Fan-Yu Kong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fan-Yu Kong has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Jiaqiong Wang
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
3 shared publications - Ning Qiu
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang, 212013, China
3 shared publications - Sun-Sheng Yang
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
3 shared publications - Zhenfa Xu
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
3 shared publications - Houlin Liu
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
2 shared publications - Kun Zhang
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University, Zhenjiang 212013, China
2 shared publications
Latest Publications
- Open Access
Internal Flow Field and Loss Analysis of a Magnetic Drive Pump’s Cooling Circuit
The cooling circuit is an important component of the magnetic drive pump because it prevents demagnetization of the permanent magnet and damage to the containment shell owing to a high temperature increase. In this paper, the flow field and losses of the cooling circuit of the magnetic pump are discussed and experimentally verified based on numerical simulation methods. Five different lengths of magnetic couplings were designed, and the flow field distribution, cooling flow rate, and loss variation laws of the cooling circuit were analyzed. The results show that the pump flow rate and magnetic coupling length have a minimal effect on the velocity distribution in the cooling circuit. When the magnet length increases from 30 mm to 55 mm, the temperature rise of the cooling circuit and the pressure drop at the gap increase by 23.1% and 25.3%, respectively. When the length of the magnetic coupling remains constant, the cooling flow rate of the cooling circuit falls with an increasing pump flow rate, and it reduces by 8.4% when the pump flow rate increases from 0.7 Q to 1.3 Q. The water friction loss and eddy current loss of the cooling circuit increase with an increase in the magnetic coupling length, while the cooling flow rate decreases. When the magnet length increases from 30 mm to 55 mm, the eddy current losses in the coupling circuit and the water friction losses in the cooling circuit increase by 45% and 35%, respectively, while the cooling flow rate decreases by 13%.
Open AccessInternal Flow Field and Loss Analysis of a Magnetic Drive Pump’s Cooling Circuit
The cooling circuit is an important component of the magnetic drive pump because it prevents demagnetization of the permanent magnet and damage to the containment shell owing to a high temperature increase. In this paper, the flow field and losses of the cooling circuit of the magnetic pump are discussed and experimentally verified based on numerical simulation methods. Five different lengths of magnetic couplings were designed, and the flow field distribution, cooling flow rate, and loss variation laws of the cooling circuit were analyzed. The results show that the pump flow rate and magnetic coupling length have a minimal effect on the velocity distribution in the cooling circuit. When the magnet length increases from 30 mm to 55 mm, the temperature rise of the cooling circuit and the pressure drop at the gap increase by 23.1% and 25.3%, respectively. When the length of the magnetic coupling remains constant, the cooling flow rate of the cooling circuit falls with an increasing pump flow rate, and it reduces by 8.4% when the pump flow rate increases from 0.7 Q to 1.3 Q. The water friction loss and eddy current loss of the cooling circuit increase with an increase in the magnetic coupling length, while the cooling flow rate decreases. When the magnet length increases from 30 mm to 55 mm, the eddy current losses in the coupling circuit and the water friction losses in the cooling circuit increase by 45% and 35%, respectively, while the cooling flow rate decreases by 13%.
- Open Access
Effect of Blade Thickness on Internal Flow and Performance of a Plastic Centrifugal Pump
Blade thickness is an essential parameter of the impeller, which has significant effects on the pump performance. The plastic pump generally adopts thick blade due to low strength of plastic. The effects of blade thickness on the internal flow and performance of a plastic centrifugal pump were discussed based on the numerical methods. Two kinds of blade profile, the constant thickness blade (CTB) and the variable thickness blade (VTB), were investigated. The results indicated that, for the CTB, when the blade thickness was less than 6 mm, the pump performance did not change significantly. When the blade thickness exceeded 6 mm, the pump head and efficiency decreased rapidly. The pump head and efficiency of CTB 10 decreased by 42.2% and 30% compared with CTB 4, respectively. For the VTB, with blade thickness in a certain range (6 mm–14 mm), the pump performance changed slightly with the increased of trailing edge thickness. The minimum blade thickness of the plastic centrifugal pump should be 4 mm based on the finite element analysis. A variable thickness blade (VTB 4-8-4) with the maximum thickness located at 60% chord length was proposed to improve the pump performance, and its efficiency was 1.67% higher than that of the CTB 4 impeller.
