Ingrid Haga Oevreeide
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ingrid Haga Oevreeide has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Bjorn Torger Stokke
Norwegian University of Science and Technology (NTNU)
7 shared publications - Joanna Zemła
Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland
5 shared publications - Marcin Luty
Department of Biophysical Microstructures, Institute of Nuclear Physics, Polish Academy of Sciences, PL-31342, Kraków, Poland
5 shared publications - Małgorzata Lekka
Department of Biophysical Microstructures, Institute of Nuclear Physics, Polish Academy of Sciences, Kraków, Poland
5 shared publications - Renata Szydlak
Department of Bioinformatics and Telemedicine, Jagiellonian University Medical College, Krakow, Poland
5 shared publications - Victorien Prot
Biomechanics, Department of Structural Engineering, The Norwegian University of Science and Technology (NTNU), NO-7491, Trondheim, Norway
5 shared publications
Latest Publications
- 21 January 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 298, 118410
Identification of glycosylation-related changes in migratory and mechanical properties of bladder cancer cells
- 21 January 2026
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 298, 118410
Identification of glycosylation-related changes in migratory and mechanical properties of bladder cancer cells
- Open Access
Migration, proliferation, and elasticity of bladder cancer cells on lectin-coated surfaces
The alterations in migration, proliferation, and mechanics of cells observed during cancer progression can potentially be linked to enhanced tumor invasiveness. These properties are frequently attributed to the ability to form distant metastasis; however, the direct mutual connection between these properties is not always proven. Here, we studied the migratory, proliferative, and mechanical phenotype of three bladder cancer cells originating from various stages of cancer progression, i.e., non-malignant cell cancer of ureter (HCV29 cells), bladder carcinoma (HT1376 cells) and transitional bladder carcinoma (T24 cells). The results were linked with the organization of actin filaments because of their major role in cell migration. The results classified cells into non-malignant, non-invasive, and invasive, revealing the significant impact of actin filaments in bladder cancer invasion. Based on the reported changes in cancer cell glycosylation, the potential applicability of the observed cancer-related changes to identify invasive cells was demonstrated for the lectin-coated surfaces, which is the potential surface modification for biosensors.
Open AccessMigration, proliferation, and elasticity of bladder cancer cells on lectin-coated surfaces
The alterations in migration, proliferation, and mechanics of cells observed during cancer progression can potentially be linked to enhanced tumor invasiveness. These properties are frequently attributed to the ability to form distant metastasis; however, the direct mutual connection between these properties is not always proven. Here, we studied the migratory, proliferative, and mechanical phenotype of three bladder cancer cells originating from various stages of cancer progression, i.e., non-malignant cell cancer of ureter (HCV29 cells), bladder carcinoma (HT1376 cells) and transitional bladder carcinoma (T24 cells). The results were linked with the organization of actin filaments because of their major role in cell migration. The results classified cells into non-malignant, non-invasive, and invasive, revealing the significant impact of actin filaments in bladder cancer invasion. Based on the reported changes in cancer cell glycosylation, the potential applicability of the observed cancer-related changes to identify invasive cells was demonstrated for the lectin-coated surfaces, which is the potential surface modification for biosensors.
- Open Access
- 25 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116337
Detecting normal and cancer skin cells via glycosylation and adhesion signatures: A path to enhanced microfluidic phenotyping
- 25 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 258, 116337
Open AccessDetecting normal and cancer skin cells via glycosylation and adhesion signatures: A path to enhanced microfluidic phenotyping
- Open Access
- 4 May 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (9) , 8213
Bladder Cancer Cells Interaction with Lectin-Coated Surfaces under Static and Flow Conditions
Aberrant expression of glycans, i.e., oligosaccharide moiety covalently attached to proteins or lipids, is characteristic of various cancers, including urothelial ones. The binding of lectins to glycans is classified as molecular recognition, which makes lectins a strong tool for understanding their role in developing diseases. Here, we present a quantitative approach to tracing glycan–lectin interactions in cells, from the initial to the steady phase of adhesion. The cell adhesion was measured between urothelial cell lines (non-malignant HCV29 and carcinoma HT1376 and T24 cells) and lectin-coated surfaces. Depending on the timescale, single-cell force spectroscopy, and adhesion assays conducted in static and flow conditions were applied. The obtained results reveal that the adhesion of urothelial cells to two specific lectins, i.e., phytohemagglutinin-L and wheat germ agglutinin, was specific and selective. Thus, these lectins can be applied to selectively capture, identify, and differentiate between cancer types in a label-free manner. These results open up the possibility of designing lectin-based biosensors for diagnostic or prognostic purposes and developing strategies for drug delivery that could target cancer-associated glycans.
