Rocío Ortega
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rocío Ortega has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Miguel Gómez-Polo
Department of Conservative Dentistry and Prosthodontics School of Dentistry Complutense University of Madrid Madrid Spain
7 shared publications - Cristina Gómez-Polo
Department of Surgery, Faculty of Medicine, University of Salamanca, 37007 Salamanca, Spain
5 shared publications - Rubén Agustín-Panadero
Department of Stomatology, Faculty of Medicine and Dentistry, Universitat de València, 46010 Valencia, Spain
4 shared publications - Rocío Cascos
Collaborating Professor of Postgraduate Specialist in Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid (UCM), Madrid, Spain
3 shared publications - Alicia Celemín-Viñuela
Department of Prosthodontics, Faculty of Dentistry, University Complutense of Madrid, 28040 Madrid, Spain
2 shared publications - Jaime Del Río Highsmith
Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain
2 shared publications
Latest Publications
- Open Access
Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns
Background: Dental implant abutment screw loosening is an increasingly common problem, as evidenced by multiple studies that have investigated its causes. The objective of this study was to compare the screw loosening torque values before and after cyclic loading and to determine whether they are affected by the CAD/CAM abutment manufacturing technique (machined or laser-sintered) and abutment angulation. Materials and Methods: Ninety implants were used and divided into two groups: 45 implants received machined abutments (group A) and 45 implants received laser-sintered abutments (group B). Each group was further divided into three subgroups, with 15 implants each, based on the abutment angulation involved (0°, 15° and 20°). The abutments were tightened to the torque recommended by the manufacturer, and the reverse torque value was measured before and after cyclic loading (300,000 cycles). Data analysis was performed using one-way ANOVA and Wilcoxon signed-rank tests. Results: Statistically significant differences were observed between the laser-sintered and machined groups (p < 0.01). Additionally, differences were observed between subgroups with different angulations for both machined (16.2 ± 1.75, 14.7 ± 1.74 and 13.4 ± 1.08 Ncm) and laser-sintered abutments (14.6 ± 1.25, 12.7 ± 1.2 and 11.1 ± 1.35 Ncm) (0°, 15° and 20°, respectively). Conclusions: The final screw loosening torque after cyclic loading was lower than the initial loosening torque. Both abutment angulation and the CAD/CAM manufacturing method exerted a statistically significant influence on the final loosening torque. The abutment angulation factor was estimated to have an influence of 34.5%, while the abutment manufacturing method was estimated to have an influence of 21%.
Open AccessInfluence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns
Background: Dental implant abutment screw loosening is an increasingly common problem, as evidenced by multiple studies that have investigated its causes. The objective of this study was to compare the screw loosening torque values before and after cyclic loading and to determine whether they are affected by the CAD/CAM abutment manufacturing technique (machined or laser-sintered) and abutment angulation. Materials and Methods: Ninety implants were used and divided into two groups: 45 implants received machined abutments (group A) and 45 implants received laser-sintered abutments (group B). Each group was further divided into three subgroups, with 15 implants each, based on the abutment angulation involved (0°, 15° and 20°). The abutments were tightened to the torque recommended by the manufacturer, and the reverse torque value was measured before and after cyclic loading (300,000 cycles). Data analysis was performed using one-way ANOVA and Wilcoxon signed-rank tests. Results: Statistically significant differences were observed between the laser-sintered and machined groups (p < 0.01). Additionally, differences were observed between subgroups with different angulations for both machined (16.2 ± 1.75, 14.7 ± 1.74 and 13.4 ± 1.08 Ncm) and laser-sintered abutments (14.6 ± 1.25, 12.7 ± 1.2 and 11.1 ± 1.35 Ncm) (0°, 15° and 20°, respectively). Conclusions: The final screw loosening torque after cyclic loading was lower than the initial loosening torque. Both abutment angulation and the CAD/CAM manufacturing method exerted a statistically significant influence on the final loosening torque. The abutment angulation factor was estimated to have an influence of 34.5%, while the abutment manufacturing method was estimated to have an influence of 21%.
