EPEugene O. Perepeka

Eugene O. Perepeka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eugene O. Perepeka has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Абляція імпульсним полем при фібриляції передсердь: інтрапроцедурні характеристики та профіль безпечності

    by E. O. Perepeka, B. B. Kravchuk

    Абляція імпульсним полем (АІП) – нетермальна технологія катетерного лікування фібриляції передсердь (ФП), що забезпечує тканинну селективність та потенційно вищий профіль безпечності порівняно з термальними методами. Дані щодо інтрапроцедурних характеристик та безпечності АІП у реальній клінічній практиці продовжують накопичуватися.Мета роботи – проаналізувати інтрапроцедурні характеристики та профіль безпечності абляції імпульсним полем у пацієнтів із фібриляцією передсердь та іншими передсердними тахіаритміями.Матеріали і методи. Ретроспективно проаналізовано дані 285 пацієнтів, яким виконували катетерну абляцію із застосуванням технології абляції імпульсним полем у ДУ «Національний науковий центр серцево-судинної хірургії та судинної патології імені М.М. Амосова НАМН України». Оцінювали клінічні характеристики, тривалість втручання, час перебування в лівому передсерді, кількість аплікацій, обсяг додаткових ліній абляції та інтра- і перипроцедурні ускладнення. Результати. З проаналізованої когорти первинний діагноз ФП мали 277 (97,2 %) пацієнтів: пароксизмальну форму – 170 (59,6 %), персистентну – 87 (30,5 %), тривалоперсистентну – 20 (7,0 %). Тривалість втручання, час у лівому передсерді та кількість аплікацій закономірно зростали від пароксизмальної до тривалоперсистентної форми (усі p<0,001). Частота застосування додаткових ліній суттєво збільшувалася зі зростанням тривалості аритмії: 11,2 %, 59,8 % та 85,0 % відповідно (p<0,001). Значущі ускладнення зафіксовано у 4 (1,4 %) пацієнтів, з яких специфічним для абляції імпульсним полем був 1 (0,35 %) випадок транзиторного спазму правої коронарної артерії. Не зареєстровано жодного випадку гострого пошкодження нирок внаслідок гемолізу, стенозу легеневих вен або ушкодження діафрагмального нерва.Висновки. Абляція імпульсним полем при ФП має сприятливий профіль безпечності з мінімальною часткою специфічних для застосування цього джерела енергії ускладнень. Час втручання зростає зі збільшенням обсягу субстратної абляції при більш тривалих формах аритмії.

  • Open Access

    Комп’ютерно-томографічна ангіографія легеневих вен: нормальна анатомія та неаномальні варіанти в контексті планування катетерної ізоляції легеневих вен

    by M. S. Ishchenko, E. O. Perepeka

    Catheter pulmonary vein isolation (PVI) is currently considered a key rhythm-control strategy in patients with symptomatic, drug-refractory atrial fibrillation, and the number of ablation procedures continues to increase steadily each year. The success and safety of PVI largely depend on individual anatomical characteristics of the pulmonary veins and the left atrium.The aim – to evaluate the prevalence and patterns of pulmonary vein anatomical variants assessed by computed tomography in patients with atrial fibrillation scheduled for catheter pulmonary vein isolation.Methods. This retrospective single-center study included 164 patients with atrial fibrillation who underwent preprocedural CT angiography of the pulmonary veins between 2020 and 2025. The number, drainage pattern, ostial configuration, and anatomical variants of pulmonary veins were analyzed using three-dimensional reconstruction.Results. Typical anatomy with four separate pulmonary veins was identified in 64.6 % of patients. Anatomical variants were detected in 35.4 % of cases. The most frequent variants were left-sided common trunk (15.2 %) and additional right pulmonary veins (13.4 %). Left-sided pseudo-trunk was observed in 3.0 % of patients. CT coronary assessment additionally revealed a substantial prevalence of concomitant coronary artery disease or limited diagnostic image quality.Conclusions. Anatomical variability of the pulmonary veins is common among patients with atrial fibrillation and has important implications for procedural planning of pulmonary vein isolation. Preprocedural CT with 3D reconstruction enables detailed anatomical assessment, supports individualized ablation strategies, and may contribute to improved procedural safety and effectiveness.

