Nahmil Koo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nahmil Koo has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Chisung Bae
Samsung Advanced Institute of Technology (SAIT), Suwon-si, Gyeonggi-do, South Korea
2 shared publications- SeongHwan Cho
Korea Advanced Institute of Science and Technology (KAIST)
2 shared publications Anes Ju
Samsung Advanced Institute of Technology (SAIT), Suwon-si, Gyeonggi-do, South Korea
1 shared publication- Byungsu Jung
Samsung Advanced Institute of Technology (SAIT), Suwon-si, Gyeonggi-do, South Korea
1 shared publication - Chang-Woo Shin
Samsung Advanced Institute of Technology (SAIT), Suwon-si, Gyeonggi-do, South Korea
1 shared publication - Dong-Jin Chang
Chungnam National University
1 shared publication
Latest Publications
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (1) , 3-14
Common-Mode Interference in Biopotential Amplifiers: Modeling, Analysis, and Design Strategies for Various Recording Setups
This review provides a comprehensive overview of techniques for mitigating common-mode interference (CMI) in biopotential analog front-ends (AFEs). The mechanisms of CMI generation in various biopotential measurement scenarios, including neurostimulation and two-electrode ECG, are modeled electrically. The impact of CMI on signal quality is analyzed from both small-signal and large-signal views, highlighting the scenario-dependent nature of the CMI issue. Techniques for improving the common-mode rejection ratio (CMRR) are introduced to suppress CMI in small-signal conditions. The concept of total CMRR (TCMRR), which incorporates the effect of asymmetric contact impedance, is reviewed, and corresponding design strategies for maximizing TCMRR are analyzed. In the large-signal view, CMI-induced distortion and approaches for enhancing tolerance CMI are discussed, addressing both sub-supply and over-supply CMI scenarios. By analyzing mitigation techniques across different measurement contexts, this review offers practical design insights to guide future biopotential AFE designers in selecting the most appropriate solutions.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 20 (1) , 3-14
Common-Mode Interference in Biopotential Amplifiers: Modeling, Analysis, and Design Strategies for Various Recording Setups
This review provides a comprehensive overview of techniques for mitigating common-mode interference (CMI) in biopotential analog front-ends (AFEs). The mechanisms of CMI generation in various biopotential measurement scenarios, including neurostimulation and two-electrode ECG, are modeled electrically. The impact of CMI on signal quality is analyzed from both small-signal and large-signal views, highlighting the scenario-dependent nature of the CMI issue. Techniques for improving the common-mode rejection ratio (CMRR) are introduced to suppress CMI in small-signal conditions. The concept of total CMRR (TCMRR), which incorporates the effect of asymmetric contact impedance, is reviewed, and corresponding design strategies for maximizing TCMRR are analyzed. In the large-signal view, CMI-induced distortion and approaches for enhancing tolerance CMI are discussed, addressing both sub-supply and over-supply CMI scenarios. By analyzing mitigation techniques across different measurement contexts, this review offers practical design insights to guide future biopotential AFE designers in selecting the most appropriate solutions.
- Open Access
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 23359-23370
Design of Low Power and Low Noise Instrumentation Amplifier for Biopotential Acquisition: A Review
This paper presents a comprehensive review of amplifier design techniques for biomedical sensor implementation focusing on Capacitively Coupled Instrumentation Amplifier (CCIA). The study covers the definition of the biosignal measurement environment, examining factors that affect intrinsic noise and low noise amplifier design techniques. It analyzes the causes of input impedance reduction and explores associated boosting techniques. The sources of half-cell potential are investigated, along with DC servo loops (DSL) and methods for improving their settling time and noise performance. Through an analysis of various issues related to biopotential measurement and a state-of-the-art survey, this paper aims to provide valuable insights for the design and advancement of Instrumentation Amplifiers (IA) for IoT and biopotential measurement.
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 23359-23370
Open AccessDesign of Low Power and Low Noise Instrumentation Amplifier for Biopotential Acquisition: A Review
This paper presents a comprehensive review of amplifier design techniques for biomedical sensor implementation focusing on Capacitively Coupled Instrumentation Amplifier (CCIA). The study covers the definition of the biosignal measurement environment, examining factors that affect intrinsic noise and low noise amplifier design techniques. It analyzes the causes of input impedance reduction and explores associated boosting techniques. The sources of half-cell potential are investigated, along with DC servo loops (DSL) and methods for improving their settling time and noise performance. Through an analysis of various issues related to biopotential measurement and a state-of-the-art survey, this paper aims to provide valuable insights for the design and advancement of Instrumentation Amplifiers (IA) for IoT and biopotential measurement.
