Borys B. Kravchuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Borys B. Kravchuk has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Eugene O. Perepeka
National Amosov Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine, Kyiv, Ukraine
10 shared publications - Maryna M. Sychyk
National Amosov Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine, Kyiv, Ukraine; National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, Kyiv, Ukraine
7 shared publications - Vasyl V. Lazoryshynets
Department of Surgery University of Florida Gainesville Florida US
3 shared publications - Bogdan Batsak
National Scientific Center «M.D. Strazhesko Institute of Cardiology, Clinical and Regenerative Medicine» of NAMS ofUkraine, Kyiv, Ukraine
2 shared publications - Dmytro A. Tymoshenko
National Amosov Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine, Kyiv, Ukraine
2 shared publications - Pavlo O. Almiz
National Amosov Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine, Kyiv, Ukraine
2 shared publications
Latest Publications
- Open Access
- 30 September 2026
- Published by National Institute of Cardiovascular Surgery named after M.M. Amosov of the NAMS of Ukraine in Ukrainian journal of cardiovascular surgery
- Vol. 34 (3) , 76-82
Pulsed Field Ablation of the Cavotricuspid Isthmus During Pulmonary Vein Isolation: Efficacy, Safety, and Procedure Duration
Pulsed field ablation (PFA) is a non-thermal technology that has rapidly entered the practice of catheter treatment of atrial fibrillation (AF) owing to its tissue selectivity and short application time. Its use for cavotricuspid isthmus (CTI) ablation in concomitant atrial flutter is less well studied.Аim. To assess the efficacy, safety and duration of pulsed field ablation of the CTI performed during pulmonary vein isolation (PVI) in patients with AF.Materials and methods. Data from 285 patients with AF who underwent catheter ablation using PFA were analyzed. CTI ablation was performed in 133 (46.7%) patients: radiofrequency (RFA) in 85 (63.9%), pulsed field in 36 (27.1%), and hybrid in 12 (9.0%). Achievement of bidirectional block, procedure duration, number of applications, and complications were assessed.Results. Pulsed field ablation of the CTI achieved bidirectional block in all cases with a median of 6 applications (interquartile range 6-8). The total procedure time in the PFA CTI group was significantly shorter than with RFA: median 52 versus 72 minutes (p<0.001). No serious complications occurred; one case of transient right coronary artery spasm was successfully resolved by intravenous nitrate administration. In hybrid ablation, the RFA → PFA sequence predominated (7 of 12), whereas the reverse transition was less frequent.Conclusions. Pulsed field ablation of the CTI during PVI is an effective and safe method that achieves bidirectional block with few applications and substantially shortens procedure duration compared with radiofrequency ablation.
- 30 September 2026
- Published by National Institute of Cardiovascular Surgery named after M.M. Amosov of the NAMS of Ukraine in Ukrainian journal of cardiovascular surgery
- Vol. 34 (3) , 76-82
Open AccessPulsed Field Ablation of the Cavotricuspid Isthmus During Pulmonary Vein Isolation: Efficacy, Safety, and Procedure Duration
Pulsed field ablation (PFA) is a non-thermal technology that has rapidly entered the practice of catheter treatment of atrial fibrillation (AF) owing to its tissue selectivity and short application time. Its use for cavotricuspid isthmus (CTI) ablation in concomitant atrial flutter is less well studied.Аim. To assess the efficacy, safety and duration of pulsed field ablation of the CTI performed during pulmonary vein isolation (PVI) in patients with AF.Materials and methods. Data from 285 patients with AF who underwent catheter ablation using PFA were analyzed. CTI ablation was performed in 133 (46.7%) patients: radiofrequency (RFA) in 85 (63.9%), pulsed field in 36 (27.1%), and hybrid in 12 (9.0%). Achievement of bidirectional block, procedure duration, number of applications, and complications were assessed.Results. Pulsed field ablation of the CTI achieved bidirectional block in all cases with a median of 6 applications (interquartile range 6-8). The total procedure time in the PFA CTI group was significantly shorter than with RFA: median 52 versus 72 minutes (p<0.001). No serious complications occurred; one case of transient right coronary artery spasm was successfully resolved by intravenous nitrate administration. In hybrid ablation, the RFA → PFA sequence predominated (7 of 12), whereas the reverse transition was less frequent.Conclusions. Pulsed field ablation of the CTI during PVI is an effective and safe method that achieves bidirectional block with few applications and substantially shortens procedure duration compared with radiofrequency ablation.
- Open Access
- 31 August 2026
- Published by Chetverta Khvylia in Ukrainian Journal of Cardiology
- Vol. 33 (4) , 48-55
Абляція імпульсним полем при фібриляції передсердь: інтрапроцедурні характеристики та профіль безпечності
Абляція імпульсним полем (АІП) – нетермальна технологія катетерного лікування фібриляції передсердь (ФП), що забезпечує тканинну селективність та потенційно вищий профіль безпечності порівняно з термальними методами. Дані щодо інтрапроцедурних характеристик та безпечності АІП у реальній клінічній практиці продовжують накопичуватися.Мета роботи – проаналізувати інтрапроцедурні характеристики та профіль безпечності абляції імпульсним полем у пацієнтів із фібриляцією передсердь та іншими передсердними тахіаритміями.Матеріали і методи. Ретроспективно проаналізовано дані 285 пацієнтів, яким виконували катетерну абляцію із застосуванням технології абляції імпульсним полем у ДУ «Національний науковий центр серцево-судинної хірургії та судинної патології імені М.М. Амосова НАМН України». Оцінювали клінічні характеристики, тривалість втручання, час перебування в лівому передсерді, кількість аплікацій, обсяг додаткових ліній абляції та інтра- і перипроцедурні ускладнення. Результати. З проаналізованої когорти первинний діагноз ФП мали 277 (97,2 %) пацієнтів: пароксизмальну форму – 170 (59,6 %), персистентну – 87 (30,5 %), тривалоперсистентну – 20 (7,0 %). Тривалість втручання, час у лівому передсерді та кількість аплікацій закономірно зростали від пароксизмальної до тривалоперсистентної форми (усі p<0,001). Частота застосування додаткових ліній суттєво збільшувалася зі зростанням тривалості аритмії: 11,2 %, 59,8 % та 85,0 % відповідно (p<0,001). Значущі ускладнення зафіксовано у 4 (1,4 %) пацієнтів, з яких специфічним для абляції імпульсним полем був 1 (0,35 %) випадок транзиторного спазму правої коронарної артерії. Не зареєстровано жодного випадку гострого пошкодження нирок внаслідок гемолізу, стенозу легеневих вен або ушкодження діафрагмального нерва.Висновки. Абляція імпульсним полем при ФП має сприятливий профіль безпечності з мінімальною часткою специфічних для застосування цього джерела енергії ускладнень. Час втручання зростає зі збільшенням обсягу субстратної абляції при більш тривалих формах аритмії.
