Kanthan Theivendran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kanthan Theivendran has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Laura Jane Leslie
Aston Institute of Materials Research, Aston University, Birmingham, UK
3 shared publications Aleksi Reito
Tampere University Hospital (TAUH), Tampere, Finland
2 shared publicationsClary J. Foote
McMaster University, Hamilton, Canada
2 shared publicationsFaizan Arshad
Sandwell & West Birmingham Hospitals NHS Trust, Birmingham, UK
2 shared publicationsKerry Dwan
University of Liverpool; Liverpool Reviews and Implementation Group; Sherrington Building Ashton Street Liverpool UK L69 3GE
2 shared publications- Maiar Elhariry
Sandwell General Hospital, Sandwell and West NHS Trust, Birmingham, United Kingdom
2 shared publications
Latest Publications
- Open Access
- 1 October 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (4) , e003606
Implementation of Digital Consent at Sandwell and West Birmingham NHS Trust: A Quality Improvement Project
Digital consent systems provide a modern alternative to traditional paper-based methods, improving legibility, documentation accuracy, compliance with National Health Service (NHS) medicolegal standards and patient understanding. This quality improvement project evaluated the implementation of a digital consent system in the Trauma and Orthopaedics department at Sandwell and West Birmingham NHS Trust, comparing paper-based consent with the digital system. Baseline data were collected retrospectively from July to August 2024 and compared with prospective data following implementation from August to October 2024, using quantitative measures of documentation quality and qualitative feedback from healthcare professionals (n=24) and patient (n=619) surveys. An iterative Plan-Do-Study-Act cycle approach was used to refine the process. Following implementation, legibility improved from 42–48% to 100% across all digital consents, and documentation of alternative treatment options increased substantially from 5% to 95% in trauma cases and from 0% to 98% in elective cases. Risks and benefits were documented in 100% of digital consents. Patient and clinician surveys demonstrated high satisfaction, with a mean System Usability Score of 77.5, comparable to high-performing consumer technology platforms. Identified barriers included accessibility issues for less digitally literate patients and technical challenges such as digital signing on smaller devices. The transition to digital consent resulted in a cumulative cost saving of £2552.90 over the first 7 months. The introduction of digital consent significantly improved documentation quality, patient and clinician satisfaction and generated measurable cost savings. Ongoing challenges relating to accessibility and technical usability require targeted interventions. This project demonstrates the potential for digital consent systems to support efficient, sustainable and patient-centred care, with opportunities for broader adoption across NHS specialties.
- 1 October 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (4) , e003606
Open AccessImplementation of Digital Consent at Sandwell and West Birmingham NHS Trust: A Quality Improvement Project
Digital consent systems provide a modern alternative to traditional paper-based methods, improving legibility, documentation accuracy, compliance with National Health Service (NHS) medicolegal standards and patient understanding. This quality improvement project evaluated the implementation of a digital consent system in the Trauma and Orthopaedics department at Sandwell and West Birmingham NHS Trust, comparing paper-based consent with the digital system. Baseline data were collected retrospectively from July to August 2024 and compared with prospective data following implementation from August to October 2024, using quantitative measures of documentation quality and qualitative feedback from healthcare professionals (n=24) and patient (n=619) surveys. An iterative Plan-Do-Study-Act cycle approach was used to refine the process. Following implementation, legibility improved from 42–48% to 100% across all digital consents, and documentation of alternative treatment options increased substantially from 5% to 95% in trauma cases and from 0% to 98% in elective cases. Risks and benefits were documented in 100% of digital consents. Patient and clinician surveys demonstrated high satisfaction, with a mean System Usability Score of 77.5, comparable to high-performing consumer technology platforms. Identified barriers included accessibility issues for less digitally literate patients and technical challenges such as digital signing on smaller devices. The transition to digital consent resulted in a cumulative cost saving of £2552.90 over the first 7 months. The introduction of digital consent significantly improved documentation quality, patient and clinician satisfaction and generated measurable cost savings. Ongoing challenges relating to accessibility and technical usability require targeted interventions. This project demonstrates the potential for digital consent systems to support efficient, sustainable and patient-centred care, with opportunities for broader adoption across NHS specialties.