  • Open Access

    Predictors of Arrhythmia Recurrence after Catheter Radiofrequency Pulmonary Vein Isolation in Patients with Paroxysmal and Persistent Atrial Fibrillation

    by Eugene O. Perepeka, Borys B. Kravchuk, Maryna M. Sychyk

    Background. Catheter pulmonary vein isolation (PVI) is currently the main rhythm-control strategy in patients with symptomatic atrial fibrillation (AF) refractory to antiarrhythmic drug therapy, according to contemporary clinical guidelines. Given the increasing number of ablation procedures performed annually and the high demand for optimization of healthcare resources, the identification of reliable predictors of AF recurrence remains of particular clinical importance. Aim. To identify independent predictors of AF recurrence within control observation period after first-time catheter PVI. Materials and Methods. In this retrospective analysis, 70 consecutive patients who underwent catheter radiofrequency PVI at the State Institution “Amosov National Institute of Cardiovascular Surgery of the National Academy of Medical Sciences of Ukraine” between May 2022 and December 2024 were included to assess long-term outcomes and predictors of arrhythmia recurrence. Results. Patients who experienced recurrence had higher LVEF (59.48±5.26 % vs 55.36±9.35 %; p=0.027) and lower end-diastolic index (59.38±5.57 vs 67.2±9.69 mL/m²; p=0.019). The non-recurrence group had shorter R–R intervals (761.06±124.58 vs 874.14±141.17 ms; p=0.045) and higher heart rate (80.5±13.92 vs 69.93±12.08 bpm; p=0.045) at the end of the procedure. Procedure duration was longer in recurrence group (161.18±32.81 vs 113.33±23.2 min; p<0.001). Fibrosis on voltage mapping tended to be higher in recurrence group (1.64±1.21 vs 0.79±0.73; p=0.064). After a 20-minute waiting period, the absence of pulmonary vein (PV) reconnection was more frequent in the non-recurrence group (15/25 vs 7/18; p=0.003), whereas reconnection of two veins occurred exclusively in the recurrence group (7 patients). In multivariable regression analysis, procedure duration was the only independent predictor (B=0.08; OR=1.08; 95 % CI 1.01-1.16; p=0.033). Conclusions. AF recurrence after PVI was primarily associated with procedural instability, specifically intraprocedural pulmonary vein reconnection. Longer procedure duration – likely reflecting substrate complexity and/or technical challenges – was the only independent predictor.

  • Open Access

    Варіабельність серцевого ритму в пацієнтів після катетерної радіочастотної ізоляції легеневих вен

