TOTakako Ono

Takako Ono

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takako Ono has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Akiko Sugawara

    Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University Hospital, Fukushima, Japan

    1 shared publication
  • Hiroyasu Yasuda

    Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University Hospital

    1 shared publication
  • Hitoshi Ohto

    Radiation Medical Science Center for the Fukushima Health Management Survey, Fukushima Medical University, Fukushima 960-1295, Japan

    1 shared publication
  • Keiji Minakawa

    Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University School of Medicine, Fukushima 960-1295, Japan

    1 shared publication
  • Kenneth E. Nollet

    Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University Hospital, Fukushima, Japan

    1 shared publication
  • Kinuyo Kawabata

    Department of Blood Transfusion and Transplantation Immunology, Fukushima Medical University Hospital, Fukushima, Japan

    1 shared publication

Latest Publications

  • Open Access

    Comparative study of two automated pre-transfusion testing systems (microplate and gel column methods) with standard tube technique

    by Takako Ono, Hitoshi Ohto, Hiroyasu Yasuda, Rie Hikichi, Kinuyo Kawabata, Keiji Minakawa, Satoshi Ono, Masami Kikuchi, Akiko Sugawara, Shunnichi Saito, et al.

    Aims: Clinically significant antibodies may become undetectable and still provoke transfusion reactions. Hemolysis has been reported among transfusion recipients with anti-Kidd that was undetectable by gel column but detectable by other methods. Methods: We compared two automated technologies - microplate (MP) and gel column (GC) methods - with manual methods in ABO/RhD typing, irregular antibody screening, identification, titration, and detection threshold of mixed-field agglutination. Results: Automated systems agreed generally with tube results in 98% or more of ABO forward and RhD groupings, but showed weaker reactions in ABO reverse testing against A1 (K=0.88 with MP and K=0.77 with GC) and B cells (K=0.66 with MP and K=0.68 with GC) and failed to detect some anti-A (2 of 273 samples with MP) and anti-B (2 of 273 with MP and 1 of 272 with GC). MP missed 2 (anti-E and –Fyb) of 8 antibodies and GC missed 5 (2 anti-E and 1 each of -Fyb, -Jka and –Lea) of 10 antibodies, which manual PEG-IAT detected. Among 11 known alloantibodies, MP detected 7 antibodies at higher dilution than tube PEG-IAT, whereas GC showed lower scores in 7 samples than tube PEG-IAT and missed 2 clinically significant antibodies (anti-C and anti-Fyb). Conclusion: Automated systems, comparable to manual tube technique for forward grouping of ABO and RhD, are less sensitive in ABO reverse testing. As GC more often failed to detect clinically significant antibodies of low-titer, users should be especially mindful of possible post-transfusion hemolysis.