- Open Access
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 175742-175751
A Hybrid Equalizer for Protection of 1st-Order Delta-Sigma Modulator Against Side-Channel Attack
This article introduces a countermeasure against Side-Channel Attacks (SCA) designed for 1st-order Delta-Sigma Modulators (DSM). Initially, the operation of 1st-Order DSM is explained at both the model and circuit levels. The analysis then focuses on the charging and discharging processes of internal capacitors, which lead to a signal-dependent charge transfer through the supply. The susceptibility of DSM to side-channel attacks is identified, and a neural network-based SCA method tailored for DSM is proposed. To safeguard the DSM from SCA, a hybrid equalizer circuit is developed, which mitigates the Current-Domain Signature (CDS) of the DSM’s supply current. This hybrid equalizer protects the DSM by absorbing the CDS using a switched capacitor equalizer, while ensuring continuous operation of DSM through a step-down charge pump and static current source. It is demonstrated that the hybrid equalizer circuit effectively defends against SCA by introducing substantial noise into the prediction output, without significantly compromising the DSM’s signal quality.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 175742-175751
Open AccessA Hybrid Equalizer for Protection of 1st-Order Delta-Sigma Modulator Against Side-Channel Attack
This article introduces a countermeasure against Side-Channel Attacks (SCA) designed for 1st-order Delta-Sigma Modulators (DSM). Initially, the operation of 1st-Order DSM is explained at both the model and circuit levels. The analysis then focuses on the charging and discharging processes of internal capacitors, which lead to a signal-dependent charge transfer through the supply. The susceptibility of DSM to side-channel attacks is identified, and a neural network-based SCA method tailored for DSM is proposed. To safeguard the DSM from SCA, a hybrid equalizer circuit is developed, which mitigates the Current-Domain Signature (CDS) of the DSM’s supply current. This hybrid equalizer protects the DSM by absorbing the CDS using a switched capacitor equalizer, while ensuring continuous operation of DSM through a step-down charge pump and static current source. It is demonstrated that the hybrid equalizer circuit effectively defends against SCA by introducing substantial noise into the prediction output, without significantly compromising the DSM’s signal quality.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 6, 109-112
A 16-Channel Impedance-Readout IC With Synchronous Sampling and Baseline Cancelation for Fast Neural Electrical Impedance Tomography
Fast neural electrical impedance tomography (EIT) is a promising method to not only record neural activities but also to localize them in peripheral nerves in a minimally invasive way. A much higher image frame rate is required for this application than conventional impedance measurement applications, which generally adopt the I/Q demodulation technique. To achieve a high enough frame rate to capture neural activities along the peripheral nerve fascicle, this paper proposes synchronous sampling (SS) and fast baseline tracking based on successive approximation (SA). The SS method needs an injection of only a single or a few periods of square-wave current signal for the amplitude measurement by synchronously sampling the received voltage signal. The proposed SA-based baseline tracking provides fast signal recovery from unwanted motion artifacts or baseline drifts. The designed readout circuit uses a two-step conversion where its coarse bits are generated from a current-based baseline cancellation circuit and its fine bits from a following SAR ADC. Thanks to the baseline tracking based on the SS and SA, the proposed IC achieves a faster frame rate of 312 fps with continuous baseline update and 500 fps with constant baseline compared to state-of-the-art works. The implemented IC is validated by measuring a water-filled tank and reconstructing its tomographic image. The results show successful discrimination of varied impedance areas over the tank.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 6, 109-112
A 16-Channel Impedance-Readout IC With Synchronous Sampling and Baseline Cancelation for Fast Neural Electrical Impedance Tomography
Fast neural electrical impedance tomography (EIT) is a promising method to not only record neural activities but also to localize them in peripheral nerves in a minimally invasive way. A much higher image frame rate is required for this application than conventional impedance measurement applications, which generally adopt the I/Q demodulation technique. To achieve a high enough frame rate to capture neural activities along the peripheral nerve fascicle, this paper proposes synchronous sampling (SS) and fast baseline tracking based on successive approximation (SA). The SS method needs an injection of only a single or a few periods of square-wave current signal for the amplitude measurement by synchronously sampling the received voltage signal. The proposed SA-based baseline tracking provides fast signal recovery from unwanted motion artifacts or baseline drifts. The designed readout circuit uses a two-step conversion where its coarse bits are generated from a current-based baseline cancellation circuit and its fine bits from a following SAR ADC. Thanks to the baseline tracking based on the SS and SA, the proposed IC achieves a faster frame rate of 312 fps with continuous baseline update and 500 fps with constant baseline compared to state-of-the-art works. The implemented IC is validated by measuring a water-filled tank and reconstructing its tomographic image. The results show successful discrimination of varied impedance areas over the tank.