- 31 August 2026
- Published by Chetverta Khvylia in Ukrainian Journal of Cardiology
- Vol. 33 (4) , 48-55
Open AccessАбляція імпульсним полем при фібриляції передсердь: інтрапроцедурні характеристики та профіль безпечності
Абляція імпульсним полем (АІП) – нетермальна технологія катетерного лікування фібриляції передсердь (ФП), що забезпечує тканинну селективність та потенційно вищий профіль безпечності порівняно з термальними методами. Дані щодо інтрапроцедурних характеристик та безпечності АІП у реальній клінічній практиці продовжують накопичуватися.Мета роботи – проаналізувати інтрапроцедурні характеристики та профіль безпечності абляції імпульсним полем у пацієнтів із фібриляцією передсердь та іншими передсердними тахіаритміями.Матеріали і методи. Ретроспективно проаналізовано дані 285 пацієнтів, яким виконували катетерну абляцію із застосуванням технології абляції імпульсним полем у ДУ «Національний науковий центр серцево-судинної хірургії та судинної патології імені М.М. Амосова НАМН України». Оцінювали клінічні характеристики, тривалість втручання, час перебування в лівому передсерді, кількість аплікацій, обсяг додаткових ліній абляції та інтра- і перипроцедурні ускладнення. Результати. З проаналізованої когорти первинний діагноз ФП мали 277 (97,2 %) пацієнтів: пароксизмальну форму – 170 (59,6 %), персистентну – 87 (30,5 %), тривалоперсистентну – 20 (7,0 %). Тривалість втручання, час у лівому передсерді та кількість аплікацій закономірно зростали від пароксизмальної до тривалоперсистентної форми (усі p<0,001). Частота застосування додаткових ліній суттєво збільшувалася зі зростанням тривалості аритмії: 11,2 %, 59,8 % та 85,0 % відповідно (p<0,001). Значущі ускладнення зафіксовано у 4 (1,4 %) пацієнтів, з яких специфічним для абляції імпульсним полем був 1 (0,35 %) випадок транзиторного спазму правої коронарної артерії. Не зареєстровано жодного випадку гострого пошкодження нирок внаслідок гемолізу, стенозу легеневих вен або ушкодження діафрагмального нерва.Висновки. Абляція імпульсним полем при ФП має сприятливий профіль безпечності з мінімальною часткою специфічних для застосування цього джерела енергії ускладнень. Час втручання зростає зі збільшенням обсягу субстратної абляції при більш тривалих формах аритмії.
- Open Access
- 28 March 2026
- Published by National Institute of Cardiovascular Surgery named after M.M. Amosov of the NAMS of Ukraine in Ukrainian journal of cardiovascular surgery
- Vol. 34 (1)
Predictors of Arrhythmia Recurrence after Catheter Radiofrequency Pulmonary Vein Isolation in Patients with Paroxysmal and Persistent Atrial Fibrillation
Background. Catheter pulmonary vein isolation (PVI) is currently the main rhythm-control strategy in patients with symptomatic atrial fibrillation (AF) refractory to antiarrhythmic drug therapy, according to contemporary clinical guidelines. Given the increasing number of ablation procedures performed annually and the high demand for optimization of healthcare resources, the identification of reliable predictors of AF recurrence remains of particular clinical importance. Aim. To identify independent predictors of AF recurrence within control observation period after first-time catheter PVI. Materials and Methods. In this retrospective analysis, 70 consecutive patients who underwent catheter radiofrequency PVI at the State Institution “Amosov National Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine” between May 2022 and December 2024 were included to assess long-term outcomes and predictors of arrhythmia recurrence. Results. Patients who experienced recurrence had higher LVEF (59.48±5.26 % vs 55.36±9.35 %; p=0.027) and lower end-diastolic index (59.38±5.57 vs 67.2±9.69 mL/m²; p=0.019). The non-recurrence group had shorter R–R intervals (761.06±124.58 vs 874.14±141.17 ms; p=0.045) and higher heart rate (80.5±13.92 vs 69.93±12.08 bpm; p=0.045) at the end of the procedure. Procedure duration was longer in recurrence group (161.18±32.81 vs 113.33±23.2 min; p<0.001). Fibrosis on voltage mapping tended to be higher in recurrence group (1.64±1.21 vs 0.79±0.73; p=0.064). After a 20-minute waiting period, the absence of pulmonary vein (PV) reconnection was more frequent in the non-recurrence group (15/25 vs 7/18; p=0.003), whereas reconnection of two veins occurred exclusively in the recurrence group (7 patients). In multivariable regression analysis, procedure duration was the only independent predictor (B=0.08; OR=1.08; 95 % CI 1.01-1.16; p=0.033). Conclusions. AF recurrence after PVI was primarily associated with procedural instability, specifically intraprocedural pulmonary vein reconnection. Longer procedure duration – likely reflecting substrate complexity and/or technical challenges – was the only independent predictor.
