Xie George Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xie George Xu has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
Tianyu Liu
Nuclear Engineering, Rensselaer Polytechnic Institute, 110 8th Street, Troy, NY, 12180, USA
10 shared publicationsBryan Bednarz
Department of Medical Physics, University of Wisconsin, Madision, WI, 53705
6 shared publicationsJuying Zhang
Radiation Oncology Department, University of California, Irvine, Orange, CA 92868,USA
5 shared publicationsLin Su
Radiation Oncology, John Hopkins University, Baltimore, MD , USA, 21218
5 shared publications- Bin Han
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA
4 shared publications Bob Liu
Department of Radiology Massachusetts General Hospital Boston MA USA
4 shared publications
Latest Publications
- 16 March 2020
- Published by Wiley in Medical Physics
- Vol. 47 (6) , 2537-2549
New capabilities of the Monte Carlo dose engine ARCHER‐RT: Clinical validation of the Varian TrueBeam machine for VMAT external beam radiotherapy
Purpose: The Monte Carlo radiation transport method is considered the most accurate approach for absorbed dose calculations in external beam radiation therapy. In this study, an efficient and accurate source model of the Varian TrueBeam 6X STx Linac is developed and integrated with a fast Monte Carlo photon‐electron transport absorbed dose engine, ARCHER‐RT, which is capable of being executed on CPUs, NVIDIA GPUs, and AMD GPUs. This capability of fast yet accurate radiation dose calculation is essential for clinical utility of this new technology. This paper describes the software and algorithmic developments made to the ARCHER‐RT absorbed dose engine.Methods: AMD’s Heterogeneous‐Compute Interface for Portability (HIP) was implemented in ARCHER‐RT to allow for device independent execution on NVIDIA and AMD GPUs. Architecture‐specific atomic‐add algorithms have been identified and both more accurate single‐precision and double‐precision computational absorbed dose calculation methods have been added to ARCHER‐RT and validated through a test case to evaluate the accuracy and performance of the algorithms. The validity of the source model and the radiation transport physics were benchmarked against Monte Carlo simulations performed with EGSnrc. Secondary dose‐check physics plans, and a clinical prostate treatment plan were calculated to demonstrate the applicability of the platform for clinical use. Absorbed dose difference maps and gamma analyses were conducted to establish the accuracy and consistency between the two Monte Carlo models. Timing studies were conducted on a CPU, an NVIDIA GPU, and an AMD GPU to evaluate the computational speed of ARCHER‐RT.Results: Percent depth doses were computed for different field sizes ranging from 1.5 cm2 × 1.5 cm2 to 22 cm2 × 40cm2 and the two codes agreed for all points outside high gradient regions within 3%. Axial profiles computed for a 10 cm2 × 10 cm2 field for multiple depths agreed for all points outside high gradient regions within 2%. The test case investigating the impact of native single‐precision compared to double‐precision showed differences in voxels as large as 71.47% and the implementation of KAS single‐precision reduced the difference to less than 0.01%. The 3%/3mm gamma pass rates for an MPPG5a multileaf collimator (MLC) test case and a clinical VMAT prostate plan were 94.2% and 98.4% respectively. Timing studies demonstrated the calculation of a VMAT plan was completed in 50.3, 187.9, and 216.8 s on an NVIDIA GPU, AMD GPU, and Intel CPU, respectively.Conclusion: ARCHER‐RT is capable of patient‐specific VMAT external beam photon absorbed dose calculations and its potential has been demonstrated by benchmarking against a well validated EGSnrc model of a Varian TrueBeam. Additionally, the implementation of AMD’s HIP has shown the flexibility of the ARCHER‐RT platform for device independent calculations. This work demonstrates the significant addition of functionality added to ARCHER‐RT framework which has marked utility for both research and clinical applications and demonstrates further that Monte Carlo‐based absorbed dose engines like ARCHER‐RT have the potential for widespread clinical implementation.
