Catherine C. Cooksey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Catherine C. Cooksey has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
David W. Allen
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
3 shared publicationsBenjamin K. Tsai
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
2 shared publications- Daniel Poitras
National Research Council Canada
2 shared publications - Heather J. Patrick
National Institute of Standards and Technology
2 shared publications Luke J. Sandilands
National Research Council of Canada
2 shared publicationsMaria E. Nadal
National Institute of Standards and Technology
2 shared publications
Latest Publications
- 16 January 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (3) , 972-977
Improved ultraviolet measurement capabilities of NIST’s reference transmittance spectrophotometer
The National Institute of Standards and Technology (NIST) has maintained and operated custom-built reference instruments to establish the national scale for regular spectral transmittance for more than 50 years. In this paper, we report on improvements to the performance of NIST’s current iteration of the reference instrument, the reference transmittance spectrophotometer (RTS), in the ultraviolet (UV) and visible spectral range. The improvements include the installation of a new UV source for increased spectral radiance and a monitor line for a reduced noise-to-signal ratio. A new uncertainty budget and validation measurements are presented. A reduction of uncertainties by 70% or more is achieved for UV wavelengths.
- 16 January 2026
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (3) , 972-977
Improved ultraviolet measurement capabilities of NIST’s reference transmittance spectrophotometer
The National Institute of Standards and Technology (NIST) has maintained and operated custom-built reference instruments to establish the national scale for regular spectral transmittance for more than 50 years. In this paper, we report on improvements to the performance of NIST’s current iteration of the reference instrument, the reference transmittance spectrophotometer (RTS), in the ultraviolet (UV) and visible spectral range. The improvements include the installation of a new UV source for increased spectral radiance and a monitor line for a reduced noise-to-signal ratio. A new uncertainty budget and validation measurements are presented. A reduction of uncertainties by 70% or more is achieved for UV wavelengths.
- 15 December 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (5) , A156-A163
2025 OIC Manufacturing “Road Runner” Challenge [Invited]
Measurements of the fabricated optical filters submitted to the Manufacturing Challenge (MC) organized for Optica’s Topical Meeting on Optical Interference Coatings held in Tucson, AZ, in May 2025, are presented. For this ninth MC, participants were asked to design and deposit, on a provided substrate, a filter with transmittance ( T ) and front- and back-reflectance ( R ) spectra (with light incident from the front and back, respectively) matching target values specified in the 400 nm to 1100 nm spectral interval. The challenge problem was selected to require at least one absorbing layer in the design in order to ensure a good performance. Six teams from three countries participated and submitted a total of 10 samples, all coated on both sides, with total thicknesses ranging from 3589 nm to 8088 nm and comprised of 31 to 135 layers. The entries were measured at four independent laboratories; the resulting merit function values obtained when comparing the measured spectra to the targets were used to rank the filters and determine a winner. In the analysis of the results, observations will be made about coating design, fabrication, and measurement.
- 15 December 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 65 (5) , A156-A163
2025 OIC Manufacturing “Road Runner” Challenge [Invited]
Measurements of the fabricated optical filters submitted to the Manufacturing Challenge (MC) organized for Optica’s Topical Meeting on Optical Interference Coatings held in Tucson, AZ, in May 2025, are presented. For this ninth MC, participants were asked to design and deposit, on a provided substrate, a filter with transmittance ( T ) and front- and back-reflectance ( R ) spectra (with light incident from the front and back, respectively) matching target values specified in the 400 nm to 1100 nm spectral interval. The challenge problem was selected to require at least one absorbing layer in the design in order to ensure a good performance. Six teams from three countries participated and submitted a total of 10 samples, all coated on both sides, with total thicknesses ranging from 3589 nm to 8088 nm and comprised of 31 to 135 layers. The entries were measured at four independent laboratories; the resulting merit function values obtained when comparing the measured spectra to the targets were used to rank the filters and determine a winner. In the analysis of the results, observations will be made about coating design, fabrication, and measurement.