- 28 March 2026
- Published by National Institute of Cardiovascular Surgery named after M.M. Amosov of the NAMS of Ukraine in Ukrainian journal of cardiovascular surgery
- Vol. 34 (1)
Open AccessPredictors of Arrhythmia Recurrence after Catheter Radiofrequency Pulmonary Vein Isolation in Patients with Paroxysmal and Persistent Atrial Fibrillation
Background. Catheter pulmonary vein isolation (PVI) is currently the main rhythm-control strategy in patients with symptomatic atrial fibrillation (AF) refractory to antiarrhythmic drug therapy, according to contemporary clinical guidelines. Given the increasing number of ablation procedures performed annually and the high demand for optimization of healthcare resources, the identification of reliable predictors of AF recurrence remains of particular clinical importance. Aim. To identify independent predictors of AF recurrence within control observation period after first-time catheter PVI. Materials and Methods. In this retrospective analysis, 70 consecutive patients who underwent catheter radiofrequency PVI at the State Institution “Amosov National Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine” between May 2022 and December 2024 were included to assess long-term outcomes and predictors of arrhythmia recurrence. Results. Patients who experienced recurrence had higher LVEF (59.48±5.26 % vs 55.36±9.35 %; p=0.027) and lower end-diastolic index (59.38±5.57 vs 67.2±9.69 mL/m²; p=0.019). The non-recurrence group had shorter R–R intervals (761.06±124.58 vs 874.14±141.17 ms; p=0.045) and higher heart rate (80.5±13.92 vs 69.93±12.08 bpm; p=0.045) at the end of the procedure. Procedure duration was longer in recurrence group (161.18±32.81 vs 113.33±23.2 min; p<0.001). Fibrosis on voltage mapping tended to be higher in recurrence group (1.64±1.21 vs 0.79±0.73; p=0.064). After a 20-minute waiting period, the absence of pulmonary vein (PV) reconnection was more frequent in the non-recurrence group (15/25 vs 7/18; p=0.003), whereas reconnection of two veins occurred exclusively in the recurrence group (7 patients). In multivariable regression analysis, procedure duration was the only independent predictor (B=0.08; OR=1.08; 95 % CI 1.01-1.16; p=0.033). Conclusions. AF recurrence after PVI was primarily associated with procedural instability, specifically intraprocedural pulmonary vein reconnection. Longer procedure duration – likely reflecting substrate complexity and/or technical challenges – was the only independent predictor.
- Open Access
- 25 June 2025
- Published by National Institute of Cardiovascular Surgery named after M.M. Amosov of the NAMS of Ukraine in Ukrainian journal of cardiovascular surgery
- Vol. 33 (2) , 62-69
Assessment of the Degree of Left Atrial Fibrosis in Patients with Different Forms of Atrial Fibrillation
Atrial fibrillation (AF) is the most common type of cardiac arrhythmia, which has a significant impact on the health of patients worldwide. Left atrial fibrosis (LAF) is considered an irreversible form of remodeling that occurs in response to inflammation, stretching, or overload of the left atrium. The prevalence and degree of LAF may be associated with the prognosis and treatment outcomes after catheter ablation. Aim. To determine whether the degree of left atrial fibrosis is associated with the progression of atrial fibrillation. Materials and methods. During the period from January 2023 to December 2024, the State Research Institute of Cardiology named after M.M. Amosov National Academy of Medical Sciences of Ukraine performed 58 MRI studies with late contrast enhancement with gadolinium to study the degree of fibrosis of different chambers of the heart. Thirty-six of these patients were diagnosed with AF. In 12 patients, catheter ablation for atrial fibrillation was subsequently performed (radiofrequency, cryoballoon ablation, or pulsed field ablation). In 10, an attempt at electrical cardioversion without catheter intervention was performed. Results. Among the 34 patients included in the study, 13 (38 %) had paroxysmal AF, 14 (41 %) had persistent AF, and 7 (21 %) had permanent AF. Among the patients with paroxysmal AF, 9 (69 %) had stage I of left atrial fibrosis (LAF), 4 (31 %) had LAF stage II. No patients with LAF stage III-IV were observed in the paroxysmal AF group. In the persistent AF group (n = 14, 41 %), LAF stage I was observed in 4 (29 %) patients, LAF stage II in 8 (57 %), and LAF stage III and IV in 1 (7 %) patient in each group. In the patients with permanent AF (n = 7, 21 %), no patients with LAF stage I were observed. LAF stage II was observed in 4 (57 %) patients, LAF stage III in 2 (28 %), and LAF stage IV in 1 (14 %). The analysis showed a statistically significant decrease in left ventricular ejection fraction in patients with progressive AF. In the paroxysmal group, the mean LVEF was 55.75 ± 11.05 %, while in patients with persistent AF it decreased to 47.46 ± 13.88 %, and in chronic AF it decreased to 36.29 ± 12.08 % (p = 0.018). Conclusions. According to our results, the degree of fibrosis of the left atrium correlates with the stage of progression of atrial fibrillation.
- 25 June 2025
- Published by National Institute of Cardiovascular Surgery named after M.M. Amosov of the NAMS of Ukraine in Ukrainian journal of cardiovascular surgery
- Vol. 33 (2) , 62-69
Open AccessAssessment of the Degree of Left Atrial Fibrosis in Patients with Different Forms of Atrial Fibrillation
Atrial fibrillation (AF) is the most common type of cardiac arrhythmia, which has a significant impact on the health of patients worldwide. Left atrial fibrosis (LAF) is considered an irreversible form of remodeling that occurs in response to inflammation, stretching, or overload of the left atrium. The prevalence and degree of LAF may be associated with the prognosis and treatment outcomes after catheter ablation. Aim. To determine whether the degree of left atrial fibrosis is associated with the progression of atrial fibrillation. Materials and methods. During the period from January 2023 to December 2024, the State Research Institute of Cardiology named after M.M. Amosov National Academy of Medical Sciences of Ukraine performed 58 MRI studies with late contrast enhancement with gadolinium to study the degree of fibrosis of different chambers of the heart. Thirty-six of these patients were diagnosed with AF. In 12 patients, catheter ablation for atrial fibrillation was subsequently performed (radiofrequency, cryoballoon ablation, or pulsed field ablation). In 10, an attempt at electrical cardioversion without catheter intervention was performed. Results. Among the 34 patients included in the study, 13 (38 %) had paroxysmal AF, 14 (41 %) had persistent AF, and 7 (21 %) had permanent AF. Among the patients with paroxysmal AF, 9 (69 %) had stage I of left atrial fibrosis (LAF), 4 (31 %) had LAF stage II. No patients with LAF stage III-IV were observed in the paroxysmal AF group. In the persistent AF group (n = 14, 41 %), LAF stage I was observed in 4 (29 %) patients, LAF stage II in 8 (57 %), and LAF stage III and IV in 1 (7 %) patient in each group. In the patients with permanent AF (n = 7, 21 %), no patients with LAF stage I were observed. LAF stage II was observed in 4 (57 %) patients, LAF stage III in 2 (28 %), and LAF stage IV in 1 (14 %). The analysis showed a statistically significant decrease in left ventricular ejection fraction in patients with progressive AF. In the paroxysmal group, the mean LVEF was 55.75 ± 11.05 %, while in patients with persistent AF it decreased to 47.46 ± 13.88 %, and in chronic AF it decreased to 36.29 ± 12.08 % (p = 0.018). Conclusions. According to our results, the degree of fibrosis of the left atrium correlates with the stage of progression of atrial fibrillation.
