Jiayu Bai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiayu Bai has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Xi Wang
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
5 shared publications - Baorui Chen
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
4 shared publications - Peng Shi
State Grid Sichuan Electric Power Research Institute, Chengdu 610072, China
4 shared publications - Zongsheng Zheng
School of Electrical Engineering, Sichuan University, Chengdu 610065, China
3 shared publications - Chengwei Fan
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
2 shared publications - Deqiang Gan
Zhejiang University
2 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4964
Physics-Informed Multi-Agent Transient Voltage Support with Simplified UHVDC Receiving-End Characteristics
This paper presents the PIML-agent, a physics-informed multi-agent strategy for transient voltage support in ultra-high-voltage direct-current (UHVDC) receiving-end systems. A stress-risk signal derived from a reduced-order receiving-end model is fused with local, neighborhood, and receiving-area voltage channels in a distributed control law whose coordination gains are learned by derivative-free policy search over randomized physics-model rollouts. On the IEEE 39-bus benchmark, with all controllers sharing one receiving-end model and identical actuator limits, the PIML-agent reduces the receiving-area voltage deviation integral by 87.67–97.48% relative to no control and 76.95–94.84% relative to local rule-based support across six fault, load, delayed-support, corridor, and UHVDC-recovery scenarios, and its six-scenario mean by 60.05% relative to a cooperative multi-agent controller. It shortens the average sub-0.90 pu violation duration from 3.62 s (local rule) to 0.56 s and restores the voltage above 0.95 pu within 0.80–2.14 s after fault clearing. It outperforms every baseline in all 100 unseen randomized disturbances, and gains transferred without retraining to the 140-bus NPCC system achieve a 94.80% reduction relative to no control. The advantage persists under gain perturbations, communication delay and loss, agent outage, measurement noise, stronger disturbances, reduced capacity, and model mismatch.
- 27 October 2026
- Published by MDPI AG in Electronics
- Vol. 15 (21) , 4964
Open AccessPhysics-Informed Multi-Agent Transient Voltage Support with Simplified UHVDC Receiving-End Characteristics
This paper presents the PIML-agent, a physics-informed multi-agent strategy for transient voltage support in ultra-high-voltage direct-current (UHVDC) receiving-end systems. A stress-risk signal derived from a reduced-order receiving-end model is fused with local, neighborhood, and receiving-area voltage channels in a distributed control law whose coordination gains are learned by derivative-free policy search over randomized physics-model rollouts. On the IEEE 39-bus benchmark, with all controllers sharing one receiving-end model and identical actuator limits, the PIML-agent reduces the receiving-area voltage deviation integral by 87.67–97.48% relative to no control and 76.95–94.84% relative to local rule-based support across six fault, load, delayed-support, corridor, and UHVDC-recovery scenarios, and its six-scenario mean by 60.05% relative to a cooperative multi-agent controller. It shortens the average sub-0.90 pu violation duration from 3.62 s (local rule) to 0.56 s and restores the voltage above 0.95 pu within 0.80–2.14 s after fault clearing. It outperforms every baseline in all 100 unseen randomized disturbances, and gains transferred without retraining to the 140-bus NPCC system achieve a 94.80% reduction relative to no control. The advantage persists under gain perturbations, communication delay and loss, agent outage, measurement noise, stronger disturbances, reduced capacity, and model mismatch.
- Open Access
- 15 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 840
Hierarchical Risk-Warning Method Integrating Transient Voltage Prediction Based on Koopman-Theory-Based Transient Voltage Trajectory Prediction and Stability Margin Quantification
This paper addresses the transient voltage stability problem in power systems with high penetration of renewable energy by proposing a hierarchical risk-warning method that integrates Koopman-theory-based transient voltage trajectory prediction and stability margin quantification. First, an online Koopman-theory-based transient voltage trajectory prediction model is constructed through the adaptive optimization of basis functions, a dynamic operator update mechanism, and multistage error correction, significantly enhancing prediction accuracy and generalization capability. Second, a piecewise-weighted quantitative index for transient voltage stability margins is proposed, achieving refined stability assessments ranging from individual nodes to the entire system. Finally, a risk-mapping function based on utility theory is established to convert continuous margin indices to discrete risk levels, forming a complete hierarchical warning system for the transient voltage risk. Simulation results demonstrate that the proposed method achieves precise voltage trajectory prediction and stable-state judgment across various scenarios, effectively identifies critical system weaknesses, and provides reliable technical support for the safety prevention and control of the power system’s transient voltage.