    by E. O. Perepeka, V. V. Lazoryshynets

    The aim – to analyze the dynamics of heart rate variability in patients who underwent radiofrequency isolation of pulmonary veins using the «high power – short duration» technique, and to determine its relationship with the probability of arrhythmia recurrence in the postoperative period.Materials and methods. To conduct a study of heart rate variability, a total of 114 patients with paroxysmal and persistent forms of atrial fibrillation (AF) were analyzed, who underwent catheter radiofrequency pulmonary vein isolation at the State Institution «National Institute of Cardiovascular Surgery named after M.M. Amosov of the National Academy of Medical Sciences of Ukraine» for the period from May 2022 to December 2024. 49 patients were selected for the study in whom long-term results regarding arrhythmia recurrence were monitored.Results. The follow-up period of patients after pulmonary vein isolation (PVI) was on average 19.87±7.56 months (range 8 to 34 months). The frequency of arrhythmia recurrence during this period was 38 %. 26.4 % of patients were diagnosed with persistent atrial fibrillation (AF). At all time points, patients without recurrence had a higher mean heart rate, which may indicate a more effective denervation. The largest difference was observed after 2 months: in patients without recurrence 73.44±9.93 beats/min, with recurrence: 62.50±10.45 beats/min (p=0.01). After 1, 6, and 12 months, there was a trend towards a decrease in heart rate in the group of patients with arrhythmia recurrence, although it did not reach statistical significance (p>0.05). Patients with recurrence showed significantly higher RMSSD values, especially at 2 and 12 months. 2 months: 51.25±68.60 vs 19.00±11.59 (p=0.365); 12 months: 32.6±22.9 vs 15.43±6.00 (p=0.026). At 1 month, SDNN was significantly higher in patients with recurrence: 77.50±38.78 vs 53.51±20.86 (p=0.047). SDNNi is also higher in patients with relapse: 1 month – 44.13±25.31 vs 28.00±11.26 (p=0.021); 2 months: 55.0±38.4 vs 26.67±4.23 (p=0.002). This may be due to incomplete or transient modulation of ganglionic structures, which is manifested by a high SDNN. At later times (6–12 months), the differences smoothed out and statistical significance was not found. pNN50 is another marker of parasympathetic activity. Significant differences in pNN50 were found at 12 months: 8.95±9.92 (with relapse) vs 1.78±1.78 (without) (p=0.026). Paroxysmal AF was more common in the group without recurrence (86 % vs. 73 %), which was statistically significant (p=0.022). Also, the end-diastolic index (EDI) was significantly higher in the group without recurrence (66.02±9.78 vs. 59.56±4.05; p=0.023). The left atrial diameter tended to be larger in the group of patients with recurrence ((43.47±5.15) vs. (41.77±4.64) mm; p=0.091). Body mass index (BMI) tended to be higher in the group without recurrence (30.35±5.78 vs. 27.36±3.84; p=0.054), but the difference did not reach statistical significance.Conclusions. Patients with signs of more pronounced intraoperative modification of parasympathetic ganglia functions during catheter radiofrequency isolation of the lungs with fewer arrhythmia recurrences during time control are observed in 19.87±7.56 months. Lower RMSSD values ​​in use without recurrence, especially in the early stages after ablation, as well as lower pNN50 values ​​after 12 months confirm a decrease in parasympathetic activity, compared with patients in whom arrhythmia recurrence occurred. Changes in HRV may be useful for assessing the effectiveness of concomitant cardioneuroablation during pulmonary vein isolation.


  • Open Access

    Autonomous Effects of Catheter Radiofrequency Pulmonary Vein Isolation Ablation Using a High-Power and Short-Duration Technique

    by Eugene O. Perepeka

    Introduction. Catheter-based pulmonary vein ablation (PVA) is the gold standard for the treatment of symptomatic, drug-refractory atrial fibrillation (AF). The effect of catheter ablation on the autonomic nervous system, particularly the parasympathetic system–referred to as the “cardioneuroeffect” – represents an important side effect that may contribute to more stable outcomes of the procedure. Aim. To investigate the intraoperative autonomic effects of high-power, short-duration pulmonary vein isolation. Materials and Methods. For this retrospective study, 49 patients with paroxysmal and persistent forms of AF were selected, in whom long-term outcomes regarding arrhythmia recurrence could be tracked. All patients underwent catheter-based radiofrequency ablation at the State Institution “National Institute of Cardiovascular Surgery named after M. M. Amosov of the National Academy of Medical Sciences of Ukraine” between May 2022 and December 2024. Results. Over a mean observation period of 19.87 ± 7.56 months (range 8-34), recurrences occurred in 19 out of 49 patients (38 %). In patients without recurrence, there was a pronounced decrease in the R-R interval during the intervention (889.33 ± 157.48 vs. 762.92 ± 133.81 ms, p=0.003) and a significant increase in heart rate (69 ± 11.96 vs. 80.67 ± 15.53 bpm, p=0.003). In patients with recurrence, changes in the R-R interval and heart rate were not statistically significant (p=0.09 and p=0.117), indicating smaller autonomic modulation. At the end of the procedure, the R-R interval and heart rate were significantly higher and lower, respectively, in the recurrence group (874.25 ± 137.06 ms vs. 762.92 ± 133.81 ms, p=0.029; 69.75 ± 11.85 vs. 80.67 ± 15.53 bpm, p=0.022). Patients with recurrence had a higher mean degree of left atrial fibrosis according to voltage mapping (1.64 ± 1.21 vs. 0.84 ± 0.72), but this difference did not reach statistical significance (p=0.11). Absence of reconnection during the intervention was observed in 62.5 % of patients without recurrence, compared to only 30.8 % in the recurrence group. Reconnection in two veins occurred exclusively in the recurrence group (54 % of cases), which was not observed in any patient without recurrence. This difference was statistically significant (p=0.003). Conclusions. During catheter radiofrequency isolation of the pulmonary veins in patients with paroxysmal and persistent AF, a more pronounced effect of cardioneuromodulation was associated with a reduction in arrhythmia recurrences during the postoperative period.