- 8 September 2023
- Published by American Physical Society (APS) in Physical Review A
- Vol. 108 (3) , 032809
Radiative decay rate and branching fractions of MgF
We report measured and calculated values of radiative decay rates and vibrational branching fractions for the state of . The decay rate measurements use time-correlated single-photon counting with roughly 1% total uncertainty. Branching-fraction measurements are performed using two calibrated imaging systems to achieve few percent total uncertainty. We use the multireference relativistic ab initio methods to calculate the Franck-Condon factors and transition dipole moments required to determine the decay rates and the branching fractions. The measurements provide a precision benchmark for testing the accuracy of the molecular structure calculations. The determination of the decay rate and vibrational branching fractions can be used to inform future optical cycling and laser cooling schemes for the MgF molecule.- 8 September 2023
- Published by American Physical Society (APS) in Physical Review A
- Vol. 108 (3) , 032809
Radiative decay rate and branching fractions of MgF
We report measured and calculated values of radiative decay rates and vibrational branching fractions for the state of . The decay rate measurements use time-correlated single-photon counting with roughly 1% total uncertainty. Branching-fraction measurements are performed using two calibrated imaging systems to achieve few percent total uncertainty. We use the multireference relativistic ab initio methods to calculate the Franck-Condon factors and transition dipole moments required to determine the decay rates and the branching fractions. The measurements provide a precision benchmark for testing the accuracy of the molecular structure calculations. The determination of the decay rate and vibrational branching fractions can be used to inform future optical cycling and laser cooling schemes for the MgF molecule.- 11 January 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (7) , B104-B111
2022 Optical Interference Coatings Conference: Manufacturing Problem Contest [Invited]
Participants in the 2022 Manufacturing Problem Contest were challenged to fabricate an optical filter with a specified stepped transmittance spanning three orders of magnitude from 400 to 1100 nm. The problem required that contestants be versed in the design, deposition, and measurement of optical filters to achieve good results. Nine samples from five institutions were submitted with total thicknesses between 5.9 and 53.5 mu m with between 68 and 1743 layers. The filter spectra were measured by three independent laboratories. The results were presented in June 2022 at the Optical Interference Coatings Conference in Whistler, B.C., Canada. (c) 2023 Optica Publishing Group
- 11 January 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (7) , B104-B111
2022 Optical Interference Coatings Conference: Manufacturing Problem Contest [Invited]
Participants in the 2022 Manufacturing Problem Contest were challenged to fabricate an optical filter with a specified stepped transmittance spanning three orders of magnitude from 400 to 1100 nm. The problem required that contestants be versed in the design, deposition, and measurement of optical filters to achieve good results. Nine samples from five institutions were submitted with total thicknesses between 5.9 and 53.5 mu m with between 68 and 1743 layers. The filter spectra were measured by three independent laboratories. The results were presented in June 2022 at the Optical Interference Coatings Conference in Whistler, B.C., Canada. (c) 2023 Optica Publishing Group
- 4 April 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (11) , 2957-2966
Pyroelectric detector-based method for low uncertainty spectral irradiance and radiance responsivity calibrations in the infrared using tunable lasers
The standard uncertainty of detector-based radiance and irradiance responsivity calibrations in the short-wave infrared (SWIR) traditionally has been limited to around 1% or higher by the poor spatial uniformity of detectors used to transfer the scale from radiant power. Pyroelectric detectors offer a solution that avoids the spatial uniformity uncertainty but also introduces additional complications due to alternating current (AC) measurement techniques. Herein, a new, to the best of our knowledge, method for low uncertainty irradiance responsivity calibrations in the SWIR is presented. An absolute spectral irradiance responsivity scale was placed on two pyroelectric detectors (PED) at wavelengths λ from 500 to 3400 nm. The total combined uncertainty ( k = 1 ) was ≈ 0.28 % ( > 1000 nm ), 0.44% (900 nm), and 0.36% ( ≈ 950 nm and < 900 nm ) for PED #1 and 0.34% ( > 1000 nm ), 0.48% (900 nm), and 0.42% ( ≈ 950 nm and < 900 nm ) for PED #2. This was done by utilizing a demodulation technique to digitally analyze the time-dependent AC waveforms, which obviates the use of lock-in amplifiers and avoids associated additional uncertainty components.
