Chitaranjan Phurailatpam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chitaranjan Phurailatpam has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Zakir Hussain Rather
Indian Institute of Technology Bombay
4 shared publications - Behrooz Bahrani
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
3 shared publications - Suryanarayana Doolla
Department of Energy Science and Engineering, IIT Bombay, Mumbai, Maharashtra, India
3 shared publications - Bharat Singh Rajpurohit
Department of Electrical Engineering, Indian Institute of Technology, Jodhpur, India
1 shared publication - Dayan Bandara Rathnayake
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
1 shared publication - Dhiraj Khadka
IIT Bombay
1 shared publication
Latest Publications
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Estimation of Minimum Inertia and Fast Frequency Support for Renewable Energy Dominated Power Systems
Displacement of conventional generations with the rapid adoption of renewable energy (RE) sources has led to diminishing system inertia and active power reserves. Consequently, power systems with high shares of RE sources have become more susceptible to frequency stability issues, often experiencing higher rate of change of frequency (RoCoF) and frequency deviations. Accurate estimation of essential system services required to maintain a stable and economic operation has become crucial. This paper proposes a new method for the accurate estimation of minimum synchronous inertia and frequency containment reserve (FCR) response to ensure compliance with system-specified RoCoF and frequency deviation limits. Firstly, the minimum synchronous inertia requirement for a specified RoCoF limit is calculated, which also considers the instantaneous response from demand, Type-I and Type-II wind generators, that are generally difficult to monitor. The overall FCR requirement is then estimated to maintain the frequency deviation within the pre-defined limits. Dynamic FCR response includes fast frequency response (FFR) from inverter-based resources (IBR), responses from load and governors from conventional generations. Finally, the share of FFR contribution coming from IBRs, representing the system service requirement, is segregated from the overall FCR and estimated accurately. With the proposed method, system operators can be best informed of the exact minimum inertia and FFR requirement to ensure frequency stability. The proposed methodology is tested and validated in a modified IEEE 39-bus system and an actual grid model of the Gujarat State in India.
- 3 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-14
Estimation of Minimum Inertia and Fast Frequency Support for Renewable Energy Dominated Power Systems
Displacement of conventional generations with the rapid adoption of renewable energy (RE) sources has led to diminishing system inertia and active power reserves. Consequently, power systems with high shares of RE sources have become more susceptible to frequency stability issues, often experiencing higher rate of change of frequency (RoCoF) and frequency deviations. Accurate estimation of essential system services required to maintain a stable and economic operation has become crucial. This paper proposes a new method for the accurate estimation of minimum synchronous inertia and frequency containment reserve (FCR) response to ensure compliance with system-specified RoCoF and frequency deviation limits. Firstly, the minimum synchronous inertia requirement for a specified RoCoF limit is calculated, which also considers the instantaneous response from demand, Type-I and Type-II wind generators, that are generally difficult to monitor. The overall FCR requirement is then estimated to maintain the frequency deviation within the pre-defined limits. Dynamic FCR response includes fast frequency response (FFR) from inverter-based resources (IBR), responses from load and governors from conventional generations. Finally, the share of FFR contribution coming from IBRs, representing the system service requirement, is segregated from the overall FCR and estimated accurately. With the proposed method, system operators can be best informed of the exact minimum inertia and FFR requirement to ensure frequency stability. The proposed methodology is tested and validated in a modified IEEE 39-bus system and an actual grid model of the Gujarat State in India.
- Top Cited PapersOpen Access
- 13 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 114781-114807
Grid Forming Inverter Modeling, Control, and Applications
This paper surveys current literature on modeling methods, control techniques, protection schemes, applications, and real-world implementations pertaining to grid forming inverters (GFMIs). Electric power systems are increasingly being augmented with inverter-based resources (IBRs). While having a growing share of IBRs, conventional synchronous generator-based voltage and frequency control mechanisms are still prevalent in the power industry. Therefore, IBRs are experiencing a growing demand for mimicking the behavior of synchronous generators, which is not possible with conventional grid following inverters (GFLIs). As a solution, the concept of GFMIs is currently emerging, which is drawing increased attention from academia and the industry. This paper presents a comprehensive review of GFMIs covering recent advancements in control technologies, fault ride-through capabilities, stability enhancement measures, and practical implementations. Moreover, the challenges in adding GFMIs into existing power systems, including a seamless transition from grid-connected mode to the standalone mode and vice versa, are also discussed in detail. Recently commissioned projects in Australia, the UK, and the US are taken as examples to highlight the trend in the power industry in adding GFMIs to address issues related to weak grid scenarios. Research directions in terms of voltage control, frequency control, system strength improvement, and regulatory framework are also discussed. This paper serves as a resource for researchers and power system engineers exploring solutions to the emerging problems with high penetration of IBRs, focusing on GFMIs.
