Winfried Barth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Winfried Barth has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
- Stepan Yaramyshev
GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt, Germany
8 shared publications M. Heilmann
GSI Helmholtz Center for Heavy Ion Research 2 , Darmstadt 64291, Germany
5 shared publications- Simon Lauber
Linac Department, GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt, Germany
5 shared publications A. Rubin
GSI Helmholtz Center for Heavy Ion Research 2 , Darmstadt 64291, Germany
4 shared publicationsF. Dziuba
Helmholtz Institute Mainz 1 , Mainz 55128, Germany
4 shared publicationsH. Vormann
GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt, Germany
4 shared publications
Latest Publications
- Open Access
- 21 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8422
DYNAMION—A Powerful Beam Dynamics Software Package for the Development of Ion Linear Accelerators and Decelerators
Numerous ambitious particle accelerator facilities, based on proton and ion linear accelerators, have recently been in development for fundamental research, as well as for industrial applications. The advanced design of such new machines, as well as the upgrade and optimization of existing linacs, requires adequate, precise and reliable tools to simulate beam dynamics. The software package DYNAMION, created about 30 years ago, is undergoing systematic improvement and further development in order to characterize modern ion linacs and to provide solutions for its intrinsic complex problems. The DYNAMION code features Front to End beam dynamics simulations under space charge conditions in a linac system, comprising an arbitrary sequence of accelerating-focusing structures and beam transport lines. The evolution of a macroparticle ensemble could be analyzed at a high level of specification. A 3D distribution of the external electrical field (RFQ, DTL) is modeled using integrated internal solvers. Optionally, a 3D electromagnetic field mapping, supplied by specialized external codes, could be used. The recent status of the DYNAMION software package is presented in this paper. Furthermore, the performance of the code is demonstrated on the basis of its application for various linear accelerator/decelerator projects.
- 21 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8422
Open AccessDYNAMION—A Powerful Beam Dynamics Software Package for the Development of Ion Linear Accelerators and Decelerators
Numerous ambitious particle accelerator facilities, based on proton and ion linear accelerators, have recently been in development for fundamental research, as well as for industrial applications. The advanced design of such new machines, as well as the upgrade and optimization of existing linacs, requires adequate, precise and reliable tools to simulate beam dynamics. The software package DYNAMION, created about 30 years ago, is undergoing systematic improvement and further development in order to characterize modern ion linacs and to provide solutions for its intrinsic complex problems. The DYNAMION code features Front to End beam dynamics simulations under space charge conditions in a linac system, comprising an arbitrary sequence of accelerating-focusing structures and beam transport lines. The evolution of a macroparticle ensemble could be analyzed at a high level of specification. A 3D distribution of the external electrical field (RFQ, DTL) is modeled using integrated internal solvers. Optionally, a 3D electromagnetic field mapping, supplied by specialized external codes, could be used. The recent status of the DYNAMION software package is presented in this paper. Furthermore, the performance of the code is demonstrated on the basis of its application for various linear accelerator/decelerator projects.
- Open Access
- 21 April 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (4) , 040101
High brilliance beam investigations at the universal linear accelerator
The more than 45-year-old GSI-UNILAC (universal linear accelerator) as well as the heavy ion synchrotron SIS18 will serve as a high-current heavy ion injector for the new Facility for Antiproton and Ion Research (FAIR) synchrotron SIS100. UNILAC will serve together with the SIS18 as FAIR injector for short intense pulse operation; the newly developed heavy ion linac Helmholtz linear accelerator shall deliver cw beams, still required for the comprehensive research program at GSI. In the context of an advanced machine investigation program in combination with the ongoing UNILAC upgrade program, a dedicated beam investigation campaign has been carried out in order to characterize front-to-end high-current medium and heavy ion beam behavior at GSI-UNILAC. A very high beam brilliance at the end of transfer line from UNILAC to SIS18 was achieved recently for medium heavy ion beams in a machine experiment campaign. This is an important step paving the way to fulfill the FAIR heavy ion high-intensity beam requirements. Results of high-current uranium beam measurements applying the novel technique of pulsed hydrogen gas stripping (at ) will be presented as well.- 21 April 2022
