Dayan Bandara Rathnayake
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dayan Bandara Rathnayake has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Behrooz Bahrani
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
7 shared publications - Reza Razzaghi
Department of Electrical and Computer Systems Engineering, Monash University, Clayton, VIC, Australia
3 shared publications - Sajjad Hadavi
Windlab Pty Ltd., Melbourne, VIC, Australia
2 shared publications - Shantha D. Gamini Jayasinghe
Australian Maritime College, University of Tasmania, Launceston 7250, Australia
2 shared publications - Si Phu Me
Monash University
2 shared publications - Ali Mehrizi-Sani
Virginia Tech, Blacksburg, VA, USA
1 shared publication
Latest Publications
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1554-1565
Impact of Voltage-Loop Feedforward Terms on the Stability of Grid-Forming Inverters and Remedial Actions
This paper reveals the impact of voltage control loop feedforward terms on the stability of grid-forming inverters (GFMIs) connected to a grid. By deriving a mathematical model, this paper shows that unless the GFMI current control loop is fast enough, the feedforward terms in the voltage control loop may threaten the GFMI small-signal stability. To this end, a necessary and sufficient condition for GFMI stability is proposed, provided that the grid impedance at the point of connection is known. Furthermore, two easy-to-implement yet effective remedial actions are proposed to enhance stability. Aiming to preserve the control structure, the first remedial action re-tunes the voltage controller to satisfy the obtained stability condition, while the second remedial action incorporates simple gains to attenuate the feedforward terms. Moreover, to demonstrate the effectiveness of the second remedial action, the obtained necessary and sufficient stability condition is modified to include the proposed attenuation gain. Eventually, the accuracy of the stability analysis and the effectiveness of the proposed remedial actions are evaluated in simulation and experiment.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 1554-1565
Impact of Voltage-Loop Feedforward Terms on the Stability of Grid-Forming Inverters and Remedial Actions
This paper reveals the impact of voltage control loop feedforward terms on the stability of grid-forming inverters (GFMIs) connected to a grid. By deriving a mathematical model, this paper shows that unless the GFMI current control loop is fast enough, the feedforward terms in the voltage control loop may threaten the GFMI small-signal stability. To this end, a necessary and sufficient condition for GFMI stability is proposed, provided that the grid impedance at the point of connection is known. Furthermore, two easy-to-implement yet effective remedial actions are proposed to enhance stability. Aiming to preserve the control structure, the first remedial action re-tunes the voltage controller to satisfy the obtained stability condition, while the second remedial action incorporates simple gains to attenuate the feedforward terms. Moreover, to demonstrate the effectiveness of the second remedial action, the obtained necessary and sufficient stability condition is modified to include the proposed attenuation gain. Eventually, the accuracy of the stability analysis and the effectiveness of the proposed remedial actions are evaluated in simulation and experiment.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (2) , 2311-2325
H∞-Based Control Design for Grid-Forming Inverters With Enhanced Damping and Virtual Inertia
Grid-forming inverters (GFMIs) are identified as an important asset for achieving renewable energy-rich power grids. GFMIs are attracting significant attention due to their superior characteristics over grid-following inverters in both grid-connected (GC) and standalone (SA) scenarios. In this paper, a second-order discrete-time controller is proposed to achieve a well-damped step response for power reference commands and improved virtual inertia provision capability. In this paper, a control design method based on H∞ is proposed, which is based on the frequency response of the system, to tune the proposed controller. The proposed control design presents a methodical process to specify the desired performance indices through frequency-domain constraints. The performance of the controller is thoroughly validated analytically and through simulation results. The superior performance of the proposed controller over the virtual synchronous generator controller in terms of tracking performance and virtual inertia provision capability is verified through experimental results.