- Open Access
- 31 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 2966
Influence of Printing Angulation on the Accuracy (Trueness and Precision) of the Position of Implant Analogs in 3D Models: An In Vitro Pilot Study
Background: With CAD-CAM, dental models are often fabricated by additive manufacturing (AM) methods. Dental models for implant prostheses involve the manual placement of analogs, which could affect their final fit. Therefore, in this experimental in vitro study, the accuracy of the analogs’ position in models printed using AM methods was examined by comparing three different printing orientations. Methods: An STL file was obtained by scanning a master model with an implant placed in the maxillary left central incisor position. Three study groups (n = 10) with varying printing orientation parameters were obtained (0, 45, and 90 degrees). They were digitalized with a laboratory scanner and evaluated with an analysis metrology program. Differences between 3D datasets were measured using the RMS for trueness and SD RMS for precision. The data were statistically analyzed using the ANOVA test at a significance level of p < 0.05, followed by the Bonferroni post hoc test. Results: The 45-degrees group showed the best results. Regarding trueness, statistically significant differences were found between the 45- and 90-degrees groups (p < 0.005). In terms of precision, statistically significant differences appeared between the 45- and 0-degrees groups (p < 0.011) and between the 45- and 90-degrees groups (0.003). Conclusions: The printing angulation parameter affects the accuracy of 3D-printed models. Implant models manufactured at 45 degrees of printing angulation are more accurate than those printed at 0 or 90 degrees.
- 31 March 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 2966
Open AccessInfluence of Printing Angulation on the Accuracy (Trueness and Precision) of the Position of Implant Analogs in 3D Models: An In Vitro Pilot Study
Background: With CAD-CAM, dental models are often fabricated by additive manufacturing (AM) methods. Dental models for implant prostheses involve the manual placement of analogs, which could affect their final fit. Therefore, in this experimental in vitro study, the accuracy of the analogs’ position in models printed using AM methods was examined by comparing three different printing orientations. Methods: An STL file was obtained by scanning a master model with an implant placed in the maxillary left central incisor position. Three study groups (n = 10) with varying printing orientation parameters were obtained (0, 45, and 90 degrees). They were digitalized with a laboratory scanner and evaluated with an analysis metrology program. Differences between 3D datasets were measured using the RMS for trueness and SD RMS for precision. The data were statistically analyzed using the ANOVA test at a significance level of p < 0.05, followed by the Bonferroni post hoc test. Results: The 45-degrees group showed the best results. Regarding trueness, statistically significant differences were found between the 45- and 90-degrees groups (p < 0.005). In terms of precision, statistically significant differences appeared between the 45- and 0-degrees groups (p < 0.011) and between the 45- and 90-degrees groups (0.003). Conclusions: The printing angulation parameter affects the accuracy of 3D-printed models. Implant models manufactured at 45 degrees of printing angulation are more accurate than those printed at 0 or 90 degrees.
- Open Access
Influence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant–Abutment Interface: An In Vitro Study
This in vitro study aimed to assess the presence of microgaps at the implant–abutment interface in monolithic zirconia partial implant-supported fixed prostheses on transepithelial abutments versus Ti-base abutments. Methods: Sixty conical connection dental implants were divided into two groups (n = 30). The control group consisted of three-unit bridge monolithic zirconia connected to two implants by a transepithelial abutment. The test group consisted of monolithic zirconia three-unit restoration connected to two implants directly by a titanium base (Ti-base) abutment. The sample was subjected to thermocycling (10,000 cycles at 5 °C to 55 °C, dwelling time 50 s) and chewing simulation (300,000 cycles, under 200 N at frequencies of 2 Hz, at a 30° angle). The microgap was evaluated at six points (mesiobuccal, buccal, distobuccal, mesiolingual, lingual, and distolingual) of each implant–abutment interface by using a scanning electron microscope (SEM). The data were analyzed using the Mann–Whitney U tests (p > 0.05). Results: The SEM analysis showed a smaller microgap at the implant–abutment interface in the control group (0.270 μm) than in the test group (3.902 μm). Statistically significant differences were observed between both groups (p < 0.05). Conclusions: The use or not of transepithelial abutments affects the microgap size. The transepithelial abutments group presented lower microgap values at the interface with the implant than the Ti-base group in monolithic zirconia partial implant-supported fixed prostheses. However, both groups had microgap values within the clinically acceptable range.
