Hyung-Il Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hyung-Il Kim has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Yong Hoon Kwon
Pusan National University
5 shared publications- Hyo-Joung Seol
Department of Dental Materials, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan-si 50612, Republic of Korea
3 shared publications - Mi-Gyoung Park
Professor and Chairman, Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea
2 shared publications Bock Hur
Department of Conservative Dentistry, College of Dentistry, Pusan National University, Pusan 602–739, Republic of Korea
1 shared publicationChang‐Min Jang
Department of Dental Materials, College of Dentistry and Medical Research Institute, Pusan National University, 1-10 Ami-dong Seo-gu, Pusan 602-739, Korea
1 shared publicationChin-Ho Yu
Pusan National University
1 shared publication
Latest Publications
- Open Access
- 1 March 2010
- Published by Springer Nature in Gold Bulletin
- Vol. 43 (1) , 42-48
Age-hardening by miscibility limit in a multi-purpose dental gold alloy containing platinum
- 1 March 2010
- Published by Springer Nature in Gold Bulletin
- Vol. 43 (1) , 42-48
Open AccessAge-hardening by miscibility limit in a multi-purpose dental gold alloy containing platinum
- 1 March 2008
- Published by Springer Nature in Journal of Materials Science
- Vol. 43 (5) , 1539-1545
Age-hardening behaviour of a spinodally decomposed low-carat gold alloy
- 1 March 2008
- Published by Springer Nature in Journal of Materials Science
- Vol. 43 (5) , 1539-1545
Age-hardening behaviour of a spinodally decomposed low-carat gold alloy
- 30 January 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 78 (2) , 253-258
Effect of irradiation mode on polymerization of dental composite resins
- 30 January 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 78 (2) , 253-258
Effect of irradiation mode on polymerization of dental composite resins
- 22 July 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 76B (1) , 106-113
Evaluation of polymerization of light‐curing hybrid composite resins
The quality of polymerization of hybrid composite resins was tested to explore their feasibility for dental restorations. For this, microhardness, polymerization shrinkage, the coefficient of thermal expansion, and surface morphology were evaluated during or after light curing in conjunction with the thermocycling process. Each product had different microhardness values. The repeated thermal stimulus has no specific effect on the change of microhardness. The difference of microhardness between the thermocycled specimens and specimens stored only in distilled water was minor. The measured microhardness had a linear correlation with the filler content (vol %) of the tested specimens. The polymerization shrinkage had rapidly increased only during the light curing, and then it reached a plateau. Among the specimens, Z250 showed the least amount of shrinkage for all tested thicknesses. Regardless of the product, the shrinkage values increased as the specimens became thick. The coefficient of thermal expansion of the control specimens ranged between 42 and 55 μm/°C in the temperature range of 30–80°C. The coefficient showed an inverse correlation with the filler content. Through the thermocycling process, Palfique Estelite showed randomly propagating cracks on the surface. Larger fillers showed a more apparent detachment than the smaller fillers. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
- 22 July 2005
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 76B (1) , 106-113
Evaluation of polymerization of light‐curing hybrid composite resins
The quality of polymerization of hybrid composite resins was tested to explore their feasibility for dental restorations. For this, microhardness, polymerization shrinkage, the coefficient of thermal expansion, and surface morphology were evaluated during or after light curing in conjunction with the thermocycling process. Each product had different microhardness values. The repeated thermal stimulus has no specific effect on the change of microhardness. The difference of microhardness between the thermocycled specimens and specimens stored only in distilled water was minor. The measured microhardness had a linear correlation with the filler content (vol %) of the tested specimens. The polymerization shrinkage had rapidly increased only during the light curing, and then it reached a plateau. Among the specimens, Z250 showed the least amount of shrinkage for all tested thicknesses. Regardless of the product, the shrinkage values increased as the specimens became thick. The coefficient of thermal expansion of the control specimens ranged between 42 and 55 μm/°C in the temperature range of 30–80°C. The coefficient showed an inverse correlation with the filler content. Through the thermocycling process, Palfique Estelite showed randomly propagating cracks on the surface. Larger fillers showed a more apparent detachment than the smaller fillers. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
- Open Access
- 24 August 2004
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 72B (1) , 102-108
Evaluation of the effect of fluoride‐containing acetic acid on NiTi wires
The possibility of the formation of hydrofluoric acid by the reaction of fluoride with acetic acid seems natural in the oral cavity. The effect of an acidic fluoride solution on NiTi wires was investigated by testing microhardness and color changes on wires. For aesthetic reasons, the color change on wires was also evaluated. Wires were immersed in four different test solutions for 1 or 3 days. As‐received wires were used as a reference. After immersion for 3 days, the microhardness of the tested wires increased 1.8% to 10.4% compared to that of their as‐received state. Wires immersed in a higher NaF concentration, lower pH solution with longer immersion yielded a more corroded surface than those of the counter cases. Wires showed a different color after immersion. However, after 3 days in solutions of pH 4, wires showed an appreciable color change regardless of the products. In test solutions, 3M wires showed the highest volumetric and percentage (0.59 for 0.05%; 1.19 for 0.2% solution) weight loss and G&H wires showed the least volumetric and percentage (0.43 for 0.05%; 1.05 for 0.2% solution) weight loss among tested wires. In pH 6 solutions, wires lost weight and were under the detection limit of the testing machine. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 72B: 102–108, 2005
- 24 August 2004
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 72B (1) , 102-108
Open AccessEvaluation of the effect of fluoride‐containing acetic acid on NiTi wires
The possibility of the formation of hydrofluoric acid by the reaction of fluoride with acetic acid seems natural in the oral cavity. The effect of an acidic fluoride solution on NiTi wires was investigated by testing microhardness and color changes on wires. For aesthetic reasons, the color change on wires was also evaluated. Wires were immersed in four different test solutions for 1 or 3 days. As‐received wires were used as a reference. After immersion for 3 days, the microhardness of the tested wires increased 1.8% to 10.4% compared to that of their as‐received state. Wires immersed in a higher NaF concentration, lower pH solution with longer immersion yielded a more corroded surface than those of the counter cases. Wires showed a different color after immersion. However, after 3 days in solutions of pH 4, wires showed an appreciable color change regardless of the products. In test solutions, 3M wires showed the highest volumetric and percentage (0.59 for 0.05%; 1.19 for 0.2% solution) weight loss and G&H wires showed the least volumetric and percentage (0.43 for 0.05%; 1.05 for 0.2% solution) weight loss among tested wires. In pH 6 solutions, wires lost weight and were under the detection limit of the testing machine. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 72B: 102–108, 2005