Jing Lyu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jing Lyu has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Hongbo Jia
Advanced Institute for Brain and Intelligence, School of Physical Science and Technology, Guangxi University
5 shared publications - Min Li
Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
4 shared publications - Xiaowei Chen
Brain Research Center and State Key Laboratory of Trauma and Chemical Poisoning, Third Military Medical University, Chongqing, China
4 shared publications - Zhenqiao Zhou
Brain Research Instrument Innovation Center, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
4 shared publications - Yuguo Tang
Affiliations Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China, Key Lab of Bio-Medical Diagnostics Chinese Academy of Sciences, Suzhou Institute of Biomedical Engineering and Technology, Suzhou, China
3 shared publications - Arthur Konnerth
Technical University of Munich
2 shared publications
Latest Publications
- Open Access
- 13 April 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1)
Ultra-wide-field, deep, adaptive two-photon microscopy for multi-scale neuronal imaging
Observing the activity patterns of large neural populations throughout the brain is essential for understanding brain function. However, capturing neural interactions across widely distributed brain regions from both superficial and deep cortical layers remains challenging with existing microscopy technologies. Here, we introduce a state-of-the-art two-photon microscopy system, ULTRA, capable of single-cell resolution imaging across an ultra-large field of view (FOV) exceeding 50 mm², enabling deep and wide field in vivo imaging. To demonstrate its capabilities, we conducted a series of experiments under multiple imaging conditions, successfully visualizing brain structures and neuronal activities spanning a spatial range of over 7 mm from superficial layers to depths of up to 900 μm, while covering a volume of 45.24 mm 3 in the mouse brain. This versatile imaging platform overcomes traditional spatial constraints, providing a powerful tool for comprehensive exploration of neuronal circuitry over extensive spatial scales with cellular resolution.
- 13 April 2026
- Published by Springer Nature in Light: Science & Applications
- Vol. 15 (1)
Open AccessUltra-wide-field, deep, adaptive two-photon microscopy for multi-scale neuronal imaging
Observing the activity patterns of large neural populations throughout the brain is essential for understanding brain function. However, capturing neural interactions across widely distributed brain regions from both superficial and deep cortical layers remains challenging with existing microscopy technologies. Here, we introduce a state-of-the-art two-photon microscopy system, ULTRA, capable of single-cell resolution imaging across an ultra-large field of view (FOV) exceeding 50 mm², enabling deep and wide field in vivo imaging. To demonstrate its capabilities, we conducted a series of experiments under multiple imaging conditions, successfully visualizing brain structures and neuronal activities spanning a spatial range of over 7 mm from superficial layers to depths of up to 900 μm, while covering a volume of 45.24 mm 3 in the mouse brain. This versatile imaging platform overcomes traditional spatial constraints, providing a powerful tool for comprehensive exploration of neuronal circuitry over extensive spatial scales with cellular resolution.
- Open Access
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 13 (01) , 1-15
Cellular multipoint adaptive technology for two-photon mesoscope
SignificanceIn mesoscopic imaging research in neuroscience, achieving high spatial resolution optical imaging across the entire field of view (FOV) remains critical. This directly determines whether researchers can precisely analyze the large-scale dynamic activities of neural circuits at the single-cell or even subcellular level. Consistent optical quality throughout the entire imaging FOV is essential to accurately capture the spatiotemporal patterns of neural activity across brain regions, thereby providing a powerful tool for understanding the circuit mechanisms underlying cognition, behavior, and disease at cellular and subcellular resolution in vivo.AimThis study aims to develop a technology that extends the imaging FOV in a two-photon mesoscope while enhancing the optical quality across the entire FOV in vivo. The key point is to establish a robust method that can significantly extend the FOV beyond what the micro/mesoscope objective had been originally designed for, yet maintain the original resolution specifications. As such, the value of the method also extends beyond improving just one mesoscope, which we use as a demo in this study.ApproachThis study introduces an innovative approach that combines block scanning with adaptive optical (AO) correction through a bioinspired honeycomb-based cellular multipoint adaptive technology (CMAT) to achieve mesoscopic two-photon imaging. This system enables unprecedented large-FOV, high-resolution imaging by dividing an 8×8 mm2 imaging area into subregions, each pre-optimized with deformable mirror (DM) compensation while applying real-time dynamic wavefront correction during scanning. Furthermore, we have designed multiple user-defined sub-region scanning functions. Each sub-region automatically loads the aberration correction compensation values from the nearest reference point relative to its center, thereby ensuring optimal optical performance for every individual sub-region. The robustness of this technology has been systematically verified across multiple neural circuit observation scenarios using transgenic mouse models, demonstrating its capability for reliable single-cell resolution imaging across extensive brain regions.ResultsComprehensive evaluation using standard samples and transgenic mouse models demonstrated that the CMAT significantly enhances the imaging performance of the two-photon mesoscope. This technique extends the effective two-photon imaging FOV from 6×6 mm2 to 8×8 mm2 while markedly improving the optical quality in the peripheral regions. High resolution was maintained at ∼1 μm (lateral) and ∼10 μm (axial) in the central area, with edge regions achieving improved resolutions of ∼1.3 μm (lateral) and ∼14 μm (axial). Quantitative analysis confirmed that multipoint AO not only enhances image contrast and optical resolution but also substantially increases the signal-to-noise ratio (SNR) in Ca2+ imaging. This work delivers a pivotal technical advance for large-scale functional imaging of neural circuits.ConclusionCMAT significantly extends the effective FOV and enhances the optical quality of the two-photon mesoscope system.
