Min Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Min Li has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Hongbo Jia
Advanced Institute for Brain and Intelligence, School of Physical Science and Technology, Guangxi University
6 shared publications - Zhenqiao Zhou
Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
5 shared publications - Jing Lyu
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
4 shared publications - Xiaowei Chen
Brain Research Center and State Key Laboratory of Trauma and Chemical Poisoning, Third Military Medical University, Chongqing, China
4 shared publications Hongbo Jia
University of Science and Technology of China
3 shared publicationsQinying Liu
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
3 shared publications
Latest Publications
- Open Access
- 13 April 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1)
Ultra-wide-field, deep, adaptive two-photon microscopy for multi-scale neuronal imaging
Observing the activity patterns of large neural populations throughout the brain is essential for understanding brain function. However, capturing neural interactions across widely distributed brain regions from both superficial and deep cortical layers remains challenging with existing microscopy technologies. Here, we introduce a state-of-the-art two-photon microscopy system, ULTRA, capable of single-cell resolution imaging across an ultra-large field of view (FOV) exceeding 50 mm², enabling deep and wide field in vivo imaging. To demonstrate its capabilities, we conducted a series of experiments under multiple imaging conditions, successfully visualizing brain structures and neuronal activities spanning a spatial range of over 7 mm from superficial layers to depths of up to 900 μm, while covering a volume of 45.24 mm 3 in the mouse brain. This versatile imaging platform overcomes traditional spatial constraints, providing a powerful tool for comprehensive exploration of neuronal circuitry over extensive spatial scales with cellular resolution.
- 13 April 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1)
Open AccessUltra-wide-field, deep, adaptive two-photon microscopy for multi-scale neuronal imaging
Observing the activity patterns of large neural populations throughout the brain is essential for understanding brain function. However, capturing neural interactions across widely distributed brain regions from both superficial and deep cortical layers remains challenging with existing microscopy technologies. Here, we introduce a state-of-the-art two-photon microscopy system, ULTRA, capable of single-cell resolution imaging across an ultra-large field of view (FOV) exceeding 50 mm², enabling deep and wide field in vivo imaging. To demonstrate its capabilities, we conducted a series of experiments under multiple imaging conditions, successfully visualizing brain structures and neuronal activities spanning a spatial range of over 7 mm from superficial layers to depths of up to 900 μm, while covering a volume of 45.24 mm 3 in the mouse brain. This versatile imaging platform overcomes traditional spatial constraints, providing a powerful tool for comprehensive exploration of neuronal circuitry over extensive spatial scales with cellular resolution.
- Open Access
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 13 (01) , 1-15
Cellular multipoint adaptive technology for two-photon mesoscope
SignificanceIn mesoscopic imaging research in neuroscience, achieving high spatial resolution optical imaging across the entire field of view (FOV) remains critical. This directly determines whether researchers can precisely analyze the large-scale dynamic activities of neural circuits at the single-cell or even subcellular level. Consistent optical quality throughout the entire imaging FOV is essential to accurately capture the spatiotemporal patterns of neural activity across brain regions, thereby providing a powerful tool for understanding the circuit mechanisms underlying cognition, behavior, and disease at cellular and subcellular resolution in vivo.AimThis study aims to develop a technology that extends the imaging FOV in a two-photon mesoscope while enhancing the optical quality across the entire FOV in vivo. The key point is to establish a robust method that can significantly extend the FOV beyond what the micro/mesoscope objective had been originally designed for, yet maintain the original resolution specifications. As such, the value of the method also extends beyond improving just one mesoscope, which we use as a demo in this study.ApproachThis study introduces an innovative approach that combines block scanning with adaptive optical (AO) correction through a bioinspired honeycomb-based cellular multipoint adaptive technology (CMAT) to achieve mesoscopic two-photon imaging. This system enables unprecedented large-FOV, high-resolution imaging by dividing an 8×8 mm2 imaging area into subregions, each pre-optimized with deformable mirror (DM) compensation while applying real-time dynamic wavefront correction during scanning. Furthermore, we have designed multiple user-defined sub-region scanning functions. Each sub-region automatically loads the aberration correction compensation values from the nearest reference point relative to its center, thereby ensuring optimal optical performance for every individual sub-region. The robustness of this technology has been systematically verified across multiple neural circuit observation scenarios using transgenic mouse models, demonstrating its capability for reliable single-cell resolution imaging across extensive brain regions.ResultsComprehensive evaluation using standard samples and transgenic mouse models demonstrated that the CMAT significantly enhances the imaging performance of the two-photon mesoscope. This technique extends the effective two-photon imaging FOV from 6×6 mm2 to 8×8 mm2 while markedly improving the optical quality in the peripheral regions. High resolution was maintained at ∼1 μm (lateral) and ∼10 μm (axial) in the central area, with edge regions achieving improved resolutions of ∼1.3 μm (lateral) and ∼14 μm (axial). Quantitative analysis confirmed that multipoint AO not only enhances image contrast and optical resolution but also substantially increases the signal-to-noise ratio (SNR) in Ca2+ imaging. This work delivers a pivotal technical advance for large-scale functional imaging of neural circuits.ConclusionCMAT significantly extends the effective FOV and enhances the optical quality of the two-photon mesoscope system.
