 100,000 cycles of tooth brushing with a Colgate Max Fresh dentifrice (Colgate-Palmolive). The surface roughness was assessed before and after tooth brushing, and the changes in weight were determined after tooth brushing. Additional two specimens from each composite underwent scanning electron microscope (SEM) imaging. Paired and unpaired Student’s t -tests were used for statistical analysis ( p < 0.05). Results: Surface roughness of both tested composites increased significantly after brushing ( p = 0.002 for ormocer-based composite and p = 0.006 for methacrylate-based composite). However, there was no statistically significant difference among the two tested composites regarding surface roughness before brushing ( p = 0.928) or after brushing ( p = 0.696). The weights of both tested composites decreased significantly after brushing ( p = 0.001), and the amount of methacrylate-based composite wear was significantly higher than that of the ormocer-based composite ( p < 0.001). Conclusion: After simulated tooth brushing, both tested composites (ormocer-based and methacrylate-based) became rougher, whereas the ormocer-based composite exhibited greater wear resistance than did the methacrylate-based composite.


  • Open Access

    Effect of immersion in different media on the color stability, surface roughness, and microhardness of flowable nanohybrid resin composites

    by Hend Yousri Abd-Elfattah, Mohamed Elshirbeny Elawsya, Abeer ElSayed ElEmbaby

    Background: To evaluate color stability, surface roughness, and microhardness of flowable nanohybrid resin composites following immersion in different media. Methods: Polofil NHT Flow (VOCO GmbH), G-aenial Universal Injectable (GC DENTAL PRODUCTS CORP), and Tetric N-Ceram (Ivoclar Vivadent) were used. From each tested resin composite, 50 disc-shaped specimens (10-mm diameter × 2-mm thickness) were performed. Each group was categorized into five subgroups according to immersion media ( n = 10): (1) control (without immersion), (2) artificial saliva, (3) coffee, (4) cola, and (5) energy drink. Color stability, surface roughness, and microhardness were evaluated. Data were analyzed through two-way ANOVA, Tukey’s post-hoc, and Pearson correlation coefficient tests ( p < 0.05). Results: For color change, no statistically significant differences were observed among the resin composites regarding artificial saliva ( p = 0.78), coffee ( p = 0.93), and cola ( p = 0.09), while there was a significant difference between them regarding energy drink ( p < 0.05). The highest surface roughness mean value was recorded with Polofil NHT Flow, which showed an increase in surface roughness after immersion in energy drink (0.32 ± 0.06 μm) compared to the control subgroup (0.22 ± 0.08 μm). For all resin composites, there were significant reductions in microhardness with all immersion media in comparison to the control subgroups ( p < 0.05). Conclusions: For color stability, energy drink and coffee had the most negative effect on all tested resin composites. Energy drink caused the highest discoloration with G-aenial Universal Injectable and the highest roughness with Polofil NHT Flow. All tested resin composites showed a decrease in surface microhardness following immersion in all tested immersion media.


  • Open Access

    Impact of different polishing techniques on surface roughness, gloss, and microhardness of zirconium oxide reinforced flowable bulk-fill resin composite: an in vitro study

    by Amr Elsayed Elnahas, Mohamed Elshirbeny Elawsya, Abeer ElSayed ElEmbaby

    Background: To evaluate the impact of different polishing systems on surface roughness (SR), surface gloss (SG), and vickers microhardness (VMH) of flowable bulk-fill composites reinforced with zirconium oxide fillers. Methods: Two flowable bulk-fill composites reinforced with zirconium oxide fillers (PALFIQUE BULK FLOW, Filtek Bulk Fill Flowable) and another one with conventional fillers (Tetric N-Flow Bulk Fill) were used. For each tested material, 40 cylindrical specimens (8-mm diameter, 4-mm height) were prepared. Specimens were divided into 4 subgroups according to polishing system used (n = 10/subgroup): subgroup I; Mylar strip (control), subgroup II; 1-step polishing system, subgroup III; 2-step polishing system, and subgroup IV; multi-step polishing system. Surface roughness was evaluated with a 3D noncontact optical profilometer. Gloss was evaluated with a glossmeter. Microhardness was evaluated with a Vickers Microhardness tester. Statistical analysis was performed using two-way ANOVA, Bonferroni, and Pearson correlation coefficient testes (p < 0.05). Results: For surface roughness, there was no significant difference between groups for control and 1-step (p = 0.152 for control, p = 0.296 for 1-step), while there was a significant difference for 2-step and multi-step (p = 0.025 for 2-step, p = 0.001 for multi-step). For gloss, there was no significant difference between groups for 1-step and 2-step (p = 0.124 for 1-step, p = 0.226 for 2-step), while there was a significant difference for control and multi-step (p = 0.001 for control, p < 0.001 for multi-step). For microhardness, there was no significant difference between groups for control (p = 0.245), while there was a significant difference for the other techniques (p < 0.001 for 1-step and 2-step, p = 0.001 for multi-step). Conclusions: Reinforcement with zirconium oxide fillers improved flowable bulk-fill composites in terms of surface roughness, gloss, and microhardness. Surface gloss and microhardness were significantly influenced by material type and polishing system used, while surface roughness was influenced only by polishing system used.