  • Open Access

    Assessment of the Degree of Left Atrial Fibrosis in Patients with Different Forms of Atrial Fibrillation

    by Eugene O. Perepeka, Elina V. Bodnarevska, Mykhailo S. Ishchenko, Borys B. Kravchuk

    Atrial fibrillation (AF) is the most common type of cardiac arrhythmia, which has a significant impact on the health of patients worldwide. Left atrial fibrosis (LAF) is considered an irreversible form of remodeling that occurs in response to inflammation, stretching, or overload of the left atrium. The prevalence and degree of LAF may be associated with the prognosis and treatment outcomes after catheter ablation. Aim. To determine whether the degree of left atrial fibrosis is associated with the progression of atrial fibrillation. Materials and methods. During the period from January 2023 to December 2024, the State Research Institute of Cardiology named after M.M. Amosov National Academy of Medical Sciences of Ukraine performed 58 MRI studies with late contrast enhancement with gadolinium to study the degree of fibrosis of different chambers of the heart. Thirty-six of these patients were diagnosed with AF. In 12 patients, catheter ablation for atrial fibrillation was subsequently performed (radiofrequency, cryoballoon ablation, or pulsed field ablation). In 10, an attempt at electrical cardioversion without catheter intervention was performed. Results. Among the 34 patients included in the study, 13 (38 %) had paroxysmal AF, 14 (41 %) had persistent AF, and 7 (21 %) had permanent AF. Among the patients with paroxysmal AF, 9 (69 %) had stage I of left atrial fibrosis (LAF), 4 (31 %) had LAF stage II. No patients with LAF stage III-IV were observed in the paroxysmal AF group. In the persistent AF group (n = 14, 41 %), LAF stage I was observed in 4 (29 %) patients, LAF stage II in 8 (57 %), and LAF stage III and IV in 1 (7 %) patient in each group. In the patients with permanent AF (n = 7, 21 %), no patients with LAF stage I were observed. LAF stage II was observed in 4 (57 %) patients, LAF stage III in 2 (28 %), and LAF stage IV in 1 (14 %). The analysis showed a statistically significant decrease in left ventricular ejection fraction in patients with progressive AF. In the paroxysmal group, the mean LVEF was 55.75 ± 11.05 %, while in patients with persistent AF it decreased to 47.46 ± 13.88 %, and in chronic AF it decreased to 36.29 ± 12.08 % (p = 0.018). Conclusions. According to our results, the degree of fibrosis of the left atrium correlates with the stage of progression of atrial fibrillation.

  • Open Access

    Evaluation of the Results of Left Bundle Branch Pacing after Atrioventricular Junction Ablation in Patients with Chronic Atrial Fibrillation

    by Eugene O. Perepeka, Borys B. Kravchuk

    Atrioventricular junction ablation (AVJA) together with the implantation of cardiac pacemaker has become a recognized and effective treatment strategy for patients with symptomatic tachysystolic atrial fibrillation that does not respond to heart rate control drug therapy. Left bundle branch pacing (LBBP) is a physiological alternative to right ventricular and biventricular pacing. The aim. To analyze the clinical results of the average duration with the use of LBBP and AVJA. Materials and methods. Over the period from January 2023 to July 2024, LBBP with subsequent AVJA was applied at the National Amosov Institute of Cardiovascular Surgery in 18 patients as a method of treatment of chronic tachysystolic atrial fibrillation to achieve heart rate control. Results. Mid-term results (at least 1 month) could be monitored in 15 out of 18 patients (84%); in the other three (16%) patients the time between pacemaker implantation and AVJA was too short. The mean period from pacemaker implantation to control examination was 5.07 ± 2.79 months (minimum period 1 month, maximum 12 months). During the period from implantation and ablation to the control observation in the study group, it was possible to observe an increase in left ventricular ejection fraction from 39.12 ± 10.56% to 46.38 ± 7.09%, p = 0.035; decrease in the values of end-diastolic volume from 184.22 ± 76.76 to 167.85 ± 36.93 ml, p = 0.074; decrease in the right ventricular pressure from 43.07 ± 8.29 to 34.38 ± 4.78 mm Hg, p = 0.013. It was also possible to observe a decrease in the left bundle branch capture thresholds from 1.27 ± 0.58 to 0.7 ± 0.39 V at 0.4 ms, p = 0.016; and a decrease in the average LBBP endocardial lead resistance from 638 ± 172.83 to 529.4 ± 120.15 Ohm, p = 0.012. Conclusions. Implantation of the LBBP pacemaker and AVJA was not associated with the occurrence of complications both in the intraoperative and postoperative periods, as well as in the remote period of the average duration in the studied group. The use of this approach in patients with chronic atrial fibrillation made it possible in a series of consecutive patients to improve the systolic function of the left ventricle, to reduce the values of the end-diastolic volume of the left ventricle and the right ventricular pressure at optimal pacing parameters.