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 13 (01) , 1-15
Open AccessCellular multipoint adaptive technology for two-photon mesoscope
SignificanceIn mesoscopic imaging research in neuroscience, achieving high spatial resolution optical imaging across the entire field of view (FOV) remains critical. This directly determines whether researchers can precisely analyze the large-scale dynamic activities of neural circuits at the single-cell or even subcellular level. Consistent optical quality throughout the entire imaging FOV is essential to accurately capture the spatiotemporal patterns of neural activity across brain regions, thereby providing a powerful tool for understanding the circuit mechanisms underlying cognition, behavior, and disease at cellular and subcellular resolution in vivo.AimThis study aims to develop a technology that extends the imaging FOV in a two-photon mesoscope while enhancing the optical quality across the entire FOV in vivo. The key point is to establish a robust method that can significantly extend the FOV beyond what the micro/mesoscope objective had been originally designed for, yet maintain the original resolution specifications. As such, the value of the method also extends beyond improving just one mesoscope, which we use as a demo in this study.ApproachThis study introduces an innovative approach that combines block scanning with adaptive optical (AO) correction through a bioinspired honeycomb-based cellular multipoint adaptive technology (CMAT) to achieve mesoscopic two-photon imaging. This system enables unprecedented large-FOV, high-resolution imaging by dividing an 8×8 mm2 imaging area into subregions, each pre-optimized with deformable mirror (DM) compensation while applying real-time dynamic wavefront correction during scanning. Furthermore, we have designed multiple user-defined sub-region scanning functions. Each sub-region automatically loads the aberration correction compensation values from the nearest reference point relative to its center, thereby ensuring optimal optical performance for every individual sub-region. The robustness of this technology has been systematically verified across multiple neural circuit observation scenarios using transgenic mouse models, demonstrating its capability for reliable single-cell resolution imaging across extensive brain regions.ResultsComprehensive evaluation using standard samples and transgenic mouse models demonstrated that the CMAT significantly enhances the imaging performance of the two-photon mesoscope. This technique extends the effective two-photon imaging FOV from 6×6 mm2 to 8×8 mm2 while markedly improving the optical quality in the peripheral regions. High resolution was maintained at ∼1 μm (lateral) and ∼10 μm (axial) in the central area, with edge regions achieving improved resolutions of ∼1.3 μm (lateral) and ∼14 μm (axial). Quantitative analysis confirmed that multipoint AO not only enhances image contrast and optical resolution but also substantially increases the signal-to-noise ratio (SNR) in Ca2+ imaging. This work delivers a pivotal technical advance for large-scale functional imaging of neural circuits.ConclusionCMAT significantly extends the effective FOV and enhances the optical quality of the two-photon mesoscope system.
- 10 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (21) , 5910-5918
Multi-objective desensitization design method for optical systems based on an improved NSGA-II
The stringent alignment and manufacturing tolerances required for optical elements pose significant challenges in system development, often leading to increased production time and cost. As these errors are often coupled, a desensitization design method that can synthesize multiple errors is essential. In this paper, a multi-error desensitization design method (MDDM) is proposed based on an improved NSGA-II, which introduces a variable adaptive binary coding method and adaptive crossover and mutation probabilities. We demonstrate the effectiveness of the MDDM through its application to two distinct optical systems: a telephoto objective and a catadioptric telescope. The results reveal significant performance improvements over conventional optical design software approaches, with average sensitivity reductions of 28.1% and 19.2% for the respective systems.
