Atilla Bıyıkoğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Atilla Bıyıkoğlu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Anıl Kemal AKBULUT
2 shared publications- Korhan Ökten
Amasya Üniversitesi
2 shared publications Murat Erbaş
2 shared publications- Ali Alperen Özkan
Gazi University
1 shared publication - Bülent Nafi Örnek
Department of Computer Engineering, Amasya University, Amasya, Turkey
1 shared publication - Dilara Coşkun
Department of Mechanical Engineering, Engineering Faculty, Gazi University, Ankara, Türkiye
1 shared publication
Latest Publications
- Open Access
- 22 October 2026
- Published by Elsevier in SSRN Electronic Journal
Exergy-based assessment of cascaded phase-change thermal energy storage for solar ORC applications: Effect of stage number
Cascaded phase change materials (PCMs) can reduce temperature mismatch between a heat-transfer fluid (HTF) and latent-heat thermal energy storage, but increasing the number of stages also increases equipment count and cost. This study revises an NTU-based MATLAB model of a solar-coupled cascaded PCM storage system intended to supply an organic Rankine cycle (ORC), with particular attention to thermodynamic consistency. The original discharge tables paired the HTF temperature trajectory with the wrong PCM-stage order, which can imply heat transfer from a colder PCM to a hotter fluid. The discharge model was therefore re-derived using reverse thermal ordering and a conventional second-law efficiency definition. For the stated baseline conditions ( T0=298.15 K, hot-side inlet 1200 K, cold-side inlet 300 K, NTU=1 ), the reconstructed useful exergy gain of the discharge HTF increases from 121.4 to 185.8 kW_ex as the stage count increases from 3 to 15. The direct storage exergy-recovery ratio increases from 0.2538 to 0.3800; the 10-stage case reaches 178.2 kW_ex and 0.3647, corresponding to 95.9% and 96.0% of the 15-stage values while using 68.0% of its estimated investment. Marginal thermodynamic gains become small beyond approximately 8–10 stages. After correction, the simple one-year investment-to-useful-exergy ratio is minimized at three stages, showing that the available cost data do not support a unique 10-stage economic optimum. The reported ORC calculation is retained only as an illustrative coupling case because its discharge table does not close the energy balance. Transient validation, stage-specific PCM selection, heat-loss modeling, and levelized economics are required before plant-scale optimization.
- 22 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExergy-based assessment of cascaded phase-change thermal energy storage for solar ORC applications: Effect of stage number
Cascaded phase change materials (PCMs) can reduce temperature mismatch between a heat-transfer fluid (HTF) and latent-heat thermal energy storage, but increasing the number of stages also increases equipment count and cost. This study revises an NTU-based MATLAB model of a solar-coupled cascaded PCM storage system intended to supply an organic Rankine cycle (ORC), with particular attention to thermodynamic consistency. The original discharge tables paired the HTF temperature trajectory with the wrong PCM-stage order, which can imply heat transfer from a colder PCM to a hotter fluid. The discharge model was therefore re-derived using reverse thermal ordering and a conventional second-law efficiency definition. For the stated baseline conditions ( T0=298.15 K, hot-side inlet 1200 K, cold-side inlet 300 K, NTU=1 ), the reconstructed useful exergy gain of the discharge HTF increases from 121.4 to 185.8 kW_ex as the stage count increases from 3 to 15. The direct storage exergy-recovery ratio increases from 0.2538 to 0.3800; the 10-stage case reaches 178.2 kW_ex and 0.3647, corresponding to 95.9% and 96.0% of the 15-stage values while using 68.0% of its estimated investment. Marginal thermodynamic gains become small beyond approximately 8–10 stages. After correction, the simple one-year investment-to-useful-exergy ratio is minimized at three stages, showing that the available cost data do not support a unique 10-stage economic optimum. The reported ORC calculation is retained only as an illustrative coupling case because its discharge table does not close the energy balance. Transient validation, stage-specific PCM selection, heat-loss modeling, and levelized economics are required before plant-scale optimization.