- 15 February 2026
- Published by MDPI AG in Electronics
- Vol. 15 (4) , 840
Open AccessHierarchical Risk-Warning Method Integrating Transient Voltage Prediction Based on Koopman-Theory-Based Transient Voltage Trajectory Prediction and Stability Margin Quantification
This paper addresses the transient voltage stability problem in power systems with high penetration of renewable energy by proposing a hierarchical risk-warning method that integrates Koopman-theory-based transient voltage trajectory prediction and stability margin quantification. First, an online Koopman-theory-based transient voltage trajectory prediction model is constructed through the adaptive optimization of basis functions, a dynamic operator update mechanism, and multistage error correction, significantly enhancing prediction accuracy and generalization capability. Second, a piecewise-weighted quantitative index for transient voltage stability margins is proposed, achieving refined stability assessments ranging from individual nodes to the entire system. Finally, a risk-mapping function based on utility theory is established to convert continuous margin indices to discrete risk levels, forming a complete hierarchical warning system for the transient voltage risk. Simulation results demonstrate that the proposed method achieves precise voltage trajectory prediction and stable-state judgment across various scenarios, effectively identifies critical system weaknesses, and provides reliable technical support for the safety prevention and control of the power system’s transient voltage.
- Open Access
- 24 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 191
Slow-Coherency-Based Controlled Splitting Strategy Considering Wind Power Uncertainty and Multi-Infeed HVDC Stability
In the context of a high proportion of renewable energy integration, active splitting section search—one of the “three defense lines” of a power system—is crucial for the security, stability, and long-term sustainability of islanded grids. Addressing the random fluctuations of high-penetration wind power and the weakened voltage support capability caused by multi-infeed HVDC, this paper proposes a slow-coherency-based active splitting section optimization model that explicitly accounts for wind power uncertainty and multi-infeed DC stability constraints. First, a GMM-K-means method is applied to historical wind data to model, sample, and cluster scenarios, efficiently generating and reducing a representative set of typical wind outputs; this accurately captures wind uncertainty while lowering computational burden. Subsequently, an improved particle swarm optimizer enhanced by genetic operators is used to optimize a multi-dimensional coherency fitness function that incorporates a refined equivalent power index, frequency constraints, and connectivity requirements. Simulations on a modified New England 39-bus system demonstrate that the proposed model markedly enlarges the post-split voltage stability margin and effectively reduces power-flow shocks and power imbalance compared with existing methods. This research contributes to enhancing the sustainability and operational resilience of power systems under energy transition.
- 24 December 2025
- Published by MDPI AG in Sustainability
- Vol. 18 (1) , 191
Open AccessSlow-Coherency-Based Controlled Splitting Strategy Considering Wind Power Uncertainty and Multi-Infeed HVDC Stability
In the context of a high proportion of renewable energy integration, active splitting section search—one of the “three defense lines” of a power system—is crucial for the security, stability, and long-term sustainability of islanded grids. Addressing the random fluctuations of high-penetration wind power and the weakened voltage support capability caused by multi-infeed HVDC, this paper proposes a slow-coherency-based active splitting section optimization model that explicitly accounts for wind power uncertainty and multi-infeed DC stability constraints. First, a GMM-K-means method is applied to historical wind data to model, sample, and cluster scenarios, efficiently generating and reducing a representative set of typical wind outputs; this accurately captures wind uncertainty while lowering computational burden. Subsequently, an improved particle swarm optimizer enhanced by genetic operators is used to optimize a multi-dimensional coherency fitness function that incorporates a refined equivalent power index, frequency constraints, and connectivity requirements. Simulations on a modified New England 39-bus system demonstrate that the proposed model markedly enlarges the post-split voltage stability margin and effectively reduces power-flow shocks and power imbalance compared with existing methods. This research contributes to enhancing the sustainability and operational resilience of power systems under energy transition.