Open AccessEffect of Blade Thickness on Internal Flow and Performance of a Plastic Centrifugal Pump
Blade thickness is an essential parameter of the impeller, which has significant effects on the pump performance. The plastic pump generally adopts thick blade due to low strength of plastic. The effects of blade thickness on the internal flow and performance of a plastic centrifugal pump were discussed based on the numerical methods. Two kinds of blade profile, the constant thickness blade (CTB) and the variable thickness blade (VTB), were investigated. The results indicated that, for the CTB, when the blade thickness was less than 6 mm, the pump performance did not change significantly. When the blade thickness exceeded 6 mm, the pump head and efficiency decreased rapidly. The pump head and efficiency of CTB 10 decreased by 42.2% and 30% compared with CTB 4, respectively. For the VTB, with blade thickness in a certain range (6 mm–14 mm), the pump performance changed slightly with the increased of trailing edge thickness. The minimum blade thickness of the plastic centrifugal pump should be 4 mm based on the finite element analysis. A variable thickness blade (VTB 4-8-4) with the maximum thickness located at 60% chord length was proposed to improve the pump performance, and its efficiency was 1.67% higher than that of the CTB 4 impeller.
- Open Access
- 8 November 2021
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 9 (11) , 1240
Research on Visualization of Inducer Cavitation of High-Speed Centrifugal Pump in Low Flow Conditions
Inducer is often used to improve the cavitation performance of pump. In order to study the cavitation characteristics of inducer under low flow condition of high-speed pump, high-speed photography technology was employed in this paper to carry out visual experiments on the inducer of a high-speed centrifugal pump. In low flow rates, Cavitation distribution and evolution among the inducer were captured. The experimental results revealed that a band-shaped backflow vortex in the inlet pipe would occur when the flow rate was less than 0.3 Qd. Moreover, the backflow vortex in the inlet pipe rotated with the inducer and the rotational speed of backflow vortex was approximately half of the inducer. The visualization test of 0.27 Qd was carried out: when the NPSH was greater than 6.72 m, the bubbles in the inlet pipe were asymmetrical; When the NPSH dropped to 5.41 m, the cavitation was becoming less asymmetrical; When NPSH dropped to 3.81 m, cavitation evolved to the deteriorating stage, plenty of bubbles entered into the main impeller, resulting in a rapid decline of pump performance. Furthermore, the cavitation performance was worse at an extreme flow rate, and the NPSH value of 0.27 Qd was 7.5% greater than that under design condition.
- 8 November 2021
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 9 (11) , 1240
Open AccessResearch on Visualization of Inducer Cavitation of High-Speed Centrifugal Pump in Low Flow Conditions
Inducer is often used to improve the cavitation performance of pump. In order to study the cavitation characteristics of inducer under low flow condition of high-speed pump, high-speed photography technology was employed in this paper to carry out visual experiments on the inducer of a high-speed centrifugal pump. In low flow rates, Cavitation distribution and evolution among the inducer were captured. The experimental results revealed that a band-shaped backflow vortex in the inlet pipe would occur when the flow rate was less than 0.3 Qd. Moreover, the backflow vortex in the inlet pipe rotated with the inducer and the rotational speed of backflow vortex was approximately half of the inducer. The visualization test of 0.27 Qd was carried out: when the NPSH was greater than 6.72 m, the bubbles in the inlet pipe were asymmetrical; When the NPSH dropped to 5.41 m, the cavitation was becoming less asymmetrical; When NPSH dropped to 3.81 m, cavitation evolved to the deteriorating stage, plenty of bubbles entered into the main impeller, resulting in a rapid decline of pump performance. Furthermore, the cavitation performance was worse at an extreme flow rate, and the NPSH value of 0.27 Qd was 7.5% greater than that under design condition.
