Fook Hoong Choo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fook Hoong Choo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Peng Wang
Nanjing Normal University
2 shared publications - Quoc Nam Trinh
Energy Research Institute @ NTU, Nanyang Technological University, Singapore
2 shared publications - Yi Tang
Nanyang Technological University
2 shared publications - Chee Keong Chan
Nanyang Technological University
1 shared publication - Fock‐Lai Tan
School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
1 shared publication - Hock Beng Lim
Nanyang Technological University
1 shared publication
Latest Publications
- 18 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (3) , 2879-2889
Control Strategy to Compensate for Current and Voltage Measurement Errors in Three-Phase PWM Rectifiers
This study introduces a compensation strategy to deal with both current and voltage measurement errors in the threephase PWM rectifier system. The DC offset and scaling errors in the voltage and current measurements cause the injection of undesired DC and unbalanced currents into the three-phase input current and subsequently lead to voltage ripple at the DC output voltage. This paper proposes a compensation scheme for current measurement error where the DC offset and scaling errors in the current measurement are estimated from the characteristic of the DC output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, an advanced current controller designed with a proportional integral plus two resonant controllers tuned at the fundamental grid frequency (ω $_s$ ) and 2ω $_s$ in the synchronous (d-q) reference frame is suggested to reject the impact of the DC offset and scaling errors in the voltage measurement. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost-effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.- 18 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 55 (3) , 2879-2889
Control Strategy to Compensate for Current and Voltage Measurement Errors in Three-Phase PWM Rectifiers
This study introduces a compensation strategy to deal with both current and voltage measurement errors in the threephase PWM rectifier system. The DC offset and scaling errors in the voltage and current measurements cause the injection of undesired DC and unbalanced currents into the three-phase input current and subsequently lead to voltage ripple at the DC output voltage. This paper proposes a compensation scheme for current measurement error where the DC offset and scaling errors in the current measurement are estimated from the characteristic of the DC output voltage ripple combining with simple band-pass and low-pass filters. Meanwhile, an advanced current controller designed with a proportional integral plus two resonant controllers tuned at the fundamental grid frequency (ω $_s$ ) and 2ω $_s$ in the synchronous (d-q) reference frame is suggested to reject the impact of the DC offset and scaling errors in the voltage measurement. The proposed compensation method is developed without the need of extra hardware circuit, sensor, or precise information of system parameters so that it can be considered as more cost-effective and robust solution. The effectiveness of the proposed solution is verified by experimental results.- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 801-813
Mitigation of DC and Harmonic Currents Generated by Voltage Measurement Errors and Grid Voltage Distortions in Transformerless Grid-Connected Inverters
The DC offset and scaling errors in the voltage measurements cause the injection of undesired DC and harmonic currents into the three-phase output currents of the grid-connected inverter. This study proposes an enhanced current control scheme to eliminate the DC and harmonic currents caused by voltage distortion and voltage measurement error in three-phase grid-connected inverters. The proposed current controller is designed in the synchronous (d-q) reference frame and composed of a proportional resonant (PR) controller and a repetitive controller (RC). The role of the RC is to regulate the grid current follow the reference value as well as compensate all $6{\mathrm n}\omega_{\mathrm{s}}$ and $(6{\mathrm n}\pm2)_\omega_s$ (${\mathrm n} = 1, 2, 3\ldots$) harmonic components caused by distorted grid voltage and scaling errors. Meanwhile, the PR controller helps to compensate the DC current generated by DC offset measurement errors to guarantee the three-phase grid currents are balanced and sinusoidal with extremely low DC component. Since the RC employed in the proposed current controller reduces to time delay by four times compared to the conventional RC, the proposed control system ensures good steady-state performance of the grid current without deteriorating its fast dynamic response. The effectiveness of the suggested solution is verified by various experimental tests.- 16 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 801-813
Mitigation of DC and Harmonic Currents Generated by Voltage Measurement Errors and Grid Voltage Distortions in Transformerless Grid-Connected Inverters
The DC offset and scaling errors in the voltage measurements cause the injection of undesired DC and harmonic currents into the three-phase output currents of the grid-connected inverter. This study proposes an enhanced current control scheme to eliminate the DC and harmonic currents caused by voltage distortion and voltage measurement error in three-phase grid-connected inverters. The proposed current controller is designed in the synchronous (d-q) reference frame and composed of a proportional resonant (PR) controller and a repetitive controller (RC). The role of the RC is to regulate the grid current follow the reference value as well as compensate all $6{\mathrm n}\omega_{\mathrm{s}}$ and $(6{\mathrm n}\pm2)_\omega_s$ (${\mathrm n} = 1, 2, 3\ldots$) harmonic components caused by distorted grid voltage and scaling errors. Meanwhile, the PR controller helps to compensate the DC current generated by DC offset measurement errors to guarantee the three-phase grid currents are balanced and sinusoidal with extremely low DC component. Since the RC employed in the proposed current controller reduces to time delay by four times compared to the conventional RC, the proposed control system ensures good steady-state performance of the grid current without deteriorating its fast dynamic response. The effectiveness of the suggested solution is verified by various experimental tests.- 1 December 2012
- Published by IWA Publishing in Water Practice & Technology
- Vol. 7 (4)
Portable solar desalination system using membrane distillation
This paper presents the development of a portable solar desalination system using membrane distillation (MD) for processing seawater for drinking in remote areas and for emergency situations such as natural disasters. The portable system uses the vacuum MD to desalinate the seawater. Solar energy is being harvested to provide the energy input for the MD. The portable system should be scalable so that numerous systems can be deployed in case of emergency. The system is self-contained and draws all its energy needs from solar energy. A combination of solar PV and solar thermal collectors are being exploited to harness the energy from the sun to power the portable system. The development work focuses on the engineering design of the MD system to optimize the water production within a given frame size for portability and energy availability. The challenge lies in the engineering of an efficient self-contained system that is reliable and ease of maintenance that will provide drinking water for all where clean drinking water is not readily available.
- 1 December 2012
- Published by IWA Publishing in Water Practice & Technology
- Vol. 7 (4)
Portable solar desalination system using membrane distillation
This paper presents the development of a portable solar desalination system using membrane distillation (MD) for processing seawater for drinking in remote areas and for emergency situations such as natural disasters. The portable system uses the vacuum MD to desalinate the seawater. Solar energy is being harvested to provide the energy input for the MD. The portable system should be scalable so that numerous systems can be deployed in case of emergency. The system is self-contained and draws all its energy needs from solar energy. A combination of solar PV and solar thermal collectors are being exploited to harness the energy from the sun to power the portable system. The development work focuses on the engineering design of the MD system to optimize the water production within a given frame size for portability and energy availability. The challenge lies in the engineering of an efficient self-contained system that is reliable and ease of maintenance that will provide drinking water for all where clean drinking water is not readily available.
- 13 April 2011
- Published by Springer Nature
- p. 209-231
An e-Science Cyberinfrastructure for Solar-Enabled Water Production and Recycling
- 13 April 2011
- Published by Springer Nature
- p. 209-231
An e-Science Cyberinfrastructure for Solar-Enabled Water Production and Recycling