- Open Access
- 12 December 2025
- Published by MDPI AG in Electronics
- Vol. 14 (24) , 4887
Hybrid N-BEATS-Based Method for Equipment Assessment and System Risk Prediction in Urban Power Grids
To improve power system risk prediction under complex and extreme operating conditions, a hybrid N-BEATS-based framework is proposed for equipment assessment and loss of load expectation (LOLE) forecasting. The method integrates thermal circuit modeling, online thermal parameter identification via physics-informed neural networks (PINNs), Arrhenius–Weibull temperature–failure mapping, Monte Carlo system risk evaluation, and a hybrid spatiotemporal predictor combining N-BEATS and graph neural networks. Case studies on distribution transformers demonstrate improved thermal parameter identification and reduced LOLE forecasting error compared with benchmark methods. The remainder of the paper is organized as follows: Firstly, it presents thermal modeling and PINN identification; Secondly, it introduces the aging-failure and reliability evaluation; Thirdly, it describes the hybrid forecasting framework; Fourthly, it reports case studies; and finally, it concludes.
- 12 December 2025
- Published by MDPI AG in Electronics
- Vol. 14 (24) , 4887
Open AccessHybrid N-BEATS-Based Method for Equipment Assessment and System Risk Prediction in Urban Power Grids
To improve power system risk prediction under complex and extreme operating conditions, a hybrid N-BEATS-based framework is proposed for equipment assessment and loss of load expectation (LOLE) forecasting. The method integrates thermal circuit modeling, online thermal parameter identification via physics-informed neural networks (PINNs), Arrhenius–Weibull temperature–failure mapping, Monte Carlo system risk evaluation, and a hybrid spatiotemporal predictor combining N-BEATS and graph neural networks. Case studies on distribution transformers demonstrate improved thermal parameter identification and reduced LOLE forecasting error compared with benchmark methods. The remainder of the paper is organized as follows: Firstly, it presents thermal modeling and PINN identification; Secondly, it introduces the aging-failure and reliability evaluation; Thirdly, it describes the hybrid forecasting framework; Fourthly, it reports case studies; and finally, it concludes.
- Open Access
- 5 August 2025
- Published by MDPI AG in Electronics
- Vol. 14 (15) , 3119
Parameter Identification Method of Grid-Forming Static Var Generator Based on Trajectory Sensitivity and Proximal Policy Optimization Algorithm
As the penetration rate of new energy continues to increase, the active voltage support capability of the power system is decreasing. The grid-forming static var generator (GFM-SVG) features the advantages of fast dynamic response, strong reactive power support, and high overload capacity, which play an important role in maintaining voltage stability. However, the parameters of the GFM-SVG are often unknown due to trade secret reasons. Meanwhile, the parameters may be changed during the long-term operation of the system, which brings challenges to the system stability analysis and control. Aiming at this problem, a parameter identification method based on trajectory sensitivity analysis and the proximal policy optimization (PPO) algorithm is proposed in this paper. Firstly, through trajectory sensitivity analysis, the key influential parameters on the output characteristics of the GFM-SVG can be selected, which can reduce the dimensionality of the identification parameters and improve the identification efficiency. Then, a parameter identification framework based on the PPO algorithm is constructed for GFM-SVGs, which utilizes its adaptive learning capability to achieve accurate identification of the key parameters of the system. Finally, the effectiveness of the proposed parameter identification method is verified through simulation examples. The simulation results show that the identification error of the parameters in the GFM-SVG is small. The proposed method can characterize the output response of the GFM-SVG under different operating conditions.