- Open Access
- 15 August 2016
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 18 (5) , 3383-3396
Experimental and numerical investigation of interior flow-induced noise in pump as turbine
The flow-induced interior noise in pump as turbine (PAT) consists of flow-borne noise and flow-induced structure noise from dipole source. Without accurate distinguishing of main interior noise, the noise control and management cannot be guided. The experiments of flow-induced interior noise and free modals for rotor and casing were performed to validate the accuracy of numerical methods. The computational models for flow-induced noise and flow-borne noise considering structure in interior acoustic field were developed. On the basis of this, the spectrum characteristics of each noise source and their contribution to the total noise were distinguished. It is found that within interior noise, the radiated energy of flow-induced structure noise is less than that of flow-borne noise generated by dipole source. Compared with the experiment, the flow-borne noise considering structure due to casing source can more precisely reflect joint action of multiple sources. Especially in larger flow conditions, the maximum error is only 5.9 % at Blade-Passing Frequency (BPF) and its harmonics.
- 15 August 2016
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 18 (5) , 3383-3396
Open AccessExperimental and numerical investigation of interior flow-induced noise in pump as turbine
The flow-induced interior noise in pump as turbine (PAT) consists of flow-borne noise and flow-induced structure noise from dipole source. Without accurate distinguishing of main interior noise, the noise control and management cannot be guided. The experiments of flow-induced interior noise and free modals for rotor and casing were performed to validate the accuracy of numerical methods. The computational models for flow-induced noise and flow-borne noise considering structure in interior acoustic field were developed. On the basis of this, the spectrum characteristics of each noise source and their contribution to the total noise were distinguished. It is found that within interior noise, the radiated energy of flow-induced structure noise is less than that of flow-borne noise generated by dipole source. Compared with the experiment, the flow-borne noise considering structure due to casing source can more precisely reflect joint action of multiple sources. Especially in larger flow conditions, the maximum error is only 5.9 % at Blade-Passing Frequency (BPF) and its harmonics.
- Open Access
- 30 June 2016
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 18 (4) , 2667-2682
Noise reduction in centrifugal pump as turbine: influence of leaning blade or tongue
To reduce the interior/exterior flow-induced noise in centrifugal pump as turbine (PAT), based on the relation between in-phase hydrodynamic action and radiated noise, the angle formula in ideal condition by individually leaning blade was proposed. Considering the joint leaning effect, the formulas associated with parallel- and counter-leaning blade and tongue were presented. The corresponding active noise reduction approaches were put forward without losing hydraulic performance. For noise simulation, the numerical method for interior noise and finite element model for casing structure were checked, with good agreements achieved. The boundary element method (BEM) and finite element method (FEM) were used to investigate the interior/exterior noise characteristics of PATs by varying the shapes of blade or tongue. Researches show that the interior noise due to casing source can reflect joint action of multiple sources. It is feasible to predict the interior noise induced only by casing source through BEM. The leaned blade can keep PAT’s original performance, the leaned tongue can significantly improve the efficiency overall operating range with an increase from 0.67 % to 1.81 %, and the combined counter-leaning blade and tongue can increase the efficiency in larger flow rates. They can all reduce sound pressure level (SPL) at fundamental frequency and total sound energy, and the noise reduction effect under joint action is best.
- 30 June 2016
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 18 (4) , 2667-2682
Open AccessNoise reduction in centrifugal pump as turbine: influence of leaning blade or tongue
To reduce the interior/exterior flow-induced noise in centrifugal pump as turbine (PAT), based on the relation between in-phase hydrodynamic action and radiated noise, the angle formula in ideal condition by individually leaning blade was proposed. Considering the joint leaning effect, the formulas associated with parallel- and counter-leaning blade and tongue were presented. The corresponding active noise reduction approaches were put forward without losing hydraulic performance. For noise simulation, the numerical method for interior noise and finite element model for casing structure were checked, with good agreements achieved. The boundary element method (BEM) and finite element method (FEM) were used to investigate the interior/exterior noise characteristics of PATs by varying the shapes of blade or tongue. Researches show that the interior noise due to casing source can reflect joint action of multiple sources. It is feasible to predict the interior noise induced only by casing source through BEM. The leaned blade can keep PAT’s original performance, the leaned tongue can significantly improve the efficiency overall operating range with an increase from 0.67 % to 1.81 %, and the combined counter-leaning blade and tongue can increase the efficiency in larger flow rates. They can all reduce sound pressure level (SPL) at fundamental frequency and total sound energy, and the noise reduction effect under joint action is best.