- 10 July 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (21) , 5910-5918
Multi-objective desensitization design method for optical systems based on an improved NSGA-II
The stringent alignment and manufacturing tolerances required for optical elements pose significant challenges in system development, often leading to increased production time and cost. As these errors are often coupled, a desensitization design method that can synthesize multiple errors is essential. In this paper, a multi-error desensitization design method (MDDM) is proposed based on an improved NSGA-II, which introduces a variable adaptive binary coding method and adaptive crossover and mutation probabilities. We demonstrate the effectiveness of the MDDM through its application to two distinct optical systems: a telephoto objective and a catadioptric telescope. The results reveal significant performance improvements over conventional optical design software approaches, with average sensitivity reductions of 28.1% and 19.2% for the respective systems.
- 1 October 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (21) , 37211-37223
Adaptive multi-surrogate model for complex opto-mechanical system alignment
Owing to the inherent nonlinearity of surrogate models, they have been widely used in the alignment of complex opto-mechanical systems. Finding the most suitable surrogate model for misalignment wavefront errors is challenging. This study proposes an adaptive multi-surrogate model (AMSM) based on the concept of layer-by-layer approximation and adaptive selection and a compensation mechanism to facilitate the combination of the AMSM and non-dominated sorting genetic algorithm II (NSGA-II). For example, alignment simulations of an off-axis three-mirror anastigmatic (TMA) telescope and a catadioptric microscope objective were performed. The results show that the AMSM is well done in terms of approximate accuracy and efficiency. The application of the proposed method in the off-axis TMA telescope leads to 65.2% and 18.7% reductions in the full-field average RMS wavefront error compared with the traditional sensitivity table method (STM) and radial basis function (RBF) network surrogate model, respectively. Similarly, for the catadioptric microscope objective, there is a reduction of 43.5% and 22.4%, respectively. The AMSM will further promote the development of a surrogate model to align more complex and precise opto-mechanical systems.
- 1 October 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (21) , 37211-37223
Adaptive multi-surrogate model for complex opto-mechanical system alignment
Owing to the inherent nonlinearity of surrogate models, they have been widely used in the alignment of complex opto-mechanical systems. Finding the most suitable surrogate model for misalignment wavefront errors is challenging. This study proposes an adaptive multi-surrogate model (AMSM) based on the concept of layer-by-layer approximation and adaptive selection and a compensation mechanism to facilitate the combination of the AMSM and non-dominated sorting genetic algorithm II (NSGA-II). For example, alignment simulations of an off-axis three-mirror anastigmatic (TMA) telescope and a catadioptric microscope objective were performed. The results show that the AMSM is well done in terms of approximate accuracy and efficiency. The application of the proposed method in the off-axis TMA telescope leads to 65.2% and 18.7% reductions in the full-field average RMS wavefront error compared with the traditional sensitivity table method (STM) and radial basis function (RBF) network surrogate model, respectively. Similarly, for the catadioptric microscope objective, there is a reduction of 43.5% and 22.4%, respectively. The AMSM will further promote the development of a surrogate model to align more complex and precise opto-mechanical systems.
- Open Access
- 7 December 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-14
Holistic bursting cells store long-term memory in auditory cortex
The sensory neocortex has been suggested to be a substrate for long-term memory storage, yet which exact single cells could be specific candidates underlying such long-term memory storage remained neither known nor visible for over a century. Here, using a combination of day-by-day two-photon Ca2+ imaging and targeted single-cell loose-patch recording in an auditory associative learning paradigm with composite sounds in male mice, we reveal sparsely distributed neurons in layer 2/3 of auditory cortex emerged step-wise from quiescence into bursting mode, which then invariably expressed holistic information of the learned composite sounds, referred to as holistic bursting (HB) cells. Notably, it was not shuffled populations but the same sparse HB cells that embodied the behavioral relevance of the learned composite sounds, pinpointing HB cells as physiologically-defined single-cell candidates of an engram underlying long-term memory storage in auditory cortex.
