Matthew Hanna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthew Hanna has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cornelia Hoehr
Life Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, British Columbia, V6T 2A3, Canada
1 shared publication - Cyril Hnatovsky
Quantum and Nanotechnologies Research Center, National Research Council Canada, 100 Sussex Drive, Ottawa, ON K1A 0R6, Canada
1 shared publication - Dan Grobnic
National Research Council Canada, 100 Sussex Drive, Ottawa, ON K1A 0R6, Canada
1 shared publication - Michael Bakaic
Fibos Inc., Toronto, ON M3J 3E5, Canada
1 shared publication - Stefan K. Zeisler
Life Sciences Division, TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
1 shared publication - Stephen James Mihailov
National Research Council Canada, Ottawa, ON, Canada
1 shared publication
Latest Publications
- Open Access
- 3 July 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (13) , 4610
Fiber-Optic Bragg Gratings for Temperature and Pressure Measurements in Isotope Production Targets for Nuclear Medicine
A Bragg grating inscribed into an inorganic optical fiber was tested in proton and neutron fields up to doses of 472 Gy. Observation showed that radiation had no effect on the performance of the Fiber Bragg Grating (FBG) used as a gauge measuring temperature and pressure. The FBG sensor was subsequently employed to measure the temperature and pressure inside a liquid isotope production target for nuclear medicine. The fiber Bragg grating measured the temperature and pressure of a water target as a 12 MeV proton beam impinged on it in real time and was tested with beam currents of up to 20 µA.
- 3 July 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (13) , 4610
Open AccessFiber-Optic Bragg Gratings for Temperature and Pressure Measurements in Isotope Production Targets for Nuclear Medicine
A Bragg grating inscribed into an inorganic optical fiber was tested in proton and neutron fields up to doses of 472 Gy. Observation showed that radiation had no effect on the performance of the Fiber Bragg Grating (FBG) used as a gauge measuring temperature and pressure. The FBG sensor was subsequently employed to measure the temperature and pressure inside a liquid isotope production target for nuclear medicine. The fiber Bragg grating measured the temperature and pressure of a water target as a 12 MeV proton beam impinged on it in real time and was tested with beam currents of up to 20 µA.