- 4 May 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (9) , 8213
Open AccessBladder Cancer Cells Interaction with Lectin-Coated Surfaces under Static and Flow Conditions
Aberrant expression of glycans, i.e., oligosaccharide moiety covalently attached to proteins or lipids, is characteristic of various cancers, including urothelial ones. The binding of lectins to glycans is classified as molecular recognition, which makes lectins a strong tool for understanding their role in developing diseases. Here, we present a quantitative approach to tracing glycan–lectin interactions in cells, from the initial to the steady phase of adhesion. The cell adhesion was measured between urothelial cell lines (non-malignant HCV29 and carcinoma HT1376 and T24 cells) and lectin-coated surfaces. Depending on the timescale, single-cell force spectroscopy, and adhesion assays conducted in static and flow conditions were applied. The obtained results reveal that the adhesion of urothelial cells to two specific lectins, i.e., phytohemagglutinin-L and wheat germ agglutinin, was specific and selective. Thus, these lectins can be applied to selectively capture, identify, and differentiate between cancer types in a label-free manner. These results open up the possibility of designing lectin-based biosensors for diagnostic or prognostic purposes and developing strategies for drug delivery that could target cancer-associated glycans.
- Open Access
On the Determination of Mechanical Properties of Aqueous Microgels—Towards High-Throughput Characterization
Aqueous microgels are distinct entities of soft matter with mechanical signatures that can be different from their macroscopic counterparts due to confinement effects in the preparation, inherently made to consist of more than one domain (Janus particles) or further processing by coating and change in the extent of crosslinking of the core. Motivated by the importance of the mechanical properties of such microgels from a fundamental point, but also related to numerous applications, we provide a perspective on the experimental strategies currently available and emerging tools being explored. Albeit all techniques in principle exploit enforcing stress and observing strain, the realization differs from directly, as, e.g., by atomic force microscope, to less evident in a fluid field combined with imaging by a high-speed camera in high-throughput strategies. Moreover, the accompanying analysis strategies also reflect such differences, and the level of detail that would be preferred for a comprehensive understanding of the microgel mechanical properties are not always implemented. Overall, the perspective is that current technologies have the capacity to provide detailed, nanoscopic mechanical characterization of microgels over an extended size range, to the high-throughput approaches providing distributions over the mechanical signatures, a feature not readily accessible by atomic force microscopy and micropipette aspiration.
Open AccessOn the Determination of Mechanical Properties of Aqueous Microgels—Towards High-Throughput Characterization
Aqueous microgels are distinct entities of soft matter with mechanical signatures that can be different from their macroscopic counterparts due to confinement effects in the preparation, inherently made to consist of more than one domain (Janus particles) or further processing by coating and change in the extent of crosslinking of the core. Motivated by the importance of the mechanical properties of such microgels from a fundamental point, but also related to numerous applications, we provide a perspective on the experimental strategies currently available and emerging tools being explored. Albeit all techniques in principle exploit enforcing stress and observing strain, the realization differs from directly, as, e.g., by atomic force microscope, to less evident in a fluid field combined with imaging by a high-speed camera in high-throughput strategies. Moreover, the accompanying analysis strategies also reflect such differences, and the level of detail that would be preferred for a comprehensive understanding of the microgel mechanical properties are not always implemented. Overall, the perspective is that current technologies have the capacity to provide detailed, nanoscopic mechanical characterization of microgels over an extended size range, to the high-throughput approaches providing distributions over the mechanical signatures, a feature not readily accessible by atomic force microscopy and micropipette aspiration.
- Open Access
- 13 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (5) , 556
Characterization of Mixing Performance Induced by Double Curved Passive Mixing Structures in Microfluidic Channels
Functionalized sensor surfaces combined with microfluidic channels are becoming increasingly important in realizing efficient biosensing devices applicable to small sample volumes. Relaxing the limitations imposed by laminar flow of the microfluidic channels by passive mixing structures to enhance analyte mass transfer to the sensing area will further improve the performance of these devices. In this paper, we characterize the flow performance in a group of microfluidic flow channels with novel double curved passive mixing structures (DCMS) fabricated in the ceiling. The experimental strategy includes confocal imaging to monitor the stationary flow patterns downstream from the inlet where a fluorophore is included in one of the inlets in a Y-channel microfluidic device. Analyses of the fluorescence pattern projected both along the channel and transverse to the flow direction monitored details in the developing homogenization. The mixing index (MI) as a function of the channel length was found to be well accounted for by a double-exponential equilibration process, where the different parameters of the DCMS were found to affect the extent and length of the initial mixing component. The range of MI for a 1 cm channel length for the DCMS was 0.75–0.98, which is a range of MI comparable to micromixers with herringbone structures. Overall, this indicates that the DCMS is a high performing passive micromixer, but the sensitivity to geometric parameter values calls for the selection of certain values for the most efficient mixing.
