ASAlessandra P. Smolek

Alessandra P. Smolek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alessandra P. Smolek has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Hydrologic and Water-Quality Evaluation of a Rapid-Flow Biofiltration Device

    by Alessandra P. Smolek, Andrew R. Anderson, William F. Hunt

    Manufactured treatment devices (MTDs) are increasingly installed to treat pollutants from stormwater in urban areas, but few peer-reviewed studies have assessed their field-scale performance. The Filterra biofiltration unit is a box filter combining high-flow engineered media with potential for biological treatment from a planted tree. A Filterra device was monitored for its impact on hydrology and water quality of runoff from a 0.10-ha impervious watershed in Fayetteville, North Carolina, for 22 months. Undersizing of the system and clogging of the media bed likely caused 22% of runoff to bypass the system. Although peak flows were significantly reduced (p<0.0001 ) by a median 57% (likely owing to parking lot detention), postdevelopment peak flows were not consistently reduced to predevelopment flows. The Filterra provided stormwater treatment by significantly reducing event mean concentrations (EMCs) and total pollutant loadings for sediment (total suspended solids and suspended sediment concentration), nutrients (total phosphorus, total nitrogen, total ammoniacal nitrogen, and total Kjeldahl nitrogen), and zinc. Median EMC removal efficiency ranged from 35 to 97% and median loading efficiency was 39–80% for these pollutants. The device did not reduce nitrate/nitrite, total dissolved phosphorus, or copper. Nutrient concentrations of stormwater discharged from the Filterra generally met “good” water-quality thresholds established for the state of North Carolina and EMC targets established by the state of Washington for emergent MTDs. Clogging susceptibility and frequent maintenance of the Filterra unit were notable. Overall, results suggest the Filterra is an effective MTD for treating stormwater from small impervious watersheds.


  • Evaluation of factors affecting soil carbon sequestration services of stormwater wet retention ponds in varying climate zones

    by L.S. Merriman, T.L.C. Moore, J.W. Wang, D.L. Osmond, A.M. Al-Rubaei, A.P. Smolek, G.T. Blecken, M. Viklander, W.F. Hunt


  • Stormwater Treatment Performance of a Permeable Pavement-Biofiltration System and a Stand-Alone Biofiltration Unit in North Carolina

    by A. R. Anderson, A. P. Smolek, W. F. Hunt

    A BioPave treatment train was retrofitted in an existing parking lot in Fayetteville, North Carolina, USA. The BioPave treatment train comprises a permeable pavement and Filterra devices in series. Additionally, a stand-alone Filterra biofiltration device was installed at the same site to evaluate its performance in treating pollutants of concern in North Carolina and elsewhere. The purpose of this study is to gain insight into the water quality treatment capabilities of a PICP—flow-through filter treatment train and to evaluate the stand-alone device's hydrologic and water quality performance. Automated, flow-proportional water quality samplers were installed to collect samples at multiple locations at each SCM. It was seen that the Filterra stand-alone device had sediment concentration reductions above 95% for both TSS and SSC. For nutrients, the Filterra reduced the percent total phosphorus and total nitrogen concentrations by a median of 62 and 33%, respectively. Overall the system treated the 1-in. design storm before significant overflow occurred and showed a similar watershed characteristics to predeveloped conditions. The BioPave system removed sediment, nitrogen, and phosphorus well despite having some moderate to severe clogging issues throughout the study, resulting in load reductions of 69, 84, and 72% by mass for nitrogen, phosphorus, and sediment, primarily through the mechanism of infiltration into the sandy loam underlying soils beneath the pavers.


  • Modeling Hydrologic Performance of Permeable Pavement with DRAINMOD in North Carolina and Ohio

    by A. P. Smolek, W. F. Hunt, R. J. Winston

    Variations in the hydrologic performance of permeable pavement can be due to several factors including gravel storage depth, drainage configuration, surface infiltration rate, and underlying soil type. A long-term hydrologic model is needed to better understand the influence of these factors on surface runoff, drainage, and exfiltration from permeable pavement systems. DRAINMOD is a widely accepted agricultural drainage model that can predict water table level, drainage, infiltration, and evapotranspiration continuously over long records of time. Past research has shown that DRAINMOD can be calibrated to accurately predict the hydrology of bioretention areas. Given that water movement through a permeable pavement cell is similar to a bioretention area, it is hypothesized that the model could also be calibrated to predict the hydrologic response from permeable pavement. Both stormwater control measures (SCMs) employ infiltration as the primary mechanism for peak flow attenuation and exfiltration for volume reduction. Drainage configurations for both SCMs are also analogous to the required DRAINMOD inputs. This study investigates the application of DRAINMOD to predict permeable pavement hydrology for a variety of different drainage configurations and underlying soil types. Three sites in North Carolina and one site in Ohio were monitored for rainfall, drainage outflow, and internal water level for a period of 9 to 12 months. The four sites have varying drainage configurations and underlying soils to represent a wide variety of permeable pavement applications. The model was calibrated for a period of 4 to 6 months at each site and validated for an additional 4 to 6 months. Results comparing the field-monitored and modeled volumes of drainage, surface runoff, and exfiltration/ET will be presented for each site. Preliminary results at the Boone, NC, site indicate success in predicting drainage volumes, with Nash-Sutcliffe efficiencies of 0.97 during the calibration period and 0.85 during the validation period. How the DRAINMOD outputs can be extended to predict the annual average water balance for varying drainage configurations and underlying soil types will also be discussed.


  • Water Quality and Hydrologic Performance of a Permeable Pavement-Modular Bioretention Treatment Train and a Stormwater Filter Box in Fayetteville, North Carolina

    by A. R. Anderson, W. F. Hunt, A. P. Smolek

    Impervious land cover in urban developments is commonly responsible for degraded water quality and potentially erosive flow rates on downstream water bodies. Many environmental products have recently been developed to satisfy the niche in the market for easy-to-retrofit stormwater practices; however, data on the field performance of these novel stormwater control measures to reduce runoff and improve water quality are limited. Given tight site constraints, retrofitting traditional pavement with pervious pavement provides numerous water quality and hydrologic benefits. This, coupled with other treatment devices as part of a "treatment train," is becoming a valuable option to reduce a site's stormwater footprint. A permeable interlocking concrete paver (PICP) system that drains to a 1.2 m by 1.2 m Filterra® bioretention retrofit was installed at an AmtrakTM parking lot in Fayetteville, North Carolina. With a catchment-to-footprint ratio of 2.5:1, the system is designed to mitigate the 10-year storm and filter any runoff that does not infiltrate into the sandy-loam subsoil of the PICP. Additionally, a standalone, conventional Filterra® modular bioretention cell was installed on the property to mitigate impervious runoff through a curb throat. Water quality, flow, and ponding level will be monitored at five locations, including (1) impervious asphalt before the PICP, (2) underdrain leaving the PICP and entering the Filterra, (3) underdrain leaving the Filterra, (4) impervious asphalt before the conventional Filterra, and (5) the underdrain pipe leaving the conventional Filterra. Using flow-paced automatic sampling, the above locations will be monitored for total phosphorus, ortho phosphorus, total soluble phosphorus, nitrate and nitrite, Total Kjeldahl Nitrogen, total ammoniated nitrogen, total nitrogen, particle size distribution, total suspended solids, suspended sediment concentration, specific gravity, copper (Cu), zinc (Zn), and total petroleum hydrocarbons. The goal of this study is to assess the pollutant-removal performance and hydrologic mitigation ability of both proprietary treatment devices and to use these data to model PICP dynamics.