- 16 March 2020
- Published by Wiley in Medical Physics
- Vol. 47 (6) , 2537-2549
New capabilities of the Monte Carlo dose engine ARCHER‐RT: Clinical validation of the Varian TrueBeam machine for VMAT external beam radiotherapy
Purpose: The Monte Carlo radiation transport method is considered the most accurate approach for absorbed dose calculations in external beam radiation therapy. In this study, an efficient and accurate source model of the Varian TrueBeam 6X STx Linac is developed and integrated with a fast Monte Carlo photon‐electron transport absorbed dose engine, ARCHER‐RT, which is capable of being executed on CPUs, NVIDIA GPUs, and AMD GPUs. This capability of fast yet accurate radiation dose calculation is essential for clinical utility of this new technology. This paper describes the software and algorithmic developments made to the ARCHER‐RT absorbed dose engine.Methods: AMD’s Heterogeneous‐Compute Interface for Portability (HIP) was implemented in ARCHER‐RT to allow for device independent execution on NVIDIA and AMD GPUs. Architecture‐specific atomic‐add algorithms have been identified and both more accurate single‐precision and double‐precision computational absorbed dose calculation methods have been added to ARCHER‐RT and validated through a test case to evaluate the accuracy and performance of the algorithms. The validity of the source model and the radiation transport physics were benchmarked against Monte Carlo simulations performed with EGSnrc. Secondary dose‐check physics plans, and a clinical prostate treatment plan were calculated to demonstrate the applicability of the platform for clinical use. Absorbed dose difference maps and gamma analyses were conducted to establish the accuracy and consistency between the two Monte Carlo models. Timing studies were conducted on a CPU, an NVIDIA GPU, and an AMD GPU to evaluate the computational speed of ARCHER‐RT.Results: Percent depth doses were computed for different field sizes ranging from 1.5 cm2 × 1.5 cm2 to 22 cm2 × 40cm2 and the two codes agreed for all points outside high gradient regions within 3%. Axial profiles computed for a 10 cm2 × 10 cm2 field for multiple depths agreed for all points outside high gradient regions within 2%. The test case investigating the impact of native single‐precision compared to double‐precision showed differences in voxels as large as 71.47% and the implementation of KAS single‐precision reduced the difference to less than 0.01%. The 3%/3mm gamma pass rates for an MPPG5a multileaf collimator (MLC) test case and a clinical VMAT prostate plan were 94.2% and 98.4% respectively. Timing studies demonstrated the calculation of a VMAT plan was completed in 50.3, 187.9, and 216.8 s on an NVIDIA GPU, AMD GPU, and Intel CPU, respectively.Conclusion: ARCHER‐RT is capable of patient‐specific VMAT external beam photon absorbed dose calculations and its potential has been demonstrated by benchmarking against a well validated EGSnrc model of a Varian TrueBeam. Additionally, the implementation of AMD’s HIP has shown the flexibility of the ARCHER‐RT platform for device independent calculations. This work demonstrates the significant addition of functionality added to ARCHER‐RT framework which has marked utility for both research and clinical applications and demonstrates further that Monte Carlo‐based absorbed dose engines like ARCHER‐RT have the potential for widespread clinical implementation.