- 13 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (5) , 556
Open AccessCharacterization of Mixing Performance Induced by Double Curved Passive Mixing Structures in Microfluidic Channels
Functionalized sensor surfaces combined with microfluidic channels are becoming increasingly important in realizing efficient biosensing devices applicable to small sample volumes. Relaxing the limitations imposed by laminar flow of the microfluidic channels by passive mixing structures to enhance analyte mass transfer to the sensing area will further improve the performance of these devices. In this paper, we characterize the flow performance in a group of microfluidic flow channels with novel double curved passive mixing structures (DCMS) fabricated in the ceiling. The experimental strategy includes confocal imaging to monitor the stationary flow patterns downstream from the inlet where a fluorophore is included in one of the inlets in a Y-channel microfluidic device. Analyses of the fluorescence pattern projected both along the channel and transverse to the flow direction monitored details in the developing homogenization. The mixing index (MI) as a function of the channel length was found to be well accounted for by a double-exponential equilibration process, where the different parameters of the DCMS were found to affect the extent and length of the initial mixing component. The range of MI for a 1 cm channel length for the DCMS was 0.75–0.98, which is a range of MI comparable to micromixers with herringbone structures. Overall, this indicates that the DCMS is a high performing passive micromixer, but the sensitivity to geometric parameter values calls for the selection of certain values for the most efficient mixing.
- Open Access
- 2 December 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 31 (1) , 015006
Curved passive mixing structures: a robust design to obtain efficient mixing and mass transfer in microfluidic channels
Analyte mixing and delivery to a functionalized sensor surface are important to realize several advantages associated with biosensors integrated with microfluidic channels. Here, we present a comparison between a herringbone structure (HBS) and a curved passive mixing structure of their efficiency at facilitating mixing and surface saturation using fluorescein included in one of the inlets of a Y-channel microfluidic device. We performed a large parametric study to assess the effects of varying the height of the microfluidic channel as well as the height, width, and spacing of the passive mixing structures. Scanning confocal microscopy combined with a custom-designed image-analysis procedure were utilized to visualize and quantify the observed changes in efficiency in inducing solute mixing by the different designs. The flow patterns within the channels were found to vary significantly with changes in the geometry of the passive mixing structures, which in turn affected the efficiency of the channel at mixing the fluid and saturating the surface opposite the mixing structures. The solute mixing as a function of the channel length was also determined; an initial slow mixing rate does not always coincide with a low mixing index (MI). We found that the range of MIs for the curved mixing structure 1 cm downstream from the inlet was 0.85–0.99 whilst for our HBS it was 0.74–0.98, depending on the design parameters of the passive mixing structures. Overall, this study shows that the curved passive mixing structure family is more robust in inducing efficient mixing than the HBSs.
- 2 December 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 31 (1) , 015006
Open AccessCurved passive mixing structures: a robust design to obtain efficient mixing and mass transfer in microfluidic channels
Analyte mixing and delivery to a functionalized sensor surface are important to realize several advantages associated with biosensors integrated with microfluidic channels. Here, we present a comparison between a herringbone structure (HBS) and a curved passive mixing structure of their efficiency at facilitating mixing and surface saturation using fluorescein included in one of the inlets of a Y-channel microfluidic device. We performed a large parametric study to assess the effects of varying the height of the microfluidic channel as well as the height, width, and spacing of the passive mixing structures. Scanning confocal microscopy combined with a custom-designed image-analysis procedure were utilized to visualize and quantify the observed changes in efficiency in inducing solute mixing by the different designs. The flow patterns within the channels were found to vary significantly with changes in the geometry of the passive mixing structures, which in turn affected the efficiency of the channel at mixing the fluid and saturating the surface opposite the mixing structures. The solute mixing as a function of the channel length was also determined; an initial slow mixing rate does not always coincide with a low mixing index (MI). We found that the range of MIs for the curved mixing structure 1 cm downstream from the inlet was 0.85–0.99 whilst for our HBS it was 0.74–0.98, depending on the design parameters of the passive mixing structures. Overall, this study shows that the curved passive mixing structure family is more robust in inducing efficient mixing than the HBSs.