- Open Access
- 1 July 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (3) , e003450
Improving the detection and documentation of suspected cauda equina syndrome: a quality improvement project
Background: Cauda equina syndrome (CES) is a rare but critical neurological emergency. Prompt diagnosis and accurate documentation are essential to avoid permanent neurological impairment. This quality improvement project aimed to improve the accuracy and completeness of neurological examination documentation for patients presenting with suspected CES. Methods: Using three Plan-Do-Study-Act (PDSA) cycles, a digitally prompted documentation tool ‘#CES’ was developed and implemented in the electronic patient record system. The tool was designed in alignment with the 2019 GIRFT Spine Report and 2023 GIRFT National CES Pathway. It included red flag symptoms and neurological assessment criteria from the ASIA classification. A teaching session on its use was delivered in January before the second data collection period (19 September 2024–20 October 2024), and it was later incorporated into resident doctor induction in December before the third data collection period (5 January 2025–5 February 2025). Results: In the initial cycle (May–August 2024), documentation was inconsistent, particularly for sensory (0%) and reflex (4.9%) examination. Following implementation and a teaching session (September 2024), documentation improved in the second cycle (September–October 2024): sensation (81.3%), reflexes (57.1%), though tone and motor documentation declined. In the third cycle (January–February 2025), full template use rose to 80% (from 25%) and documentation further improved: sensation (94.1%), motor (64.7%), reflexes (64.7%), tone (64.7%), vascular (58.8%). Conclusions: A CES-specific, digitally prompted template significantly improved documentation quality. Integration of GIRFT red flags, clinician codesign and repeated education enhanced uptake and accuracy. Further PDSA cycles will focus on sustainability, time-to-diagnosis metrics and addressing clinician workload concerns.
- 1 July 2025
- Published by BMJ in BMJ Open Quality
- Vol. 14 (3) , e003450
Open AccessImproving the detection and documentation of suspected cauda equina syndrome: a quality improvement project
Background: Cauda equina syndrome (CES) is a rare but critical neurological emergency. Prompt diagnosis and accurate documentation are essential to avoid permanent neurological impairment. This quality improvement project aimed to improve the accuracy and completeness of neurological examination documentation for patients presenting with suspected CES. Methods: Using three Plan-Do-Study-Act (PDSA) cycles, a digitally prompted documentation tool ‘#CES’ was developed and implemented in the electronic patient record system. The tool was designed in alignment with the 2019 GIRFT Spine Report and 2023 GIRFT National CES Pathway. It included red flag symptoms and neurological assessment criteria from the ASIA classification. A teaching session on its use was delivered in January before the second data collection period (19 September 2024–20 October 2024), and it was later incorporated into resident doctor induction in December before the third data collection period (5 January 2025–5 February 2025). Results: In the initial cycle (May–August 2024), documentation was inconsistent, particularly for sensory (0%) and reflex (4.9%) examination. Following implementation and a teaching session (September 2024), documentation improved in the second cycle (September–October 2024): sensation (81.3%), reflexes (57.1%), though tone and motor documentation declined. In the third cycle (January–February 2025), full template use rose to 80% (from 25%) and documentation further improved: sensation (94.1%), motor (64.7%), reflexes (64.7%), tone (64.7%), vascular (58.8%). Conclusions: A CES-specific, digitally prompted template significantly improved documentation quality. Integration of GIRFT red flags, clinician codesign and repeated education enhanced uptake and accuracy. Further PDSA cycles will focus on sustainability, time-to-diagnosis metrics and addressing clinician workload concerns.