- 14 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (2) , 2311-2325
H∞-Based Control Design for Grid-Forming Inverters With Enhanced Damping and Virtual Inertia
Grid-forming inverters (GFMIs) are identified as an important asset for achieving renewable energy-rich power grids. GFMIs are attracting significant attention due to their superior characteristics over grid-following inverters in both grid-connected (GC) and standalone (SA) scenarios. In this paper, a second-order discrete-time controller is proposed to achieve a well-damped step response for power reference commands and improved virtual inertia provision capability. In this paper, a control design method based on H∞ is proposed, which is based on the frequency response of the system, to tune the proposed controller. The proposed control design presents a methodical process to specify the desired performance indices through frequency-domain constraints. The performance of the controller is thoroughly validated analytically and through simulation results. The superior performance of the proposed controller over the virtual synchronous generator controller in terms of tracking performance and virtual inertia provision capability is verified through experimental results.
- 11 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (2) , 1635-1649
Multivariable Control Design for Grid-Forming Inverters With Decoupled Active and Reactive Power Loops
Grid-forming inverters (GFMIs) are recognized as a prominent driver toward achieving renewable energy-rich power grids. Unlike grid-following inverters (GFLIs), which are controlled as current sources, GFMIs are controlled as voltage sources. In GFMIs, dynamic control of the magnitude ( $V_{\mathrm{c}}$ ) and angle ( $\theta$ ) of the point of common coupling (PCC) voltage is used to achieve active ( $P$ ) and reactive ( $Q$ ) power transfer across a line. However, independent control of $P$ and $Q$ via $V_{\mathrm{c}}$ and $\theta$ becomes challenging due to the coupling between $P$ and $Q$ loops. The coupling becomes severe as the resistance-to-reactance ratio of the grid impedance and the power angle between the GFMI and the grid voltages are increased. This article proposes a novel multivariable controller to completely decouple $P$ and $Q$ loops in GFMIs. The proposed multivariable controller could be designed based on the prevalent control structures for GFMIs such as droop controller, swing equation-based virtual synchronous generator (VSG) controller, zero steady-state error reactive power controller, and fixed steady-state error reactive power controller. The additional cross-channel decoupling controllers in the proposed multivariable controller provide superior decoupling action over the existing decoupling methods, such as the virtual inductor-based method. An $\mathcal {H}_\infty$ -based method is adopted to tune the proposed multivariable controller parameters, where the straightforward formulation of the desired closed-loop dynamics based on the open-loop system is clearly shown. The decoupling performance of the controller is experimentally validated extensively. The experimental results show that the proposed controller results in superior performance over the prevalent decoupling methods, such as the virtual-inductor decoupling method.
- 11 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (2) , 1635-1649
Multivariable Control Design for Grid-Forming Inverters With Decoupled Active and Reactive Power Loops
Grid-forming inverters (GFMIs) are recognized as a prominent driver toward achieving renewable energy-rich power grids. Unlike grid-following inverters (GFLIs), which are controlled as current sources, GFMIs are controlled as voltage sources. In GFMIs, dynamic control of the magnitude ( $V_{\mathrm{c}}$ ) and angle ( $\theta$ ) of the point of common coupling (PCC) voltage is used to achieve active ( $P$ ) and reactive ( $Q$ ) power transfer across a line. However, independent control of $P$ and $Q$ via $V_{\mathrm{c}}$ and $\theta$ becomes challenging due to the coupling between $P$ and $Q$ loops. The coupling becomes severe as the resistance-to-reactance ratio of the grid impedance and the power angle between the GFMI and the grid voltages are increased. This article proposes a novel multivariable controller to completely decouple $P$ and $Q$ loops in GFMIs. The proposed multivariable controller could be designed based on the prevalent control structures for GFMIs such as droop controller, swing equation-based virtual synchronous generator (VSG) controller, zero steady-state error reactive power controller, and fixed steady-state error reactive power controller. The additional cross-channel decoupling controllers in the proposed multivariable controller provide superior decoupling action over the existing decoupling methods, such as the virtual inductor-based method. An $\mathcal {H}_\infty$ -based method is adopted to tune the proposed multivariable controller parameters, where the straightforward formulation of the desired closed-loop dynamics based on the open-loop system is clearly shown. The decoupling performance of the controller is experimentally validated extensively. The experimental results show that the proposed controller results in superior performance over the prevalent decoupling methods, such as the virtual-inductor decoupling method.