- 7 December 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-14
Open AccessHolistic bursting cells store long-term memory in auditory cortex
The sensory neocortex has been suggested to be a substrate for long-term memory storage, yet which exact single cells could be specific candidates underlying such long-term memory storage remained neither known nor visible for over a century. Here, using a combination of day-by-day two-photon Ca2+ imaging and targeted single-cell loose-patch recording in an auditory associative learning paradigm with composite sounds in male mice, we reveal sparsely distributed neurons in layer 2/3 of auditory cortex emerged step-wise from quiescence into bursting mode, which then invariably expressed holistic information of the learned composite sounds, referred to as holistic bursting (HB) cells. Notably, it was not shuffled populations but the same sparse HB cells that embodied the behavioral relevance of the learned composite sounds, pinpointing HB cells as physiologically-defined single-cell candidates of an engram underlying long-term memory storage in auditory cortex.
- 15 July 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 2 (7) , 1716-1734
PDTANet: a context-guided and attention-aware deep learning method for tumor segmentation of guinea pig colorectal OCT images
Optical coherence tomography (OCT) technology has significant potential value in the application of early gastrointestinal tumor screening and intraoperative guidance. In the application of diagnosing gastrointestinal diseases, a key step of OCT image intelligent analysis system is to segment the tissues and layers accurately. In this paper, we propose a new encoder-decoder network named PDTANet, which contains a global context-guided PDFF module and a lightweight attention-aware triplet attention (TA) mechanism. Moreover, during the model training stage, we adopt a region-aware and boundary-aware hybrid loss function to learn and update model parameters. The proposed PDTANet model has been applied for automatic tumor segmentation of guinea pig colorectal OCT images. The experimental results show that our proposed PDTANet model has the ability to focus on and connect global context and important feature information for OCT images. Compared with the prediction results of the model trained by the traditional Unet model and Dice loss function, the PDTANet model and a combination of dice and boundary related loss function proposed as the hybrid loss function proposed in this paper have significantly improved the accuracy of the segmentation of tissue boundaries, especially the surface Dice metric, which is improved by about 3%.
- 15 July 2023
- Published by Optica Publishing Group in Optics Continuum
- Vol. 2 (7) , 1716-1734
PDTANet: a context-guided and attention-aware deep learning method for tumor segmentation of guinea pig colorectal OCT images
Optical coherence tomography (OCT) technology has significant potential value in the application of early gastrointestinal tumor screening and intraoperative guidance. In the application of diagnosing gastrointestinal diseases, a key step of OCT image intelligent analysis system is to segment the tissues and layers accurately. In this paper, we propose a new encoder-decoder network named PDTANet, which contains a global context-guided PDFF module and a lightweight attention-aware triplet attention (TA) mechanism. Moreover, during the model training stage, we adopt a region-aware and boundary-aware hybrid loss function to learn and update model parameters. The proposed PDTANet model has been applied for automatic tumor segmentation of guinea pig colorectal OCT images. The experimental results show that our proposed PDTANet model has the ability to focus on and connect global context and important feature information for OCT images. Compared with the prediction results of the model trained by the traditional Unet model and Dice loss function, the PDTANet model and a combination of dice and boundary related loss function proposed as the hybrid loss function proposed in this paper have significantly improved the accuracy of the segmentation of tissue boundaries, especially the surface Dice metric, which is improved by about 3%.
- Open Access
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 10 (02) , 025006-16
Ten-kilohertz two-photon microscopy imaging of single-cell dendritic activity and hemodynamics in vivo
SignificanceThe studying of rapid neuronal signaling across large spatial scales in intact, living brains requires both high temporal resolution and versatility of the measurement device.AimWe introduce a high-speed two-photon microscope based on a custom-built acousto-optic deflector (AOD). This microscope has a maximum line scan frequency of 400 kHz and a maximum frame rate of 10,000 frames per second (fps) at 250 × 40 pixels. For stepwise magnification from population view to subcellular view with high spatial and temporal resolution, we combined the AOD with resonance-galvo (RS) scanning.ApproachWith this combinatorial device that supports both large-view navigation and small-view high-speed imaging, we measured dendritic calcium propagation velocity and the velocity of single red blood cells (RBCs).ResultsWe measured dendritic calcium propagation velocity (80 / 62.5 − 116.7 μm / ms) in OGB-1-labeled single cortical neurons in mice in vivo. To benchmark the spatial precision and detection sensitivity of measurement in vivo, we also visualized the trajectories of single RBCs and found that their movement speed follows Poiseuille’s law of laminar flow.ConclusionsThis proof-of-concept methodological development shows that the combination of AOD and RS scanning two-photon microscopy provides both versatility and precision for quantitative analysis of single neuronal activities and hemodynamics in vivo.
