Quoc Nam Trinh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Quoc Nam Trinh has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Fook Hoong Choo
Energy Research Institute @ NTU, Nanyang Technological University, Singapore, Singapore
3 shared publicationsPeng Wang
School of Electrical and Electronics Engineering, Nanyang Technological University, Singapore, Singapore
3 shared publications- Yi Tang
Nanyang Technological University
3 shared publications - Fook Hoong Choo
Energy Research Institute, Nanyang Technological University, Singapore Singapore
2 shared publications - Peng Wang
Nanjing Normal University
2 shared publications - Bang L. H. Nguyen
ECE Department Clarkson University Potsdam NY USA
1 shared publication
Latest Publications
- Open Access
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 200957-200971
Design and Control of Advanced Uninterruptible Power Supplies With SiC MOSFETs for Enhanced Performance and Efficiency
This paper proposes a high-performance high-efficiency single-phase uninterruptible power supply (UPS), which uses totem pole power factor correction in AC/DC stage and three-level T-type inverter in DC/AC stage. Design process with detailed steps to select the UPS components and controller algorithms is presented. To guarantee sinusoidal output voltage with ultra-low total harmonic distortion (THD) at the AC output of UPS under various load conditions, an enhanced voltage controller is implemented with a proportional and multiple resonant controllers. Meanwhile, the totem pole PFC offers very high efficiency and ensures unity power factor operation of UPS system with advanced two-poles-two-zeros (2p2z) compensator. Thanks to the highly efficient AC/DC and DC/AC stages, the UPS system achieves an overall efficiency higher than 97.8%. In addition, to ensure stable operation of the UPS when there is a complete loss of AC input voltage, a novel detection method for AC voltage loss is developed in PFC control scheme to transit the grid supply mode to battery mode. Therefore, the load voltage remains stable despite the loss of AC input voltage. Simulation and experimental tests of 3.6 kVA UPS system verify the effectiveness of the proposed control scheme.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 200957-200971
Open AccessDesign and Control of Advanced Uninterruptible Power Supplies With SiC MOSFETs for Enhanced Performance and Efficiency
This paper proposes a high-performance high-efficiency single-phase uninterruptible power supply (UPS), which uses totem pole power factor correction in AC/DC stage and three-level T-type inverter in DC/AC stage. Design process with detailed steps to select the UPS components and controller algorithms is presented. To guarantee sinusoidal output voltage with ultra-low total harmonic distortion (THD) at the AC output of UPS under various load conditions, an enhanced voltage controller is implemented with a proportional and multiple resonant controllers. Meanwhile, the totem pole PFC offers very high efficiency and ensures unity power factor operation of UPS system with advanced two-poles-two-zeros (2p2z) compensator. Thanks to the highly efficient AC/DC and DC/AC stages, the UPS system achieves an overall efficiency higher than 97.8%. In addition, to ensure stable operation of the UPS when there is a complete loss of AC input voltage, a novel detection method for AC voltage loss is developed in PFC control scheme to transit the grid supply mode to battery mode. Therefore, the load voltage remains stable despite the loss of AC input voltage. Simulation and experimental tests of 3.6 kVA UPS system verify the effectiveness of the proposed control scheme.
- Open Access
Advanced Control Strategy to Compensate Power Sharing Error and DC Circulating Current in Parallel Single-Phase Inverters
This paper proposes an advanced control strategy to eliminate both current sharing error and DC circulating current caused by line impedance mismatched and measurement errors in islanded AC microgrid system. The proposed adaptive virtual impedance scheme is developed with the aid of a low bandwidth communication and a simple PI compensator to adaptively adjust the virtual impedance value so that active and reactive power will be shared equally among inverters. Meanwhile, the DC offset in output voltage measurement is detected by using the voltage ripple information of DC link voltage of inverter. The proposed control strategy can be implemented directly without any pre-knowledge of the feeder impedances. The proposed compensation scheme is simple and easy to implement, and it also does not require extra hardware circuit or sensors. The effectiveness of the proposed solution is verified by simulation and experimental results of 6 kVA microgrid system.