  • Open Access

    Impact of silica nanoparticles incorporation on the properties of resin infiltration: an in vitro study

    by Abeer ElSayed ElEmbaby, Adham Essam Nassar, Mohamed Elshirbeny Elawsya

    Background: This study evaluated the effect of nano-silica (NS) incorporation with resin infiltrant on water sorption and solubility of resin infiltrant, mineral density of demineralized enamel, and resin tags penetration. Methods: NS (Sigma-Aldrich, St Louis, Missouri, USA) was added into the resin infiltrant (ICON, DMG, Hamburg, Germany) at two concentrations by weight. The tested groups were: ICON (control), ICON + 0.2, and ICON + 0.5 (n = 10 per group). Water sorption and solubility were assessed using mass variation after 60 days water storage. Mineral density and surface topography were assessed using micro-Computed Tomography scans. Resin tags penetration was measured using a scanning electron microscope. Data were analyzed using one-way Analysis of Variance and Tukey’s post-hoc tests (P < .05). Results: ICON revealed the highest water sorption, solubility mean values (28.90, 7.61) followed by ICON + 0.2 (14.80, 4.82) and ICON + 0.5 (12.32, 0.81) respectively, and vice versa for resin tags penetration. Mineral density of demineralized enamel significantly increased after treatment with ICON + 0.2 and ICON + 0.5. Conclusion: Incorporation of NS to resin infiltrant decreased its water sorption and solubility along with enhancing the mineral density of the demineralized enamel and the penetration of resin tags.


  • Open Access

    Influence of curing mode and aging on the bonding performance of universal adhesives in coronal and root dentin

    by Hoda Saleh Ismail, Ashraf Ibrahim Ali, Mohamed Elshirbeny Elawsya

    Background: This study aims to evaluate the microtensile bond strength (µTBS) of different resin composite restorations bonded to mid-coronal dentin and proximal root dentin using light-cured, chemical-cured, and dual-cured adhesives immediately and after aging. Nanoleakage and degree of cure were also assessed. Methods: Eighty-four molars were divided into mid-coronal dentin and proximal root dentin. Each group was further subdivided into three subgroups based on the restorative systems used, which involved the utilization of light-cured, chemical-cured, and dual-cured adhesives. Half of the specimens underwent µTBS testing after 24 h, while the other half after aging. Representative specimens were analyzed for nanoleakage. The degree of cure of the tested adhesive systems was also assessed. Results: Aging showed a significant negative effect on µTBS results and led to increased nanoleakage (p < 0.001). Furthermore, in all subgroups, the µTBS values of proximal root dentin were lower compared to mid-coronal dentin, except in the aged subgroup for the system utilizing the dual-cured adhesive. The restorative systems with chemical and dual-cured adhesives demonstrated comparable bonding properties. However, the system with the light-cured adhesive exhibited the worst bonding properties after aging when bonded to proximal root dentin and cured at a large distance (p < 0.05). Conclusions: All tested restorative systems were negatively affected by aging, and the regional dentin had variable effects on the bonding properties. Clinicians should exercise caution when using the tested light-cured adhesive in areas where the curing distance exceeds 3 mm.


  • Polymerization efficiency of different bulk-fill resin composites cured by monowave and polywave light-curing units: a comparative study

    by Rahma Mohamed Elsharawy, Mohamed Elshirbeny Eawsya, Asmaa Mohamed Abd Allah, Abeer El Sayed El Embaby