- 5 August 2025
- Published by MDPI AG in Electronics
- Vol. 14 (15) , 3119
Open AccessParameter Identification Method of Grid-Forming Static Var Generator Based on Trajectory Sensitivity and Proximal Policy Optimization Algorithm
As the penetration rate of new energy continues to increase, the active voltage support capability of the power system is decreasing. The grid-forming static var generator (GFM-SVG) features the advantages of fast dynamic response, strong reactive power support, and high overload capacity, which play an important role in maintaining voltage stability. However, the parameters of the GFM-SVG are often unknown due to trade secret reasons. Meanwhile, the parameters may be changed during the long-term operation of the system, which brings challenges to the system stability analysis and control. Aiming at this problem, a parameter identification method based on trajectory sensitivity analysis and the proximal policy optimization (PPO) algorithm is proposed in this paper. Firstly, through trajectory sensitivity analysis, the key influential parameters on the output characteristics of the GFM-SVG can be selected, which can reduce the dimensionality of the identification parameters and improve the identification efficiency. Then, a parameter identification framework based on the PPO algorithm is constructed for GFM-SVGs, which utilizes its adaptive learning capability to achieve accurate identification of the key parameters of the system. Finally, the effectiveness of the proposed parameter identification method is verified through simulation examples. The simulation results show that the identification error of the parameters in the GFM-SVG is small. The proposed method can characterize the output response of the GFM-SVG under different operating conditions.
- Open Access
- 26 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (7) , 3638
A New Method for Constructing the Static-Voltage-Stability Boundary with a Conversion Strategy
The static-voltage-stability region (SVSR) is an effective tool for monitoring the safe operation of grid voltage. Rapidly obtaining the static-voltage-stability-region boundary (SVSRB) of a power system is crucial for the application of SVSR technology. First, this paper reveals the mechanisms underlying the failure scenarios that may occur with conventional boundary tracking methods. Then, an improved method incorporating curve extrapolation and correction conversion strategies is proposed, which enhances the efficiency of constructing the SVSRB. Furthermore, the analytical expression of the SVSRB is derived from the intermediate information obtained during the predictor stage. Finally, simulation examples based on a simple power system, the IEEE 3-machine, 9-bus power system and IEEE 300-bus power system were developed to verify the accuracy and efficiency of the proposed method.
- 26 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (7) , 3638
Open AccessA New Method for Constructing the Static-Voltage-Stability Boundary with a Conversion Strategy
The static-voltage-stability region (SVSR) is an effective tool for monitoring the safe operation of grid voltage. Rapidly obtaining the static-voltage-stability-region boundary (SVSRB) of a power system is crucial for the application of SVSR technology. First, this paper reveals the mechanisms underlying the failure scenarios that may occur with conventional boundary tracking methods. Then, an improved method incorporating curve extrapolation and correction conversion strategies is proposed, which enhances the efficiency of constructing the SVSRB. Furthermore, the analytical expression of the SVSRB is derived from the intermediate information obtained during the predictor stage. Finally, simulation examples based on a simple power system, the IEEE 3-machine, 9-bus power system and IEEE 300-bus power system were developed to verify the accuracy and efficiency of the proposed method.
- Open Access
Inverse Characteristic Locus Method for Power System Low-Frequency Oscillation Control and Optimal Design
Recent results indicate that the characteristic locus method provides a convenient approach for analyzing power system low-frequency stability. In this study, an enhanced version of the method, referred to as the inverse characteristic locus method, is introduced. By inverting the similarity matrix of the loop transfer function matrix of the system, a more reliable and accurate stability metric is obtained. The proposed method is applied to assess the impact of changes in wind turbine generator (WTG) dynamics and system operating conditions on stability. Simulation results demonstrate that variations in system operating conditions exert a greater influence on stability compared to changes in WTG dynamics.
Open AccessInverse Characteristic Locus Method for Power System Low-Frequency Oscillation Control and Optimal Design
Recent results indicate that the characteristic locus method provides a convenient approach for analyzing power system low-frequency stability. In this study, an enhanced version of the method, referred to as the inverse characteristic locus method, is introduced. By inverting the similarity matrix of the loop transfer function matrix of the system, a more reliable and accurate stability metric is obtained. The proposed method is applied to assess the impact of changes in wind turbine generator (WTG) dynamics and system operating conditions on stability. Simulation results demonstrate that variations in system operating conditions exert a greater influence on stability compared to changes in WTG dynamics.
