Caroline Mattos Barbosa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Caroline Mattos Barbosa has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Ademir Xavier Da Silva
Nuclear Engineering Graduate Program, Federal University of Rio de Janeiro (COPPE/UFRJ), Rio de Janeiro, Brazil
2 shared publications - Cesar Raitz
Nucl Engn Inst IEN CNEN, Helio de Almeida St 75, BR-21941906 Rio De Janeiro, RJ, Brazil
2 shared publications - César Marques Salgado
Instituto de Engenharia Nuclear, CNEN/IEN, P.O. Box 68550, 21945-970, Rio de Janeiro, Brazil
2 shared publications Delson Braz
Univ Fed Rio de Janeiro, Nucl Engn Program, COPPE, Horacio Macedo Ave,2030 Block G, BR-21941914 Rio De Janeiro, RJ, Brazil
2 shared publications- Roos Sophia de Freitas Dam
Instituto de Engenharia Nuclear, Divisão de Radiofármacos (IEN / DIRAD), Rua Hélio de Almeida, 75, Cidade Universitária, RJ, 21941-906, Brazil
2 shared publications - William Luna Salgado
Inst Engn Nucl IEN, Rua Helio Almeida,75, BR-21941906 Rio De Janeiro, Brazil
2 shared publications
Latest Publications
- Open Access
- 13 February 2026
- Published by Elsevier in SSRN Electronic Journal
Thermophysical Characterization of Building Materials Due to Radioactive Decay
This study aims to provide a thermophysical characterization of crushed stone, sand, brick, and cement due to radioactive decay. The 28 sand samples, 23 cement samples, 30 crushed stone samples, and 29 brick samples were analyzed by X-Ray Fluorescence (XRF) and Scanning Electron Microscope (SEM) coupled with Energy-Dispersive X-ray Spectroscopy (EDS) to screen samples for the presence of uranium, potassium, and thorium. Also high-purity germanium (HPGe) gamma spectrometers were applied to estimate 226Ra (as a proxy for the 238U decay series), 40K, and 232Th contents in ppm and to evaluate heat generation generated in the samples. For the samples, 226Ra ranges from 0.68 ± 0.04 to 21.7 ± 0.47 ppm, 40K ranges from 428 ± 92 to 37172 ± 1651 ppm, and 232Th ranges from 0.86 ± 0.11 to 171 ± 0.24 ppm. 21 sand samples, 19 cement samples, 29 crushed stone and stone dust samples, and 13 brick samples presented values above the recommended average. The IH varied from 6.27×10-4 to 0.34, and the radiogenic heat production between the materials varied from 0.04 to 0.88 μW m-3, exceeding the average value of 0.5 μW m-3 observed by Hansi Junior & Kusznir (2025). The temperature generated (Ttrmc) due to the radioactive decay of these materials in use in a standard room in a house was 7.54×10-5 °C. The value of the thermal power generated in the wall, the heat generation produced by the consumed mass, the linear power density, and the heat flux that passes through the wall surface from these materials were 3.65 μW, 1.98 nW kg-1, 0.46 µW m-1 and 0.23 µW m-2, respectively. The primary chemical components in the samples media are SiO2, Fe2O3, K2O and Al2O3. The crystal structures of samples typically consist of alternating Si-O tetrahedral layers and Al-O octahedral layers. The findings from this research will be useful to assess the radiation hazards of building materials in humans.