Open AccessAdvanced Control Strategy to Compensate Power Sharing Error and DC Circulating Current in Parallel Single-Phase Inverters
This paper proposes an advanced control strategy to eliminate both current sharing error and DC circulating current caused by line impedance mismatched and measurement errors in islanded AC microgrid system. The proposed adaptive virtual impedance scheme is developed with the aid of a low bandwidth communication and a simple PI compensator to adaptively adjust the virtual impedance value so that active and reactive power will be shared equally among inverters. Meanwhile, the DC offset in output voltage measurement is detected by using the voltage ripple information of DC link voltage of inverter. The proposed control strategy can be implemented directly without any pre-knowledge of the feeder impedances. The proposed compensation scheme is simple and easy to implement, and it also does not require extra hardware circuit or sensors. The effectiveness of the proposed solution is verified by simulation and experimental results of 6 kVA microgrid system.
- 18 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (3) , 2879-2889
Control Strategy to Compensate for Current and Voltage Measurement Errors in Three-Phase PWM Rectifiers
This study introduces a compensation strategy to deal with both current and voltage measurement errors in the threephase PWM rectifier system. The DC offset and scaling errors in the voltage and current measurements cause the injection of undesired DC and unbalanced currents into the three-phase input current and subsequently lead to voltage ripple at the DC output voltage. This paper proposes a compensation scheme for current measurement error where the DC offset and scaling errors in the current measurement are estimated from the characteristic of the DC output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, an advanced current controller designed with a proportional integral plus two resonant controllers tuned at the fundamental grid frequency (ω $_s$ ) and 2ω $_s$ in the synchronous (d-q) reference frame is suggested to reject the impact of the DC offset and scaling errors in the voltage measurement. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost-effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.- 18 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (3) , 2879-2889
Control Strategy to Compensate for Current and Voltage Measurement Errors in Three-Phase PWM Rectifiers
This study introduces a compensation strategy to deal with both current and voltage measurement errors in the threephase PWM rectifier system. The DC offset and scaling errors in the voltage and current measurements cause the injection of undesired DC and unbalanced currents into the three-phase input current and subsequently lead to voltage ripple at the DC output voltage. This paper proposes a compensation scheme for current measurement error where the DC offset and scaling errors in the current measurement are estimated from the characteristic of the DC output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, an advanced current controller designed with a proportional integral plus two resonant controllers tuned at the fundamental grid frequency (ω $_s$ ) and 2ω $_s$ in the synchronous (d-q) reference frame is suggested to reject the impact of the DC offset and scaling errors in the voltage measurement. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost-effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 801-813
Mitigation of DC and Harmonic Currents Generated by Voltage Measurement Errors and Grid Voltage Distortions in Transformerless Grid-Connected Inverters
The DC offset and scaling errors in the voltage measurements cause the injection of undesired DC and harmonic currents into the three-phase output currents of the grid-connected inverter. This study proposes an enhanced current control scheme to eliminate the DC and harmonic currents caused by voltage distortion and voltage measurement error in three-phase grid-connected inverters. The proposed current controller is designed in the synchronous (d-q) reference frame and composed of a proportional resonant (PR) controller and a repetitive controller (RC). The role of the RC is to regulate the grid current follow the reference value as well as compensate all $6{\mathrm n}\omega_{\mathrm{s}}$ and $(6{\mathrm n}\pm2)_\omega_s$ (${\mathrm n} = 1, 2, 3\ldots$) harmonic components caused by distorted grid voltage and scaling errors. Meanwhile, the PR controller helps to compensate the DC current generated by DC offset measurement errors to guarantee the three-phase grid currents are balanced and sinusoidal with extremely low DC component. Since the RC employed in the proposed current controller reduces to time delay by four times compared to the conventional RC, the proposed control system ensures good steady-state performance of the grid current without deteriorating its fast dynamic response. The effectiveness of the suggested solution is verified by various experimental tests.- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 801-813
Mitigation of DC and Harmonic Currents Generated by Voltage Measurement Errors and Grid Voltage Distortions in Transformerless Grid-Connected Inverters
The DC offset and scaling errors in the voltage measurements cause the injection of undesired DC and harmonic currents into the three-phase output currents of the grid-connected inverter. This study proposes an enhanced current control scheme to eliminate the DC and harmonic currents caused by voltage distortion and voltage measurement error in three-phase grid-connected inverters. The proposed current controller is designed in the synchronous (d-q) reference frame and composed of a proportional resonant (PR) controller and a repetitive controller (RC). The role of the RC is to regulate the grid current follow the reference value as well as compensate all $6{\mathrm n}\omega_{\mathrm{s}}$ and $(6{\mathrm n}\pm2)_\omega_s$ (${\mathrm n} = 1, 2, 3\ldots$) harmonic components caused by distorted grid voltage and scaling errors. Meanwhile, the PR controller helps to compensate the DC current generated by DC offset measurement errors to guarantee the three-phase grid currents are balanced and sinusoidal with extremely low DC component. Since the RC employed in the proposed current controller reduces to time delay by four times compared to the conventional RC, the proposed control system ensures good steady-state performance of the grid current without deteriorating its fast dynamic response. The effectiveness of the suggested solution is verified by various experimental tests.- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (6) , 5401-5414
