  • Comparison of bidirectional reflectance distribution function scales over the hemisphere

    by Ellie Molloy, Heather Patrick, Kai-Olaf Hauer, Dirk Hünerhoff, Tatjana Quast

    Measurements of both hemispherical and directional diffuse reflectance are regularly used in a range of industries to aid in quantifying the appearance of different objects, with increasing demand for metrologically traceable measurements of these quantities. While there have been several comparisons of diffuse reflectance scales, there have been fewer comparisons of bidirectional reflectance distribution function (BRDF) scales between national metrology institutes, and BRDF comparisons have been restricted to a narrow range of measurement geometries. This paper expands upon previous work by comparing BRDF scales over the whole detection hemisphere with normal incidence and comparing diffuse reflectance values calculated by integrating these BRDF measurements with integrating sphere-based diffuse reflectance measurements. The results of this comparison demonstrate the current limits of agreement between BRDF measurements and highlight the discrepancy between goniospectrophotometric and integrating sphere-based realizations of diffuse reflectance.

  • Improved ultraviolet measurement capabilities of NIST’s reference transmittance spectrophotometer

    by Catherine C. Cooksey, Thomas C. Larason, Heather J. Patrick, Clarence Zarobila

    The National Institute of Standards and Technology (NIST) has maintained and operated custom-built reference instruments to establish the national scale for regular spectral transmittance for more than 50 years. In this paper, we report on improvements to the performance of NIST’s current iteration of the reference instrument, the reference transmittance spectrophotometer (RTS), in the ultraviolet (UV) and visible spectral range. The improvements include the installation of a new UV source for increased spectral radiance and a monitor line for a reduced noise-to-signal ratio. A new uncertainty budget and validation measurements are presented. A reduction of uncertainties by 70% or more is achieved for UV wavelengths.


  • Ultraviolet to short-wave infrared spectral reflectance

    by Heather Patrick, Clarence Zarobila

    The National Institute of Standards and Technology performs calibrations of spectral reflectance measurements in the ultraviolet (UV) to short-wave infrared (SWIR) spectral regions using the Robotic Optical Scattering Instrument (ROSI) and its associated Reference Integrating Sphere (RIS). This special publication gives a comprehensive overview of the design, operation, and capabilities of this facility. Measurement methods for spectral reflectance, the elements of the uncertainty budget, and validation of the reflectance scale through comparison with NIST’s previous reference instrument, the Spectral Tri-function Automated Reference Reflectometer (STARR), are described. Examples of calibration measurements, including specular reflectance of mirrors, bidirectional reflectance of diffuse reflectors, and directional-hemispherical reflectance, are given. Examples of typical calibration reports are also provided.


  • Validated UV-C bidirectional reflectance distribution function measurements with a spectrophotometer directional reflectance module

    by Aaron M. Goldfain, Grace E. Waters, Lynn Davis, Heather J. Patrick, Thomas A. Germer

    The efficacy and safety of UV disinfection systems depend on the radiant flux throughout the space being disinfected, which in turn depends on the directional reflectance of materials located within the space. Little publicly available data exists on the directional reflectance of common materials in the germicidal UV spectral range, 220–280 nm. We present methods to validate directional reflectance (bidirectional reflectance distribution function) measurements performed with a spectrophotometer and provide measurement results for materials commonly found in public spaces. The data presented may lead to improved models of UV disinfection efficacy and safety, and the methods described will enable other researchers to readily collect traceable UV directional reflectance data.


  • Bidirectional reflectance capabilities of the NIST Robotic Optical Scattering Instrument

    by Heather J. Patrick, Catherine C. Cooksey, Thomas A. Germer, Maria E. Nadal, Clarence J. Zarobila

    The National Institute of Standards and Technology (NIST) Robotic Optical Scattering Instrument (ROSI) serves as the national reference instrument for specular and diffuse bidirectional reflectance measurements in the ultraviolet to short-wave infrared wavelength regions. This paper gives a comprehensive overview of the design, operation, and capabilities of ROSI. We describe measurement methods for diffuse and specular reflectance, identify and quantify the elements of the uncertainty budget, and validate the reflectance scale through comparison with NIST’s previous reference instrument, the Spectral Tri-function Automated Reference Reflectometer. Examples of the range of ROSI’s capabilities, including the limits for low-reflectance measurements and a research application using out-of-plane measurements of bidirectional reflectance for remote sensing reference reflectors, are also covered.


  • Optical reflectance of pyrheliometer absorption cavities: progress toward SI-traceable measurements of solar irradiance

    by Heather J. Patrick, Thomas A. Germer, Clarence J. Zarobila, Catherine C. Cooksey, Howard W. Yoon

    We have accurately determined the absorptance of three pyrheliometer cavities at 532 nm by measuring the residual reflectance using an angle-resolved bidirectional reflectometer. Measurements were performed at a normal incidence as a function of the viewing angle and position on the cavity cone. By numerically integrating the measured angle-resolved scatter over both the direction and position and accounting for an obstructed view of the cavity, we determined that the effective cavity reflectance was between 8×10−4 and 9×10−4. Thus, the absorptance of the three cavities ranged from 0.99909±0.00014 to 0.99922±0.00012 (k=2 combined expanded uncertainties). These measurements, when extended over the spectral range of operation of the pyrheliometer, are required to establish SI traceability for absolute solar irradiance measurements.


  • Open Access

    Table of Contents

    by Mary Murphy, Leila Barraj, Dena Herman, Xiaoyu Bi, Rachel Cheatham, Randolph, Meghan O'Connell, Kathryn Henderson, Joerg Luedicke, Marlene Schwartz, et al.

  • Scatterfield microscopy using back focal plane imaging with an engineered illumination field

    by Heather J Patrick, Ravikiran Attota, Bryan M Barnes, Thomas A Germer, Michael T Stocker, Richard M Silver, Michael R Bishop

    We have implemented back focal plane (conoscopic) imaging in an optical microscope that has also been modified to allow selection of the illumination angles and polarization at the sample, and collected back focal plane images of silicon on silicon grating scatterometry targets with varying line widths. Using a slit illumination mask, the zero-order diffraction versus angle for −60° to +60° incident angles at a given polarization was obtained from a single image. By using reference images taken on a flat silicon background, we correct the raw target images for illumination source inhomogeneities and polarization-dependent transmission of the optics, and convert them to reflectance versus angle data for s- and p-polarizations, similar to that obtained from angle-resolved grating scatterometry. As with conventional scatterometry, the target lines need not be resolved for the reflectance signature to show sensitivity to small changes in the grating parameters. For a series of 300 nm pitch targets with line widths from 150 nm to 157 nm, we demonstrate nanometer-level sensitivity to line width with good repeatability, using 546 nm illumination. Additionally, we demonstrate a technique for separating the zero order from higher order diffraction on targets with multiple diffraction orders, allowing collection of both zero and higher order diffraction versus angle from the back focal plane image. As conventional images can be easily collected on the same microscope, the method provides a powerful tool for combining imaging metrology with scatterometry for optical critical dimension measurements in semiconductors.