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 13 (01) , 1-15
Open AccessCellular multipoint adaptive technology for two-photon mesoscope
SignificanceIn mesoscopic imaging research in neuroscience, achieving high spatial resolution optical imaging across the entire field of view (FOV) remains critical. This directly determines whether researchers can precisely analyze the large-scale dynamic activities of neural circuits at the single-cell or even subcellular level. Consistent optical quality throughout the entire imaging FOV is essential to accurately capture the spatiotemporal patterns of neural activity across brain regions, thereby providing a powerful tool for understanding the circuit mechanisms underlying cognition, behavior, and disease at cellular and subcellular resolution in vivo.AimThis study aims to develop a technology that extends the imaging FOV in a two-photon mesoscope while enhancing the optical quality across the entire FOV in vivo. The key point is to establish a robust method that can significantly extend the FOV beyond what the micro/mesoscope objective had been originally designed for, yet maintain the original resolution specifications. As such, the value of the method also extends beyond improving just one mesoscope, which we use as a demo in this study.ApproachThis study introduces an innovative approach that combines block scanning with adaptive optical (AO) correction through a bioinspired honeycomb-based cellular multipoint adaptive technology (CMAT) to achieve mesoscopic two-photon imaging. This system enables unprecedented large-FOV, high-resolution imaging by dividing an 8×8 mm2 imaging area into subregions, each pre-optimized with deformable mirror (DM) compensation while applying real-time dynamic wavefront correction during scanning. Furthermore, we have designed multiple user-defined sub-region scanning functions. Each sub-region automatically loads the aberration correction compensation values from the nearest reference point relative to its center, thereby ensuring optimal optical performance for every individual sub-region. The robustness of this technology has been systematically verified across multiple neural circuit observation scenarios using transgenic mouse models, demonstrating its capability for reliable single-cell resolution imaging across extensive brain regions.ResultsComprehensive evaluation using standard samples and transgenic mouse models demonstrated that the CMAT significantly enhances the imaging performance of the two-photon mesoscope. This technique extends the effective two-photon imaging FOV from 6×6 mm2 to 8×8 mm2 while markedly improving the optical quality in the peripheral regions. High resolution was maintained at ∼1 μm (lateral) and ∼10 μm (axial) in the central area, with edge regions achieving improved resolutions of ∼1.3 μm (lateral) and ∼14 μm (axial). Quantitative analysis confirmed that multipoint AO not only enhances image contrast and optical resolution but also substantially increases the signal-to-noise ratio (SNR) in Ca2+ imaging. This work delivers a pivotal technical advance for large-scale functional imaging of neural circuits.ConclusionCMAT significantly extends the effective FOV and enhances the optical quality of the two-photon mesoscope system.
- Open Access
- 7 February 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 111 (4) , 2838-2848
Roving histological imaging for navigation-confirmed glioma negative margin by handheld endomicroscopy: a parallel controlled study
Introduction: Roving histopathological imaging in navigation-confirmed tumor negative margin has not been achieved during neurosurgery procedures. This study aims to explore the diagnostic values of a novel intraoperative handheld endomicroscopy DiveScope (DS) for ex vivo glioma diagnosis and in vivo roving scan for navigation-confirmed glioma negative margin and evaluate its safety. Materials and methods: This prospective pilot study was conducted at Huashan Hospital, Fudan University from October 2021 to October 2023, and enrolled patients scheduled for glioma resection surgery. The diagnostic values of DS scanning were compared with the frozen sections (FS). Hematoxylin–eosin (HE) staining was used as the gold standard for evaluation. The medical device adverse events (MDAE) were recorded for safety analysis. Results: The previous 24 patients with 73 intraoperative isolated samples were included in the DS ex vivo assessments for glioma diagnosis, and the subsequent 40 patients with 52 samples were included in the DS in vivo assessments for navigation-confirmed tumor negative margin. The sensitivity, specificity, and accuracy of DS scanning were 100.0%, 81.6%, and 90.4% for ex vivo assessment by a pathologist, 100.0%, 76.3%, and 87.7% for ex vivo assessment by a neurosurgeon, and 100.0%, 85.0%, and 94.2% for in vivo assessment, respectively. DS in vivo roving scan showed a significantly improved area under the receiver-operating characteristic curve (AUC) compared to FS in assessing the navigation-confirmed tumor negative margin (AUC: 0.925 vs. 0.725, P = 0.003). There were no MDAEs. Time taken for DS scanning for each sample was 75.77 ± 45.03 s and for each patient was 121.63 ± 94.04 s. Conclusion: DiveScope could provide safe, time-effective, and accurate roving histological imaging for navigation-confirmed glioma negative margin during surgery, which may guide the glioma resection process to achieve maximum safe resection and promote prognosis.