Compensation of DC Offset and Scaling Errors in Voltage and Current Measurements of Three-Phase AC/DC Converters
The dc offset and scaling errors in the voltage and current measurements cause the injection of undesired dc and unbalanced currents into the three-phase input currents and subsequently lead to voltage ripple at the dc output voltage of the ac/dc converter. This paper proposes a compensation scheme for current measurement error where the dc offset and scaling errors in the current measurement are estimated from the voltage ripple characteristics of the dc output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, the dc offset and scaling errors in the voltage measurement can be rejected by using an advanced current controller developed with a proportional resonant plus a repetitive controller designed in the synchronous (d-q) reference frame. The proposed control algorithm is able to effectively reject the impact of both voltage and current measurement error so that the three-phase input currents are regulated to be balanced and sinusoidal with ultralow dc current component. Meanwhile, the dc output voltage is also well regulated to be pure dc with a negligibly small voltage ripple. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (6) , 5401-5414
Compensation of DC Offset and Scaling Errors in Voltage and Current Measurements of Three-Phase AC/DC Converters
The dc offset and scaling errors in the voltage and current measurements cause the injection of undesired dc and unbalanced currents into the three-phase input currents and subsequently lead to voltage ripple at the dc output voltage of the ac/dc converter. This paper proposes a compensation scheme for current measurement error where the dc offset and scaling errors in the current measurement are estimated from the voltage ripple characteristics of the dc output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, the dc offset and scaling errors in the voltage measurement can be rejected by using an advanced current controller developed with a proportional resonant plus a repetitive controller designed in the synchronous (d-q) reference frame. The proposed control algorithm is able to effectively reject the impact of both voltage and current measurement error so that the three-phase input currents are regulated to be balanced and sinusoidal with ultralow dc current component. Meanwhile, the dc output voltage is also well regulated to be pure dc with a negligibly small voltage ripple. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.
- 14 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (9) , 7508-7519
Control Strategy to Eliminate Impact of Voltage Measurement Errors on Grid Current Performance of Three-Phase Grid-Connected Inverters
This study proposes an advanced current control strategy for three-phase grid-connected inverters to reject the impact of the dc offsets and scaling errors in the grid voltage measurement on the grid current performance. The proposed current controller designed in the synchronous (d-q) reference frame is developed with a proportional integral (PI) plus three vector PI controllers. The PI controller regulates the fundamental current to follow its reference, meanwhile, three vector PI controllers tuned at the fundamental grid frequency (ω 8 ), 2ω 8 , 6ω 8 are employed to eliminate the dc, unbalance, harmonic components in the grid current. As a result, the three-phase grid currents are controlled to be balanced, sinusoidal, and extremely low dc component despite the presence of the dc offset and scaling errors in the grid voltage measurement and distorted grid voltage conditions. The main advantage of the proposed control scheme is that it is developed without the need of additional hardware circuit, dc extraction, and harmonic detection scheme so that it can be integrated into the existing grid-connected inverter system without extra cost. The effectiveness of the suggested solution is verified by experimental results under various grid voltage conditions and the grid voltage measurement errors.
- 14 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (9) , 7508-7519
Control Strategy to Eliminate Impact of Voltage Measurement Errors on Grid Current Performance of Three-Phase Grid-Connected Inverters
This study proposes an advanced current control strategy for three-phase grid-connected inverters to reject the impact of the dc offsets and scaling errors in the grid voltage measurement on the grid current performance. The proposed current controller designed in the synchronous (d-q) reference frame is developed with a proportional integral (PI) plus three vector PI controllers. The PI controller regulates the fundamental current to follow its reference, meanwhile, three vector PI controllers tuned at the fundamental grid frequency (ω 8 ), 2ω 8 , 6ω 8 are employed to eliminate the dc, unbalance, harmonic components in the grid current. As a result, the three-phase grid currents are controlled to be balanced, sinusoidal, and extremely low dc component despite the presence of the dc offset and scaling errors in the grid voltage measurement and distorted grid voltage conditions. The main advantage of the proposed control scheme is that it is developed without the need of additional hardware circuit, dc extraction, and harmonic detection scheme so that it can be integrated into the existing grid-connected inverter system without extra cost. The effectiveness of the suggested solution is verified by experimental results under various grid voltage conditions and the grid voltage measurement errors.
