Dhritiman Chakrabarti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dhritiman Chakrabarti has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alok Mohan Uppar
Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bengaluru, Karnataka, India
1 shared publication - Andiperumal Raj Prabhuraj
Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bangalore, India
1 shared publication - Bhushan Diwakar Thombre
Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bangalore, India
1 shared publication - Dhaval Shukla
Department of Neurosurgery, National Institute of Mental Health and Neurosciences (NIMHANS), Bangalore, India
1 shared publication - Hima Pendharkar
Neuroimaging and Interventional Radiology, National Institute of Mental Health & Neurosciences, Bengaluru, India
1 shared publication - Kannepalli Narasingha Rao
Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bengaluru, Karnataka, India
1 shared publication
Latest Publications
- 1 January 2021
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 200, 106369
Surgical outcomes of Supra- Infra Tentorial Extradural Hematoma (SIEDH): A retrospective study from a single institution
- 1 January 2021
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 200, 106369
Surgical outcomes of Supra- Infra Tentorial Extradural Hematoma (SIEDH): A retrospective study from a single institution
- 7 May 2015
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 30 (2) , 203-206
Endovascular coil detachment causing EMG artefact in BIS: a mechanistic exploration
Deployment of endovascular coils used in interventional neuroradiology commonly involves electrolytic detachment of the coil from the pusher catheter. This report describes a case of artefactual increase in electromyography (EMG) values of bispectral index (BIS) monitor during coil detachment. An explanation of this event is provided connecting mechanism of coil detachment and derivation of EMG values in a BIS monitor. While rising EMG values are thought to arise from frontalis contraction, they may as well be an unrecognized electrical artefact, especially in context of undistorted electroencephalography waveform.
- 7 May 2015
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 30 (2) , 203-206
Endovascular coil detachment causing EMG artefact in BIS: a mechanistic exploration
Deployment of endovascular coils used in interventional neuroradiology commonly involves electrolytic detachment of the coil from the pusher catheter. This report describes a case of artefactual increase in electromyography (EMG) values of bispectral index (BIS) monitor during coil detachment. An explanation of this event is provided connecting mechanism of coil detachment and derivation of EMG values in a BIS monitor. While rising EMG values are thought to arise from frontalis contraction, they may as well be an unrecognized electrical artefact, especially in context of undistorted electroencephalography waveform.
- 22 April 2015
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 30 (1) , 119-122
ECG contamination of EEG signals: effect on entropy
Entropy™ is a proprietary algorithm which uses spectral entropy analysis of electroencephalographic (EEG) signals to produce indices which are used as a measure of depth of hypnosis. We describe a report of electrocardiographic (ECG) contamination of EEG signals leading to fluctuating erroneous Entropy values. An explanation is provided for mechanism behind this observation by describing the spread of ECG signals in head and neck and its influence on EEG/Entropy by correlating the observation with the published Entropy algorithm. While the Entropy algorithm has been well conceived, there are still instances in which it can produce erroneous values. Such erroneous values and their cause may be identified by close scrutiny of the EEG waveform if Entropy values seem out of sync with that expected at given anaesthetic levels.
- 22 April 2015
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 30 (1) , 119-122
ECG contamination of EEG signals: effect on entropy
Entropy™ is a proprietary algorithm which uses spectral entropy analysis of electroencephalographic (EEG) signals to produce indices which are used as a measure of depth of hypnosis. We describe a report of electrocardiographic (ECG) contamination of EEG signals leading to fluctuating erroneous Entropy values. An explanation is provided for mechanism behind this observation by describing the spread of ECG signals in head and neck and its influence on EEG/Entropy by correlating the observation with the published Entropy algorithm. While the Entropy algorithm has been well conceived, there are still instances in which it can produce erroneous values. Such erroneous values and their cause may be identified by close scrutiny of the EEG waveform if Entropy values seem out of sync with that expected at given anaesthetic levels.