- 4 April 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (11) , 2957-2966
Pyroelectric detector-based method for low uncertainty spectral irradiance and radiance responsivity calibrations in the infrared using tunable lasers
The standard uncertainty of detector-based radiance and irradiance responsivity calibrations in the short-wave infrared (SWIR) traditionally has been limited to around 1% or higher by the poor spatial uniformity of detectors used to transfer the scale from radiant power. Pyroelectric detectors offer a solution that avoids the spatial uniformity uncertainty but also introduces additional complications due to alternating current (AC) measurement techniques. Herein, a new, to the best of our knowledge, method for low uncertainty irradiance responsivity calibrations in the SWIR is presented. An absolute spectral irradiance responsivity scale was placed on two pyroelectric detectors (PED) at wavelengths λ from 500 to 3400 nm. The total combined uncertainty ( k = 1 ) was ≈ 0.28 % ( > 1000 nm ), 0.44% (900 nm), and 0.36% ( ≈ 950 nm and < 900 nm ) for PED #1 and 0.34% ( > 1000 nm ), 0.48% (900 nm), and 0.42% ( ≈ 950 nm and < 900 nm ) for PED #2. This was done by utilizing a demodulation technique to digitally analyze the time-dependent AC waveforms, which obviates the use of lock-in amplifiers and avoids associated additional uncertainty components.
- 27 September 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (28) , 8774-8786
Bidirectional reflectance capabilities of the NIST Robotic Optical Scattering Instrument
The National Institute of Standards and Technology (NIST) Robotic Optical Scattering Instrument (ROSI) serves as the national reference instrument for specular and diffuse bidirectional reflectance measurements in the ultraviolet to short-wave infrared wavelength regions. This paper gives a comprehensive overview of the design, operation, and capabilities of ROSI. We describe measurement methods for diffuse and specular reflectance, identify and quantify the elements of the uncertainty budget, and validate the reflectance scale through comparison with NIST’s previous reference instrument, the Spectral Tri-function Automated Reference Reflectometer. Examples of the range of ROSI’s capabilities, including the limits for low-reflectance measurements and a research application using out-of-plane measurements of bidirectional reflectance for remote sensing reference reflectors, are also covered.
- 27 September 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (28) , 8774-8786
Bidirectional reflectance capabilities of the NIST Robotic Optical Scattering Instrument
The National Institute of Standards and Technology (NIST) Robotic Optical Scattering Instrument (ROSI) serves as the national reference instrument for specular and diffuse bidirectional reflectance measurements in the ultraviolet to short-wave infrared wavelength regions. This paper gives a comprehensive overview of the design, operation, and capabilities of ROSI. We describe measurement methods for diffuse and specular reflectance, identify and quantify the elements of the uncertainty budget, and validate the reflectance scale through comparison with NIST’s previous reference instrument, the Spectral Tri-function Automated Reference Reflectometer. Examples of the range of ROSI’s capabilities, including the limits for low-reflectance measurements and a research application using out-of-plane measurements of bidirectional reflectance for remote sensing reference reflectors, are also covered.
- 1 January 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (1A)
Report on the SIM photometry and radiometry Key comparison of spectral regular transmittance
Main text: This report details the results of the Inter-American Metrology System (SIM) key comparison on regular spectral transmittance (SIM.PR-K6.2010). Eight national metrology institutes participated in the comparison, which covered the spectral range from 380 nm to 1000 nm and the nominal transmittance range from 0.1 % to 90 % transmittance. The protocol mirrored that of the key comparison conducted by the Consultative Committee on Photometry and Radiometry (CCPR-K6.2010). The National Institute of Standards and Technology (NIST) served as the pilot. Each participant received a single set of 5 comparison (neutral density) filters to measure. The pilot measured all sets before and after the participant measurements. All measurements were completed between December 2016 and February 2018. The results of this comparison were linked to the key comparison reference value (KCRV) of the CCPR comparison and are expressed in terms of degrees of equivalence. While most of the participants can adequately measure spectral regular transmittance and evaluate its uncertainty, there are some cases of non-equivalence that will require further investigation on the part of the participants. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (1A)
Report on the SIM photometry and radiometry Key comparison of spectral regular transmittance
Main text: This report details the results of the Inter-American Metrology System (SIM) key comparison on regular spectral transmittance (SIM.PR-K6.2010). Eight national metrology institutes participated in the comparison, which covered the spectral range from 380 nm to 1000 nm and the nominal transmittance range from 0.1 % to 90 % transmittance. The protocol mirrored that of the key comparison conducted by the Consultative Committee on Photometry and Radiometry (CCPR-K6.2010). The National Institute of Standards and Technology (NIST) served as the pilot. Each participant received a single set of 5 comparison (neutral density) filters to measure. The pilot measured all sets before and after the participant measurements. All measurements were completed between December 2016 and February 2018. The results of this comparison were linked to the key comparison reference value (KCRV) of the CCPR comparison and are expressed in terms of degrees of equivalence. While most of the participants can adequately measure spectral regular transmittance and evaluate its uncertainty, there are some cases of non-equivalence that will require further investigation on the part of the participants. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 7 June 2017
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 122, 1-5
Reference Data Set of Human Skin Reflectance
This data set contains 100 reference reflectance spectra of human skin, spanning the wavelength region from 250 nm to 2500 nm. The spectra were acquired with a commercial spectrophotometer and are directly traceable to the national scale for directional-hemispherical reflectance factor.
