MAMasahiko Ando

Masahiko Ando

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masahiko Ando has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Eisuke Tatsumi

    Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, Japan

    6 shared publications
  • Minoru Ono

    Department of Cardiothoracic Surgery, The University of Tokyo, Japan

    6 shared publications
  • Shunei Kyo

    Department of Therapeutic Strategy for Heart Failure, The University of Tokyo, Japan

    6 shared publications
  • Yoshiaki Takewa

    Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, Japan

    6 shared publications
  • Yoshiyuki Taenaka

    Department of Artificial Organs, National Cerebral and Cardiovascular Center Research Institute, Japan

    6 shared publications
  • Kenji Yamazaki

    Department of Cardiovascular Surgery, Tokyo Women's Medical University, Tokyo, Japan

    5 shared publications

Latest Publications

  • Open Access

    Creating an ideal “off-test mode” for rotary left ventricular assist devices: Establishing a safe and appropriate weaning protocol after myocardial recovery

    by Masahiko Ando, Takashi Nishimura, Yoshiaki Takewa, Shunei Kyo, Minoru Ono, Yoshiyuki Taenaka, Eisuke Tatsumi


  • Coronary Vascular Resistance Increases Under Full Bypass Support of Centrifugal Pumps—Relation Between Myocardial Perfusion and Ventricular Workload During Pump Support

    by Masahiko Ando, Yoshiaki Takewa, Takashi Nishimura, Kenji Yamazaki, Shunei Kyo, Minoru Ono, Tomonori Tsukiya, Toshihide Mizuno, Yoshiyuki Taenaka, Eisuke Tatsumi

    Coronary circulation is closely linked to myocardial oxygen consumption (MVO2), and previous reports have suggested decreased coronary flow (CoF) under left ventricular assist device support. Decreased CoF itself under support is not unfavorable because the native heart can be well unloaded and myocardial oxygen demand is also decreased. There should be an autoregulatory system that would maintain optimal CoF according to oxygen demand; however, the detailed mechanism is still unclear. The aim of the current study is to evaluate the effect of centrifugal pumps on CoF under varied bypass rates in relation to left ventricle workload. A centrifugal pump, EVAHEART (Sun Medical Technology Research Corporation, Nagano, Japan), was installed in an adult goat (n = 10, 61.3 ± 6.5 kg). We set up the following conditions, including Circuit‐Clamp (i.e., no pump support), 50% bypass, and 100% bypass. In these settings, CoF, MVO2, pressure–volume area (PVA), and coronary vascular resistance (CVR) were measured. In 100% bypass, CoF, MVO2, and PVA were all decreased significantly from clamp. While in 50% bypass, CoF and MVO2 decreased from clamp, but not PVA. There was a significant 40% increase in CVR in 100% bypass from clamp. This CVR increase in 100% bypass was possibly due to mechanical collapse of coronary vascular bed itself by pump support or increased vascular tone through autoregulatory system. In clinical settings, we should adjust optimal pump speed so as not to cause this vascular collapse. However, to clarify autoregulatory system of the coronary perfusion, further investigation is ongoing in ischemic and heart failure models.


  • A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial perfusion

    by Masahiko Ando, Yoshiaki Takewa, Takashi Nishimura, Kenji Yamazaki, Shunei Kyo, Minoru Ono, Tomonori Tsukiya, Toshihide Mizuno, Yoshiyuki Taenaka, Eisuke Tatsumi

    The effect of rotary left ventricular assist devices (LVADs) on myocardial perfusion has yet to be clearly elucidated, and several studies have shown decreased coronary flow under rotary LVAD support. We have developed a novel pump controller that can change its rotational speed (RS) in synchronization with the native cardiac cycle. The aim of our study was to evaluate the effect of counterpulse mode, which increases the RS in diastole, during coronary perfusion. Experiments were performed on ten adult goats. The EVAHEART LVAD was installed by the left ventricular uptake and the descending aortic return. Ascending aortic flow, pump flow, and coronary flow of the left main trunk were monitored. Coronary flow was compared under four conditions: circuit-clamp, continuous mode (constant pump speed), counterpulse mode (increased pump speed in diastole), and copulse mode (increased pump speed in systole). There were no significant baseline changes between these groups. In counterpulse mode, coronary flow increased significantly compared with that in continuous mode. The waveform analysis clearly revealed that counterpulse mode mainly resulted in increased diastolic coronary flow. In conclusion, counterpulse mode of rotary LVADs can enhance myocardial perfusion. This novel drive mode can provide great benefits to the patients with end-stage heart failure, especially those with ischemic etiology.


  • Electrocardiogram‐Synchronized Rotational Speed Change Mode in Rotary Pumps Could Improve Pulsatility

    by Masahiko Ando, Takashi Nishimura, Yoshiaki Takewa, Kenji Yamazaki, Shunei Kyo, Minoru Ono, Tomonori Tsukiya, Toshihide Mizuno, Yoshiyuki Taenaka, Eisuke Tatsumi