- Open Access
- 28 April 2025
- Published by Chetverta Khvylia in Ukrainian Journal of Cardiology
- Vol. 32 (2) , 54-66
Методи ресинхронізаційної терапії в пацієнтів із серцевою недостатністю і порушеннями внутрішньошлуночкової провідності
Cardiac resynchronization therapy is an effective treatment method for patients with intraventricular conduction disturbances combined with heart failure and left ventricular systolic dysfunction. The mechanism of resynchronization therapy lies in restoring atrioventricular, intraventricular, and interventricular synchrony, which leads to coordinated ventricular function and improvement in ventricular systolic performance. There are two main methods of resynchronization therapy: biventricular pacing and conduction system pacing. Significant attention is being devoted to conduction system pacing, a relatively new technique that has shown promising results. By many criteria, conduction system pacing, particularly left bundle branch pacing, even surpasses biventricular pacing, which may significantly increase its importance in the near future. In some cases, to achieve better resynchronization effect, methods for resynchronization therapy optimization have been used. These methods involve simultaneous pacing in different loci, as well as the combination of biventricular pacing and conduction system pacing (LOT-CRT, HOT-CRT). This review analyzes the clinical aspects and features of both techniques, along with the advantages and disadvantages of each resynchronization approach.
- 28 April 2025
- Published by Chetverta Khvylia in Ukrainian Journal of Cardiology
- Vol. 32 (2) , 54-66
Open AccessМетоди ресинхронізаційної терапії в пацієнтів із серцевою недостатністю і порушеннями внутрішньошлуночкової провідності
Cardiac resynchronization therapy is an effective treatment method for patients with intraventricular conduction disturbances combined with heart failure and left ventricular systolic dysfunction. The mechanism of resynchronization therapy lies in restoring atrioventricular, intraventricular, and interventricular synchrony, which leads to coordinated ventricular function and improvement in ventricular systolic performance. There are two main methods of resynchronization therapy: biventricular pacing and conduction system pacing. Significant attention is being devoted to conduction system pacing, a relatively new technique that has shown promising results. By many criteria, conduction system pacing, particularly left bundle branch pacing, even surpasses biventricular pacing, which may significantly increase its importance in the near future. In some cases, to achieve better resynchronization effect, methods for resynchronization therapy optimization have been used. These methods involve simultaneous pacing in different loci, as well as the combination of biventricular pacing and conduction system pacing (LOT-CRT, HOT-CRT). This review analyzes the clinical aspects and features of both techniques, along with the advantages and disadvantages of each resynchronization approach.
- Open Access
- 28 April 2025
- Published by Chetverta Khvylia in Ukrainian Journal of Cardiology
- Vol. 32 (2) , 67-74
Кардіонейроабляція в лікуванні вазовагального синкопе. Сьогодення та перспективи
The aim – considering worldwide experience, it is necessary to analyze scientific articles about ablation of ganglion plexi (GP) (cardioneuroabaltion) for patients with vasovagal syncope (VVS).Searching scientific articles was performed with well-known online-library PubMed. 203 articles were found in different scientific journals. The selection of patients is an essential factor during preprocedural period in order to predict results of cardioneuroablation. Ablation of ganglion plexi in both right and left atrium has showed the best effectiveness. Moreover, extracardiac vagal stimulation may be an advanced method to check acute results after parasympathetic denervation.The first article about treatment of VVS has been published by Pachon et al. in 2005, that presented the reduced rate of recurrent syncope after cardioneuroabaltion. Results of the first randomized clinical trial have been published by R. Piotrowski et al., in which 48 patients were enrolled and were divided into two groups of 24 patients respectively. Group, where cardioneuroablation was performed, has the decreased level of the recurrence syncope in contrast with group, where conservative therapy was introduced (8 % and 54 % respectively). The first randomized clinical trial comparing clinical impact between pacemaker implantation and cardioneuroablation have being started in 2024 (TELE-SPACER).Conclusions. The choosing of the appropriate method of treatment in patients with VVS is still discussed. Cardineuroablation may be become an effective and safe option especially in young people.
- 28 April 2025
- Published by Chetverta Khvylia in Ukrainian Journal of Cardiology
- Vol. 32 (2) , 67-74
Open AccessКардіонейроабляція в лікуванні вазовагального синкопе. Сьогодення та перспективи
The aim – considering worldwide experience, it is necessary to analyze scientific articles about ablation of ganglion plexi (GP) (cardioneuroabaltion) for patients with vasovagal syncope (VVS).Searching scientific articles was performed with well-known online-library PubMed. 203 articles were found in different scientific journals. The selection of patients is an essential factor during preprocedural period in order to predict results of cardioneuroablation. Ablation of ganglion plexi in both right and left atrium has showed the best effectiveness. Moreover, extracardiac vagal stimulation may be an advanced method to check acute results after parasympathetic denervation.The first article about treatment of VVS has been published by Pachon et al. in 2005, that presented the reduced rate of recurrent syncope after cardioneuroabaltion. Results of the first randomized clinical trial have been published by R. Piotrowski et al., in which 48 patients were enrolled and were divided into two groups of 24 patients respectively. Group, where cardioneuroablation was performed, has the decreased level of the recurrence syncope in contrast with group, where conservative therapy was introduced (8 % and 54 % respectively). The first randomized clinical trial comparing clinical impact between pacemaker implantation and cardioneuroablation have being started in 2024 (TELE-SPACER).Conclusions. The choosing of the appropriate method of treatment in patients with VVS is still discussed. Cardineuroablation may be become an effective and safe option especially in young people.