- Open Access
- 10 March 2020
- Published by Wiley in Medical Physics
- Vol. 47 (6) , 2526-2536
A method of rapid quantification of patient‐specific organ doses for CT using deep‐learning‐based multi‐organ segmentation and GPU‐accelerated Monte Carlo dose computing
Purpose: One technical barrier to patient‐specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient‐specific multi‐organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the ability to obtain patient‐specific organ doses for CT — in a similar manner as radiation therapy treatment planning — will open the door to personalized and prospective CT scan protocols. This study aims to demonstrate the feasibility of combining deep‐learning algorithms for automatic segmentation of multiple radiosensitive organs from CT images with the GPU‐based Monte Carlo rapid organ dose calculation.Methods: A deep convolutional neural network (CNN) based on the U‐Net for organ segmentation is developed and trained to automatically delineate multiple radiosensitive organs from CT images. Two databases are used: The lung CT segmentation challenge 2017 (LCTSC) dataset that contains 60 thoracic CT scan patients, each consisting of five segmented organs, and the Pancreas‐CT (PCT) dataset, which contains 43 abdominal CT scan patients each consisting of eight segmented organs. A fivefold cross‐validation method is performed on both sets of data. Dice similarity coefficients (DSCs) are used to evaluate the segmentation performance against the ground truth. A GPU‐based Monte Carlo dose code, ARCHER, is used to calculate patient‐specific CT organ doses. The proposed method is evaluated in terms of relative dose errors (RDEs). To demonstrate the potential improvement of the new method, organ dose results are compared against those obtained for population‐average patient phantoms used in an off‐line dose reporting software, VirtualDose, at Massachusetts General Hospital.Results: The median DSCs are found to be 0.97 (right lung), 0.96 (left lung), 0.92 (heart), 0.86 (spinal cord), 0.76 (esophagus) for the LCTSC dataset, along with 0.96 (spleen), 0.96 (liver), 0.95 (left kidney), 0.90 (stomach), 0.87 (gall bladder), 0.80 (pancreas), 0.75 (esophagus), and 0.61 (duodenum) for the PCT dataset. Comparing with organ dose results from population‐averaged phantoms, the new patient‐specific method achieved smaller absolute RDEs (mean ± standard deviation) for all organs: 1.8% ± 1.4% (vs 16.0% ± 11.8%) for the lung, 0.8% ± 0.7% (vs 34.0% ± 31.1%) for the heart, 1.6% ± 1.7% (vs 45.7% ± 29.3%) for the esophagus, 0.6% ± 1.2% (vs 15.8% ± 12.7%) for the spleen, 1.2% ± 1.0% (vs 18.1% ± 15.7%) for the pancreas, 0.9% ± 0.6% (vs 20.0% ± 15.2%) for the left kidney, 1.7% ± 3.1% (vs 19.1% ± 9.8%) for the gallbladder, 0.3% ± 0.3% (vs 24.2% ± 18.7%) for the liver, and 1.6% ± 1.7% (vs 19.3% ± 13.6%) for the stomach. The trained automatic segmentation tool takes <5 s per patient for all 103 patients in the dataset. The Monte Carlo radiation dose calculations performed in parallel to the segmentation process using the GPU‐accelerated ARCHER code take <4 s per patient to achieve <0.5% statistical uncertainty in all organ doses for all 103 patients in the database.Conclusion: This work shows the feasibility to perform combined automatic patient‐specific multi‐organ segmentation of CT images and rapid GPU‐based Monte Carlo dose quantification with clinically acceptable accuracy and efficiency.
- 10 March 2020
- Published by Wiley in Medical Physics
- Vol. 47 (6) , 2526-2536
Open AccessA method of rapid quantification of patient‐specific organ doses for CT using deep‐learning‐based multi‐organ segmentation and GPU‐accelerated Monte Carlo dose computing
Purpose: One technical barrier to patient‐specific computed tomography (CT) dosimetry has been the lack of computational tools for the automatic patient‐specific multi‐organ segmentation of CT images and rapid organ dose quantification. When previous CT images are available for the same body region of the patient, the ability to obtain patient‐specific organ doses for CT — in a similar manner as radiation therapy treatment planning — will open the door to personalized and prospective CT scan protocols. This study aims to demonstrate the feasibility of combining deep‐learning algorithms for automatic segmentation of multiple radiosensitive organs from CT images with the GPU‐based Monte Carlo rapid organ dose calculation.Methods: A deep convolutional neural network (CNN) based on the U‐Net for organ segmentation