- Top Cited Papers
- 18 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 13 (2) , 1021-1036
Generalized Virtual Synchronous Generator Control Design for Renewable Power Systems
Grid-forming inverters (GFMIs) are recognized as one of the key enablers towards highly renewable energy proliferated grids. One of the pivotal characteristicsof GFMIs is the ability to seamlessly switch between grid-connected (GC) and standalone (SA) modes. In this paper, a novel controller is proposed to accurately follow the power reference commands in the GC mode while providing the required amount of virtual inertia in the SA mode to slow down the rate of change of frequency (RoCoF) following a disturbance. The proposed control design, where straightforward equations are given to calculate the controller gains directly, is based on the frequency response of the open-loop system. Furthermore, based on the frequency response of the controller, a condition for the placement of the poles of the controller is derived to guarantee the RoCoF relay limit compliance in the SA mode. The experimental results show that the proposed controller results in lower overshoots and shorter settling times in step responses in the GC mode than the virtual synchronous generator (VSG) controller while providing more virtual inertia than the VSG controller to slow down RoCoF in the SA mode. Furthermore, the experimental results illustrate that the proposed controller can also be designed to support the grid during frequency transients. The performance of the controller is extensively validated experimentally during GC to SA mode transition and vice versa, in a multi-inverter network, and in a wide-area model.
- 18 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 13 (2) , 1021-1036
Top Cited PapersGeneralized Virtual Synchronous Generator Control Design for Renewable Power Systems
Grid-forming inverters (GFMIs) are recognized as one of the key enablers towards highly renewable energy proliferated grids. One of the pivotal characteristicsof GFMIs is the ability to seamlessly switch between grid-connected (GC) and standalone (SA) modes. In this paper, a novel controller is proposed to accurately follow the power reference commands in the GC mode while providing the required amount of virtual inertia in the SA mode to slow down the rate of change of frequency (RoCoF) following a disturbance. The proposed control design, where straightforward equations are given to calculate the controller gains directly, is based on the frequency response of the open-loop system. Furthermore, based on the frequency response of the controller, a condition for the placement of the poles of the controller is derived to guarantee the RoCoF relay limit compliance in the SA mode. The experimental results show that the proposed controller results in lower overshoots and shorter settling times in step responses in the GC mode than the virtual synchronous generator (VSG) controller while providing more virtual inertia than the VSG controller to slow down RoCoF in the SA mode. Furthermore, the experimental results illustrate that the proposed controller can also be designed to support the grid during frequency transients. The performance of the controller is extensively validated experimentally during GC to SA mode transition and vice versa, in a multi-inverter network, and in a wide-area model.
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (3) , 1857-1867
A Robust Exciter Controller Design for Synchronous Condensers in Weak Grids
Weak grid scenarios and low-inertia systems are emerging issues in power systems, which could lead to voltage and frequency instabilities. Synchronous Condensers (SynCons) have recently drawn renewed attention as a promising solution to provide system strength and inertia support. Even though the exciter control of SynCons is a well-established technology, further developments are required to guarantee the stability of post-fault operations, in particular, in weak grids. This paper proposes a data-driven approach for designing higher-order optimized exciter controllers to meet this requirement. A pseudo-random binary sequence (PRBS)-based system identification method is used to obtain frequency response data of the power system, from the exciter point of view, which is then fed into the proposed optimal control design procedure. The proposed exciter controller is tested for voltage ride-through and fault scenarios in a single machine infinite bus (SMIB) case and the IEEE 39-bus test system to assess its performance compared to the conventional AC1A exciter controller. The results obtained through simulation tests carried out using the PSCAD/EMTDC software verify that the proposed exciter controller guarantees the post-fault stability in both strong and weak grids.