- Open Access
- 27 September 2024
- Published by Professional Edition Eastern Europe in Ukrainian journal of cardiovascular surgery
- Vol. 32 (3) , 66-72
Evaluation of the Results of Left Bundle Branch Pacing after Atrioventricular Junction Ablation in Patients with Chronic Atrial Fibrillation
Atrioventricular junction ablation (AVJA) together with the implantation of cardiac pacemaker has become a recognized and effective treatment strategy for patients with symptomatic tachysystolic atrial fibrillation that does not respond to heart rate control drug therapy. Left bundle branch pacing (LBBP) is a physiological alternative to right ventricular and biventricular pacing. The aim. To analyze the clinical results of the average duration with the use of LBBP and AVJA. Materials and methods. Over the period from January 2023 to July 2024, LBBP with subsequent AVJA was applied at the National Amosov Institute of Cardiovascular Surgery in 18 patients as a method of treatment of chronic tachysystolic atrial fibrillation to achieve heart rate control. Results. Mid-term results (at least 1 month) could be monitored in 15 out of 18 patients (84%); in the other three (16%) patients the time between pacemaker implantation and AVJA was too short. The mean period from pacemaker implantation to control examination was 5.07 ± 2.79 months (minimum period 1 month, maximum 12 months). During the period from implantation and ablation to the control observation in the study group, it was possible to observe an increase in left ventricular ejection fraction from 39.12 ± 10.56% to 46.38 ± 7.09%, p = 0.035; decrease in the values of end-diastolic volume from 184.22 ± 76.76 to 167.85 ± 36.93 ml, p = 0.074; decrease in the right ventricular pressure from 43.07 ± 8.29 to 34.38 ± 4.78 mm Hg, p = 0.013. It was also possible to observe a decrease in the left bundle branch capture thresholds from 1.27 ± 0.58 to 0.7 ± 0.39 V at 0.4 ms, p = 0.016; and a decrease in the average LBBP endocardial lead resistance from 638 ± 172.83 to 529.4 ± 120.15 Ohm, p = 0.012. Conclusions. Implantation of the LBBP pacemaker and AVJA was not associated with the occurrence of complications both in the intraoperative and postoperative periods, as well as in the remote period of the average duration in the studied group. The use of this approach in patients with chronic atrial fibrillation made it possible in a series of consecutive patients to improve the systolic function of the left ventricle, to reduce the values of the end-diastolic volume of the left ventricle and the right ventricular pressure at optimal pacing parameters.
- 27 September 2024
- Published by Professional Edition Eastern Europe in Ukrainian journal of cardiovascular surgery
- Vol. 32 (3) , 66-72
Open AccessEvaluation of the Results of Left Bundle Branch Pacing after Atrioventricular Junction Ablation in Patients with Chronic Atrial Fibrillation
Atrioventricular junction ablation (AVJA) together with the implantation of cardiac pacemaker has become a recognized and effective treatment strategy for patients with symptomatic tachysystolic atrial fibrillation that does not respond to heart rate control drug therapy. Left bundle branch pacing (LBBP) is a physiological alternative to right ventricular and biventricular pacing. The aim. To analyze the clinical results of the average duration with the use of LBBP and AVJA. Materials and methods. Over the period from January 2023 to July 2024, LBBP with subsequent AVJA was applied at the National Amosov Institute of Cardiovascular Surgery in 18 patients as a method of treatment of chronic tachysystolic atrial fibrillation to achieve heart rate control. Results. Mid-term results (at least 1 month) could be monitored in 15 out of 18 patients (84%); in the other three (16%) patients the time between pacemaker implantation and AVJA was too short. The mean period from pacemaker implantation to control examination was 5.07 ± 2.79 months (minimum period 1 month, maximum 12 months). During the period from implantation and ablation to the control observation in the study group, it was possible to observe an increase in left ventricular ejection fraction from 39.12 ± 10.56% to 46.38 ± 7.09%, p = 0.035; decrease in the values of end-diastolic volume from 184.22 ± 76.76 to 167.85 ± 36.93 ml, p = 0.074; decrease in the right ventricular pressure from 43.07 ± 8.29 to 34.38 ± 4.78 mm Hg, p = 0.013. It was also possible to observe a decrease in the left bundle branch capture thresholds from 1.27 ± 0.58 to 0.7 ± 0.39 V at 0.4 ms, p = 0.016; and a decrease in the average LBBP endocardial lead resistance from 638 ± 172.83 to 529.4 ± 120.15 Ohm, p = 0.012. Conclusions. Implantation of the LBBP pacemaker and AVJA was not associated with the occurrence of complications both in the intraoperative and postoperative periods, as well as in the remote period of the average duration in the studied group. The use of this approach in patients with chronic atrial fibrillation made it possible in a series of consecutive patients to improve the systolic function of the left ventricle, to reduce the values of the end-diastolic volume of the left ventricle and the right ventricular pressure at optimal pacing parameters.
- Open Access
- 27 June 2024
- Published by Professional Edition Eastern Europe in Ukrainian journal of cardiovascular surgery
- Vol. 32 (2) , 120-128
Minimizing Exposure to Ionizing Radiation in Catheter-Based Treatment of Atrial Fibrillation: Safety and Efficacy
Pulmonary vein isolation using radiofrequency ablation is the most common method of catheter treatment for atrial fibrillation. Performing this procedure involves the use of X-ray radiation, which at certain stages of the procedure is an indispensable method for navigation and visualization of intracardiac structures. Approaches to minimize X-ray exposure during catheter interventions are attracting increased attention of the electrophysiology community due to the potential risks of adverse effects of ionizing radiation on patients and medical personnel. The aim. To evaluate the effectiveness and safety of performing the pulmonary vein isolation procedure with the intention to minimize X-ray exposure of patients and medical personnel. Materials and methods. Forty-three patients with various forms of atrial fibrillation were selected for the study: 28(65%) with paroxysmal and 15 (35%) with persistent forms. All the patients underwent pulmonary vein isolation usingcatheter radiofrequency ablation with the intention to minimize X-ray exposure at the National Amosov Institute of Cardiovascular Surgery in the period from June 2023 to April 2024. Results. In all 43 patients it was possible to electrically isolate all the veins. Catheter ablation of the cavotricuspidisthmus was performed in 5 (31.2%) patients from group A (“Zero-fluoro”), 7 (33.3%) from group B (“Near Zero-fluoro”) and 3 (50%) from group C (“Non Zero-fluoro”) (p = 0.696). Intraoperative reconnection of the pulmonary veins with the left atrium was observed in 6 (37.5%) patients of group A, 11 (52.3%) of group B, and 4 (66%) of group C (p = 0.429). X-ray time for transseptal puncture did not differ between groups A and B (3.56 ± 2.37 vs. 3.69 ± 2.3 min., p = 0.532), however, X-ray time for pulmonary vein isolation in group A was significantly less than that in group B (0.27 ± 0.13 vs. 1.96 ± 1.21 min., p < 0.001). The total time in the left atrium was not statistically different between these two groups (81.33 ± 22.32 vs. 98.6 ± 29.83 min., p = 0.106). In group C (“Non Zero-fluoro”), the aforementioned parameters were not recorded. Total dose area product (DAP) and total radiation dose, as well as total X-ray time and total procedure time, were significantly lower when using the ionizing exposure minimization approach. DAP and total radiation dose in group A were the lowest (7.29 ± 5.16 Gy/cm2 and 76.62 ± 70.82 mGy, respectively) and significantly differed from those in group C (107.67 ± 97.59 Gy/cm2 and 882.32 ± 868.62 mGy, p < 0.001 and p = 0.001, respectively). No intraoperative complications were observed in the studied sample. Conclusions. Minimizing X-ray exposure using modern navigation systems during pulmonary vein isolation using catheter radiofrequency ablation is not associated with increased intraprocedural complications in patients with paroxysmal and persistent atrial fibrillation. This approach allows you to significantly lower total DAP and the radiation dosewithout increasing the time of performing the pulmonary vein isolation procedure.
