Cesar Raitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cesar Raitz has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Caroline Mattos Barbosa
Univ Fed Rio de Janeiro, Nucl Engn Program, COPPE, Horacio Macedo Ave,2030 Block G, BR-21941914 Rio De Janeiro, RJ, Brazil
2 shared publications Delson Braz
Univ Fed Rio de Janeiro, Nucl Engn Program, COPPE, Horacio Macedo Ave,2030 Block G, BR-21941914 Rio De Janeiro, RJ, Brazil
2 shared publications- William Luna Salgado
Inst Engn Nucl IEN, Rua Helio Almeida,75, BR-21941906 Rio De Janeiro, Brazil
2 shared publications - Bianca Tieppo1 shared publication
Camila M. Appolinário
1 shared publicationChristiano J.S. de Matos
1 shared publication
Latest Publications
- 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109784
Development of a non-invasive method for monitoring variations in salt concentrations of seawater using nuclear technique and Monte Carlo simulation
- 1 August 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 174, 109784
Development of a non-invasive method for monitoring variations in salt concentrations of seawater using nuclear technique and Monte Carlo simulation
- Open Access
- 30 April 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (1A)
USE OF MONTE CARLO SIMULATIONS FOR OPTIMAL GEOMETRY STUDY IN CALCULATION OF ATTENUATION COEFFICIENT FOR ELEMENT, COMPOUND AND MIXTURE
MCNP is a code extensively used to simulate experiments involving transport of radiation using the Monte Carlo method. This code allows the study of different geometries, materials, and radiation types (e.g. gamma, neutron, and electron), enabling the building of approximate models before the experimental implementation. The objective of this study is to develop an optimal geometry for the calculation of the mass attenuation coefficient for different materials using the MCNP code. Several measurement geometries were tested with different radiation energies, and the best results were obtained using lead collimators on both detector and radiation source. The considered geometries were isotropic source without any collimation, isotropic source with detector and/or source collimation, and a point source collimated into a cone of directions. The last case was proposed as a replacement for the computationally time expensive simulation of the two-collimator geometry. The energies 59.54 keV, 81 keV, 356 keV, and 662 keV were used to model 241Am, 133Ba, and 137Cs radiation sources, respectively. The materials were, NaI for the detector, aluminum, water, and sea water (3.5% NaCl) for the target sample, and lead for the collimators. The values of mass attenuation coefficient obtained from the simulations were compared with the theoretical NIST XCOM values for validation of the geometries.
- 30 April 2021
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 9 (1A)
Open AccessUSE OF MONTE CARLO SIMULATIONS FOR OPTIMAL GEOMETRY STUDY IN CALCULATION OF ATTENUATION COEFFICIENT FOR ELEMENT, COMPOUND AND MIXTURE
MCNP is a code extensively used to simulate experiments involving transport of radiation using the Monte Carlo method. This code allows the study of different geometries, materials, and radiation types (e.g. gamma, neutron, and electron), enabling the building of approximate models before the experimental implementation. The objective of this study is to develop an optimal geometry for the calculation of the mass attenuation coefficient for different materials using the MCNP code. Several measurement geometries were tested with different radiation energies, and the best results were obtained using lead collimators on both detector and radiation source. The considered geometries were isotropic source without any collimation, isotropic source with detector and/or source collimation, and a point source collimated into a cone of directions. The last case was proposed as a replacement for the computationally time expensive simulation of the two-collimator geometry. The energies 59.54 keV, 81 keV, 356 keV, and 662 keV were used to model 241Am, 133Ba, and 137Cs radiation sources, respectively. The materials were, NaI for the detector, aluminum, water, and sea water (3.5% NaCl) for the target sample, and lead for the collimators. The values of mass attenuation coefficient obtained from the simulations were compared with the theoretical NIST XCOM values for validation of the geometries.
- 15 July 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 78 (1) , 012326
Quantum random walks and wave-packet reshaping at the single-photon level
We realize an experimental implementation of one step of a quantum random walk at the single-photon level. After a single step, it is already possible to observe the difference between the quantum and classical random walk. The single photon is obtained using twin photons from parametric down-conversion, in which the detection of one photon of the idler prepares a single-photon state of the signal. We used two different experimental setups, one based on an interferometer and a second using a birefringent crystal. The physical process behind these effects is the spatial reshaping of the single-photon wave packet, which is the spatial analog of the time reshaping observed in tunneling experiments.
- 15 July 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 78 (1) , 012326
Quantum random walks and wave-packet reshaping at the single-photon level
We realize an experimental implementation of one step of a quantum random walk at the single-photon level. After a single step, it is already possible to observe the difference between the quantum and classical random walk. The single photon is obtained using twin photons from parametric down-conversion, in which the detection of one photon of the idler prepares a single-photon state of the signal. We used two different experimental setups, one based on an interferometer and a second using a birefringent crystal. The physical process behind these effects is the spatial reshaping of the single-photon wave packet, which is the spatial analog of the time reshaping observed in tunneling experiments.