- Open Access
- 21 October 2026
- Published by Elsevier in SSRN Electronic Journal
Effect of phase change material stage count on exergy performance and cost screening of cascaded latent heat thermal energy storage
Latent heat thermal energy storage using cascaded phase change materials can reduce finite-temperature heat-transfer irreversibility, but the benefit of adding stages must be balanced against diminishing thermodynamic returns and additional hardware cost. This study develops a number-of-transfer-units (NTU)-based exergy model for an n-stage cascaded storage system and implements it in MATLAB for charging by a hot heat-transfer fluid and discharging to water. Detailed 3-stage and 10-stage configurations are compared under common boundary conditions, while 3, 5, 8, 10, 12, 13, and 15 stages are screened using an illustrative capital-cost dataset. Under the stated model conditions, charging, discharging, and overall exergy efficiencies increase from 0.4871, 0.6238, and 0.3039 for three stages to 0.6352, 0.9060, and 0.5755 for ten stages. The useful-exergy rate continues to rise with stage count, but its marginal gain decreases sharply. The capital-to-annual-exergy screening ratio is lowest at five stages, whereas the 10-stage case delivers 92.5% of the 15-stage useful-exergy rate at 68.0% of its stated capital cost. The results show that PCM stage count, melting-temperature distribution, and heat-transfer conductance should be selected jointly rather than by maximizing stage count alone.
- 21 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEffect of phase change material stage count on exergy performance and cost screening of cascaded latent heat thermal energy storage
Latent heat thermal energy storage using cascaded phase change materials can reduce finite-temperature heat-transfer irreversibility, but the benefit of adding stages must be balanced against diminishing thermodynamic returns and additional hardware cost. This study develops a number-of-transfer-units (NTU)-based exergy model for an n-stage cascaded storage system and implements it in MATLAB for charging by a hot heat-transfer fluid and discharging to water. Detailed 3-stage and 10-stage configurations are compared under common boundary conditions, while 3, 5, 8, 10, 12, 13, and 15 stages are screened using an illustrative capital-cost dataset. Under the stated model conditions, charging, discharging, and overall exergy efficiencies increase from 0.4871, 0.6238, and 0.3039 for three stages to 0.6352, 0.9060, and 0.5755 for ten stages. The useful-exergy rate continues to rise with stage count, but its marginal gain decreases sharply. The capital-to-annual-exergy screening ratio is lowest at five stages, whereas the 10-stage case delivers 92.5% of the 15-stage useful-exergy rate at 68.0% of its stated capital cost. The results show that PCM stage count, melting-temperature distribution, and heat-transfer conductance should be selected jointly rather than by maximizing stage count alone.
- 20 October 2026
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- No. Advanced O
Türkiye'nin bazı şehirleri için güneş ışınım ekserji potansiyeli
Güneş, sürdürülebilir enerji sistemleri için önemli bir yenilenebilir enerji kaynağıdır. Bu çalışmada, Türkiye’de seçilen illerin güneş ışınımı ekserjisi ve ekserji/enerji oranları Petela, Spanner ve Jeter modelleri kullanılarak hesaplanmıştır. Hesaplamalarda, Meteoroloji Genel Müdürlüğü’nden alınan ortalama güneş ışınımı şiddeti ve yıllık ortalama sıcaklık verileri kullanılmıştır. Sonuçlar, yıllık ortalama güneş ışınımı şiddetinin 11,076–17,513 MJ/m²·gün arasında değiştiğini göstermiştir. En yüksek güneş ışınımı ve ekserji değerleri Mersin’de elde edilmiştir. Mersin için Petela ve Spanner modelleri 16,371 MJ/m²·gün, Jeter modeli ise 16,657 MJ/m²·gün ekserji değeri vermiştir. Ekserji/enerji oranları sırasıyla 0,934842, 0,934840 ve 0,951130 olarak hesaplanmıştır. En düşük ekserji değerleri Rize’de elde edilmiş ve Petela ile Spanner modellerinde 10,363 MJ/m²·gün, Jeter modelinde ise 10,541 MJ/m²·gün olarak belirlenmiştir. Rize için ekserji/enerji oranları sırasıyla 0,935617, 0,935615 ve 0,951712’dir. Petela ve Spanner modelleri birbirine oldukça yakın sonuçlar verirken, Jeter modeli daha yüksek ekserji değerleri tahmin etmiştir. Bulgular, güneş ekserji potansiyelinin bölgesel ışınım ve sıcaklık koşullarına bağlı olduğunu ve güney kıyı bölgelerinin daha yüksek potansiyele sahip olduğunu göstermektedir.