is developed and trained to automatically delineate multiple radiosensitive organs from CT images. Two databases are used: The lung CT segmentation challenge 2017 (LCTSC) dataset that contains 60 thoracic CT scan patients, each consisting of five segmented organs, and the Pancreas‐CT (PCT) dataset, which contains 43 abdominal CT scan patients each consisting of eight segmented organs. A fivefold cross‐validation method is performed on both sets of data. Dice similarity coefficients (DSCs) are used to evaluate the segmentation performance against the ground truth. A GPU‐based Monte Carlo dose code, ARCHER, is used to calculate patient‐specific CT organ doses. The proposed method is evaluated in terms of relative dose errors (RDEs). To demonstrate the potential improvement of the new method, organ dose results are compared against those obtained for population‐average patient phantoms used in an off‐line dose reporting software, VirtualDose, at Massachusetts General Hospital.Results: The median DSCs are found to be 0.97 (right lung), 0.96 (left lung), 0.92 (heart), 0.86 (spinal cord), 0.76 (esophagus) for the LCTSC dataset, along with 0.96 (spleen), 0.96 (liver), 0.95 (left kidney), 0.90 (stomach), 0.87 (gall bladder), 0.80 (pancreas), 0.75 (esophagus), and 0.61 (duodenum) for the PCT dataset. Comparing with organ dose results from population‐averaged phantoms, the new patient‐specific method achieved smaller absolute RDEs (mean ± standard deviation) for all organs: 1.8% ± 1.4% (vs 16.0% ± 11.8%) for the lung, 0.8% ± 0.7% (vs 34.0% ± 31.1%) for the heart, 1.6% ± 1.7% (vs 45.7% ± 29.3%) for the esophagus, 0.6% ± 1.2% (vs 15.8% ± 12.7%) for the spleen, 1.2% ± 1.0% (vs 18.1% ± 15.7%) for the pancreas, 0.9% ± 0.6% (vs 20.0% ± 15.2%) for the left kidney, 1.7% ± 3.1% (vs 19.1% ± 9.8%) for the gallbladder, 0.3% ± 0.3% (vs 24.2% ± 18.7%) for the liver, and 1.6% ± 1.7% (vs 19.3% ± 13.6%) for the stomach. The trained automatic segmentation tool takes <5 s per patient for all 103 patients in the dataset. The Monte Carlo radiation dose calculations performed in parallel to the segmentation process using the GPU‐accelerated ARCHER code take <4 s per patient to achieve <0.5% statistical uncertainty in all organ doses for all 103 patients in the database.Conclusion: This work shows the feasibility to perform combined automatic patient‐specific multi‐organ segmentation of CT images and rapid GPU‐based Monte Carlo dose quantification with clinically acceptable accuracy and efficiency.
- Open Access
A Method of Rapid Quantification of Patient-Specific Organ Dose for CT Using Coupled Deep-Learning based Multi-Organ Segmentation and GPU-accelerated Monte Carlo Dose Computing
Purpose: This paper describes a new method to apply deep-learning algorithms for automatic segmentation of radiosensitive organs from 3D tomographic CT images before computing organ doses using a GPU-based Monte Carlo code. Methods: A deep convolutional neural network (CNN) for organ segmentation is trained to automatically delineate radiosensitive organs from CT. With a GPU-based Monte Carlo dose engine (ARCHER) to derive CT dose of a phantom made from a subject's CT scan, we are then able to compute the patient-specific CT dose for each of the segmented organs. The developed tool is validated by using Relative Dose Error (RDE) against the organ doses calculated by ARCHER with manual segmentation performed by radiologists. The dose computation results are also compared against organ doses from population-average phantoms to demonstrate the improvement achieved by using the developed tool. In this study, two datasets were used: The Lung CT Segmentation Challenge 2017 (LCTSC) dataset, which contains 60 thoracic CT scan patients each with 5 segmented organs, and the Pancreas-CT (PCT) dataset, which contains 43 abdominal CT scan patients each with 8 segmented organs. Five-fold cross-validation of the new method is performed on both datasets. Results: Comparing with the traditional organ dose evaluation method that based on population-average phantom, our proposed method achieved the smaller RDE range on all organs with -4.3%~1.5% vs -31.5%~33.9% (lung), -7.0%~2.3% vs -15.2%~125.1% (heart), -18.8%~40.2% vs -10.3%~124.1% (esophagus) in the LCTSC dataset and -5.6%~1.6% vs -20.3%~57.4% (spleen), -4.5%~4.6% vs -19.5%~61.0% (pancreas), -2.3%~4.4% vs -37.8%~75.8% (left kidney), -14.9%~5.4% vs -39.9% ~14.6% (gall bladder), -0.9%~1.6% vs -30.1%~72.5% (liver), and -23.0%~11.1% vs -52.5%~-1.3% (stomach) in the PCT dataset.