- 13 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessThermophysical Characterization of Building Materials Due to Radioactive Decay
This study aims to provide a thermophysical characterization of crushed stone, sand, brick, and cement due to radioactive decay. The 28 sand samples, 23 cement samples, 30 crushed stone samples, and 29 brick samples were analyzed by X-Ray Fluorescence (XRF) and Scanning Electron Microscope (SEM) coupled with Energy-Dispersive X-ray Spectroscopy (EDS) to screen samples for the presence of uranium, potassium, and thorium. Also high-purity germanium (HPGe) gamma spectrometers were applied to estimate 226Ra (as a proxy for the 238U decay series), 40K, and 232Th contents in ppm and to evaluate heat generation generated in the samples. For the samples, 226Ra ranges from 0.68 ± 0.04 to 21.7 ± 0.47 ppm, 40K ranges from 428 ± 92 to 37172 ± 1651 ppm, and 232Th ranges from 0.86 ± 0.11 to 171 ± 0.24 ppm. 21 sand samples, 19 cement samples, 29 crushed stone and stone dust samples, and 13 brick samples presented values above the recommended average. The IH varied from 6.27×10-4 to 0.34, and the radiogenic heat production between the materials varied from 0.04 to 0.88 μW m-3, exceeding the average value of 0.5 μW m-3 observed by Hansi Junior & Kusznir (2025). The temperature generated (Ttrmc) due to the radioactive decay of these materials in use in a standard room in a house was 7.54×10-5 °C. The value of the thermal power generated in the wall, the heat generation produced by the consumed mass, the linear power density, and the heat flux that passes through the wall surface from these materials were 3.65 μW, 1.98 nW kg-1, 0.46 µW m-1 and 0.23 µW m-2, respectively. The primary chemical components in the samples media are SiO2, Fe2O3, K2O and Al2O3. The crystal structures of samples typically consist of alternating Si-O tetrahedral layers and Al-O octahedral layers. The findings from this research will be useful to assess the radiation hazards of building materials in humans.
- 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109784
Development of a non-invasive method for monitoring variations in salt concentrations of seawater using nuclear technique and Monte Carlo simulation
- 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109784
Development of a non-invasive method for monitoring variations in salt concentrations of seawater using nuclear technique and Monte Carlo simulation
- Open Access
- 30 April 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (1A)
USE OF MONTE CARLO SIMULATIONS FOR OPTIMAL GEOMETRY STUDY IN CALCULATION OF ATTENUATION COEFFICIENT FOR ELEMENT, COMPOUND AND MIXTURE
MCNP is a code extensively used to simulate experiments involving transport of radiation using the Monte Carlo method. This code allows the study of different geometries, materials, and radiation types (e.g. gamma, neutron, and electron), enabling the building of approximate models before the experimental implementation. The objective of this study is to develop an optimal geometry for the calculation of the mass attenuation coefficient for different materials using the MCNP code. Several measurement geometries were tested with different radiation energies, and the best results were obtained using lead collimators on both detector and radiation source. The considered geometries were isotropic source without any collimation, isotropic source with detector and/or source collimation, and a point source collimated into a cone of directions. The last case was proposed as a replacement for the computationally time expensive simulation of the two-collimator geometry. The energies 59.54 keV, 81 keV, 356 keV, and 662 keV were used to model 241Am, 133Ba, and 137Cs radiation sources, respectively. The materials were, NaI for the detector, aluminum, water, and sea water (3.5% NaCl) for the target sample, and lead for the collimators. The values of mass attenuation coefficient obtained from the simulations were compared with the theoretical NIST XCOM values for validation of the geometries.
- 30 April 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (1A)
Open AccessUSE OF MONTE CARLO SIMULATIONS FOR OPTIMAL GEOMETRY STUDY IN CALCULATION OF ATTENUATION COEFFICIENT FOR ELEMENT, COMPOUND AND MIXTURE
MCNP is a code extensively used to simulate experiments involving transport of radiation using the Monte Carlo method. This code allows the study of different geometries, materials, and radiation types (e.g. gamma, neutron, and electron), enabling the building of approximate models before the experimental implementation. The objective of this study is to develop an optimal geometry for the calculation of the mass attenuation coefficient for different materials using the MCNP code. Several measurement geometries were tested with different radiation energies, and the best results were obtained using lead collimators on both detector and radiation source. The considered geometries were isotropic source without any collimation, isotropic source with detector and/or source collimation, and a point source collimated into a cone of directions. The last case was proposed as a replacement for the computationally time expensive simulation of the two-collimator geometry. The energies 59.54 keV, 81 keV, 356 keV, and 662 keV were used to model 241Am, 133Ba, and 137Cs radiation sources, respectively. The materials were, NaI for the detector, aluminum, water, and sea water (3.5% NaCl) for the target sample, and lead for the collimators. The values of mass attenuation coefficient obtained from the simulations were compared with the theoretical NIST XCOM values for validation of the geometries.
- 1 November 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 165, 109332
Modeling of a neutron irradiator using Monte Carlo
- 1 November 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 165, 109332
Modeling of a neutron irradiator using Monte Carlo
- 1 October 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 164, 109226
Comparison between codes MCNPX and Gate/Geant4 in volume fraction studies
- 1 October 2020
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 164, 109226
Comparison between codes MCNPX and Gate/Geant4 in volume fraction studies