- 20 October 2026
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- No. Advanced O
Türkiye'nin bazı şehirleri için güneş ışınım ekserji potansiyeli
Güneş, sürdürülebilir enerji sistemleri için önemli bir yenilenebilir enerji kaynağıdır. Bu çalışmada, Türkiye’de seçilen illerin güneş ışınımı ekserjisi ve ekserji/enerji oranları Petela, Spanner ve Jeter modelleri kullanılarak hesaplanmıştır. Hesaplamalarda, Meteoroloji Genel Müdürlüğü’nden alınan ortalama güneş ışınımı şiddeti ve yıllık ortalama sıcaklık verileri kullanılmıştır. Sonuçlar, yıllık ortalama güneş ışınımı şiddetinin 11,076–17,513 MJ/m²·gün arasında değiştiğini göstermiştir. En yüksek güneş ışınımı ve ekserji değerleri Mersin’de elde edilmiştir. Mersin için Petela ve Spanner modelleri 16,371 MJ/m²·gün, Jeter modeli ise 16,657 MJ/m²·gün ekserji değeri vermiştir. Ekserji/enerji oranları sırasıyla 0,934842, 0,934840 ve 0,951130 olarak hesaplanmıştır. En düşük ekserji değerleri Rize’de elde edilmiş ve Petela ile Spanner modellerinde 10,363 MJ/m²·gün, Jeter modelinde ise 10,541 MJ/m²·gün olarak belirlenmiştir. Rize için ekserji/enerji oranları sırasıyla 0,935617, 0,935615 ve 0,951712’dir. Petela ve Spanner modelleri birbirine oldukça yakın sonuçlar verirken, Jeter modeli daha yüksek ekserji değerleri tahmin etmiştir. Bulgular, güneş ekserji potansiyelinin bölgesel ışınım ve sıcaklık koşullarına bağlı olduğunu ve güney kıyı bölgelerinin daha yüksek potansiyele sahip olduğunu göstermektedir.
- 2 December 2024
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 37 (1)
Development of an analytical model to investigate temperature distribution and melt geometry in the laser powder bed fusion process under different operating parameters
Laser powder bed fusion (L-PBF) fabricates components by melting layers of metal powder. Consequently, it has the potential to induce interparticle air gaps or generate unpredictable stresses. As such, understanding temperature distribution and predicting the melt pool based on process parameters are essential. While numerous numerical studies in the literature aim to determine these parameters, these numerical estimation methods often demand extensive computational time and powerful processors. This study introduces a new analytical model and a solution method, offering a significantly faster and more precise solution compared to numerical approaches. Furthermore, the developed model allows the identification of liquid and solid phase regions within the part during production, along with insights into the phase region changes over time. Eigenfunction expansion, separation of variables, and variable transformation methods were employed in the analytical solution of the model equations. Results obtained from this method have been validated by experimental studies available in the literature. By utilizing the derived solution function, the L-PBF process was parametrically investigated, revealing temperature distributions and melt pool geometries. The parametric study focused on the laser power, spot size, and powder layer thicknesses as variable parameters. The study determined that a 50 W increase in laser power raises the maximum melt pool temperature by an average of 800 K, and laser power has been identified as the most influential parameter affecting temperature distribution and melt pool geometry.
- 2 December 2024
- Published by Laser Institute of America in Journal of Laser Applications
- Vol. 37 (1)
Development of an analytical model to investigate temperature distribution and melt geometry in the laser powder bed fusion process under different operating parameters
Laser powder bed fusion (L-PBF) fabricates components by melting layers of metal powder. Consequently, it has the potential to induce interparticle air gaps or generate unpredictable stresses. As such, understanding temperature distribution and predicting the melt pool based on process parameters are essential. While numerous numerical studies in the literature aim to determine these parameters, these numerical estimation methods often demand extensive computational time and powerful processors. This study introduces a new analytical model and a solution method, offering a significantly faster and more precise solution compared to numerical approaches. Furthermore, the developed model allows the identification of liquid and solid phase regions within the part during production, along with insights into the phase region changes over time. Eigenfunction expansion, separation of variables, and variable transformation methods were employed in the analytical solution of the model equations. Results obtained from this method have been validated by experimental studies available in the literature. By utilizing the derived solution function, the L-PBF process was parametrically investigated, revealing temperature distributions and melt pool geometries. The parametric study focused on the laser power, spot size, and powder layer thicknesses as variable parameters. The study determined that a 50 W increase in laser power raises the maximum melt pool temperature by an average of 800 K, and laser power has been identified as the most influential parameter affecting temperature distribution and melt pool geometry.