- 27 June 2024
- Published by Professional Edition Eastern Europe in Ukrainian journal of cardiovascular surgery
- Vol. 32 (2) , 120-128
Open AccessMinimizing Exposure to Ionizing Radiation in Catheter-Based Treatment of Atrial Fibrillation: Safety and Efficacy
Pulmonary vein isolation using radiofrequency ablation is the most common method of catheter treatment for atrial fibrillation. Performing this procedure involves the use of X-ray radiation, which at certain stages of the procedure is an indispensable method for navigation and visualization of intracardiac structures. Approaches to minimize X-ray exposure during catheter interventions are attracting increased attention of the electrophysiology community due to the potential risks of adverse effects of ionizing radiation on patients and medical personnel. The aim. To evaluate the effectiveness and safety of performing the pulmonary vein isolation procedure with the intention to minimize X-ray exposure of patients and medical personnel. Materials and methods. Forty-three patients with various forms of atrial fibrillation were selected for the study: 28(65%) with paroxysmal and 15 (35%) with persistent forms. All the patients underwent pulmonary vein isolation usingcatheter radiofrequency ablation with the intention to minimize X-ray exposure at the National Amosov Institute of Cardiovascular Surgery in the period from June 2023 to April 2024. Results. In all 43 patients it was possible to electrically isolate all the veins. Catheter ablation of the cavotricuspidisthmus was performed in 5 (31.2%) patients from group A (“Zero-fluoro”), 7 (33.3%) from group B (“Near Zero-fluoro”) and 3 (50%) from group C (“Non Zero-fluoro”) (p = 0.696). Intraoperative reconnection of the pulmonary veins with the left atrium was observed in 6 (37.5%) patients of group A, 11 (52.3%) of group B, and 4 (66%) of group C (p = 0.429). X-ray time for transseptal puncture did not differ between groups A and B (3.56 ± 2.37 vs. 3.69 ± 2.3 min., p = 0.532), however, X-ray time for pulmonary vein isolation in group A was significantly less than that in group B (0.27 ± 0.13 vs. 1.96 ± 1.21 min., p < 0.001). The total time in the left atrium was not statistically different between these two groups (81.33 ± 22.32 vs. 98.6 ± 29.83 min., p = 0.106). In group C (“Non Zero-fluoro”), the aforementioned parameters were not recorded. Total dose area product (DAP) and total radiation dose, as well as total X-ray time and total procedure time, were significantly lower when using the ionizing exposure minimization approach. DAP and total radiation dose in group A were the lowest (7.29 ± 5.16 Gy/cm2 and 76.62 ± 70.82 mGy, respectively) and significantly differed from those in group C (107.67 ± 97.59 Gy/cm2 and 882.32 ± 868.62 mGy, p < 0.001 and p = 0.001, respectively). No intraoperative complications were observed in the studied sample. Conclusions. Minimizing X-ray exposure using modern navigation systems during pulmonary vein isolation using catheter radiofrequency ablation is not associated with increased intraprocedural complications in patients with paroxysmal and persistent atrial fibrillation. This approach allows you to significantly lower total DAP and the radiation dosewithout increasing the time of performing the pulmonary vein isolation procedure.
- Open Access
- 27 March 2024
- Published by Professional Edition Eastern Europe in Ukrainian journal of cardiovascular surgery
- Vol. 32 (1) , 70-75
The Effect of the Use of Activation 3D Mapping on the Patient X-Ray Load During Radiofrequency Ablation of Typical Atrial Flutter
Supraventricular macro re-entry tachyarrhythmias occupy the leading places among all types of tachyarrhythmias. The most common in this category is typical atrial flutter (AFL). This heart rhythm disorder has a negative impact on the patients’ quality of life. Its complications can lead to disability and death due to possible thromboembolism. Therapeutic treatment is limited in effectiveness. The main method of intervention is catheter radiofrequency ablation (RFA). The standard approach of RFA of AFL is performed without the use of navigation systems under fluoroscopy guidance. However, this results in an increased radiation exposure to the patient and the medical personnel. Modern technologies in the field of invasive electrophysiology make it possible to create anatomical models of heart and reproduce the spread of electrical excitation. However, the routine use of additional navigation methods remains controversial. The aim. To compare the duration of RFA of typical AFL and radiation exposure with the use of anatomical and propagation mapping. Materials and methods. This study is based on the analysis of the treatment results obtained for 53 patients at the National Amosov Institute of Cardiovascular Surgery in the period from 2014 to 2023. Depending on imaging methods, the patients were divided into two groups. The first group included 27 patients with an anatomical mapping of the right atrium. The second group included 26 patients with propagation mapping. Results. In all the patients we have achieved a bidirectional conduction block through cavotricuspid isthmus. In the first group, the total duration of confirming the diagnosis and creating the anatomical model was 312 ± 26 seconds. The mean time to the moment of AFL termination and restoration of sinus rhythm was 230 ± 19 seconds. The average duration of the procedure was 41.5 ± 3.5 minutes, the average fluoroscopy time was 120 ± 10 seconds, the average dose area product (DAP) was 15 ± 1.3 Gy·cm2. In the second group, the average time for creating a 3D propagation model of right atrium and verifying the diagnosis was 748 ± 65 seconds. The average time from the first application to the termination of tachycardia was 227 ± 20 seconds. The average duration of the procedure was 55 ± 4.7 minutes, X-ray time was 93 ± 8 seconds, average DAP was 13 ± 1.1 Gy·cm2. The duration of the procedure in the second group was significantly longer (p = 0.03), however, the radiation exposure and DAP were not statistically different (p = 0.31) between the observation groups. Conclusions. The use of propagation mapping increases the time of the procedure by 24.5% and does not give a significant advantage in reducing the radiation exposure. The use of a navigation system during cavotricuspid isthmus RFA is recommended for concomitant radical treatment of complex supraventricular arrhythmias, such as atrial