Open AccessInfluence of the Use of Transepithelial Abutments vs. Titanium Base Abutments on Microgap Formation at the Dental Implant–Abutment Interface: An In Vitro Study
This in vitro study aimed to assess the presence of microgaps at the implant–abutment interface in monolithic zirconia partial implant-supported fixed prostheses on transepithelial abutments versus Ti-base abutments. Methods: Sixty conical connection dental implants were divided into two groups (n = 30). The control group consisted of three-unit bridge monolithic zirconia connected to two implants by a transepithelial abutment. The test group consisted of monolithic zirconia three-unit restoration connected to two implants directly by a titanium base (Ti-base) abutment. The sample was subjected to thermocycling (10,000 cycles at 5 °C to 55 °C, dwelling time 50 s) and chewing simulation (300,000 cycles, under 200 N at frequencies of 2 Hz, at a 30° angle). The microgap was evaluated at six points (mesiobuccal, buccal, distobuccal, mesiolingual, lingual, and distolingual) of each implant–abutment interface by using a scanning electron microscope (SEM). The data were analyzed using the Mann–Whitney U tests (p > 0.05). Results: The SEM analysis showed a smaller microgap at the implant–abutment interface in the control group (0.270 μm) than in the test group (3.902 μm). Statistically significant differences were observed between both groups (p < 0.05). Conclusions: The use or not of transepithelial abutments affects the microgap size. The transepithelial abutments group presented lower microgap values at the interface with the implant than the Ti-base group in monolithic zirconia partial implant-supported fixed prostheses. However, both groups had microgap values within the clinically acceptable range.
- 23 March 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (1) , 119-127
Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans
- 23 March 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (1) , 119-127
Influence of implant angulation and clinical implant scan body height on the accuracy of complete arch intraoral digital scans
- Open Access
- 27 December 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (1) , 125
A Novel Technique Using Polytetrafluoroethylene Tape to Solve Screw Loosening Complication in Implant-Supported Single Crowns
This study aimed to analyze a novel technique to make screws with greater untightening resistance and to solve screw loosening in implant-supported single crowns. Thirty grade IV titanium straight abutments were screwed onto 30 external hex implants using grade IV titanium screws (30 Ncm). They were exposed to cyclic loading (300,000 cycles, 200 N). Samples were divided into 4 groups (15 samples per group): new screws (SCREW group) (control), reused screws (rSCREW group), new screws wrapped with polytetrafluoroethylene (PTFE) tape (PTFE group), and reused screws wrapped with PTFE tape (rPTFE group). Reverse torque values (RTVs) were recorded with a digitally calibrated implant motor. Mean RTVs observed were 14.46 N (±1.10 N) for the control group, 14.42 N (±1.22 N) for the rSCREW group, 19.97 N (±1.16 N) for the PTFE group, and 19.13 N (±2.38 N) for the rPTFE group. Statistically significant differences were found between RTVs of both groups employing screws without PTFE tape (SCREW and rSCREW groups) compared with those using screws wrapped with PTFE tape (PTFE and rPTFE) (p < 0.001). These results suggest that wrapping the implant–abutment screw with PTFE tape may effectively lower the risk of loosening and even constitute a solution when this complication occurs in implant single crowns.
- 27 December 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (1) , 125
Open AccessA Novel Technique Using Polytetrafluoroethylene Tape to Solve Screw Loosening Complication in Implant-Supported Single Crowns
This study aimed to analyze a novel technique to make screws with greater untightening resistance and to solve screw loosening in implant-supported single crowns. Thirty grade IV titanium straight abutments were screwed onto 30 external hex implants using grade IV titanium screws (30 Ncm). They were exposed to cyclic loading (300,000 cycles, 200 N). Samples were divided into 4 groups (15 samples per group): new screws (SCREW group) (control), reused screws (rSCREW group), new screws wrapped with polytetrafluoroethylene (PTFE) tape (PTFE group), and reused screws wrapped with PTFE tape (rPTFE group). Reverse torque values (RTVs) were recorded with a digitally calibrated implant motor. Mean RTVs observed were 14.46 N (±1.10 N) for the control group, 14.42 N (±1.22 N) for the rSCREW group, 19.97 N (±1.16 N) for the PTFE group, and 19.13 N (±2.38 N) for the rPTFE group. Statistically significant differences were found between RTVs of both groups employing screws without PTFE tape (SCREW and rSCREW groups) compared with those using screws wrapped with PTFE tape (PTFE and rPTFE) (p < 0.001). These results suggest that wrapping the implant–abutment screw with PTFE tape may effectively lower the risk of loosening and even constitute a solution when this complication occurs in implant single crowns.