Open AccessA Method of Rapid Quantification of Patient-Specific Organ Dose for CT Using Coupled Deep-Learning based Multi-Organ Segmentation and GPU-accelerated Monte Carlo Dose Computing
Purpose: This paper describes a new method to apply deep-learning algorithms for automatic segmentation of radiosensitive organs from 3D tomographic CT images before computing organ doses using a GPU-based Monte Carlo code. Methods: A deep convolutional neural network (CNN) for organ segmentation is trained to automatically delineate radiosensitive organs from CT. With a GPU-based Monte Carlo dose engine (ARCHER) to derive CT dose of a phantom made from a subject's CT scan, we are then able to compute the patient-specific CT dose for each of the segmented organs. The developed tool is validated by using Relative Dose Error (RDE) against the organ doses calculated by ARCHER with manual segmentation performed by radiologists. The dose computation results are also compared against organ doses from population-average phantoms to demonstrate the improvement achieved by using the developed tool. In this study, two datasets were used: The Lung CT Segmentation Challenge 2017 (LCTSC) dataset, which contains 60 thoracic CT scan patients each with 5 segmented organs, and the Pancreas-CT (PCT) dataset, which contains 43 abdominal CT scan patients each with 8 segmented organs. Five-fold cross-validation of the new method is performed on both datasets. Results: Comparing with the traditional organ dose evaluation method that based on population-average phantom, our proposed method achieved the smaller RDE range on all organs with -4.3%~1.5% vs -31.5%~33.9% (lung), -7.0%~2.3% vs -15.2%~125.1% (heart), -18.8%~40.2% vs -10.3%~124.1% (esophagus) in the LCTSC dataset and -5.6%~1.6% vs -20.3%~57.4% (spleen), -4.5%~4.6% vs -19.5%~61.0% (pancreas), -2.3%~4.4% vs -37.8%~75.8% (left kidney), -14.9%~5.4% vs -39.9% ~14.6% (gall bladder), -0.9%~1.6% vs -30.1%~72.5% (liver), and -23.0%~11.1% vs -52.5%~-1.3% (stomach) in the PCT dataset.
- 7 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (6) , 2744-2751
Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study
Purpose: To quantify the effects of operator head posture and different types of protective eyewear on the eye lens dose to operators in interventional radiology (IR).Methods: A deformable computational human phantom, Rensselaer Polytechnic Institute (RPI) Adult Male, consisting of a high‐resolution eye model, was used to simulate a radiologist who is performing an interventional radiology procedure. The radiologist phantom was deformed to a set of different head postures. Three different protective eyewear models were incorporated into the posture‐deformed radiologist phantom. The eye lens dose of the radiologist was calculated using the Monte Carlo code, MCNP. Effects of the radiologist's head posture and different types of protective eyewear on eye lens doses were studied. The relationship between efficacy of protective eyewear and the radiologist's head posture was investigated. Effects of other parameters on efficacy of protective eyewear were also studied, including the angular position of the radiologist, the gap between the eyewear and the face of the radiologist, and the lead equivalent thickness.Results: The dose to both lenses decreased by 80% as the head posture moved from looking downward to looking upward. Sports wrap glasses were found to reduce doses further than the other two studied models. The efficacy of eyewear was found to be related to radiologist's head posture as well. When the radiologist was looking up, the protective eyewear almost provided no protection to both lenses. Other factors such as the face‐to‐eyewear distance and the lead equivalent thickness were also found to have an impact on the efficacy of protective eyewear. The dose reduction factor (DRF), defined as the ratio of the dose to the lens without protection to that with protection, decreased from 4.25 to 1.07 as the face‐to‐eyewear distance increased. The DRF almost doubled when the lead equivalent thickness increased from 0.07 to 0.35 mm. However, further increase in lead equivalent thickness showed little improvement in dose reduction.Conclusion: The radiologist's head posture has a significant influence on the eye lens dose in IR. Sports wrap protective eyewear which conforms to the curve of the face is essential for the radiation protection of the eye lens. However, the radiologist's head posture and other exposure parameters should be considered when evaluating the protection of the radiologist's eyes.