fibrillation. Суправентрикулярні макрореентрі тахіаритмії займають провідні місця серед усіх видів тахіаритмій. Найпоширенішим у цій категорії є типове тріпотіння передсердь (ТП). Це порушення ритму серця справляє негативний вплив на якість життя пацієнтів. Ускладнення можуть призвести до інвалідизації та летальних наслідків через можливі тромбоемболії. Медикаментозне лікування ТП є обмеженим за ефективністю. Основним методом втручання є катетерна радіочастотна абляція (РЧА). Стандартно РЧА типового ТП виконують без використання систем навігації під контролем рентгеноскопії. Проте це призводить до підвищеного опромінення як пацієнта, так і медичного персоналу. Сучасні технології в інвазивній електрофізіології дозволяють створювати анатомічну модель серця і відтворювати поширення електричного збудження. Проте залишається відкритим питання доцільності рутинного використання додаткових методик навігації. Мета – порівняти показники тривалості РЧА типового ТП та променевого навантаження при використанні анатомічного та анатомо-активаційного картування. Матеріали та методи. Ця робота ґрунтується на аналізі результатів лікування 53 пацієнтів у Національному інституті серцево-судинної хірургії імені М. М. Амосова з 2014 по 2023 рік, яким проводили радіочастотну ізоляцію легеневих вен та симультанну абляцію тріпотіння передсердь. Анатомічне та активаційне картування ТП проводили в контрольний час після ізоляції легеневих вен. Залежно від методів візуалізації пацієнтів було розділено на дві групи. У групу І увійшли 27 пацієнтів, у яких створювали анатомічну модель правого передсердя. У групу ІІ – 26 пацієнтів, яким проводили анатомічне та активаційне...
- 27 March 2024
- Published by Professional Edition Eastern Europe in Ukrainian journal of cardiovascular surgery
- Vol. 32 (1) , 70-75
Open AccessThe Effect of the Use of Activation 3D Mapping on the Patient X-Ray Load During Radiofrequency Ablation of Typical Atrial Flutter
Supraventricular macro re-entry tachyarrhythmias occupy the leading places among all types of tachyarrhythmias. The most common in this category is typical atrial flutter (AFL). This heart rhythm disorder has a negative impact on the patients’ quality of life. Its complications can lead to disability and death due to possible thromboembolism. Therapeutic treatment is limited in effectiveness. The main method of intervention is catheter radiofrequency ablation (RFA). The standard approach of RFA of AFL is performed without the use of navigation systems under fluoroscopy guidance. However, this results in an increased radiation exposure to the patient and the medical personnel. Modern technologies in the field of invasive electrophysiology make it possible to create anatomical models of heart and reproduce the spread of electrical excitation. However, the routine use of additional navigation methods remains controversial. The aim. To compare the duration of RFA of typical AFL and radiation exposure with the use of anatomical and propagation mapping. Materials and methods. This study is based on the analysis of the treatment results obtained for 53 patients at the National Amosov Institute of Cardiovascular Surgery in the period from 2014 to 2023. Depending on imaging methods, the patients were divided into two groups. The first group included 27 patients with an anatomical mapping of the right atrium. The second group included 26 patients with propagation mapping. Results. In all the patients we have achieved a bidirectional conduction block through cavotricuspid isthmus. In the first group, the total duration of confirming the diagnosis and creating the anatomical model was 312 ± 26 seconds. The mean time to the moment of AFL termination and restoration of sinus rhythm was 230 ± 19 seconds. The average duration of the procedure was 41.5 ± 3.5 minutes, the average fluoroscopy time was 120 ± 10 seconds, the average dose area product (DAP) was 15 ± 1.3 Gy·cm2. In the second group, the average time for creating a 3D propagation model of right atrium and verifying the diagnosis was 748 ± 65 seconds. The average time from the first application to the termination of tachycardia was 227 ± 20 seconds. The average duration of the procedure was 55 ± 4.7 minutes, X-ray time was 93 ± 8 seconds, average DAP was 13 ± 1.1 Gy·cm2. The duration of the procedure in the second group was significantly longer (p = 0.03), however, the radiation exposure and DAP were not statistically different (p = 0.31) between the observation groups. Conclusions. The use of propagation mapping increases the time of the procedure by 24.5% and does not give a significant advantage in reducing the radiation exposure. The use of a navigation system during cavotricuspid isthmus RFA is recommended for concomitant radical treatment of complex supraventricular arrhythmias, such as atrial fibrillation. Суправентрикулярні макрореентрі тахіаритмії займають провідні місця серед усіх видів тахіаритмій. Найпоширенішим у цій категорії є типове тріпотіння передсердь (ТП). Це порушення ритму серця справляє негативний вплив на якість життя пацієнтів. Ускладнення можуть призвести до інвалідизації та летальних наслідків через можливі тромбоемболії. Медикаментозне лікування ТП є обмеженим за ефективністю. Основним методом втручання є катетерна радіочастотна абляція (РЧА). Стандартно РЧА типового ТП виконують без використання систем навігації під контролем рентгеноскопії. Проте це призводить до підвищеного опромінення як пацієнта, так і медичного персоналу. Сучасні технології в інвазивній електрофізіології дозволяють створювати анатомічну модель серця і відтворювати поширення електричного збудження. Проте залишається відкритим питання доцільності рутинного використання додаткових методик навігації. Мета – порівняти показники тривалості РЧА типового ТП та променевого навантаження при використанні анатомічного та анатомо-активаційного картування. Матеріали та методи. Ця робота ґрунтується на аналізі результатів лікування 53 пацієнтів у Національному інституті серцево-судинної хірургії імені М. М. Амосова з 2014 по 2023 рік, яким проводили радіочастотну ізоляцію легеневих вен та симультанну абляцію тріпотіння передсердь. Анатомічне та активаційне картування ТП проводили в контрольний час після ізоляції легеневих вен. Залежно від методів візуалізації пацієнтів було розділено на дві групи. У групу І увійшли 27 пацієнтів, у яких створювали анатомічну модель правого передсердя. У групу ІІ – 26 пацієнтів, яким проводили анатомічне та активаційне...
