Cristiano Cabral Muller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cristiano Cabral Muller has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Edson Irineu Muller
Programa de Pós-Graduação em Química, Universidade Federal de Santa Maria—UFSM, Santa Maria 97105-900, Brazil
7 shared publications - Erico Marlon Moraes Flores
Departamento de Química, Universidade Federal de Santa Maria, Santa Maria, RS, 97105-900, Brazil
4 shared publications Aline L.H. Muller
3 shared publications- Paola Azevedo Mello
Departamento de Química, Universidade Federal de Santa Maria, Santa Maria, RS, 97105-900, Brazil
3 shared publications Aline L. H. Muller
2 shared publications- Juliana Pinheiro de Souza
Instituto de Química, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 July 2023
- Published by Revista JRG de Estudos Academicos in Revista JRG de Estudos Acadêmicos
- Vol. 6 (13) , 1943-1956
Desenvolvimento e validação de metodologia analítica para quantificação de sódio e cálcio em carbonato de lítio empregando a técnica de ICP OES com amostragem automatizada
O processo de validação de metodologias analíticas em laboratórios de pesquisa é essencial para obter a aprovação da ANVISA e, consequentemente, o registro e a comercialização de medicamentos, sejam eles de referência ou genéricos. Isso envolve a realização de testes específicos em Insumos Farmacêuticos Ativos (IFAs), que devem atender às especificações em farmacopeias e/ou compêndios reconhecidos ou, se necessário, métodos validados que sejam realizados e comprovados sua eficiência. Neste contexto, o trabalho visa validar uma metodologia analítica para quantificar Cálcio e Sódio na matéria prima Carbonato de Lítio, utilizando a técnica de ICP-OES com avaliação de diversos parâmetros, incluindo seletividade, linearidade, limite de quantificação, precisão (repetibilidade e intermediária), exatidão, faixa de trabalho e robustez. O objetivo é garantir que o método atenda aos requisitos da legislação em vigor. Para realizar as análises, as amostras foram preparadas dissolvendo-as em uma solução de ácido clorídrico 5 mol L-1. Os resultados demonstraram que o método analítico é capaz de identificar e quantificar os analitos de interesse sem interferências espectrais, mantendo uma relação direta entre a concentração e a resposta analítica, além de apresentar conclusões e exatidão sob as condições experimentais condicionais.
- 1 July 2023
- Published by Revista JRG de Estudos Academicos in Revista JRG de Estudos Acadêmicos
- Vol. 6 (13) , 1943-1956
Open AccessDesenvolvimento e validação de metodologia analítica para quantificação de sódio e cálcio em carbonato de lítio empregando a técnica de ICP OES com amostragem automatizada
O processo de validação de metodologias analíticas em laboratórios de pesquisa é essencial para obter a aprovação da ANVISA e, consequentemente, o registro e a comercialização de medicamentos, sejam eles de referência ou genéricos. Isso envolve a realização de testes específicos em Insumos Farmacêuticos Ativos (IFAs), que devem atender às especificações em farmacopeias e/ou compêndios reconhecidos ou, se necessário, métodos validados que sejam realizados e comprovados sua eficiência. Neste contexto, o trabalho visa validar uma metodologia analítica para quantificar Cálcio e Sódio na matéria prima Carbonato de Lítio, utilizando a técnica de ICP-OES com avaliação de diversos parâmetros, incluindo seletividade, linearidade, limite de quantificação, precisão (repetibilidade e intermediária), exatidão, faixa de trabalho e robustez. O objetivo é garantir que o método atenda aos requisitos da legislação em vigor. Para realizar as análises, as amostras foram preparadas dissolvendo-as em uma solução de ácido clorídrico 5 mol L-1. Os resultados demonstraram que o método analítico é capaz de identificar e quantificar os analitos de interesse sem interferências espectrais, mantendo uma relação direta entre a concentração e a resposta analítica, além de apresentar conclusões e exatidão sob as condições experimentais condicionais.