- Open Access
- 24 November 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (24) , 4638-4639
Correction: A system for the high-throughput measurement of the shear modulus distribution of human red blood cells
Correction for ‘A system for the high-throughput measurement of the shear modulus distribution of human red blood cells’ by Amir Saadat et al., Lab Chip, 2020, 20, 2927–2936, DOI: 10.1039/D0LC00283F.
- 24 November 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (24) , 4638-4639
Open AccessCorrection: A system for the high-throughput measurement of the shear modulus distribution of human red blood cells
Correction for ‘A system for the high-throughput measurement of the shear modulus distribution of human red blood cells’ by Amir Saadat et al., Lab Chip, 2020, 20, 2927–2936, DOI: 10.1039/D0LC00283F.
- 22 June 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (16) , 2927-2936
A system for the high-throughput measurement of the shear modulus distribution of human red blood cells
Reduced deformability of red blood cells (RBCs) can affect the hemodynamics of the microcirculation and reduce oxygen transport efficiency. It is also well known that reduced RBC deformability is a signature of various physical disorders, including sepsis, and that the primary determinant of RBC deformability is the membrane shear modulus. To measure the distribution of an individual's RBC shear modulus with high throughput, we a) developed a high-fidelity computational model of RBCs in confined microchannels to inform design decisions; b) created a novel experimental system combining microfluidic flow, imaging, and image analysis; and c) performed automated comparisons between measured quantities and numerical predictions to extract quantitative measures of the RBC shear modulus for each of thousands of cells. We applied our computational simulation platform to construct the appropriate deformability figure(s) of merit to quantify RBC stiffness based on an experimentally measured, steady-state cell shape in flow through a microchannel. In particular, we determined a shape parameter based on the second moment of the cell shape that is sensitive to the changes in the membrane stiffness and cell size. We then conducted microfluidic experiments and developed custom automated image processing codes to identify and track the position and shape of individual RBCs within micro-constrictions. The fabricated microchannels include a square cross-section imaging region (7 by 7 μm) and we applied order 10 kPa pressure differences to induce order 10 mm s−1 cell velocities. The combination of modeling, microfluidics, and imaging enables, for the first time, quantitative measurement of the shear moduli of thousands of RBCs in human blood samples. We demonstrate the high-throughput features by sensitive quantification of the changes in the distribution of RBC stiffness with aging. This combined measurement and computational platform is ultimately intended to diagnose blood cell disorders in patients.
- 22 June 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (16) , 2927-2936
A system for the high-throughput measurement of the shear modulus distribution of human red blood cells
Reduced deformability of red blood cells (RBCs) can affect the hemodynamics of the microcirculation and reduce oxygen transport efficiency. It is also well known that reduced RBC deformability is a signature of various physical disorders, including sepsis, and that the primary determinant of RBC deformability is the membrane shear modulus. To measure the distribution of an individual's RBC shear modulus with high throughput, we a) developed a high-fidelity computational model of RBCs in confined microchannels to inform design decisions; b) created a novel experimental system combining microfluidic flow, imaging, and image analysis; and c) performed automated comparisons between measured quantities and numerical predictions to extract quantitative measures of the RBC shear modulus for each of thousands of cells. We applied our computational simulation platform to construct the appropriate deformability figure(s) of merit to quantify RBC stiffness based on an experimentally measured, steady-state cell shape in flow through a microchannel. In particular, we determined a shape parameter based on the second moment of the cell shape that is sensitive to the changes in the membrane stiffness and cell size. We then conducted microfluidic experiments and developed custom automated image processing codes to identify and track the position and shape of individual RBCs within micro-constrictions. The fabricated microchannels include a square cross-section imaging region (7 by 7 μm) and we applied order 10 kPa pressure differences to induce order 10 mm s−1 cell velocities. The combination of modeling, microfluidics, and imaging enables, for the first time, quantitative measurement of the shear moduli of thousands of RBCs in human blood samples. We demonstrate the high-throughput features by sensitive quantification of the changes in the distribution of RBC stiffness with aging. This combined measurement and computational platform is ultimately intended to diagnose blood cell disorders in patients.