- 17 March 2014
- Published by ASME International in Journal of Fluids Engineering
- Vol. 136 (5) , 054501
Effects of the Radial Gap Between Impeller Tips and Volute Tongue Influencing the Performance and Pressure Pulsations of Pump as Turbine
The radial gap between the impeller tips and volute tongue is an important factor influencing the overall performance and unsteady pressure fields of the pump as turbine (PAT). In this paper, a numerical investigation of the PAT's steady performance with different radial gaps was first performed. The results show that there is an optimal radial gap for a PAT to achieve its highest efficiency. An analysis of the PAT's unsteady pressure fields indicates that the rotorstator interaction of a rotating impeller and stationery volute would cause high frequency unsteady pulsation within the volute and low frequency unsteady pressure pulsation within the impeller. The high frequency unsteady pressure pulsation would propagate through the PAT's flow channel. Thus, the unsteady pressure field within the impeller is the combined effect of these two kinds of pressure pulsations. The unsteady pressure pulsation within the outlet pipe is mainly caused by the propagation of unsteady pressure formed within the volute. With the increase of the radial gap, the amplitude of high frequency unsteady pressure pulsation within the volute caused by the rotor-stator interaction is decreased, while the amplitude of the low frequency unsteady pressure pulsation caused by the rotor-stator interaction within the impeller remains unchanged.
- 17 March 2014
- Published by ASME International in Journal of Fluids Engineering
- Vol. 136 (5) , 054501
Effects of the Radial Gap Between Impeller Tips and Volute Tongue Influencing the Performance and Pressure Pulsations of Pump as Turbine
The radial gap between the impeller tips and volute tongue is an important factor influencing the overall performance and unsteady pressure fields of the pump as turbine (PAT). In this paper, a numerical investigation of the PAT's steady performance with different radial gaps was first performed. The results show that there is an optimal radial gap for a PAT to achieve its highest efficiency. An analysis of the PAT's unsteady pressure fields indicates that the rotorstator interaction of a rotating impeller and stationery volute would cause high frequency unsteady pulsation within the volute and low frequency unsteady pressure pulsation within the impeller. The high frequency unsteady pressure pulsation would propagate through the PAT's flow channel. Thus, the unsteady pressure field within the impeller is the combined effect of these two kinds of pressure pulsations. The unsteady pressure pulsation within the outlet pipe is mainly caused by the propagation of unsteady pressure formed within the volute. With the increase of the radial gap, the amplitude of high frequency unsteady pressure pulsation within the volute caused by the rotor-stator interaction is decreased, while the amplitude of the low frequency unsteady pressure pulsation caused by the rotor-stator interaction within the impeller remains unchanged.
- 20 November 2012
- Published by ASME International in Journal of Fluids Engineering
- Vol. 134 (12) , 124503
Influence of Blade Number on the Performance and Pressure Pulsations in a Pump Used as a Turbine
The rotor-stator interaction of a rotating impeller and a stationary volute could cause strong pressure pulsations and generate flow induced noise and vibration in a pump used as a turbine (PAT). Blade number is one of the main geometric parameters of the impeller. In this paper, a numerical investigation of the PAT’s unsteady pressure field with different blade numbers was performed. The accuracy of global performance prediction by computational fluid dynamics (CFD) was first verified through comparison between numerical and experimental results. Unsteady pressure fields of the PAT with different blade numbers were simulated, and the pulsations were extracted at various locations covering the PAT’s three main hydraulic parts. A detailed analysis of the unsteady pressure field distributions within the PAT’s control volume and comparison of unsteady pressure difference caused by the increase of blade number were performed. The transient flow results provided the unsteady pressure distribution within PAT and showed that increasing the blade number could effectively reduce the amplitude of pressure pulsations. Finally, unsteady pressure field tests were performed and some unsteady results obtained by unsteady field analysis were validated.