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 25 (4) , 040101
Open AccessHigh brilliance beam investigations at the universal linear accelerator
The more than 45-year-old GSI-UNILAC (universal linear accelerator) as well as the heavy ion synchrotron SIS18 will serve as a high-current heavy ion injector for the new Facility for Antiproton and Ion Research (FAIR) synchrotron SIS100. UNILAC will serve together with the SIS18 as FAIR injector for short intense pulse operation; the newly developed heavy ion linac Helmholtz linear accelerator shall deliver cw beams, still required for the comprehensive research program at GSI. In the context of an advanced machine investigation program in combination with the ongoing UNILAC upgrade program, a dedicated beam investigation campaign has been carried out in order to characterize front-to-end high-current medium and heavy ion beam behavior at GSI-UNILAC. A very high beam brilliance at the end of transfer line from UNILAC to SIS18 was achieved recently for medium heavy ion beams in a machine experiment campaign. This is an important step paving the way to fulfill the FAIR heavy ion high-intensity beam requirements. Results of high-current uranium beam measurements applying the novel technique of pulsed hydrogen gas stripping (at ) will be presented as well. - Open Access
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113306
A dynamic collimation and alignment system for the Helmholtz linear accelerator
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
- 1 November 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (11) , 113306
Open AccessA dynamic collimation and alignment system for the Helmholtz linear accelerator
The upcoming commissioning of the superconducting (SC) continuous wave Helmholtz linear accelerators first of series cryomodule is going to demand precise alignment of the four internal SC cavities and two SC solenoids. For optimal results, a beam-based alignment method is used to reduce the misalignment of the whole cryomodule, as well as its individual components. A symmetric beam of low transverse emittance is required for this method, which is to be formed by a collimation system. It consists of two separate plates with milled slits, aligned in the horizontal and vertical direction. The collimation system and alignment measurements are proposed, investigated, and realized. The complete setup of this system and its integration into the existing environment at the GSI High Charge State Injector are presented, as well as the results of the recent reference measurements.
- Open Access
- 30 December 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (12) , T12012
LINAC developments for heavy ion operation at GSI and FAIR
The first cavity of a standalone superconducting (sc) continuous wave (cw) heavy ion Linac as a demonstration of the capability of 217 MHz multi gap Crossbar H-mode structures (CH) has been already commissioned at high acceleration gain. The worldwide first beam test with a superconducting multi gap CH-cavity was a milestone of the R&D work of HIM and GSI in collaboration with Goethe University Frankfurt (GUF) in preparation of the sc cw heavy ion Linac project, substituting GSI-UNILAC as a heavy ion high duty factor Linac. Recently the first two of four fully equipped cw-Linac cryomodules are in procurement. To meet the future FAIR science requirements higher beam intensity has to be achieved in the present GSI-accelerator complex. In the last years ion source developments, in particular for the high current Vacuum Arc Ion Sources (VARIS), were concentrated on heavy elements, as Bi and Pb, aiming for stable routine ion source operation at a sufficient rep. rate and high production efficiency. Stripping is a key technology for all heavy ion accelerators. After upgrade of the supersonic N 2 -gas jet implementation of high current foil stripping, recently a new H 2 gas cell, using a pulsed gas regime synchronized with arrival of the beam pulse has been developed. An enhanced stripper gas density as well as a simultaneously reduced gas load results in an increased stripping efficiency, while the beam emittance remains the same. A new record beam intensity (11.1 emA) for 238 U 28+ beams at 1.4 MeV/u has been achieved, applying the pulsed high density H 2 -stripper target to a high intensity 238 U 4+ beam from the VARIS ion source. Further ion source developments have been accomplished recently providing for sufficient heavy ion beam intensities at the High Current Injector Linac. A machine investigation program has been performed in 2020. The focus was to optimize the entire FAIR injector chain for high intensity heavy ion beam after the successful implementation of different upgrade measures. Besides a dedicated operation mode applying UNILAC, as a heavy ion Linac, at a synchronous phase significantly lower than 30 degrees for high intensity proton beam, could be established. Thus, UNILAC is able to deliver a sufficient proton beam intensity for the FAIR commissioning phase, when the FAIR-proton Linac is not yet available.