- Open Access
Artificial intelligence (AI) for paediatric fracture detection: a multireader multicase (MRMC) study protocol
Introduction Paediatric fractures are common but can be easily missed on radiography leading to potentially serious implications including long-term pain, disability and missed opportunities for safeguarding in cases of inflicted injury. Artificial intelligence (AI) tools to assist fracture detection in adult patients exist, although their efficacy in children is less well known. This study aims to evaluate whether a commercially available AI tool (certified for paediatric use) improves healthcare professionals (HCPs) detection of fractures, and how this may impact patient care in a retrospective simulated study design. Methods and analysis Using a multicentric dataset of 500 paediatric radiographs across four body parts, the diagnostic performance of HCPs will be evaluated across two stages—first without, followed by with the assistance of an AI tool (BoneView, Gleamer) after an interval 4-week washout period. The dataset will contain a mixture of normal and abnormal cases. HCPs will be recruited across radiology, orthopaedics and emergency medicine. We will aim for 40 readers, with ~14 in each subspecialty, half being experienced consultants. For each radiograph HCPs will evaluate presence of a fracture, their confidence level and a suitable simulated management plan. Diagnostic accuracy will be judged against a consensus interpretation by an expert panel of two paediatric radiologists (ground truth). Multilevel logistic modelling techniques will analyse and report diagnostic accuracy outcome measures for fracture detection. Descriptive statistics will evaluate changes in simulated patient management. Ethics and dissemination This study was granted approval by National Health Service Health Research Authority and Health and Care Research Wales (REC Reference: 22/PR/0334). IRAS Project ID is 274 278. Funding has been provided by the National Institute for Heath and Care Research (NIHR) (Grant ID: NIHR-301322). Findings from this study will be disseminated through peer-reviewed publications, conferences and non-peer-reviewed media and social media outlets. Trial registration number ISRCTN12921105.
Open AccessArtificial intelligence (AI) for paediatric fracture detection: a multireader multicase (MRMC) study protocol
Introduction Paediatric fractures are common but can be easily missed on radiography leading to potentially serious implications including long-term pain, disability and missed opportunities for safeguarding in cases of inflicted injury. Artificial intelligence (AI) tools to assist fracture detection in adult patients exist, although their efficacy in children is less well known. This study aims to evaluate whether a commercially available AI tool (certified for paediatric use) improves healthcare professionals (HCPs) detection of fractures, and how this may impact patient care in a retrospective simulated study design. Methods and analysis Using a multicentric dataset of 500 paediatric radiographs across four body parts, the diagnostic performance of HCPs will be evaluated across two stages—first without, followed by with the assistance of an AI tool (BoneView, Gleamer) after an interval 4-week washout period. The dataset will contain a mixture of normal and abnormal cases. HCPs will be recruited across radiology, orthopaedics and emergency medicine. We will aim for 40 readers, with ~14 in each subspecialty, half being experienced consultants. For each radiograph HCPs will evaluate presence of a fracture, their confidence level and a suitable simulated management plan. Diagnostic accuracy will be judged against a consensus interpretation by an expert panel of two paediatric radiologists (ground truth). Multilevel logistic modelling techniques will analyse and report diagnostic accuracy outcome measures for fracture detection. Descriptive statistics will evaluate changes in simulated patient management. Ethics and dissemination This study was granted approval by National Health Service Health Research Authority and Health and Care Research Wales (REC Reference: 22/PR/0334). IRAS Project ID is 274 278. Funding has been provided by the National Institute for Heath and Care Research (NIHR) (Grant ID: NIHR-301322). Findings from this study will be disseminated through peer-reviewed publications, conferences and non-peer-reviewed media and social media outlets. Trial registration number ISRCTN12921105.