  • Open Access

    Minimizing Exposure to Ionizing Radiation in Catheter-Based Treatment of Atrial Fibrillation: Safety and Efficacy

    by Eugene O. Perepeka, Borys B. Kravchuk, Maryna M. Sychyk, Svitlana L. Mykolaichuk

    Pulmonary vein isolation using radiofrequency ablation is the most common method of catheter treatment for atrial fibrillation. Performing this procedure involves the use of X-ray radiation, which at certain stages of the procedure is an indispensable method for navigation and visualization of intracardiac structures. Approaches to minimize X-ray exposure during catheter interventions are attracting increased attention of the electrophysiology community due to the potential risks of adverse effects of ionizing radiation on patients and medical personnel. The aim. To evaluate the effectiveness and safety of performing the pulmonary vein isolation procedure with the intention to minimize X-ray exposure of patients and medical personnel. Materials and methods. Forty-three patients with various forms of atrial fibrillation were selected for the study: 28(65%) with paroxysmal and 15 (35%) with persistent forms. All the patients underwent pulmonary vein isolation usingcatheter radiofrequency ablation with the intention to minimize X-ray exposure at the National Amosov Institute of Cardiovascular Surgery in the period from June 2023 to April 2024. Results. In all 43 patients it was possible to electrically isolate all the veins. Catheter ablation of the cavotricuspidisthmus was performed in 5 (31.2%) patients from group A (“Zero-fluoro”), 7 (33.3%) from group B (“Near Zero-fluoro”) and 3 (50%) from group C (“Non Zero-fluoro”) (p = 0.696). Intraoperative reconnection of the pulmonary veins with the left atrium was observed in 6 (37.5%) patients of group A, 11 (52.3%) of group B, and 4 (66%) of group C (p = 0.429). X-ray time for transseptal puncture did not differ between groups A and B (3.56 ± 2.37 vs. 3.69 ± 2.3 min., p = 0.532), however, X-ray time for pulmonary vein isolation in group A was significantly less than that in group B (0.27 ± 0.13 vs. 1.96 ± 1.21 min., p < 0.001). The total time in the left atrium was not statistically different between these two groups (81.33 ± 22.32 vs. 98.6 ± 29.83 min., p = 0.106). In group C (“Non Zero-fluoro”), the aforementioned parameters were not recorded. Total dose area product (DAP) and total radiation dose, as well as total X-ray time and total procedure time, were significantly lower when using the ionizing exposure minimization approach. DAP and total radiation dose in group A were the lowest (7.29 ± 5.16 Gy/cm2 and 76.62 ± 70.82 mGy, respectively) and significantly differed from those in group C (107.67 ± 97.59 Gy/cm2 and 882.32 ± 868.62 mGy, p < 0.001 and p = 0.001, respectively). No intraoperative complications were observed in the studied sample. Conclusions. Minimizing X-ray exposure using modern navigation systems during pulmonary vein isolation using catheter radiofrequency ablation is not associated with increased intraprocedural complications in patients with paroxysmal and persistent atrial fibrillation. This approach allows you to significantly lower total DAP and the radiation dosewithout increasing the time of performing the pulmonary vein isolation procedure.