- 7 February 2025
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 111 (4) , 2838-2848
Open AccessRoving histological imaging for navigation-confirmed glioma negative margin by handheld endomicroscopy: a parallel controlled study
Introduction: Roving histopathological imaging in navigation-confirmed tumor negative margin has not been achieved during neurosurgery procedures. This study aims to explore the diagnostic values of a novel intraoperative handheld endomicroscopy DiveScope (DS) for ex vivo glioma diagnosis and in vivo roving scan for navigation-confirmed glioma negative margin and evaluate its safety. Materials and methods: This prospective pilot study was conducted at Huashan Hospital, Fudan University from October 2021 to October 2023, and enrolled patients scheduled for glioma resection surgery. The diagnostic values of DS scanning were compared with the frozen sections (FS). Hematoxylin–eosin (HE) staining was used as the gold standard for evaluation. The medical device adverse events (MDAE) were recorded for safety analysis. Results: The previous 24 patients with 73 intraoperative isolated samples were included in the DS ex vivo assessments for glioma diagnosis, and the subsequent 40 patients with 52 samples were included in the DS in vivo assessments for navigation-confirmed tumor negative margin. The sensitivity, specificity, and accuracy of DS scanning were 100.0%, 81.6%, and 90.4% for ex vivo assessment by a pathologist, 100.0%, 76.3%, and 87.7% for ex vivo assessment by a neurosurgeon, and 100.0%, 85.0%, and 94.2% for in vivo assessment, respectively. DS in vivo roving scan showed a significantly improved area under the receiver-operating characteristic curve (AUC) compared to FS in assessing the navigation-confirmed tumor negative margin (AUC: 0.925 vs. 0.725, P = 0.003). There were no MDAEs. Time taken for DS scanning for each sample was 75.77 ± 45.03 s and for each patient was 121.63 ± 94.04 s. Conclusion: DiveScope could provide safe, time-effective, and accurate roving histological imaging for navigation-confirmed glioma negative margin during surgery, which may guide the glioma resection process to achieve maximum safe resection and promote prognosis.
- Open Access
- 7 December 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-14
Holistic bursting cells store long-term memory in auditory cortex
The sensory neocortex has been suggested to be a substrate for long-term memory storage, yet which exact single cells could be specific candidates underlying such long-term memory storage remained neither known nor visible for over a century. Here, using a combination of day-by-day two-photon Ca2+ imaging and targeted single-cell loose-patch recording in an auditory associative learning paradigm with composite sounds in male mice, we reveal sparsely distributed neurons in layer 2/3 of auditory cortex emerged step-wise from quiescence into bursting mode, which then invariably expressed holistic information of the learned composite sounds, referred to as holistic bursting (HB) cells. Notably, it was not shuffled populations but the same sparse HB cells that embodied the behavioral relevance of the learned composite sounds, pinpointing HB cells as physiologically-defined single-cell candidates of an engram underlying long-term memory storage in auditory cortex.
- 7 December 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-14
Open AccessHolistic bursting cells store long-term memory in auditory cortex
The sensory neocortex has been suggested to be a substrate for long-term memory storage, yet which exact single cells could be specific candidates underlying such long-term memory storage remained neither known nor visible for over a century. Here, using a combination of day-by-day two-photon Ca2+ imaging and targeted single-cell loose-patch recording in an auditory associative learning paradigm with composite sounds in male mice, we reveal sparsely distributed neurons in layer 2/3 of auditory cortex emerged step-wise from quiescence into bursting mode, which then invariably expressed holistic information of the learned composite sounds, referred to as holistic bursting (HB) cells. Notably, it was not shuffled populations but the same sparse HB cells that embodied the behavioral relevance of the learned composite sounds, pinpointing HB cells as physiologically-defined single-cell candidates of an engram underlying long-term memory storage in auditory cortex.