- 20 November 2012
- Published by ASME International in Journal of Fluids Engineering
- Vol. 134 (12) , 124503
Influence of Blade Number on the Performance and Pressure Pulsations in a Pump Used as a Turbine
The rotor-stator interaction of a rotating impeller and a stationary volute could cause strong pressure pulsations and generate flow induced noise and vibration in a pump used as a turbine (PAT). Blade number is one of the main geometric parameters of the impeller. In this paper, a numerical investigation of the PAT’s unsteady pressure field with different blade numbers was performed. The accuracy of global performance prediction by computational fluid dynamics (CFD) was first verified through comparison between numerical and experimental results. Unsteady pressure fields of the PAT with different blade numbers were simulated, and the pulsations were extracted at various locations covering the PAT’s three main hydraulic parts. A detailed analysis of the unsteady pressure field distributions within the PAT’s control volume and comparison of unsteady pressure difference caused by the increase of blade number were performed. The transient flow results provided the unsteady pressure distribution within PAT and showed that increasing the blade number could effectively reduce the amplitude of pressure pulsations. Finally, unsteady pressure field tests were performed and some unsteady results obtained by unsteady field analysis were validated.
- 29 May 2012
- Published by ASME International in Journal of Fluids Engineering
- Vol. 134 (6) , 061102
Effects of Blade Wrap Angle Influencing a Pump as Turbine
A pump is not ideally designed to operate as a turbine. To improve the efficiency of a pump as turbine (PAT), the redesign of the PAT, according to the flow of the turbine, is required. The blade wrap angle is one of the main geometric parameters in impeller design. Therefore, an investigation into the blade wrap angle to the PAT’s influence can be useful. In order to understand blade wrap angle to the influence of the PAT, this paper numerically investigated three different specific speeds of PATs with different blade wrap angles. The validity of numerical simulation was first confirmed through a comparison between numerical and experimental results. The performance change of the PATs with the blade wrap angle was acquired. A detailed hydraulic loss distribution and a theoretical analysis were performed to investigate the reasons for performance changes caused by the blade wrap angle. The results show that there is an optimal blade wrap angle for a PAT to achieve the highest efficiency and the optimal blade wrap angle decreases with an increasing specific speed. A performance analysis shows the PAT’s flow versus pressure head (Q-H) and flow versus generated shaft power (Q-P) curves are lowered with the decrease of the blade wrap angle. The hydraulic loss distribution and theoretical analysis illustrate that it is the decrease of hydraulic loss within the impeller, together with the decrease of the theoretical head, that results in the performance decrease. The decrease of hydraulic loss within the impeller is attributed to the shortened impeller blade passage and the reduced velocity gradient within the impeller flow channel. With the decrease of the blade wrap angle, the slip factor of the PAT’s impeller is decreased; therefore, its theoretical head is also decreased.
- 29 May 2012
- Published by ASME International in Journal of Fluids Engineering
- Vol. 134 (6) , 061102
Effects of Blade Wrap Angle Influencing a Pump as Turbine
A pump is not ideally designed to operate as a turbine. To improve the efficiency of a pump as turbine (PAT), the redesign of the PAT, according to the flow of the turbine, is required. The blade wrap angle is one of the main geometric parameters in impeller design. Therefore, an investigation into the blade wrap angle to the PAT’s influence can be useful. In order to understand blade wrap angle to the influence of the PAT, this paper numerically investigated three different specific speeds of PATs with different blade wrap angles. The validity of numerical simulation was first confirmed through a comparison between numerical and experimental results. The performance change of the PATs with the blade wrap angle was acquired. A detailed hydraulic loss distribution and a theoretical analysis were performed to investigate the reasons for performance changes caused by the blade wrap angle. The results show that there is an optimal blade wrap angle for a PAT to achieve the highest efficiency and the optimal blade wrap angle decreases with an increasing specific speed. A performance analysis shows the PAT’s flow versus pressure head (Q-H) and flow versus generated shaft power (Q-P) curves are lowered with the decrease of the blade wrap angle. The hydraulic loss distribution and theoretical analysis illustrate that it is the decrease of hydraulic loss within the impeller, together with the decrease of the theoretical head, that results in the performance decrease. The decrease of hydraulic loss within the impeller is attributed to the shortened impeller blade passage and the reduced velocity gradient within the impeller flow channel. With the decrease of the blade wrap angle, the slip factor of the PAT’s impeller is decreased; therefore, its theoretical head is also decreased.