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 10 (02) , 025006-16
Open AccessTen-kilohertz two-photon microscopy imaging of single-cell dendritic activity and hemodynamics in vivo
SignificanceThe studying of rapid neuronal signaling across large spatial scales in intact, living brains requires both high temporal resolution and versatility of the measurement device.AimWe introduce a high-speed two-photon microscope based on a custom-built acousto-optic deflector (AOD). This microscope has a maximum line scan frequency of 400 kHz and a maximum frame rate of 10,000 frames per second (fps) at 250 × 40 pixels. For stepwise magnification from population view to subcellular view with high spatial and temporal resolution, we combined the AOD with resonance-galvo (RS) scanning.ApproachWith this combinatorial device that supports both large-view navigation and small-view high-speed imaging, we measured dendritic calcium propagation velocity and the velocity of single red blood cells (RBCs).ResultsWe measured dendritic calcium propagation velocity (80 / 62.5 − 116.7 μm / ms) in OGB-1-labeled single cortical neurons in mice in vivo. To benchmark the spatial precision and detection sensitivity of measurement in vivo, we also visualized the trajectories of single RBCs and found that their movement speed follows Poiseuille’s law of laminar flow.ConclusionsThis proof-of-concept methodological development shows that the combination of AOD and RS scanning two-photon microscopy provides both versatility and precision for quantitative analysis of single neuronal activities and hemodynamics in vivo.
- 1 November 2022
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 15 (6) , 1167-1181
In-vivo across-scales two-photon microscopic imaging technique
Two-photon microscopy's ability to maintain good spatial resolution in thick biological tissues has led to its application in in-vivo brain imaging studies soon after its conception. As neural networks have cross-scale multidimensional spatio-temporal properties, two-photon microscopy has developed rapidly and significantly in recent years to meet the demand for in-vivo cross-scale imaging of the brain. This paper firstly introduces the working principle of two-photon microscopy, then reviews the progress of two-photon microscopy from five perspectives: imaging field of view, imaging flux, imaging depth, resolution, miniaturization, and analyzes the difficulties and future challenges of cross-scale two-photon in-vivo microscopic imaging technology.
- 1 November 2022
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 15 (6) , 1167-1181
In-vivo across-scales two-photon microscopic imaging technique
Two-photon microscopy's ability to maintain good spatial resolution in thick biological tissues has led to its application in in-vivo brain imaging studies soon after its conception. As neural networks have cross-scale multidimensional spatio-temporal properties, two-photon microscopy has developed rapidly and significantly in recent years to meet the demand for in-vivo cross-scale imaging of the brain. This paper firstly introduces the working principle of two-photon microscopy, then reviews the progress of two-photon microscopy from five perspectives: imaging field of view, imaging flux, imaging depth, resolution, miniaturization, and analyzes the difficulties and future challenges of cross-scale two-photon in-vivo microscopic imaging technology.
- Open Access
Optical Fiber-Based Recording of Climbing Fiber Ca2+ Signals in Freely Behaving Mice
The olivocerebellar circuitry is important to convey both motor and non-motor information from the inferior olive (IO) to the cerebellar cortex. Several methods are currently established to observe the dynamics of the olivocerebellar circuitry, largely by recording the complex spike activity of cerebellar Purkinje cells; however, these techniques can be technically challenging to apply in vivo and are not always possible in freely behaving animals. Here, we developed a method for the direct, accessible, and robust recording of climbing fiber (CF) Ca2+ signals based on optical fiber photometry. We first verified the IO stereotactic coordinates and the organization of contralateral CF projections using tracing techniques and then injected Ca2+ indicators optimized for axonal labeling, followed by optical fiber-based recordings. We demonstrated this method by recording CF Ca2+ signals in lobule IV/V of the cerebellar vermis, comparing the resulting signals in freely moving mice. We found various movement-evoked CF Ca2+ signals, but the onset of exploratory-like behaviors, including rearing and tiptoe standing, was highly synchronous with recorded CF activity. Thus, we have successfully established a robust and accessible method to record the CF Ca2+ signals in freely behaving mice, which will extend the toolbox for studying cerebellar function and related disorders.