- 28 July 2020
- Published by Springer Nature
- p. 165-198
Chemistry of Ionic Liquid, Switchable Solvents, Supercritical Carbon Dioxide and Sub/Supercritical Water
- 28 July 2020
- Published by Springer Nature
- p. 165-198
Chemistry of Ionic Liquid, Switchable Solvents, Supercritical Carbon Dioxide and Sub/Supercritical Water
- 26 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (5) , 2129-2134
Determination of chlorine and sulfur in high purity flexible graphite using ion chromatography (IC) and inductively coupled plasma optical emission spectrometry (ICP OES) after pyrohydrolysis sample preparation
The pyrohydrolysis method was applied for digestion of high purity flexible graphite (FG) used in nuclear applications and subsequent determination of Cl and S was performed by inductively coupled plasma optical emission spectrometry (ICP OES) and ion chromatography (IC). Instrumental parameters for pyrohydrolysis were studied such as reaction time, air and water flow-rates pumped through the reactor, the type and concentration of absorbing solution (water, 10 to 200 mmol L−1 NH4OH or 100 to 1000 mmol L−1 H2O2) and the use of V2O5 as an accelerator. Sample masses up to 250 mg were decomposed using pyrohydrolysis at 1100 °C for 30 min. Quantitative recoveries of Cl and S were obtained using air and water flow-rates pumped through the reactor at 0.1 L min−1 and 0.5 mL min−1, respectively, without the use of V2O5. Absorbing solution of 50 mmol L−1 NH4OH and 250 mmol L−1 H2O2 was suitable for quantitative absorption of Cl and S. The limit of detection (LOD) was 1 μg g−1 for Cl determination by IC that was 20-fold better than that obtained by ICP OES. In this sense, IC determination is recommended for Cl determination in FG in order to meet the General Electric (GE) recommendations for nuclear materials. On the other hand, LODs obtained for S using IC and ICP OES were similar (1 μg g−1). For S determination by IC, the absorbing solution should be H2O2 in order to convert all S species to SO4 2−. For comparison, Cl and S were also determined in digests obtained using microwave-induced combustion (MIC). In spite of high chemical inertness that allowed combustion of only 25 mg of FG, the statistical difference between pyrohydrolysis and MIC results was not observed. Evaluation of accuracy was carried out using certified reference materials (NIST 1632c – bituminous coal and SARM 19 coal) and significant differences were not observed between certified reference values and pyrohydrolysis results. After optimizing conditions, pyrohydrolysis was suitable for quality control of Cl and S impurities in FG used for nuclear applications.
- 26 January 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (5) , 2129-2134
Determination of chlorine and sulfur in high purity flexible graphite using ion chromatography (IC) and inductively coupled plasma optical emission spectrometry (ICP OES) after pyrohydrolysis sample preparation
The pyrohydrolysis method was applied for digestion of high purity flexible graphite (FG) used in nuclear applications and subsequent determination of Cl and S was performed by inductively coupled plasma optical emission spectrometry (ICP OES) and ion chromatography (IC). Instrumental parameters for pyrohydrolysis were studied such as reaction time, air and water flow-rates pumped through the reactor, the type and concentration of absorbing solution (water, 10 to 200 mmol L−1 NH4OH or 100 to 1000 mmol L−1 H2O2) and the use of V2O5 as an accelerator. Sample masses up to 250 mg were decomposed using pyrohydrolysis at 1100 °C for 30 min. Quantitative recoveries of Cl and S were obtained using air and water flow-rates pumped through the reactor at 0.1 L min−1 and 0.5 mL min−1, respectively, without the use of V2O5. Absorbing solution of 50 mmol L−1 NH4OH and 250 mmol L−1 H2O2 was suitable for quantitative absorption of Cl and S. The limit of detection (LOD) was 1 μg g−1 for Cl determination by IC that was 20-fold better than that obtained by ICP OES. In this sense, IC determination is recommended for Cl determination in FG in order to meet the General Electric (GE) recommendations for nuclear materials. On the other hand, LODs obtained for S using IC and ICP OES were similar (1 μg g−1). For S determination by IC, the absorbing solution should be H2O2 in order to convert all S species to SO4 2−. For comparison, Cl and S were also determined in digests obtained using microwave-induced combustion (MIC). In spite of high chemical inertness that allowed combustion of only 25 mg of FG, the statistical difference between pyrohydrolysis and MIC results was not observed. Evaluation of accuracy was carried out using certified reference materials (NIST 1632c – bituminous coal and SARM 19 coal) and significant differences were not observed between certified reference values and pyrohydrolysis results. After optimizing conditions, pyrohydrolysis was suitable for quality control of Cl and S impurities in FG used for nuclear applications.
