GMGeorgios A. Mouzeviris

Georgios A. Mouzeviris

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Georgios A. Mouzeviris has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • K T Papakostas

    Mechanical Engineering Department, School of Engineering, Aristotle University of Thessaloniki, EL 54124, Thessaloniki, Greece

    1 shared publication
  • Konstantinos T. Papakostas

    Faculty of Engineering, School of Mechanical Engineering, Aristotle University of Thessaloniki, Thessaloniki, Greece

    1 shared publication
  • Konstantinos T. Papakostas

    Process Equipment Design Laboratory, School of Mechanical Engineering, Faculty of Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece

    1 shared publication

Latest Publications

  • Open Access

    Study on Air-to-Water Heat Pumps Seasonal Performances for Heating in Greece

    by Georgios A. Mouzeviris, Konstantinos T. Papakostas

    Air-to-water heat pumps (AWHPs) is a very good option for efficient heating in the residential and commercial building sectors. Their performance and therefore the use of primary energy and CO2 gas emissions are affected by various factors. The aim of this paper is to present a study on the seasonal coefficient of performance in heating (SCOP) of AWHPs, which are available in the Greek market. The sample consists of 100 models in total, offered by 12 manufacturers, in a range of heat pump’s thermal capacity up to 50 kW. The calculation of SCOP values was performed according to the methodology proposed by the EN14825 standard. The results indicate how the heating capacity, the local climate, the supply water temperature, the compressor’s technology, and the control system affect the seasonal performance of the various AWHP models examined. Setting the SCOP ≥ 3 value as a criterion, the analysis that was carried out in four climatic zones A, B, C, and D of Greece, shows that there are many models that meet this criterion, and, in fact, their number increases from the coldest to warmer climates, in combination with lower water supply temperatures to the heating system and a control system with weather compensation.


  • Open Access

    Air-to-water heat pumps: the impact of climate, compressor technology, water output temperature and sizing on the seasonal coefficient of performance for heating

    by G A Mouzeviris, K T Papakostas

    Air-to-water heat pumps (AWHPs) are devices that will broadly replace heating systems based on fossil fuels. The performance of AWHPs in heating operation is strongly influenced by various parameters such as the climate of the location, the hot water output temperature to the heat emitters, the oversizing or downsizing of the HP with respect to the thermal load of the building, the control system, and the heat pump’s compressor technology (fixed-capacity and inverter-driven HPs). The aim of this work is to study the impact of those parameters on the seasonal efficiency for heating of AWHPs in buildings at representative cities of the four Greek climatic zones. The active mode seasonal coefficient of performance (SCOPon) was estimated in various case studies, with the method proposed in European standard EN 14825, by using climatic data of the four locations. The results show the positive effect of lowering the water supply temperature to the heating system and of using inverter technology and control system with compensation on AWHPs efficiency. Additionally, it is demonstrated that the optimal performance of inverter-driven HPs appears when they are sized at the design outdoor air temperature, while in the case of the fixed-capacity HPs when they are down-sized.


  • Comparative analysis of air-to-water and ground source heat pumps performances

    by Georgios A. Mouzeviris, Konstantinos T. Papakostas

    A comparative analysis of the Coefficient of Performance (COP) and the Energy Efficiency Ratio (EER), based on the technical data of 430 different models of air-to-water heat pumps (AWHPs) as well ground-source heat pumps (GSHPs), at certain conditions of ambient air, ground source and water outlet from the heat pump (HP) temperatures, is performed. The results, presented in graphical and tabular form, give the COP and EER values against the HPs nominal capacity and the correlation between COP and EER with the temperature rise ΔΤ along the HP. By averaging the performance values of all AWHPs or GSHPs models, equations of polynomial regression that give the relationship between average COP or EER and ΔΤ values were also calculated. It is shown that inverter-driven HPs generally have higher COP and EER as compared to the fix-capacity HPs, for the same heating or cooling range. Also, performance is highly depended on ΔΤ.