- 24 August 2023
- Published by Springer Nature
- p. 91-100
Development of Viscous CFD Analysis Model Including Real Gas Effects for Nose Optimization at Hypersonic Speeds
- 24 August 2023
- Published by Springer Nature
- p. 91-100
Development of Viscous CFD Analysis Model Including Real Gas Effects for Nose Optimization at Hypersonic Speeds
- Open Access
- 6 December 2022
- Published by International Journal of Pioneering Technology and Engineering in International Journal of Pioneering Technology and Engineering
- Vol. 1 (02) , 89-94
Efficiency Analysis of Covid 19 Filtration with The Theoretical Approach Developed for Single Fiber Efficiency
It is necessary to understand the efficiency of the filters, which are the most important part of the ventilation systems, in order to hinder the spreading of the Covid-19 virus. In this article, a model was created using theoretical solutions developed for single fiber efficiency and with this created model, the previous theoretical data were confirmed. Then, the theoretical data in the model created with the experimental data were compared. Also, factors such as fiber diameter, particle diameter, or flow velocity affecting single fiber efficiency were changed and the effects of these parameters were investigated. As a result of this investigation, it was seen that, as the Peclet number increased, the single fiber efficiency decreased, and the efficiency of the single fiber increased when the particle diameter increased. Finally, when the solidity, which can be considered as the fiber density in the filter, increased, the single fiber efficiency increased along with it. When solidity was increased from 0.011 to 0.03, single fiber efficiency increases from 0.023 to 0.0269. That is, there was an increase of approximately 16.9 %.
- 6 December 2022
- Published by International Journal of Pioneering Technology and Engineering in International Journal of Pioneering Technology and Engineering
- Vol. 1 (02) , 89-94
Open AccessEfficiency Analysis of Covid 19 Filtration with The Theoretical Approach Developed for Single Fiber Efficiency
It is necessary to understand the efficiency of the filters, which are the most important part of the ventilation systems, in order to hinder the spreading of the Covid-19 virus. In this article, a model was created using theoretical solutions developed for single fiber efficiency and with this created model, the previous theoretical data were confirmed. Then, the theoretical data in the model created with the experimental data were compared. Also, factors such as fiber diameter, particle diameter, or flow velocity affecting single fiber efficiency were changed and the effects of these parameters were investigated. As a result of this investigation, it was seen that, as the Peclet number increased, the single fiber efficiency decreased, and the efficiency of the single fiber increased when the particle diameter increased. Finally, when the solidity, which can be considered as the fiber density in the filter, increased, the single fiber efficiency increased along with it. When solidity was increased from 0.011 to 0.03, single fiber efficiency increases from 0.023 to 0.0269. That is, there was an increase of approximately 16.9 %.
- Open Access
- 31 October 2020
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 40 (2) , 281-291
KONUT TİPİ BİNALARDA SOĞUTMA YÜKÜNÜN OPTİMUM YALITIM KALINLIĞINA ETKİSİ
Bu çalışmanın amacı, Türkiye’deki konut tipi binalar için soğutma yükü etkisi altında optimum yalıtım kalınlığının (U-değerlerini) ömür maliyet analizi yapılarak belirlenmesi ve elde edilen sonuçlara göre TS 825 “Binalarda Isı Yalıtım Kuralları” standardında soğutma yükünün de hesaplamalara katılması gereken Derece Gün (DG) bölgelerinin tespit edilmesidir. Alan/Hacim (A/V) oranı 0,40 m-1 olan 5 katlı bir apartman binası referans bina olarak alınmıştır. Binaların yıllık enerji ihtiyaçları, TS EN ISO 13790 standardına göre hesaplanmıştır. Toplam maliyeti temel alan ömür maliyet analizi 30 yıllık bir kullanım ömrü için yapılmıştır. Optimum yalıtım kalınlıkları iklim bölgelerine göre; cephe için 0 cm ile 4 cm, tavan için 0 cm ile 7,5 cm, taban için 0 ile 2,3 cm arasında hesaplanmıştır. Sonuç olarak, TS 825 standardında belirtilen DG1 ve DG2 bölgelerinde soğutma yükünün optimum yalıtım kalınlığı hesaplarına dahil edilmesi gerektiği belirlenmiştir. DG1 ve DG2 bölgelerine göre daha soğuk iklim şartlarının etkili olduğu DG3 ve DG4 bölgelerinde soğutma yükünün optimum yalıtım kalınlığını etkilemediği sonucuna varılmıştır.