- 13 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 114781-114807
Top Cited PapersOpen AccessGrid Forming Inverter Modeling, Control, and Applications
This paper surveys current literature on modeling methods, control techniques, protection schemes, applications, and real-world implementations pertaining to grid forming inverters (GFMIs). Electric power systems are increasingly being augmented with inverter-based resources (IBRs). While having a growing share of IBRs, conventional synchronous generator-based voltage and frequency control mechanisms are still prevalent in the power industry. Therefore, IBRs are experiencing a growing demand for mimicking the behavior of synchronous generators, which is not possible with conventional grid following inverters (GFLIs). As a solution, the concept of GFMIs is currently emerging, which is drawing increased attention from academia and the industry. This paper presents a comprehensive review of GFMIs covering recent advancements in control technologies, fault ride-through capabilities, stability enhancement measures, and practical implementations. Moreover, the challenges in adding GFMIs into existing power systems, including a seamless transition from grid-connected mode to the standalone mode and vice versa, are also discussed in detail. Recently commissioned projects in Australia, the UK, and the US are taken as examples to highlight the trend in the power industry in adding GFMIs to address issues related to weak grid scenarios. Research directions in terms of voltage control, frequency control, system strength improvement, and regulatory framework are also discussed. This paper serves as a resource for researchers and power system engineers exploring solutions to the emerging problems with high penetration of IBRs, focusing on GFMIs.
- 2 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 1903-1914
Estimation of Non-Synchronous Inertia in AC Microgrids
This paper proposes a comprehensive method to estimate non-synchronous inertia in an AC microgrid system by analyzing measured frequency transients. Non-synchronous inertia includes inertial support from various inverter-interfaced renewable energy sources and energy storage devices in the form of virtual or emulated inertia. In the proposed method, a multi-step approach is used to identify a matrix of parameters that estimates the overall non-synchronous inertial response. Firstly, motivations are drawn from the fundamental system requirements of adequacy in RoCoF and maximum deviation in frequency, for any credible contingency. A systematic classification of various contributors to the non-synchronous inertial response is also carried out. System-identification studies are then performed to identify various component-models that contribute to the non-synchronous inertia. The component models include a faster RoCoF-based response model, a relatively slower frequency deviation based model, and in some cases, a slow, integral-of-frequency based model. Lastly, the concept of releasable kinetic energy and non-linear estimation is used to identify the capability of the virtual inertia sources and improve the accuracy of the overall estimate. The developed methodology is tested in a microgrid network hosting a mix of renewable energy generations and battery energy storage systems. The estimate of non-synchronous inertia will help system operators to accurately estimate the maximum frequency deviation and the time to reach the maximum deviation for any credible contingency. The estimate can also help in deciding the type of virtual inertia that will best maintain frequency stability in the microgrid system.
- 2 April 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 1903-1914
Estimation of Non-Synchronous Inertia in AC Microgrids
This paper proposes a comprehensive method to estimate non-synchronous inertia in an AC microgrid system by analyzing measured frequency transients. Non-synchronous inertia includes inertial support from various inverter-interfaced renewable energy sources and energy storage devices in the form of virtual or emulated inertia. In the proposed method, a multi-step approach is used to identify a matrix of parameters that estimates the overall non-synchronous inertial response. Firstly, motivations are drawn from the fundamental system requirements of adequacy in RoCoF and maximum deviation in frequency, for any credible contingency. A systematic classification of various contributors to the non-synchronous inertial response is also carried out. System-identification studies are then performed to identify various component-models that contribute to the non-synchronous inertia. The component models include a faster RoCoF-based response model, a relatively slower frequency deviation based model, and in some cases, a slow, integral-of-frequency based model. Lastly, the concept of releasable kinetic energy and non-linear estimation is used to identify the capability of the virtual inertia sources and improve the accuracy of the overall estimate. The developed methodology is tested in a microgrid network hosting a mix of renewable energy generations and battery energy storage systems. The estimate of non-synchronous inertia will help system operators to accurately estimate the maximum frequency deviation and the time to reach the maximum deviation for any credible contingency. The estimate can also help in deciding the type of virtual inertia that will best maintain frequency stability in the microgrid system.
- 18 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1975-1984
Measurement-Based Estimation of Inertia in AC Microgrids
- 18 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1975-1984
Measurement-Based Estimation of Inertia in AC Microgrids
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3610-3613
Optimization of DC microgrid for rural applications in India
This paper presents planning and optimization of DC microgrid for rural applications in India. Load profile of a village in Chhattisgarh state of India is considered for the study. Hourly data of solar irradiation & wind speeds and prices of the various components of the microgrid are also obtained. Using these data, a model of DC microgrid is constructed in Homer Energy™ software. Simulations are then carried out to determine the optimal system configuration which has the lowest life cycle cost for autonomous operation. A special case study for with a partial connectivity to the grid is also conducted. The study also gives a detailed analysis of the various cost components, energy productions, power management and emissions.
- 9 February 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3610-3613
Optimization of DC microgrid for rural applications in India
This paper presents planning and optimization of DC microgrid for rural applications in India. Load profile of a village in Chhattisgarh state of India is considered for the study. Hourly data of solar irradiation & wind speeds and prices of the various components of the microgrid are also obtained. Using these data, a model of DC microgrid is constructed in Homer Energy™ software. Simulations are then carried out to determine the optimal system configuration which has the lowest life cycle cost for autonomous operation. A special case study for with a partial connectivity to the grid is also conducted. The study also gives a detailed analysis of the various cost components, energy productions, power management and emissions.