- 7 June 2017
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 122, 1-5
Reference Data Set of Human Skin Reflectance
This data set contains 100 reference reflectance spectra of human skin, spanning the wavelength region from 250 nm to 2500 nm. The spectra were acquired with a commercial spectrophotometer and are directly traceable to the national scale for directional-hemispherical reflectance factor.
- 24 April 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (13) , 4006-4015
Bidirectional reflectance scale comparison between NIST and PTB
Interlaboratory comparisons, referred to as key comparisons, are completed for many metrological units within the framework of the mutual recognition arrangement of the Bureau International des Poids et Mesures. These comparisons are the responsibility of consultative committees of the different metrological areas. In the case of the Consultative Committee for Photometry and Radiometry, there are currently about 20 key comparisons for various measurands. While interest in the field of bidirectional reflectance has been growing in recent years among users in industry and research and development, there is currently no dedicated key comparison to demonstrate scale conformity. This is the basis of the comparison of the bidirectional reflectance scales between the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). Measurements of two distinct sets of white diffuse reflectance standards, two sintered polytetrafluoroethylene samples and two matte ceramic samples, were performed using the common and widely used geometry. The wavelength range of the comparison spans the ultraviolet () to the near infrared (), a technically important region. In total, five different facilities participated in this bilateral investigation. The results of the comparison show good agreement within the combined uncertainties.- 24 April 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (13) , 4006-4015
Bidirectional reflectance scale comparison between NIST and PTB
Interlaboratory comparisons, referred to as key comparisons, are completed for many metrological units within the framework of the mutual recognition arrangement of the Bureau International des Poids et Mesures. These comparisons are the responsibility of consultative committees of the different metrological areas. In the case of the Consultative Committee for Photometry and Radiometry, there are currently about 20 key comparisons for various measurands. While interest in the field of bidirectional reflectance has been growing in recent years among users in industry and research and development, there is currently no dedicated key comparison to demonstrate scale conformity. This is the basis of the comparison of the bidirectional reflectance scales between the National Institute of Standards and Technology (NIST) and the Physikalisch-Technische Bundesanstalt (PTB). Measurements of two distinct sets of white diffuse reflectance standards, two sintered polytetrafluoroethylene samples and two matte ceramic samples, were performed using the common and widely used geometry. The wavelength range of the comparison spans the ultraviolet () to the near infrared (), a technically important region. In total, five different facilities participated in this bilateral investigation. The results of the comparison show good agreement within the combined uncertainties.- 31 March 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (10) , 3064-3071
Establishment and application of the 0/45 reflectance factor scale over the shortwave infrared
This paper describes the establishment and application of the 0/45 reflectance factor scale in the shortwave infrared (SWIR) from 1100 to 2500 nm. Design, characterization, and the demonstration of a four-stage, extended indium-gallium-arsenide radiometer to perform reflectance measurements in the SWIR have been previously discussed. Here, we focus on the incorporation of the radiometer into the national reference reflectometer, its validation through comparison measurements, and the uncertainty budget. Next, this capability is applied to the measurement of three different diffuser materials. The 0/45 spectral reflectance factors for these materials are reported and compared to their respective 6/di spectral reflectance factors.
- 31 March 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (10) , 3064-3071
Establishment and application of the 0/45 reflectance factor scale over the shortwave infrared
This paper describes the establishment and application of the 0/45 reflectance factor scale in the shortwave infrared (SWIR) from 1100 to 2500 nm. Design, characterization, and the demonstration of a four-stage, extended indium-gallium-arsenide radiometer to perform reflectance measurements in the SWIR have been previously discussed. Here, we focus on the incorporation of the radiometer into the national reference reflectometer, its validation through comparison measurements, and the uncertainty budget. Next, this capability is applied to the measurement of three different diffuser materials. The 0/45 spectral reflectance factors for these materials are reported and compared to their respective 6/di spectral reflectance factors.