- 31 October 2020
- Published by Turk Isi Bilimi Ve Teknigi Dernegi in Isı Bilimi ve Tekniği Dergisi
- Vol. 40 (2) , 281-291
Open AccessKONUT TİPİ BİNALARDA SOĞUTMA YÜKÜNÜN OPTİMUM YALITIM KALINLIĞINA ETKİSİ
Bu çalışmanın amacı, Türkiye’deki konut tipi binalar için soğutma yükü etkisi altında optimum yalıtım kalınlığının (U-değerlerini) ömür maliyet analizi yapılarak belirlenmesi ve elde edilen sonuçlara göre TS 825 “Binalarda Isı Yalıtım Kuralları” standardında soğutma yükünün de hesaplamalara katılması gereken Derece Gün (DG) bölgelerinin tespit edilmesidir. Alan/Hacim (A/V) oranı 0,40 m-1 olan 5 katlı bir apartman binası referans bina olarak alınmıştır. Binaların yıllık enerji ihtiyaçları, TS EN ISO 13790 standardına göre hesaplanmıştır. Toplam maliyeti temel alan ömür maliyet analizi 30 yıllık bir kullanım ömrü için yapılmıştır. Optimum yalıtım kalınlıkları iklim bölgelerine göre; cephe için 0 cm ile 4 cm, tavan için 0 cm ile 7,5 cm, taban için 0 ile 2,3 cm arasında hesaplanmıştır. Sonuç olarak, TS 825 standardında belirtilen DG1 ve DG2 bölgelerinde soğutma yükünün optimum yalıtım kalınlığı hesaplarına dahil edilmesi gerektiği belirlenmiştir. DG1 ve DG2 bölgelerine göre daha soğuk iklim şartlarının etkili olduğu DG3 ve DG4 bölgelerinde soğutma yükünün optimum yalıtım kalınlığını etkilemediği sonucuna varılmıştır.
- 16 June 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 27 (1) , 2-13
Determination of optimum insulation thickness by life cycle cost analysis for residential buildings in Turkey
The main objective of this study is to determine the optimum insulation thickness of residential buildings in Turkey, under the influence of cooling and heating loads by life cycle cost analysis (LCCA). 5-storey apartment building with an Area/Volume ratio (A/V) of 0.40 m−1 and 10-storey apartment building with an A/V ratio of 0.32 m−1 are taken as reference buildings. The annual energy needs are calculated according to TS 825 standard for heating and TS EN ISO 13790 standard for cooling. Natural gas is used for heating and electricity is used for cooling. LCCA based on the total cost approach is performed for 30 years. Optimum insulation thicknesses (U-values) based on climate regions are calculated between 10.5 cm and 17.3 cm (0.30-0.19 W/m2K) for wall, 17.5 cm and 26.8 cm (0.24-0.16 W/m2K) for ceiling, 6.0 cm and 9.8 cm (0.49-0.32 W/m2K) for floor. When compared with the limit values specified in TS 825, it has been determined that the energy savings provided by an insulated building using optimum insulation thicknesses vary between 12.9% and 21.5% according to the region. As a result, it is concluded that the limit U-values should be revised for all regions specified in the TS 825.
- 16 June 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 27 (1) , 2-13
Determination of optimum insulation thickness by life cycle cost analysis for residential buildings in Turkey
The main objective of this study is to determine the optimum insulation thickness of residential buildings in Turkey, under the influence of cooling and heating loads by life cycle cost analysis (LCCA). 5-storey apartment building with an Area/Volume ratio (A/V) of 0.40 m−1 and 10-storey apartment building with an A/V ratio of 0.32 m−1 are taken as reference buildings. The annual energy needs are calculated according to TS 825 standard for heating and TS EN ISO 13790 standard for cooling. Natural gas is used for heating and electricity is used for cooling. LCCA based on the total cost approach is performed for 30 years. Optimum insulation thicknesses (U-values) based on climate regions are calculated between 10.5 cm and 17.3 cm (0.30-0.19 W/m2K) for wall, 17.5 cm and 26.8 cm (0.24-0.16 W/m2K) for ceiling, 6.0 cm and 9.8 cm (0.49-0.32 W/m2K) for floor. When compared with the limit values specified in TS 825, it has been determined that the energy savings provided by an insulated building using optimum insulation thicknesses vary between 12.9% and 21.5% according to the region. As a result, it is concluded that the limit U-values should be revised for all regions specified in the TS 825.
- 1 November 2015
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 40 (44) , 15343-15351
Design and multi-objective optimization of organic Rankine turbine
- 1 November 2015
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 40 (44) , 15343-15351
Design and multi-objective optimization of organic Rankine turbine