- Open Access
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Medical physics – the current status, problems, the way of development. Innovation technologies
- No. 1,p. 153-162
EFFECTIVE REDUCTION OF RADIATION EXPOSURE DURING CATHETER PROCEDURES THROUGH OPTIMIZATION OF THE ELECTROANATOMICAL MAPPING NAVIGATION SYSTEM AND PULMONARY VEIN ISOLATION PROCEDURE PROTOCOL
Introduction. Pulmonary vein isolation (PVI) through radiofrequency ablation (RFA) is the most common method of catheter-based treatment for atrial fibrillation (AF). Electrophysiologists are increasingly focusing on techniques that reduce the use of X-ray guidance during catheter procedures due to the potential risks of ionizing radiation to patients and medical staff. Methods. The aim of this scientific and clinical study is to assess the effectiveness and safety of catheter-based radiofrequency ablation for pulmonary vein isolation (PVI) while minimizing X-ray exposure through optimization of the electroanatomical mapping navigation system and procedural protocol. Results. The study included 43 patients with different forms of atrial fibrillation. All patients underwent catheter-based radiofrequency ablation for pulmonary vein isolation (PVI) with a focus on reducing X-ray exposure at the M.M. Amosov National Institute of Cardiovascular Surgery from June 2023 to April 2024. To achieve this, an optimized X-ray exposure protocol was used during phases requiring X-ray guidance, and predominantly electroanatomical navigation was employed after transseptal puncture. In all 43 patients, electrical isolation of all veins was successfully achieved. The use of methods to minimize X-ray exposure resulted in a significant reduction in the total dose area product (DAP), total radiation dose, X-ray usage time, and procedure duration compared to traditional approaches. The DAP and total radiation dose in Group A (“Zero-fluoro”) were the lowest (7.29 ± 5.16 Gy·cm² and 76.62 ± 70.82 mGy) and significantly differed from those in Group B (“Non Zero-fluoro”) (107.67 ± 97.59 Gy·cm² (p < 0.001) and 882.32 ± 868.62 mGy (p = 0.001)). Procedure duration was shorter in Groups A (“Zero-fluoro”) and Б (“Near Zero-fluoro”) (112.81 ± 30.16 minutes and 138.06 ± 33.44 minutes) compared to Group B (“Non Zero-fluoro”) (167 ± 43.53 minutes), with Group A (“Zero-fluoro”) having a significantly shorter duration compared to Group B (“Non Zero-fluoro”) (p = 0.014). No intraoperative complications were recorded in the sample. Conclusions. The use of advanced navigation systems to minimize X-ray exposure during catheter-based radiofrequency ablation for pulmonary vein isolation does not increase the risk of intraprocedural complications in patients with paroxysmal or persistent atrial fibrillation. This approach allows for a significant reduction in the total dose area product (DAP) and radiation dose without increasing the duration of the PVI procedure.
- 1 January 2024
- Published by Taras Shevchenko National University of Kyiv in Medical physics – the current status, problems, the way of development. Innovation technologies
- No. 1,p. 153-162
Open AccessEFFECTIVE REDUCTION OF RADIATION EXPOSURE DURING CATHETER PROCEDURES THROUGH OPTIMIZATION OF THE ELECTROANATOMICAL MAPPING NAVIGATION SYSTEM AND PULMONARY VEIN ISOLATION PROCEDURE PROTOCOL
Introduction. Pulmonary vein isolation (PVI) through radiofrequency ablation (RFA) is the most common method of catheter-based treatment for atrial fibrillation (AF). Electrophysiologists are increasingly focusing on techniques that reduce the use of X-ray guidance during catheter procedures due to the potential risks of ionizing radiation to patients and medical staff. Methods. The aim of this scientific and clinical study is to assess the effectiveness and safety of catheter-based radiofrequency ablation for pulmonary vein isolation (PVI) while minimizing X-ray exposure through optimization of the electroanatomical mapping navigation system and procedural protocol. Results. The study included 43 patients with different forms of atrial fibrillation. All patients underwent catheter-based radiofrequency ablation for pulmonary vein isolation (PVI) with a focus on reducing X-ray exposure at the M.M. Amosov National Institute of Cardiovascular Surgery from June 2023 to April 2024. To achieve this, an optimized X-ray exposure protocol was used during phases requiring X-ray guidance, and predominantly electroanatomical navigation was employed after transseptal puncture. In all 43 patients, electrical isolation of all veins was successfully achieved. The use of methods to minimize X-ray exposure resulted in a significant reduction in the total dose area product (DAP), total radiation dose, X-ray usage time, and procedure duration compared to traditional approaches. The DAP and total radiation dose in Group A (“Zero-fluoro”) were the lowest (7.29 ± 5.16 Gy·cm² and 76.62 ± 70.82 mGy) and significantly differed from those in Group B (“Non Zero-fluoro”) (107.67 ± 97.59 Gy·cm² (p < 0.001) and 882.32 ± 868.62 mGy (p = 0.001)). Procedure duration was shorter in Groups A (“Zero-fluoro”) and Б (“Near Zero-fluoro”) (112.81 ± 30.16 minutes and 138.06 ± 33.44 minutes) compared to Group B (“Non Zero-fluoro”) (167 ± 43.53 minutes), with Group A (“Zero-fluoro”) having a significantly shorter duration compared to Group B (“Non Zero-fluoro”) (p = 0.014). No intraoperative complications were recorded in the sample. Conclusions. The use of advanced navigation systems to minimize X-ray exposure during catheter-based radiofrequency ablation for pulmonary vein isolation does not increase the risk of intraprocedural complications in patients with paroxysmal or persistent atrial fibrillation. This approach allows for a significant reduction in the total dose area product (DAP) and radiation dose without increasing the duration of the PVI procedure.