Open AccessOptical Fiber-Based Recording of Climbing Fiber Ca2+ Signals in Freely Behaving Mice
The olivocerebellar circuitry is important to convey both motor and non-motor information from the inferior olive (IO) to the cerebellar cortex. Several methods are currently established to observe the dynamics of the olivocerebellar circuitry, largely by recording the complex spike activity of cerebellar Purkinje cells; however, these techniques can be technically challenging to apply in vivo and are not always possible in freely behaving animals. Here, we developed a method for the direct, accessible, and robust recording of climbing fiber (CF) Ca2+ signals based on optical fiber photometry. We first verified the IO stereotactic coordinates and the organization of contralateral CF projections using tracing techniques and then injected Ca2+ indicators optimized for axonal labeling, followed by optical fiber-based recordings. We demonstrated this method by recording CF Ca2+ signals in lobule IV/V of the cerebellar vermis, comparing the resulting signals in freely moving mice. We found various movement-evoked CF Ca2+ signals, but the onset of exploratory-like behaviors, including rearing and tiptoe standing, was highly synchronous with recorded CF activity. Thus, we have successfully established a robust and accessible method to record the CF Ca2+ signals in freely behaving mice, which will extend the toolbox for studying cerebellar function and related disorders.
- 1 January 2022
- Vol. 26 (20) , 7349-7358
Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning
OBJECTIVE: In order to solve the problem of image real-time processing and correction for high-speed endoscopic swept-source optical coherence tomography (SS-OCT), we highly optimize a computer-unified device architecture-based platform and use a field-programmable gate array to summarize the application experience. MATERIALS AND METHODS: We use the Half-Sync/Half-Asyn mode to optimize memory in order to build a high-throughput data thread pool for CPU. We use asynchronous streaming architecture to multiplex multiple threads at high speed to accelerate data processing. At the same time, we design a rotary scanning position information encoding feedback module to suppress image drift, which can realize 25ns logic-timing sequence synchronization control through FPGA 40MHz clock. RESULTS: The maximum complete attainable axial-scan-processing rate (including memory transfer and display of B-scan frames) is 3.52 MHz for a 16-bit pixel depth and A-scans/s of 1024 pixels. To our knowledge, this is the fastest processing rate reported to date with a single-chip graphical processing unit for SS-OCT. Finally, the established high-speed SS-OCT is used to image mouse esophagus and human fingers, and the output images are stable. When the image size is 1024 x 1024 pixels, the real-time imaging rate is 200 frames per second. CONCLUSIONS: This paper develops a real-time image processing and reconstruction technology suitable for high-throughput SS-OCT systems, which can have high-density operation and efficient parallelism, while suppressing high-speed image drift. It lays the foundation for the non-destructive, in vivo, non-staining, fast and convenient early tumor diagnosis of high-speed endoscopic SS-OCT.
- 1 January 2022
- Vol. 26 (20) , 7349-7358
Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning
OBJECTIVE: In order to solve the problem of image real-time processing and correction for high-speed endoscopic swept-source optical coherence tomography (SS-OCT), we highly optimize a computer-unified device architecture-based platform and use a field-programmable gate array to summarize the application experience. MATERIALS AND METHODS: We use the Half-Sync/Half-Asyn mode to optimize memory in order to build a high-throughput data thread pool for CPU. We use asynchronous streaming architecture to multiplex multiple threads at high speed to accelerate data processing. At the same time, we design a rotary scanning position information encoding feedback module to suppress image drift, which can realize 25ns logic-timing sequence synchronization control through FPGA 40MHz clock. RESULTS: The maximum complete attainable axial-scan-processing rate (including memory transfer and display of B-scan frames) is 3.52 MHz for a 16-bit pixel depth and A-scans/s of 1024 pixels. To our knowledge, this is the fastest processing rate reported to date with a single-chip graphical processing unit for SS-OCT. Finally, the established high-speed SS-OCT is used to image mouse esophagus and human fingers, and the output images are stable. When the image size is 1024 x 1024 pixels, the real-time imaging rate is 200 frames per second. CONCLUSIONS: This paper develops a real-time image processing and reconstruction technology suitable for high-throughput SS-OCT systems, which can have high-density operation and efficient parallelism, while suppressing high-speed image drift. It lays the foundation for the non-destructive, in vivo, non-staining, fast and convenient early tumor diagnosis of high-speed endoscopic SS-OCT.