- 7 April 2019
- Published by Wiley in Medical Physics
- Vol. 46 (6) , 2744-2751
Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study
Purpose: To quantify the effects of operator head posture and different types of protective eyewear on the eye lens dose to operators in interventional radiology (IR).Methods: A deformable computational human phantom, Rensselaer Polytechnic Institute (RPI) Adult Male, consisting of a high‐resolution eye model, was used to simulate a radiologist who is performing an interventional radiology procedure. The radiologist phantom was deformed to a set of different head postures. Three different protective eyewear models were incorporated into the posture‐deformed radiologist phantom. The eye lens dose of the radiologist was calculated using the Monte Carlo code, MCNP. Effects of the radiologist's head posture and different types of protective eyewear on eye lens doses were studied. The relationship between efficacy of protective eyewear and the radiologist's head posture was investigated. Effects of other parameters on efficacy of protective eyewear were also studied, including the angular position of the radiologist, the gap between the eyewear and the face of the radiologist, and the lead equivalent thickness.Results: The dose to both lenses decreased by 80% as the head posture moved from looking downward to looking upward. Sports wrap glasses were found to reduce doses further than the other two studied models. The efficacy of eyewear was found to be related to radiologist's head posture as well. When the radiologist was looking up, the protective eyewear almost provided no protection to both lenses. Other factors such as the face‐to‐eyewear distance and the lead equivalent thickness were also found to have an impact on the efficacy of protective eyewear. The dose reduction factor (DRF), defined as the ratio of the dose to the lens without protection to that with protection, decreased from 4.25 to 1.07 as the face‐to‐eyewear distance increased. The DRF almost doubled when the lead equivalent thickness increased from 0.07 to 0.35 mm. However, further increase in lead equivalent thickness showed little improvement in dose reduction.Conclusion: The radiologist's head posture has a significant influence on the eye lens dose in IR. Sports wrap protective eyewear which conforms to the curve of the face is essential for the radiation protection of the eye lens. However, the radiologist's head posture and other exposure parameters should be considered when evaluating the protection of the radiologist's eyes.
- 1 February 2019
- Published by Wolters Kluwer Health in Health Physics
- Vol. 116 (2) , 263-275
Innovations in Computer Technologies Have Impacted Radiation Dosimetry Through Anatomically Realistic Phantoms and Fast Monte Carlo Simulations
Radiological physics principles have not changed in the past 60 y when computer technologies advanced exponentially. The research field of anatomical modeling for the purpose of radiation dose calculations has experienced an explosion in activity in the past two decades. Such an exciting advancement is due to the feasibility of creating three-dimensional geometric details of the human anatomy from tomographic imaging and of performing Monte Carlo radiation transport simulations on increasingly fast and cheap personal computers. The advent of a new type of high-performance computing hardware in recent years—graphics processing units—has made it feasible to carry out time-consuming Monte Carlo calculations at near real-time speeds. This paper introduces the history of three generations of computational human phantoms (the stylized medical internal radiation dosimetry-type phantoms, the voxelized tomographic phantoms, and the boundary representation deformable phantoms) and new development of the graphics processing unit-based Monte Carlo radiation dose calculations. Examples are given for research projects performed by my students in applying computational phantoms and a new Monte Carlo code, ARCHER, to problems in radiation protection, imaging, and radiotherapy. Finally, the paper discusses challenges and future opportunities for research.