- Open Access
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 10 (02) , 025006-16
Ten-kilohertz two-photon microscopy imaging of single-cell dendritic activity and hemodynamics in vivo
SignificanceThe studying of rapid neuronal signaling across large spatial scales in intact, living brains requires both high temporal resolution and versatility of the measurement device.AimWe introduce a high-speed two-photon microscope based on a custom-built acousto-optic deflector (AOD). This microscope has a maximum line scan frequency of 400 kHz and a maximum frame rate of 10,000 frames per second (fps) at 250 × 40 pixels. For stepwise magnification from population view to subcellular view with high spatial and temporal resolution, we combined the AOD with resonance-galvo (RS) scanning.ApproachWith this combinatorial device that supports both large-view navigation and small-view high-speed imaging, we measured dendritic calcium propagation velocity and the velocity of single red blood cells (RBCs).ResultsWe measured dendritic calcium propagation velocity (80 / 62.5 − 116.7 μm / ms) in OGB-1-labeled single cortical neurons in mice in vivo. To benchmark the spatial precision and detection sensitivity of measurement in vivo, we also visualized the trajectories of single RBCs and found that their movement speed follows Poiseuille’s law of laminar flow.ConclusionsThis proof-of-concept methodological development shows that the combination of AOD and RS scanning two-photon microscopy provides both versatility and precision for quantitative analysis of single neuronal activities and hemodynamics in vivo.
- 1 April 2023
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 10 (02) , 025006-16
Open AccessTen-kilohertz two-photon microscopy imaging of single-cell dendritic activity and hemodynamics in vivo
SignificanceThe studying of rapid neuronal signaling across large spatial scales in intact, living brains requires both high temporal resolution and versatility of the measurement device.AimWe introduce a high-speed two-photon microscope based on a custom-built acousto-optic deflector (AOD). This microscope has a maximum line scan frequency of 400 kHz and a maximum frame rate of 10,000 frames per second (fps) at 250 × 40 pixels. For stepwise magnification from population view to subcellular view with high spatial and temporal resolution, we combined the AOD with resonance-galvo (RS) scanning.ApproachWith this combinatorial device that supports both large-view navigation and small-view high-speed imaging, we measured dendritic calcium propagation velocity and the velocity of single red blood cells (RBCs).ResultsWe measured dendritic calcium propagation velocity (80 / 62.5 − 116.7 μm / ms) in OGB-1-labeled single cortical neurons in mice in vivo. To benchmark the spatial precision and detection sensitivity of measurement in vivo, we also visualized the trajectories of single RBCs and found that their movement speed follows Poiseuille’s law of laminar flow.ConclusionsThis proof-of-concept methodological development shows that the combination of AOD and RS scanning two-photon microscopy provides both versatility and precision for quantitative analysis of single neuronal activities and hemodynamics in vivo.
- Open Access
MATRIEX Imaging: Multi-Area Two-photon Real-time In-vivo Explorer
Two-photon laser scanning microscopy, originally developed since 1990s 1 , has been widely applied for biomedical research in recent decades, particularly popular among neuroscientists for studying neural functions in vivo 2 . However, it is typically restricted to one imaging area that is orthogonal to the optical axis. Here, we demonstrate a novel multi-axis optical conjugation method that enables two-photon imaging at single-cell resolution simultaneously in multiple areas at different depths, each of which could have a view diameter of ~200 μm and could be largely freely targeted within a zone up to 12-mm diameter. For example, we show simultaneous imaging of neuronal activities in the primary visual cortex (V1), the primary motor cortex (M1) and the hippocampal CA1 region of awake mice. This method can be readily implemented on a single conventional two-photon microscope to enable multi-area exploration of neuronal activities in vivo .
Open AccessMATRIEX Imaging: Multi-Area Two-photon Real-time In-vivo Explorer
Two-photon laser scanning microscopy, originally developed since 1990s 1 , has been widely applied for biomedical research in recent decades, particularly popular among neuroscientists for studying neural functions in vivo 2 . However, it is typically restricted to one imaging area that is orthogonal to the optical axis. Here, we demonstrate a novel multi-axis optical conjugation method that enables two-photon imaging at single-cell resolution simultaneously in multiple areas at different depths, each of which could have a view diameter of ~200 μm and could be largely freely targeted within a zone up to 12-mm diameter. For example, we show simultaneous imaging of neuronal activities in the primary visual cortex (V1), the primary motor cortex (M1) and the hippocampal CA1 region of awake mice. This method can be readily implemented on a single conventional two-photon microscope to enable multi-area exploration of neuronal activities in vivo .