- Open Access
- 2 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33263
Floating Forearm Injury: Monteggia Variant Fracture With an Ipsilateral Distal Radius and Ulna Fracture
Monteggia variant fracture is a Monteggia fracture (proximal third ulna fracture with radial head dislocation) with an associated radial head fracture, coronoid fracture or complex pattern of injury. We report a rare case of an 80-year-old lady with a right Monteggia variant fracture with an ipsilateral distal radius and ulna fracture leading to a floating forearm injury. To our knowledge, this is the first case report to describe this injury pattern. We describe the multidisciplinary team approach and detailed surgical technique in managing this rare and complex injury.
- 2 January 2023
- Published by Springer Nature in Cureus
- Vol. 15 (1) , e33263
Open AccessFloating Forearm Injury: Monteggia Variant Fracture With an Ipsilateral Distal Radius and Ulna Fracture
Monteggia variant fracture is a Monteggia fracture (proximal third ulna fracture with radial head dislocation) with an associated radial head fracture, coronoid fracture or complex pattern of injury. We report a rare case of an 80-year-old lady with a right Monteggia variant fracture with an ipsilateral distal radius and ulna fracture leading to a floating forearm injury. To our knowledge, this is the first case report to describe this injury pattern. We describe the multidisciplinary team approach and detailed surgical technique in managing this rare and complex injury.
- Open Access
- 3 August 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (9) , 1253-1272
Experimental testing of fracture fixation plates: A review
Metal and its alloys have been predominantly used in fracture fixation for centuries, but new materials such as composites and polymers have begun to see clinical use for fracture fixation during the past couple of decades. Along with the emerging of new materials, tribological issues, especially debris, have become a growing concern for fracture fixation plates. This article for the first time systematically reviews the most recent biomechanical research, with a focus on experimental testing, of those plates within ScienceDirect and PubMed databases. Based on the search criteria, a total of 5449 papers were retrieved, which were then further filtered to exclude nonrelevant, duplicate or non-accessible full article papers. In the end, a total of 83 papers were reviewed. In experimental testing plates, screws and simulated bones or cadaver bones are employed to build a fixation construct in order to test the strength and stability of different plate and screw configurations. The test set-up conditions and conclusions are well documented and summarised here, including fracture gap size, types of bones deployed, as well as the applied load, test speed and test ending criteria. However, research on long term plate usage was very limited. It is also discovered that there is very limited experimental research around the tribological behaviour particularly on the debris’ generation, collection and characterisation. In addition, there is no identified standard studying debris of fracture fixation plate. Therefore, the authors suggested the generation of a suite of tribological testing standards on fracture fixation plate and screws in the aim to answer key questions around the debris from fracture fixation plate of new materials or new design and ultimately to provide an insight on how to reduce the risks of debris-related osteolysis, inflammation and aseptic loosening.
- 3 August 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (9) , 1253-1272
Open AccessExperimental testing of fracture fixation plates: A review
Metal and its alloys have been predominantly used in fracture fixation for centuries, but new materials such as composites and polymers have begun to see clinical use for fracture fixation during the past couple of decades. Along with the emerging of new materials, tribological issues, especially debris, have become a growing concern for fracture fixation plates. This article for the first time systematically reviews the most recent biomechanical research, with a focus on experimental testing, of those plates within ScienceDirect and PubMed databases. Based on the search criteria, a total of 5449 papers were retrieved, which were then further filtered to exclude nonrelevant, duplicate or non-accessible full article papers. In the end, a total of 83 papers were reviewed. In experimental testing plates, screws and simulated bones or cadaver bones are employed to build a fixation construct in order to test the strength and stability of different plate and screw configurations. The test set-up conditions and conclusions are well documented and summarised here, including fracture gap size, types of bones deployed, as well as the applied load, test speed and test ending criteria. However, research on long term plate usage was very limited. It is also discovered that there is very limited experimental research around the tribological behaviour particularly on the debris’ generation, collection and characterisation. In addition, there is no identified standard studying debris of fracture fixation plate. Therefore, the authors suggested the generation of a suite of tribological testing standards on fracture fixation plate and screws in the aim to answer key questions around the debris from fracture fixation plate of new materials or new design and ultimately to provide an insight on how to reduce the risks of debris-related osteolysis, inflammation and aseptic loosening.