    Continuous‐flow left ventricular assist devices (LVADs) have greatly improved the prognosis of patients with end‐stage heart failure, even if continuous flow is different from physiological flow in that it has less pulsatility. A novel pump controller of continuous‐flow LVADs has been developed, which can change its rotational speed (RS) in synchronization with the native cardiac cycle, and we speculated that pulsatile mode, which increases RS just in the systolic phase, can create more pulsatility than the current system with constant RS does. The purpose of the present study is to evaluate the effect of this pulsatile mode of continuous‐flow LVADs on pulsatility in in vivo settings. Experiments were performed on eight adult goats (61.7 ± 7.5 kg). A centrifugal pump, EVAHEART (Sun Medical Technology Research Corporation, Nagano, Japan), was installed by the apex drainage and the descending aortic perfusion. A pacing lead for the detection of ventricular electrocardiogram was sutured on the anterior wall of the right ventricle. In the present study, we compared pulse pressure or other parameters in the following three conditions, including Circuit‐Clamp (i.e., no pump support), Continuous mode (constant RS), and Pulsatile mode (increase RS in systole). Assist rate was calculated by dividing pump flow (PF) by the sum of PF and ascending aortic flow (AoF). In continuous and pulsatile modes, these assist rates were adjusted around 80–90%. The following three parameters were used to evaluate pulsatility, including pulse pressure, dp/dt of aortic pressure (AoP), and energy equivalent pulse pressure (EEP = (∫PF*AoP dt)/(∫PF dt), mm Hg). The percent difference between EEP and mean AoP is used as an indicator of pulsatility, and normally it is around 10% of mean AoP in physiological pulse. Both pulse pressure and mean dp/dt max were decreased in continuous mode compared with clamp condition, while those were regained by pulsatile mode nearly to clamp condition (pulse pressure, clamp/continuous/pulsatile, 25.0 ± 7.6/11.7 ± 6.4/22.6 ± 9.8 mm Hg, mean dp/dt max, 481.9 ± 207.6/75.6 ± 36.2/351.1 ± 137.8 mm Hg/s, respectively). In clamp condition, %EEP was 10% higher than mean AoP (P = 0.0078), while in continuous mode, %EEP was nearly equivalent to mean AoP (N.S.). In pulsatile mode, %EEP was 9% higher than mean AoP (P = 0.038). Our newly developed pulsatile mode of continuous‐flow LVADs can produce pulsatility comparable to physiological pulsatile flow. Further investigation on the effect of this novel drive mode on organ perfusion is currently ongoing.


  • A novel counterpulse drive mode of continuous-flow left ventricular assist devices can minimize intracircuit backward flow during pump weaning

    by Masahiko Ando, Takashi Nishimura, Yoshiaki Takewa, Daisuke Ogawa, Kenji Yamazaki, Koichi Kashiwa, Shunei Kyo, Minoru Ono, Yoshiyuki Taenaka, Eisuke Tatsumi

    Recent developments in adjunct therapeutic options for end-stage heart failure have enabled us to remove implanted left ventricular assist devices (LVADs) from more patients than before. However, a safe and proper protocol for pump-off trials is yet to be established, because diastolic backward flow in a pump circuit turns up when it is driven at low-flow conditions. We have developed a novel drive mode of centrifugal pumps that can change its rotational speed in synchronization with the cardiac cycle of the native heart. The purpose of this study was to test-drive this novel system of a centrifugal pump in a mock circulation and to evaluate the effect of the counterpulse mode, which increases pump speed just in diastole, on the amount of this nonphysiological intracircuit retrograde flow. A rotary pump (EVAHEART, Sun Medical Technology Research Corporation) was connected to the mock circulation by left ventricular uptake and ascending aortic return. We drove it in the following four conditions: (A) continuous mode at 1500 rpm, (B) counterpulse mode (systolic 1500 rpm, diastolic 2500 rpm), (C) continuous mode at 2000 rpm, and (D) counterpulse mode (systolic 2000 rpm, diastolic 2500 rpm). Data concerning the rotation speed, pump flow, left ventricular pressure, aortic pressure, and pressure head (i.e., aortic pressure-left ventricular pressure) in each condition were collected. After data collection, we analyzed pump flow, and calculated its forward and backward flow. Counterpulse mode decreased the amounts of pump backward flow compared with the continuous mode [mean backward flow, -4, -1, -0.5, 0 l/min, in (A), (B), (C), and (D) conditions, respectively]. The actual amounts of mean backward flow can be different from those in clinical situations; however, this novel drive mode for rotary pumps can relatively decrease pump backward flow during pump weaning and can be beneficial for safe and proper pump-off trials. Further investigations in in vivo settings are currently ongoing.


  • What is the ideal off-test trial for continuous-flow ventricular-assist-device explantation? Intracircuit back-flow analysis in a mock circulation model

    by Masahiko Ando, Takashi Nishimura, Yoshiaki Takewa, Daisuke Ogawa, Kenji Yamazaki, Koichi Kashiwa, Shunei Kyo, Minoru Ono, Yoshiyuki Taenaka, Eisuke Tatsumi

    Bridge to recovery has become a major goal after left-ventricular-assist-device (LVAD) implantation thanks to recent development in adjunctive therapies. Precise assessment of native heart function under minimum LVAD support is the key for successful LVAD explantation. However, weaning of centrifugal LVADs normally generates diastolic intracircuit backward flow. This retrograde flow may become excessive load for the native heart during off-pump test. The flow itself is an inevitable characteristic of centrifugal pumps. Therefore, evaluating this retrograde flow in vitro is of considerable significance, even if its amount is different from that in clinical settings. The purpose of this study was to assess diastolic backflow of continuous-flow centrifugal LVADs in a mock circulation model. A centrifugal LVAD (EVAHEART, Sun Medical Technology) was installed in a mock circulation model by the left ventricle uptake and the ascending aortic return. Pump flow was measured at the pump rotational speed of 1000, 1500, 2000, and 2500 rpm, and pulse rate of the virtual native heart was varied to 60, 90, and 120 beats/min. After data collection, pump flow was integrated, and forward and backward intracircuit flow were calculated. As a result, nonphysiological reverse flow of approximately 2.0 L/min exists at the rotational speed, providing 0 L/min mean pump flow. An ideal off-test trial condition should be realizing both ± 0 L/min pump flow and no intracircuit backward flow at the same time. We are developing a novel EVAHEART drive mode that can change its rotational speed in synchronization with cardiac cycle with the aim of controlling this retrograde flow with the new drive mode and creating an ideal off-test condition.