- Open Access
- 7 September 2020
- Published by MDPI AG in Prosthesis
- Vol. 2 (3) , 240-245
Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
This article aimed to assess the marginal fit of methacrylate-oligomer-phosphine-oxide curable-resin provisional-fixed dental prostheses made by digital-light-processing (DLP) three-dimensional (3D) printing. A stainless-steel master model with two abutments was scanned, and five three-unit provisional bridges were designed and printed in VITA shade A3.5 curable resin in 50 μm-thick layers. The marginal fit of each abutment was measured at six points using a profile projector. A descriptive data analysis of the fit measurements was performed by descriptive and explorative processes with the SPSS software. The curable-resin provisional restorations made by DLP 3D printing reached values of 46.37 μm (SD: 29.58 μm), which were considered clinically acceptable, with values similar to polyethylene-methacrylate and polyether-ether-ketone provisional restorations.
- 7 September 2020
- Published by MDPI AG in Prosthesis
- Vol. 2 (3) , 240-245
Open AccessPreliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
This article aimed to assess the marginal fit of methacrylate-oligomer-phosphine-oxide curable-resin provisional-fixed dental prostheses made by digital-light-processing (DLP) three-dimensional (3D) printing. A stainless-steel master model with two abutments was scanned, and five three-unit provisional bridges were designed and printed in VITA shade A3.5 curable resin in 50 μm-thick layers. The marginal fit of each abutment was measured at six points using a profile projector. A descriptive data analysis of the fit measurements was performed by descriptive and explorative processes with the SPSS software. The curable-resin provisional restorations made by DLP 3D printing reached values of 46.37 μm (SD: 29.58 μm), which were considered clinically acceptable, with values similar to polyethylene-methacrylate and polyether-ether-ketone provisional restorations.
- Open Access
Comparative In Vitro Study of the Bond Strength of Composite to Carbon Fiber Versus Ceramic to Cobalt–Chromium Alloys Frameworks for Fixed Dental Prostheses
Purpose: The aim of this comparative in vitro study was to assess the bond strength and mechanical failure of carbon-fiber-reinforced composites against cobalt–chrome structures with ceramic veneering. Materials and methods: A total of 24 specimens (12 per group) simulating dental prosthetic frameworks were fabricated. The experimental specimens were subjected to a thermocycling aging process and to evaluate bond strength. All specimens were subjected to a three-point bending test to fracture using a universal testing machine. Results: The cobalt–chrome/ceramic group yielded a bond strength value of 21.71 ± 2.16 MPa, while the carbon-fiber-reinforced composite group showed 14.50 ± 3.50 MPa. The failure assessment reported statistical significance between groups. Although carbon-fiber-reinforced composite group showed lower bond strength values, the chipping incidence in this group was as well lower. Conclusions: The chrome–cobalt/ceramic group showed greater bonding strength compared to the carbon-fiber-reinforced composite; most of the fractures within the cobalt–chrome/ceramic group, had no possibility of direct clinical repair.
Open AccessComparative In Vitro Study of the Bond Strength of Composite to Carbon Fiber Versus Ceramic to Cobalt–Chromium Alloys Frameworks for Fixed Dental Prostheses
Purpose: The aim of this comparative in vitro study was to assess the bond strength and mechanical failure of carbon-fiber-reinforced composites against cobalt–chrome structures with ceramic veneering. Materials and methods: A total of 24 specimens (12 per group) simulating dental prosthetic frameworks were fabricated. The experimental specimens were subjected to a thermocycling aging process and to evaluate bond strength. All specimens were subjected to a three-point bending test to fracture using a universal testing machine. Results: The cobalt–chrome/ceramic group yielded a bond strength value of 21.71 ± 2.16 MPa, while the carbon-fiber-reinforced composite group showed 14.50 ± 3.50 MPa. The failure assessment reported statistical significance between groups. Although carbon-fiber-reinforced composite group showed lower bond strength values, the chipping incidence in this group was as well lower. Conclusions: The chrome–cobalt/ceramic group showed greater bonding strength compared to the carbon-fiber-reinforced composite; most of the fractures within the cobalt–chrome/ceramic group, had no possibility of direct clinical repair.