  • Open Access

    Cardiomyopathy prediction in patients with permanent ventricular pacing using machine learning methods

    by Eugene Perepeka, Vasyl Lazoryshynets, Vitalii Babenko, Illia Davydovych, Ievgen Nastenko

    Pacing-induced cardiomyopathy is a notable issue in patients needing permanent ventricular pacing. Identifying risk groups early and swiftly preventing the ailment can reduce patient harm. However, current prognostic methods require clarity. We employed machine learning to develop predictive models using medical data. Three algorithms — decision tree, group method of data handling, and logistic regression — formed models that forecast pacing-induced cardiomyopathy. These models displayed high accuracy in predicting development, signifying soundness. Factors like age, paced QRS width, pacing mode, and ventricular index during implantation significantly influenced predictions. Machine learning can enhance pacing-induced cardiomyopathy prediction in ventricular pacing patients, aiding medical practice and preventive strategies. Кардіоміопатія, спричинена кардіостимуляцією, є важливою проблемою для пацієнтів, які потребують постійної шлуночкової кардіостимуляції. Раннє виявлення груп ризику та швидка профілактика недуги можуть зменшити шкоду для пацієнтів. Однак сучасні методи прогнозування потребують доопрацювання. Застосовано машинне навчання для розроблення прогностичних моделей на основі медичних даних. Три алгоритми — дерево рішень, група оброблення даних та логістична регресія — сформували моделі, які прогнозують кардіоміопатію, спричинену кардіостимуляцією. Ці моделі показали високу точність у прогнозуванні розвитку, що свідчить про їх надійність. Ключові фактори, такі як вік, ширина QRS, режим кардіостимуляції та шлуночковий індекс під час імплантації, суттєво впливали на прогнози. Машинне навчання може покращити прогнозування кардіоміопатії, спричиненої кардіостимуляцією, у пацієнтів, які перебувають на шлуночковій електрокардіостимуляції, допомагаючи медичній практиці та профілактичним стратегіям.

  • Open Access

    Safety of One-Stage Atrioventricular Junction Ablation after Pacemaker Implantation for Left Bundle Branch Pacing

    by Eugene O. Perepeka, Roman A. Sikhnevych

    Atrial fibrillation (AF) is one of the most common arrhythmias. Atrioventricular (AV) junction ablation combined with pacemaker implantation has become an accepted, effective strategy for the treatment of symptomatic tachysystolic AF resistant to drug therapy, especially in the elderly. Left bundle branch (LBB) pacing is a physiological alternative to right ventricular pacing. The aim. This study evaluated the effectiveness and safety of a one-stage application of the implantation system for LBB pacing and ablation of the AV junction. Materials and methods. For the period from January 2023 to February 2024, LBB pacing was applied in 8 patients at the National Amosov Institute of Cardiovascular Surgery in the context of treatment of chronic tachysystolic form of AF with subsequent ablation of the AV junction, as a strategy to control heart rate. Results. In all the patients, LBB pacing criteria were achieved: Qr or qR in V1 QRS complex morphology type during pacing (100%); St-V6RWPT interval < 80 ms (mean 75.8 ± 13.9 ms); the difference between the intervals St-V1RWPT – St-V6RWPT > 44 ms (mean 55.57 ± 10.09 ms). In 3 out of 8 patients (37%) it was possible to register LBB potential. Mean paced QRS width in the studied group was 130 ± 18.02 ms. The mean intraoperative LBB pacing threshold was 1.71 ± 0.39 V for 0.4 ms, the anodal pacing threshold was 3.25 ± 0.5 V for 0.4 ms (we could demonstrate it in 6 out of 8 patients [75%]). Intraoperative lead perforation through the interventricular septum could be observed in 2 out of 8 cases (25%), but after that it was possible to successfully reimplant the lead in the area of the LBB. In all the patients of the studied group, it was possible to successfully perform radiofrequency ablation of the AV junction with the aim of heart rate control in chronic tachysystolic AF. There was no endocardial lead dislodgement in the postoperative period in any of the patients. Conclusions. In the studied group, no complications and hemodynamic disturbances were observed in the acute postoperative period and during follow-up one week after the pacemaker implantation for LBB pacing and AV junction ablation. Intraoperative transseptal perforation of the endocardial lead did not complicate reimplantation of the lead in the LBB area. A single-stage pacemaker implantation for LBB pacing and AV junction ablation can significantly shorten the patient’s stay in a medical institution. The subject requires further research on a larger number of patients with long-term follow-up.