- 1 September 2014
- Published by Elsevier in Microchemical Journal
- Vol. 116, 255-260
Feasibility of nut digestion using single reaction chamber for further trace element determination by ICP-OES
- 1 September 2014
- Published by Elsevier in Microchemical Journal
- Vol. 116, 255-260
Feasibility of nut digestion using single reaction chamber for further trace element determination by ICP-OES
- 9 May 2012
- Published by Springer Nature in Food Analytical Methods
- Vol. 6 (1) , 258-264
Determination of Toxic Elements in Nuts by Inductively Coupled Plasma Mass Spectrometry after Microwave-Induced Combustion
- 9 May 2012
- Published by Springer Nature in Food Analytical Methods
- Vol. 6 (1) , 258-264
Determination of Toxic Elements in Nuts by Inductively Coupled Plasma Mass Spectrometry after Microwave-Induced Combustion
- 19 March 2012
- Published by Taylor & Francis in Analytical Letters
- Vol. 45 (9) , 1004-1015
Determination of Bromide, Chloride, and Fluoride in Cigarette Tobacco by Ion Chromatography after Microwave-Induced Combustion
A microwave-induced combustion (MIC) method was applied for cigarette tobacco digestion and further determination of bromide (Br), chloride (Cl), and fluoride (F) by ion chromatography (IC). Samples (up to 500 mg) were combusted at 20 bar of oxygen. Combustion was complete in less than 30 s, and analytes were absorbed in (NH4)2CO3 solutions. A reflux step, not available in other systems, was applied to improve analyte absorption. Absorbing solution with 50 mmol L−1(NH4)2CO3 was selected because it showed recovery close to 100% for samples containing spikes of halogens. Accuracy of the proposed procedure was evaluated by analysis of certified reference materials and the agreement was better than 97% for all analytes using 50 mmol L−1 (NH4)2CO3 as absorbing solution and 5 min of reflux. Temperature during combustion was higher than 1400°C and the residual carbon content was always lower than 1%. With the use of the MIC system, up to eight samples could be processed simultaneously, and a single absorbing solution was suitable for all analytes. Limits of quantification by MIC and further IC determination were 0.50, 0.20, and 0.10 µg g−1 for Br, Cl, and F, respectively.
- 19 March 2012
- Published by Taylor & Francis in Analytical Letters
- Vol. 45 (9) , 1004-1015
Determination of Bromide, Chloride, and Fluoride in Cigarette Tobacco by Ion Chromatography after Microwave-Induced Combustion
A microwave-induced combustion (MIC) method was applied for cigarette tobacco digestion and further determination of bromide (Br), chloride (Cl), and fluoride (F) by ion chromatography (IC). Samples (up to 500 mg) were combusted at 20 bar of oxygen. Combustion was complete in less than 30 s, and analytes were absorbed in (NH4)2CO3 solutions. A reflux step, not available in other systems, was applied to improve analyte absorption. Absorbing solution with 50 mmol L−1(NH4)2CO3 was selected because it showed recovery close to 100% for samples containing spikes of halogens. Accuracy of the proposed procedure was evaluated by analysis of certified reference materials and the agreement was better than 97% for all analytes using 50 mmol L−1 (NH4)2CO3 as absorbing solution and 5 min of reflux. Temperature during combustion was higher than 1400°C and the residual carbon content was always lower than 1%. With the use of the MIC system, up to eight samples could be processed simultaneously, and a single absorbing solution was suitable for all analytes. Limits of quantification by MIC and further IC determination were 0.50, 0.20, and 0.10 µg g−1 for Br, Cl, and F, respectively.