- 30 December 2020
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 15 (12) , T12012
Open AccessLINAC developments for heavy ion operation at GSI and FAIR
The first cavity of a standalone superconducting (sc) continuous wave (cw) heavy ion Linac as a demonstration of the capability of 217 MHz multi gap Crossbar H-mode structures (CH) has been already commissioned at high acceleration gain. The worldwide first beam test with a superconducting multi gap CH-cavity was a milestone of the R&D work of HIM and GSI in collaboration with Goethe University Frankfurt (GUF) in preparation of the sc cw heavy ion Linac project, substituting GSI-UNILAC as a heavy ion high duty factor Linac. Recently the first two of four fully equipped cw-Linac cryomodules are in procurement. To meet the future FAIR science requirements higher beam intensity has to be achieved in the present GSI-accelerator complex. In the last years ion source developments, in particular for the high current Vacuum Arc Ion Sources (VARIS), were concentrated on heavy elements, as Bi and Pb, aiming for stable routine ion source operation at a sufficient rep. rate and high production efficiency. Stripping is a key technology for all heavy ion accelerators. After upgrade of the supersonic N 2 -gas jet implementation of high current foil stripping, recently a new H 2 gas cell, using a pulsed gas regime synchronized with arrival of the beam pulse has been developed. An enhanced stripper gas density as well as a simultaneously reduced gas load results in an increased stripping efficiency, while the beam emittance remains the same. A new record beam intensity (11.1 emA) for 238 U 28+ beams at 1.4 MeV/u has been achieved, applying the pulsed high density H 2 -stripper target to a high intensity 238 U 4+ beam from the VARIS ion source. Further ion source developments have been accomplished recently providing for sufficient heavy ion beam intensities at the High Current Injector Linac. A machine investigation program has been performed in 2020. The focus was to optimize the entire FAIR injector chain for high intensity heavy ion beam after the successful implementation of different upgrade measures. Besides a dedicated operation mode applying UNILAC, as a heavy ion Linac, at a synchronous phase significantly lower than 30 degrees for high intensity proton beam, could be established. Thus, UNILAC is able to deliver a sufficient proton beam intensity for the FAIR commissioning phase, when the FAIR-proton Linac is not yet available.
- Open Access
- 13 November 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (11) , 114201
Longitudinal phase space reconstruction for a heavy ion accelerator
At the GSI Helmholtzzentrum fur Schwerionenforschung (GSI) in Darmstadt, Germany, a prototype cryomodule (advanced demonstrator) for the superconducting (SC) continuous wave (CW) Helmholtz Linear Accelerator (HELIAC) is under construction. A transport line, comprising quadrupole lenses, rebuncher cavities, beam correctors, and adequate beam instrumentation has been built to deliver the beam from the GSI 1.4 MeV/u High Charge Injector (HLI) to the advanced demonstrator, which offers a test environment for SC CW multigap cavities. In order to achieve proper phase space matching, the beam from the HLI must be characterized in detail. In a dedicated machine experiment the bunch shape has been measured with a nondestructive bunch shape monitor (BSM). Therefore, different bunch projections were obtained by altering the voltage of two rebunchers. These measurements were combined with dedicated beam dynamics simulations using the particle tracking code DYNAMION. The longitudinal bunch shape and density distribution at the beginning of the matching line are fully characterized by a tomographic reconstruction method based on a non-negative least square minimization approach.
- 13 November 2020
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 23 (11) , 114201
Open AccessLongitudinal phase space reconstruction for a heavy ion accelerator
At the GSI Helmholtzzentrum fur Schwerionenforschung (GSI) in Darmstadt, Germany, a prototype cryomodule (advanced demonstrator) for the superconducting (SC) continuous wave (CW) Helmholtz Linear Accelerator (HELIAC) is under construction. A transport line, comprising quadrupole lenses, rebuncher cavities, beam correctors, and adequate beam instrumentation has been built to deliver the beam from the GSI 1.4 MeV/u High Charge Injector (HLI) to the advanced demonstrator, which offers a test environment for SC CW multigap cavities. In order to achieve proper phase space matching, the beam from the HLI must be characterized in detail. In a dedicated machine experiment the bunch shape has been measured with a nondestructive bunch shape monitor (BSM). Therefore, different bunch projections were obtained by altering the voltage of two rebunchers. These measurements were combined with dedicated beam dynamics simulations using the particle tracking code DYNAMION. The longitudinal bunch shape and density distribution at the beginning of the matching line are fully characterized by a tomographic reconstruction method based on a non-negative least square minimization approach.
- 23 June 2020
- Published by IOP Publishing in Physica Scripta
- Vol. 95 (8) , 084006
Current progress on ion driver LINAC-100 development for the new rare isotope facility DERICA at JINR
A new ambitious facility DERICA (Dubna Electron—Rare Ion Collider fAcility) was proposed recently in worldwide collaboration. A number of accelerators for various scientific applications will be built for this project and among them a driver-accelerator LINAC-100 capable of accelerating high-intensity beams of primary stable isotopes up to 100 MeV u −1 . This paper contains current results on one of the LINAC-100 versions R&D: parameters of the front-end RFQ section, analysis on the stripper sections and optimal stripping energies,the layout of the superconducting part of LINAC-100 and Uranium beam dynamics simulation results.