- 16 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 5 (3) , 1164-1176
An Improved Control Strategy of Three-Phase PWM Rectifiers Under Input Voltage Distortions and DC-Offset Measurement Errors
This paper proposes an enhanced current control strategy to reject the impact of dc-offset measurement error and the distortion in the supply voltage on the dc output voltage and the input current performance of three-phase pulsewidth modulation rectifiers. The proposed current controller designed in the synchronous reference frame is developed with a proportional integral (PI) and two vector PI (VPI) controllers. The PI controller regulates the fundamental current to follow its reference generated from outer dc-link voltage control, meanwhile two VPI controllers tuned at the fundamental grid frequency (ω s ) and 6ω s are employed to eliminate the dc and harmonic components in the input current. Compared with the standard resonant controllers, the proposed VPI controller offers some advantages such as simpler and straightforward tuning process for controller gains and more robust control system against control delay time and frequency variations. Thanks to the effectiveness of the VPI controllers, the dc output voltage is controlled at a stable manner without any ac ripple, and the three-phase input currents are controlled to be balanced, sinusoidal, and extremely low dc component despite the presence of the dc-offset measurement error and distorted supply voltage conditions. Various experimental tests are provided to verify the effectiveness of the proposed control algorithm.
- 16 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 5 (3) , 1164-1176
An Improved Control Strategy of Three-Phase PWM Rectifiers Under Input Voltage Distortions and DC-Offset Measurement Errors
This paper proposes an enhanced current control strategy to reject the impact of dc-offset measurement error and the distortion in the supply voltage on the dc output voltage and the input current performance of three-phase pulsewidth modulation rectifiers. The proposed current controller designed in the synchronous reference frame is developed with a proportional integral (PI) and two vector PI (VPI) controllers. The PI controller regulates the fundamental current to follow its reference generated from outer dc-link voltage control, meanwhile two VPI controllers tuned at the fundamental grid frequency (ω s ) and 6ω s are employed to eliminate the dc and harmonic components in the input current. Compared with the standard resonant controllers, the proposed VPI controller offers some advantages such as simpler and straightforward tuning process for controller gains and more robust control system against control delay time and frequency variations. Thanks to the effectiveness of the VPI controllers, the dc output voltage is controlled at a stable manner without any ac ripple, and the three-phase input currents are controlled to be balanced, sinusoidal, and extremely low dc component despite the presence of the dc-offset measurement error and distorted supply voltage conditions. Various experimental tests are provided to verify the effectiveness of the proposed control algorithm.
- 1 May 2015
- Published by The Korean Institute of Electrical Engineers in Journal of Electrical Engineering & Technology
- Vol. 10 (3) , 1015-1024
Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters
Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters Unified power quality conditioner;Four-switch inverter;Low cost;Harmonic compensation; This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.
- 1 May 2015
- Published by The Korean Institute of Electrical Engineers in Journal of Electrical Engineering & Technology
- Vol. 10 (3) , 1015-1024
Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters
Low Cost and High Performance UPQC with Four-Switch Three-Phase Inverters Unified power quality conditioner;Four-switch inverter;Low cost;Harmonic compensation; This paper introduces a low cost, high efficiency, high performance three-phase unified power quality conditioner (UPQC) by using four-switch three-phase inverters (FSTPIs) and an extra capacitor in the shunt active power filter (APF) side of the UPQC. In the proposed UPQC, both shunt and series APFs are developed by using FSTPIs so that the number of switching devices is reduced from twelve to eight devices. In addition, by inserting an additional capacitor in series with the shunt APF, the DC-link voltage in the proposed UPQC can also be greatly reduced. As a result, the system cost and power loss of the proposed UPQC is significantly minimized thanks to the use of a smaller number of power switches with a lower rating voltage without degrading the compensation performance of the UPQC. Design of passive components for the proposed UPQC to achieve a good performance is presented in detail. In addition, comparisons on power loss, overall system efficiency, compensation performance between the proposed UPQC and the traditional one are also determined in this paper. Simulation and experimental studies are performed to verify the validity of the proposed topology.