- 1 February 2019
- Published by Wolters Kluwer Health in Health Physics
- Vol. 116 (2) , 263-275
Innovations in Computer Technologies Have Impacted Radiation Dosimetry Through Anatomically Realistic Phantoms and Fast Monte Carlo Simulations
Radiological physics principles have not changed in the past 60 y when computer technologies advanced exponentially. The research field of anatomical modeling for the purpose of radiation dose calculations has experienced an explosion in activity in the past two decades. Such an exciting advancement is due to the feasibility of creating three-dimensional geometric details of the human anatomy from tomographic imaging and of performing Monte Carlo radiation transport simulations on increasingly fast and cheap personal computers. The advent of a new type of high-performance computing hardware in recent years—graphics processing units—has made it feasible to carry out time-consuming Monte Carlo calculations at near real-time speeds. This paper introduces the history of three generations of computational human phantoms (the stylized medical internal radiation dosimetry-type phantoms, the voxelized tomographic phantoms, and the boundary representation deformable phantoms) and new development of the graphics processing unit-based Monte Carlo radiation dose calculations. Examples are given for research projects performed by my students in applying computational phantoms and a new Monte Carlo code, ARCHER, to problems in radiation protection, imaging, and radiotherapy. Finally, the paper discusses challenges and future opportunities for research.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (1) , 1-23
Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering—A Topical Review
Over the past decades, significant improvements have been made in the field of computational human phantoms (CHPs) and their applications in biomedical engineering. Their sophistication has dramatically increased. The very first CHPs were composed of simple geometric volumes, e.g., cylinders and spheres, while current CHPs have a high resolution, cover a substantial range of the patient population, have high anatomical accuracy, are poseable, morphable, and are augmented with various details to perform functionalized computations. Advances in imaging techniques and semiautomated segmentation tools allow fast and personalized development of CHPs. These advances open the door to quickly develop personalized CHPs, inherently including the disease of the patient. Because many of these CHPs are increasingly providing data for regulatory submissions of various medical devices, the validity, anatomical accuracy, and availability to cover the entire patient population is of utmost importance. This paper is organized into two main sections: the first section reviews the different modeling techniques used to create CHPs, whereas the second section discusses various applications of CHPs in biomedical engineering. Each topic gives an overview, a brief history, recent developments, and an outlook into the future.
- 1 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 3 (1) , 1-23
Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering—A Topical Review
Over the past decades, significant improvements have been made in the field of computational human phantoms (CHPs) and their applications in biomedical engineering. Their sophistication has dramatically increased. The very first CHPs were composed of simple geometric volumes, e.g., cylinders and spheres, while current CHPs have a high resolution, cover a substantial range of the patient population, have high anatomical accuracy, are poseable, morphable, and are augmented with various details to perform functionalized computations. Advances in imaging techniques and semiautomated segmentation tools allow fast and personalized development of CHPs. These advances open the door to quickly develop personalized CHPs, inherently including the disease of the patient. Because many of these CHPs are increasingly providing data for regulatory submissions of various medical devices, the validity, anatomical accuracy, and availability to cover the entire patient population is of utmost importance. This paper is organized into two main sections: the first section reviews the different modeling techniques used to create CHPs, whereas the second section discusses various applications of CHPs in biomedical engineering. Each topic gives an overview, a brief history, recent developments, and an outlook into the future.
- Open Access
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 146-155
Patient-specific organ and effective dose estimates in pediatric oncology computed tomography
- 1 January 2018
- Published by Elsevier in Physica Medica
- Vol. 45, 146-155
Open AccessPatient-specific organ and effective dose estimates in pediatric oncology computed tomography
- Open Access
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 04010
Modeling of Radiotherapy Linac Source Terms Using ARCHER Monte Carlo Code: Performance Comparison for GPU and MIC Parallel Computing Devices
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 04010
Open AccessModeling of Radiotherapy Linac Source Terms Using ARCHER Monte Carlo Code: Performance Comparison for GPU and MIC Parallel Computing Devices
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- Open Access
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 04016
Monte Carlo calculations for reporting patient organ doses from interventional radiology
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 04016
Open AccessMonte Carlo calculations for reporting patient organ doses from interventional radiology
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- Open Access
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 06022
Performance Study of Monte Carlo Codes on Xeon Phi Coprocessors — Testing MCNP 6.1 and Profiling ARCHER Geometry Module on the FS7ONNi Problem
EPJ Web of Conferences, open-access proceedings in physics and astronomy
- 25 September 2017
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 153, 06022
Open AccessPerformance Study of Monte Carlo Codes on Xeon Phi Coprocessors — Testing MCNP 6.1 and Profiling ARCHER Geometry Module on the FS7ONNi Problem
EPJ Web of Conferences, open-access proceedings in physics and astronomy