- 23 June 2020
- Published by IOP Publishing in Physica Scripta
- Vol. 95 (8) , 084006
Current progress on ion driver LINAC-100 development for the new rare isotope facility DERICA at JINR
A new ambitious facility DERICA (Dubna Electron—Rare Ion Collider fAcility) was proposed recently in worldwide collaboration. A number of accelerators for various scientific applications will be built for this project and among them a driver-accelerator LINAC-100 capable of accelerating high-intensity beams of primary stable isotopes up to 100 MeV u −1 . This paper contains current results on one of the LINAC-100 versions R&D: parameters of the front-end RFQ section, analysis on the stripper sections and optimal stripping energies,the layout of the superconducting part of LINAC-100 and Uranium beam dynamics simulation results.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012075
Advanced Beam Dynamics Design for the Superconducting Heavy Ion Accelerator HELIAC
The standalone superconducting (SC) continuous wave (CW) heavy ion linac HELIAC (HElmholtz LInear ACcelerator) is a common project of GSI and HIM under key support of IAP Frankfurt and in collaboration with Moscow Engineering Physics Institute (MEPhI) and Moscow Institute for Theoretical and Experimental Physics (KI-ITEP). It is intended for future experiments with heavy ions near the Coulomb barrier within super-heavy element (SHE) research and aims at developing a linac with multiple CH cavities as key components downstream the High Charge State Injector (HLI) at GSI. The design is challenging due to the requirement of intense beams in CW mode up to a mass-to-charge ratio of 6, while covering a broad output energy range from 3.5 to 7.3MeV/u with minimum energy spread. In 2017 the first superconducting section of the linac has been successfully commissioned and extensively tested with beam at GSI. In the light of experience gained in this research so far, the beam dynamics layout for the entire linac has recently been updated and optimized with particular emphasis on realistic assumptions of cavity gap and drift lengths as well as gap voltage distributions for CH3-CH11.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012075
Open AccessAdvanced Beam Dynamics Design for the Superconducting Heavy Ion Accelerator HELIAC
The standalone superconducting (SC) continuous wave (CW) heavy ion linac HELIAC (HElmholtz LInear ACcelerator) is a common project of GSI and HIM under key support of IAP Frankfurt and in collaboration with Moscow Engineering Physics Institute (MEPhI) and Moscow Institute for Theoretical and Experimental Physics (KI-ITEP). It is intended for future experiments with heavy ions near the Coulomb barrier within super-heavy element (SHE) research and aims at developing a linac with multiple CH cavities as key components downstream the High Charge State Injector (HLI) at GSI. The design is challenging due to the requirement of intense beams in CW mode up to a mass-to-charge ratio of 6, while covering a broad output energy range from 3.5 to 7.3MeV/u with minimum energy spread. In 2017 the first superconducting section of the linac has been successfully commissioned and extensively tested with beam at GSI. In the light of experience gained in this research so far, the beam dynamics layout for the entire linac has recently been updated and optimized with particular emphasis on realistic assumptions of cavity gap and drift lengths as well as gap voltage distributions for CH3-CH11.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012096
Charge stripping at high energy heavy ion Linacs
For each heavy-ion accelerator facility charge stripping is a key technology – the stripping charge state, its efficiency to produce ions in the selected charge state, and the beam quality after stripping substantially determine the entire accelerator performance. Modern heavy ion accelerator facilities such as the future Facility for Antiproton and Ion Research (FAIR) at GSI, Darmstadt, Germany provide for high-intensity heavy-ion beams beyond 200 MeV/u. Heavy ions generated in an ion source at comparatively low charge states are pre-accelerated in a Linac to a few MeV/u, after charge stripping the average charge state is increased and one (or several) ion charge states are selected for further acceleration. This enables more efficient acceleration up to the final beam energy, compared to acceleration of ions with a low charge state. C-foil stripping allows for highest mean charge state and best stripping efficiency into the desired charge state. Therefore minimum acceleration voltage could be expected utilizing C-foil stripping. Due to the high power deposited by the ions in the stripping media and radiation damages if solids are used, self-recovering stripper media must be used in any case. First layout scenarios for a 200 MeV/u heavy ion Linac considering efficient heavy ion stripping will be presented.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012096
Open AccessCharge stripping at high energy heavy ion Linacs
For each heavy-ion accelerator facility charge stripping is a key technology – the stripping charge state, its efficiency to produce ions in the selected charge state, and the beam quality after stripping substantially determine the entire accelerator performance. Modern heavy ion accelerator facilities such as the future Facility for Antiproton and Ion Research (FAIR) at GSI, Darmstadt, Germany provide for high-intensity heavy-ion beams beyond 200 MeV/u. Heavy ions generated in an ion source at comparatively low charge states are pre-accelerated in a Linac to a few MeV/u, after charge stripping the average charge state is increased and one (or several) ion charge states are selected for further acceleration. This enables more efficient acceleration up to the final beam energy, compared to acceleration of ions with a low charge state. C-foil stripping allows for highest mean charge state and best stripping efficiency into the desired charge state. Therefore minimum acceleration voltage could be expected utilizing C-foil stripping. Due to the high power deposited by the ions in the stripping media and radiation damages if solids are used, self-recovering stripper media must be used in any case. First layout scenarios for a 200 MeV/u heavy ion Linac considering efficient heavy ion stripping will be presented.