- 16 July 2022
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 32, 101952
Digital templating in hip hemiarthroplasty: Is it possible to accurately predict femoral head size from magnification alone?
- 16 July 2022
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 32, 101952
Digital templating in hip hemiarthroplasty: Is it possible to accurately predict femoral head size from magnification alone?
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 7208-7218
Development of a Multi-Sensor Array for Non-Radiographic Micromotion Detection of Joint Prostheses
Total joint arthroplasty procedures are increasing year on year, however, the complications that are associated with the joint arthroplasty remain. Using total elbow arthroplasty as a case study due to the high loosening rates, a technique has been further developed to accurately monitor the position of the prosthesis. Micromotion detection of endoprosthetic elbow prostheses is vital for longevity along with timely, adequate treatment. At present, radiographs are used to monitor the prostheses position at the macro-scale which lacks in early detection of prostheses loosening. In this work, a multiple magnetic sensor (multi-sensor) configuration was designed that can detect real-time micromotion of the elbow prosthesis without the use of radiographs. The proposed approach can detect 0.15 mm micromotion with an average error below 0.05 mm linearly. This method also eliminated the tilting effect and increase the sensitivity of the system to 18 mm along with improving the signal to noise ratio and reducing RMS error compared to a single sensor configuration.
- 18 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 7208-7218
Development of a Multi-Sensor Array for Non-Radiographic Micromotion Detection of Joint Prostheses
Total joint arthroplasty procedures are increasing year on year, however, the complications that are associated with the joint arthroplasty remain. Using total elbow arthroplasty as a case study due to the high loosening rates, a technique has been further developed to accurately monitor the position of the prosthesis. Micromotion detection of endoprosthetic elbow prostheses is vital for longevity along with timely, adequate treatment. At present, radiographs are used to monitor the prostheses position at the macro-scale which lacks in early detection of prostheses loosening. In this work, a multiple magnetic sensor (multi-sensor) configuration was designed that can detect real-time micromotion of the elbow prosthesis without the use of radiographs. The proposed approach can detect 0.15 mm micromotion with an average error below 0.05 mm linearly. This method also eliminated the tilting effect and increase the sensitivity of the system to 18 mm along with improving the signal to noise ratio and reducing RMS error compared to a single sensor configuration.
- 30 January 2022
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 26, 101779
Response to letter: Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: A systematic review
- 30 January 2022
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 26, 101779
Response to letter: Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: A systematic review
- 6 August 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (8) , e242436
Mucinous adenocarcinoma of the lung presenting as pathological humeral fracture: a case report and novel surgical treatment
We present a 73-year-old woman who presented with a pathological fracture of her right humerus. Further imaging and biopsy indicated a mucinous adenocarcinoma of the lung as the primary neoplasm. This represents the first published case of a mucinous adenocarcinoma of the lung presenting as a metastatic lesion of the humerus. Operative management of pathological fractures of the humerus has typically included either intramedullary nailing or the use of single-plating or double-plating techniques. The authors describe a novel technique using both intramedullary fixation augmented with a locking plate, steel cables and bone cement, with good outcome.
- 6 August 2021
- Published by BMJ in BMJ Case Reports
- Vol. 14 (8) , e242436
Mucinous adenocarcinoma of the lung presenting as pathological humeral fracture: a case report and novel surgical treatment
We present a 73-year-old woman who presented with a pathological fracture of her right humerus. Further imaging and biopsy indicated a mucinous adenocarcinoma of the lung as the primary neoplasm. This represents the first published case of a mucinous adenocarcinoma of the lung presenting as a metastatic lesion of the humerus. Operative management of pathological fractures of the humerus has typically included either intramedullary nailing or the use of single-plating or double-plating techniques. The authors describe a novel technique using both intramedullary fixation augmented with a locking plate, steel cables and bone cement, with good outcome.