- 8 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 37 (3) , 1857-1867
A Robust Exciter Controller Design for Synchronous Condensers in Weak Grids
Weak grid scenarios and low-inertia systems are emerging issues in power systems, which could lead to voltage and frequency instabilities. Synchronous Condensers (SynCons) have recently drawn renewed attention as a promising solution to provide system strength and inertia support. Even though the exciter control of SynCons is a well-established technology, further developments are required to guarantee the stability of post-fault operations, in particular, in weak grids. This paper proposes a data-driven approach for designing higher-order optimized exciter controllers to meet this requirement. A pseudo-random binary sequence (PRBS)-based system identification method is used to obtain frequency response data of the power system, from the exciter point of view, which is then fed into the proposed optimal control design procedure. The proposed exciter controller is tested for voltage ride-through and fault scenarios in a single machine infinite bus (SMIB) case and the IEEE 39-bus test system to assess its performance compared to the conventional AC1A exciter controller. The results obtained through simulation tests carried out using the PSCAD/EMTDC software verify that the proposed exciter controller guarantees the post-fault stability in both strong and weak grids.
- Top Cited PapersOpen Access
- 13 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 114781-114807
Grid Forming Inverter Modeling, Control, and Applications
This paper surveys current literature on modeling methods, control techniques, protection schemes, applications, and real-world implementations pertaining to grid forming inverters (GFMIs). Electric power systems are increasingly being augmented with inverter-based resources (IBRs). While having a growing share of IBRs, conventional synchronous generator-based voltage and frequency control mechanisms are still prevalent in the power industry. Therefore, IBRs are experiencing a growing demand for mimicking the behavior of synchronous generators, which is not possible with conventional grid following inverters (GFLIs). As a solution, the concept of GFMIs is currently emerging, which is drawing increased attention from academia and the industry. This paper presents a comprehensive review of GFMIs covering recent advancements in control technologies, fault ride-through capabilities, stability enhancement measures, and practical implementations. Moreover, the challenges in adding GFMIs into existing power systems, including a seamless transition from grid-connected mode to the standalone mode and vice versa, are also discussed in detail. Recently commissioned projects in Australia, the UK, and the US are taken as examples to highlight the trend in the power industry in adding GFMIs to address issues related to weak grid scenarios. Research directions in terms of voltage control, frequency control, system strength improvement, and regulatory framework are also discussed. This paper serves as a resource for researchers and power system engineers exploring solutions to the emerging problems with high penetration of IBRs, focusing on GFMIs.
- 13 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 114781-114807
Top Cited PapersOpen AccessGrid Forming Inverter Modeling, Control, and Applications
This paper surveys current literature on modeling methods, control techniques, protection schemes, applications, and real-world implementations pertaining to grid forming inverters (GFMIs). Electric power systems are increasingly being augmented with inverter-based resources (IBRs). While having a growing share of IBRs, conventional synchronous generator-based voltage and frequency control mechanisms are still prevalent in the power industry. Therefore, IBRs are experiencing a growing demand for mimicking the behavior of synchronous generators, which is not possible with conventional grid following inverters (GFLIs). As a solution, the concept of GFMIs is currently emerging, which is drawing increased attention from academia and the industry. This paper presents a comprehensive review of GFMIs covering recent advancements in control technologies, fault ride-through capabilities, stability enhancement measures, and practical implementations. Moreover, the challenges in adding GFMIs into existing power systems, including a seamless transition from grid-connected mode to the standalone mode and vice versa, are also discussed in detail. Recently commissioned projects in Australia, the UK, and the US are taken as examples to highlight the trend in the power industry in adding GFMIs to address issues related to weak grid scenarios. Research directions in terms of voltage control, frequency control, system strength improvement, and regulatory framework are also discussed. This paper serves as a resource for researchers and power system engineers exploring solutions to the emerging problems with high penetration of IBRs, focusing on GFMIs.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. pp, 1698-1703
Deterioration of Frequency Response in Low Inertia Networks due to Governor Dead-Bands
Renewable energy sources are increasingly replacing conventional fossil-fueled power plants in electric power systems around the world. As a result, the frequency excursions have become high due to the low synchronous inertia remaining in the system. An example is South Australia, where the generation mix heavily depends on renewable energy sources. Therefore, when South Australia is subjected to a non-credible contingency such as a network separation, the impact of governor dead-bands towards frequency stability can be significant. In this work, the influence of governor dead-bands on frequency nadir and quasi steady-state frequency is investigated. In turn, their effect towards the services, which are operating outside the normal operating frequency band, such as load shedding and frequency control services is discussed.