- 7 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (2) , 508-519
A 43.3-μW Biopotential Amplifier With Tolerance to Common-Mode Interference of 18 Vpp and T-CMRR of 105 dB in 180-nm CMOS
In this article, we present an electrocardiogram (ECG) amplifier that has a large total CMRR (TCMRR) regardless of contact impedance mismatch and a large tolerance to common-mode interference (CMI). To achieve these features, an adaptive TCMRR enhancing loop is implemented in parallel with a charge-pump-based common-mode suppressing loop (CMSL). It adjusts the CMI current through each contact impedance so that common-mode (CM) to differential-mode (DM) conversion is minimized. We also propose a fast settling technique for the adaptive loop so that contact impedance variation can be tracked fast enough to allow robust ECG acquisition. A prototype chip fabricated in 180-nm CMOS achieves TCMRR larger than 105 dB even when there is contact impedance mismatch of up to 30%. It also achieves tolerance to CMI of 18 VPP at 60 Hz and input-referred noise of 1.90 ${\mu }\rm V_{rms}$ while consuming 43.3 $\mu \text{W}$ .
- 7 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (2) , 508-519
A 43.3-μW Biopotential Amplifier With Tolerance to Common-Mode Interference of 18 Vpp and T-CMRR of 105 dB in 180-nm CMOS
In this article, we present an electrocardiogram (ECG) amplifier that has a large total CMRR (TCMRR) regardless of contact impedance mismatch and a large tolerance to common-mode interference (CMI). To achieve these features, an adaptive TCMRR enhancing loop is implemented in parallel with a charge-pump-based common-mode suppressing loop (CMSL). It adjusts the CMI current through each contact impedance so that common-mode (CM) to differential-mode (DM) conversion is minimized. We also propose a fast settling technique for the adaptive loop so that contact impedance variation can be tracked fast enough to allow robust ECG acquisition. A prototype chip fabricated in 180-nm CMOS achieves TCMRR larger than 105 dB even when there is contact impedance mismatch of up to 30%. It also achieves tolerance to CMI of 18 VPP at 60 Hz and input-referred noise of 1.90 ${\mu }\rm V_{rms}$ while consuming 43.3 $\mu \text{W}$ .
- 8 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (2) , 591-600
A 24.8-μW Biopotential Amplifier Tolerant to 15-VPP Common-Mode Interference for Two-Electrode ECG Recording in 180-nm CMOS
This article presents a biopotential amplifier that has a large tolerance to common-mode interference (CMI) for a reliable two-electrode electrocardiogram (ECG) recording. To withstand large CMI without affecting the ECG signal, a common-mode charge pump (CMCP) that absorbs displacement current from the CMI and keeps the common-mode input within the desired range is proposed. This article also analyzes the effects of CMCP under non-ideal conditions and provides design guidelines for improved signal quality. A prototype chip fabricated in 180-nm CMOS achieves CMI tolerance of 15 VPP at 60 Hz while consuming 24.8 μW from a 1.2-V supply.
- 8 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 56 (2) , 591-600
A 24.8-μW Biopotential Amplifier Tolerant to 15-VPP Common-Mode Interference for Two-Electrode ECG Recording in 180-nm CMOS
This article presents a biopotential amplifier that has a large tolerance to common-mode interference (CMI) for a reliable two-electrode electrocardiogram (ECG) recording. To withstand large CMI without affecting the ECG signal, a common-mode charge pump (CMCP) that absorbs displacement current from the CMI and keeps the common-mode input within the desired range is proposed. This article also analyzes the effects of CMCP under non-ideal conditions and provides design guidelines for improved signal quality. A prototype chip fabricated in 180-nm CMOS achieves CMI tolerance of 15 VPP at 60 Hz while consuming 24.8 μW from a 1.2-V supply.