- Open Access
- 23 July 2021
- Published by EDP Sciences
- Vol. 293, 02062
Online Dispatch of Shared Energy Storage with Remote Renewable Generations
The sustained penetration of wind and solar generation is conducive to alleviating the energy crisis and environmental pollution. However, the finite capacity of transmission corridor limits the delivery of remote renewables and leads to curtailment. Energy storage plays an important role in renewables accommodation and improving equipment utilization, and shared energy storage can magnify the benefits through a temporal and spatial complementary. This paper proposes an online dispatch approach of energy storage shared by multiple renewable plants. The uncertainty and non-anticipativity issue are addressed via a two-stage decision-making process. The day-ahead scheduling determines the allowable energy and power levels of shared energy storage; the real-time online dispatch decides the wait-and-see strategies of charging and discharging power based on a single-period optimization model constrained by the pre-scheduled bounds. The case study verifies the effectiveness of the proposed method.
- 23 July 2021
- Published by EDP Sciences
- Vol. 293, 02062
Open AccessOnline Dispatch of Shared Energy Storage with Remote Renewable Generations
The sustained penetration of wind and solar generation is conducive to alleviating the energy crisis and environmental pollution. However, the finite capacity of transmission corridor limits the delivery of remote renewables and leads to curtailment. Energy storage plays an important role in renewables accommodation and improving equipment utilization, and shared energy storage can magnify the benefits through a temporal and spatial complementary. This paper proposes an online dispatch approach of energy storage shared by multiple renewable plants. The uncertainty and non-anticipativity issue are addressed via a two-stage decision-making process. The day-ahead scheduling determines the allowable energy and power levels of shared energy storage; the real-time online dispatch decides the wait-and-see strategies of charging and discharging power based on a single-period optimization model constrained by the pre-scheduled bounds. The case study verifies the effectiveness of the proposed method.
- Open Access
- 1 July 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 529 (1) , 012006
Measurement-driven AA-CAES Model for Distribution Network Dispatch in Coordination with Renewable Generation
Advanced adiabatic compressed air energy storage (AA-CAES) could play an important role in power distribution system for mitigating the intermittency of distributed renewable generations and reducing the peak-valley difference of load demand, which requires to operate AA-CAES under off-design conditions. A power system dispatch oriented AA-CAES model was proposed based on the technically thermodynamic performance curves of compressor and expansion calibrated from experiments, highlighting the impact of AA-CAES part-lard features on charging/discharging efficiency and capacity. The proposed model is integrated with economic dispatch problem of power distribution systems, giving rise to a nonlinear program due to the state-dependent charging and discharging performances. The dispatch model is further linearized via piecewise linear approximation and special-ordered set of type 2, and its equivalent mixed integer linear formulation is presented. A modified IEEE 33-bus system is adopted to verify the effectiveness of proposed model for renewables accommodation.
- 1 July 2020
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 529 (1) , 012006
Open AccessMeasurement-driven AA-CAES Model for Distribution Network Dispatch in Coordination with Renewable Generation
Advanced adiabatic compressed air energy storage (AA-CAES) could play an important role in power distribution system for mitigating the intermittency of distributed renewable generations and reducing the peak-valley difference of load demand, which requires to operate AA-CAES under off-design conditions. A power system dispatch oriented AA-CAES model was proposed based on the technically thermodynamic performance curves of compressor and expansion calibrated from experiments, highlighting the impact of AA-CAES part-lard features on charging/discharging efficiency and capacity. The proposed model is integrated with economic dispatch problem of power distribution systems, giving rise to a nonlinear program due to the state-dependent charging and discharging performances. The dispatch model is further linearized via piecewise linear approximation and special-ordered set of type 2, and its equivalent mixed integer linear formulation is presented. A modified IEEE 33-bus system is adopted to verify the effectiveness of proposed model for renewables accommodation.