- Open Access
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012073
Reconstruction of the longitudinal phase portrait for the SC CW heavy ion HELIAC at GSI
At the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany, the HElmholtz LInear Accelerator (HELIAC) is currently under construction. The HELIAC comprises superconducting multigap Crossbar H-mode (SC CH) cavities. The input beam is delivered by an already existing High Charge Injector (HLI). For the further development of the accelerator a detailed knowledge of the input beam parameters to the SC section is necessary. A method for beam reconstruction is incorporated, which provides for longitudinal beam characteristics using measurements with a beam shape monitor and a particle simulation code. This finalizes the investigations on 6D beam parameters, following previous measurements in transversal phase space. The reconstruction of the longitudinal phase portrait is presented.
- 1 November 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1350 (1) , 012073
Open AccessReconstruction of the longitudinal phase portrait for the SC CW heavy ion HELIAC at GSI
At the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany, the HElmholtz LInear Accelerator (HELIAC) is currently under construction. The HELIAC comprises superconducting multigap Crossbar H-mode (SC CH) cavities. The input beam is delivered by an already existing High Charge Injector (HLI). For the further development of the accelerator a detailed knowledge of the input beam parameters to the SC section is necessary. A method for beam reconstruction is incorporated, which provides for longitudinal beam characteristics using measurements with a beam shape monitor and a particle simulation code. This finalizes the investigations on 6D beam parameters, following previous measurements in transversal phase space. The reconstruction of the longitudinal phase portrait is presented.
- Open Access
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1067 (5) , 052007
Superconducting CH-cavity heavy ion beam testing at GSI
Recently the first section of a standalone superconducting (sc) continuous wave (cw) heavy ion Linac as a demonstration of the capability of 217 MHz multi gap Crossbar H-mode structures (CH) has been commissioned and extensively tested with beam from the GSI High Charge State Injector (HLI). The demonstrator set up reached acceleration of heavy ions up to the design beam energy and beyond. The required acceleration gain of 0.5 MeV/u was achieved with heavy ion beams even above the design mass to charge ratio at maximum available beam intensity and full beam transmission. This contribution presents systematic beam measurements with varying RF-amplitudes and -phases of the CH-cavity, as well as versatile phase space measurements for heavy ion beams with different mass to charge ratio. The worldwide first and successful beam test with a superconducting multi gap CH-cavity is a milestone of the R&D work of Helmholtz Institute Mainz (HIM) and GSI in collaboration with Goethe University Frankfurt (GUF) in preparation of the sc cw heavy ion Linac project and other cw-ion beam applications.
- 1 September 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1067 (5) , 052007
Open AccessSuperconducting CH-cavity heavy ion beam testing at GSI
Recently the first section of a standalone superconducting (sc) continuous wave (cw) heavy ion Linac as a demonstration of the capability of 217 MHz multi gap Crossbar H-mode structures (CH) has been commissioned and extensively tested with beam from the GSI High Charge State Injector (HLI). The demonstrator set up reached acceleration of heavy ions up to the design beam energy and beyond. The required acceleration gain of 0.5 MeV/u was achieved with heavy ion beams even above the design mass to charge ratio at maximum available beam intensity and full beam transmission. This contribution presents systematic beam measurements with varying RF-amplitudes and -phases of the CH-cavity, as well as versatile phase space measurements for heavy ion beams with different mass to charge ratio. The worldwide first and successful beam test with a superconducting multi gap CH-cavity is a milestone of the R&D work of Helmholtz Institute Mainz (HIM) and GSI in collaboration with Goethe University Frankfurt (GUF) in preparation of the sc cw heavy ion Linac project and other cw-ion beam applications.