Comparative study of two automated pre-transfusion testing systems (microplate and gel column methods) with standard tube technique
Open Access
- 16 May 2017
- journal article
- Published by Edorium Journals Pvt. Ltd. in International Journal of Blood Transfusion and Immunohematology
- Vol. 7 (1) , 1-11
Abstract
Aims: Clinically significant antibodies may become undetectable and still provoke transfusion reactions. Hemolysis has been reported among transfusion recipients with anti-Kidd that was undetectable by gel column but detectable by other methods. Methods: We compared two automated technologies - microplate (MP) and gel column (GC) methods - with manual methods in ABO/RhD typing, irregular antibody screening, identification, titration, and detection threshold of mixed-field agglutination. Results: Automated systems agreed generally with tube results in 98% or more of ABO forward and RhD groupings, but showed weaker reactions in ABO reverse testing against A1 (K=0.88 with MP and K=0.77 with GC) and B cells (K=0.66 with MP and K=0.68 with GC) and failed to detect some anti-A (2 of 273 samples with MP) and anti-B (2 of 273 with MP and 1 of 272 with GC). MP missed 2 (anti-E and –Fyb) of 8 antibodies and GC missed 5 (2 anti-E and 1 each of -Fyb, -Jka and –Lea) of 10 antibodies, which manual PEG-IAT detected. Among 11 known alloantibodies, MP detected 7 antibodies at higher dilution than tube PEG-IAT, whereas GC showed lower scores in 7 samples than tube PEG-IAT and missed 2 clinically significant antibodies (anti-C and anti-Fyb). Conclusion: Automated systems, comparable to manual tube technique for forward grouping of ABO and RhD, are less sensitive in ABO reverse testing. As GC more often failed to detect clinically significant antibodies of low-titer, users should be especially mindful of possible post-transfusion hemolysis.Keywords
This publication has 13 references indexed in Scilit:
- Anti‐Jka that are detected by solid‐phase red blood cell adherence but missed by gel testing can cause hemolytic transfusion reactionsTransfusion, 2016
- Polyethylene glycol antiglobulin tube versus gel microcolumn: influence on the incidence of delayed hemolytic transfusion reactions and delayed serologic transfusion reactionsTransfusion, 2010
- Antibody identification using both automated solid‐phase red cell adherence assay and a tube polyethylene glycol antiglobulin methodTransfusion, 2008
- The United Kingdom National External Quality Assessment Scheme (Blood Transfusion Laboratory Practice): trends in proficiency and practice between 1985 and 2000Transfusion Medicine, 2002
- A fully automated blood typing system forhospital transfusion servicesTransfusion, 2000
- Comparison of the performance of four microtube column agglutination systems in the detection of red cell alloantibodiesTransfusion, 1999
- Evaluation of the gel system for ABO grouping and D typingTransfusion, 1999
- Evaluation of a new automated instrument for pretransfusion testingTransfusion, 1998
- Reports of 355 transfusion‐associated deaths: 1976 through 1985Transfusion, 1990
- Erythrocyte Antibody Screening in Solid-Phase: A Comparison of Two Solid-Phase Microplate Assays with the Indirect Antiglobulin Test in Polyethylene Glycol for the Detection of Irregular Erythrocyte Antibodies1990