    Objectives: The objective was to evaluate the polymerization efficiency of different bulk-fill resin-based composites cured by monowave and polywave light-curing units, by assessment of the degree of conversion and Vickers microhardness at different depths. Method and materials: Two commercially available bulk-fill resin-based composites were used: Filtek One Bulk Fill Restorative (3M ESPE) and Tetric N-Ceram Bulk Fill (IvoclarVivadent). The light-curing units utilized were two LED light-curing units: a monowave LED light-cu ring unit (BlueLEX LD-105, Monitex) and a polywave LED light-curing unit (Twin Wave GT-2000, Monitex). For each test, 20 cylindrical specimens (4 mm diameter, 4 mm thickness) were prepared from each bulk-fill resin-based composite using a Split Teflon mold. Ten specimens were light-cured by the monowave light-curing unit and the other ten were light-cured by the polywave light-cu ring u nit according to the manufacturer's recommendations. Attenuated total reflectance-Fourier t ra nsform infra red spectroscopy (ATRFTI R) was used to assess the degree of conversion, and a Vickers m icroha rd ness teste r was used to assess Vickers microhardness. Statistical analysis was performed using three-way ANOVA and Tu key post-hoc tests (P < .05). Results: The degree of conversion and Vickers microhardness in bulk-fill resin-based composites containing only camphorquinone as photoinitiator were similar when cured with either monowave or polywave light-curing units. However, bulk-fill resin-based composites containing a combination of photoinitiators exhibited significantly higher degree of conversion and Vickers microhardness when cured with a polywave light-curing unit. Although aII groups showed statistically significant differences between the top and bottom surfaces regarding degree of conversion and Vickers microhardness, aII of them showed bottom/top ratios > 809/o regarding degree of conversion and Vickers microhardness. Conclusion: The polywave light-curing unit enhanced the polymerization efficiency of bulk-fill resin-based composites especially when the latter contained a combination of photoinitiators, but does not preventtheuseofa monowave light-curing u nit. (Quintessencelnt 2024;55:264-272; dok 10.3290/j.gi.b4984231)


  • Open Access

    Two-year clinical performance of dual- and light-cure bulk-fill resin composites in Class ӀӀ restorations: a randomized clinical trial

    by Mohamed Elshirbeny Elawsya, Marmar Ahmed Montaser, Noha Abdel-Mawla El-Wassefy, Nadia Mohamed Zaghloul

    Objective: This study aimed to compare the clinical performance of dual- and light-cure bulk-fill resin composites (BFRCs) in Class ӀӀ restorations after 2 years. Materials and methods: A double-blinded, prospective, randomized clinical trial (RCT) was conducted following the CONSORT (Consolidated Standard of Reporting Trials) guidelines. Forty patients were enrolled in the study. Each patient received three compound Class ӀӀ restorations. One dual-cure (Fill-Up; Coltene Waledent AG) and two light-cure (QuiXfil; Dentsply, and Tetric N-Ceram Bulk Fill; Ivoclar Vivadent) BFRCs were used for 120 Class ӀӀ restorations. A universal adhesive (ONE COAT 7 UNIVERSAL; Coltene Waledent AG) was used with all restorations. Restorations were clinically evaluated after 1 week (baseline), 6 months, 12 months, 18 months, and finally after 24 months using the FDI World Dental Federation (FDI) criteria. The Kruskal–Wallis test was used for comparison between BFRCs groups at baseline and at each recall period, and the Wilcoxon signed-rank test was used for comparing different follow-up times of each BFRC to baseline. The level of significance was set at p < 0.05. Results: All BFRCs restorations showed only minor changes and revealed no statistically significant differences between their clinical performance for all evaluated parameters at all recall periods; also, there was no statistically significant difference between all recall periods and baseline for all evaluated parameters. Conclusion: The two-year clinical performance of dual-cure BFRC was comparable to light-cure BFRCs in Class ӀӀ restorations. Clinical relevance: Dual- and light-cure BFRCs showed excellent clinical performance in Class ӀӀ restorations after a 2-year clinical follow-up.


  • Open Access

    Microleakage of Lithium Disilicate Veneers Bonded to Different Substrates with Light-cure and Dual-cure Resin Cements

    by B. Albaheli, M. Elawsya, A. Ali

    This study aimed to evaluate the microleakage of lithium disilicate veneers with finish lines placed cervically in different substrates (enamel, dentin, and resin composite) and bonded with light-cure (LC) and amine-free dual-cure (DC) resin cements. Forty-eight human maxillary central incisors were randomly assigned into three groups according to finish line substrate (n=16/group). Each group was subdivided randomly into two subgroups (n=8/subgroup) according to resin cement type: LC resin cement (Variolink Esthetic LC, Ivoclar Vivadent) and DC resin cement (Variolink Esthetic DC, Ivoclar Vivadent). All the specimens received lithium disilicate veneers (IPS e.max Press, Ivoclar Vivadent). After 5000 cycles of thermocycling, the microleakage was measured using the dye penetrating technique. Data were analyzed statistically using Scheirer Ray Hare test, Kruskal-Wallis H-test, and Mann-Whitney U-test. The level of significance was set at p ≤ .05. There was a statistically significant difference between different substrates in microleakage (p=.001), but there was no statistically significant difference between resin cements (p=.907), and there was no interaction between substrates and resin cements (p=.983). Microleakage was lesser when the finish line was placed at enamel and resin composite than at dentin. Similar leakage scores were observed with LC and DC resin cements. The finish line of ceramic veneer is suggested to be placed in enamel or good-quality resin composite restoration. Regarding microleakage and durability, LC and amine-free DC resin cements are suggested for ceramic veneer cementation. Key words:Different substrates, Dual-cure resin cement, Light-cure resin cement, Lithium disilicate veneers, Microleakage.