- 1 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. pp, 1698-1703
Deterioration of Frequency Response in Low Inertia Networks due to Governor Dead-Bands
Renewable energy sources are increasingly replacing conventional fossil-fueled power plants in electric power systems around the world. As a result, the frequency excursions have become high due to the low synchronous inertia remaining in the system. An example is South Australia, where the generation mix heavily depends on renewable energy sources. Therefore, when South Australia is subjected to a non-credible contingency such as a network separation, the impact of governor dead-bands towards frequency stability can be significant. In this work, the influence of governor dead-bands on frequency nadir and quasi steady-state frequency is investigated. In turn, their effect towards the services, which are operating outside the normal operating frequency band, such as load shedding and frequency control services is discussed.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 388-393
A dual purpose induction motor drive for a high inertia load with both quick run-up and power factor correction capability
High inertial loads are abundant in the industry and most of them are direct on line starter type induction machines with double cage rotors. Due to their higher starting time higher power dissipation in the rotor makes the rotor wear out and eventually gets destroyed. A new starting method proposed herein makes the motor start quickly and smoothly by using an inverter. After reaching it's steady state the motor is switched to draw power from the grid meanwhile the inverter is utilized to control the reactive power drawn from the grid. Thus allowing the motor run with unity or even leading power factor.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 388-393
A dual purpose induction motor drive for a high inertia load with both quick run-up and power factor correction capability
High inertial loads are abundant in the industry and most of them are direct on line starter type induction machines with double cage rotors. Due to their higher starting time higher power dissipation in the rotor makes the rotor wear out and eventually gets destroyed. A new starting method proposed herein makes the motor start quickly and smoothly by using an inverter. After reaching it's steady state the motor is switched to draw power from the grid meanwhile the inverter is utilized to control the reactive power drawn from the grid. Thus allowing the motor run with unity or even leading power factor.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A novel dead-time compensation scheme for PWM VSI drives
A novel dead time compensation scheme for Pulse Width Modulated (PWM) Voltage Source Inverter (VSI) drives is presented. Dead-time is essential to prevent short circuit of DC link in PWM inverters. This causes dead-time effect which results in output waveform distortions and undesired characteristics. This paper deals with a new dead-time compensation scheme where a different approach is used in inserting dead-time into PWM inverters such that it does not cause any effect due to the introduced dead-time. In this approach, dead-time is applied only for either one of the switches depending on the output current polarity, ensuring no DC link shortage. This technique ensures an accurate output voltage magnitude with no phase delays. Simulation and experimental results of the proposed method are presented to validate the effectiveness.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A novel dead-time compensation scheme for PWM VSI drives
A novel dead time compensation scheme for Pulse Width Modulated (PWM) Voltage Source Inverter (VSI) drives is presented. Dead-time is essential to prevent short circuit of DC link in PWM inverters. This causes dead-time effect which results in output waveform distortions and undesired characteristics. This paper deals with a new dead-time compensation scheme where a different approach is used in inserting dead-time into PWM inverters such that it does not cause any effect due to the introduced dead-time. In this approach, dead-time is applied only for either one of the switches depending on the output current polarity, ensuring no DC link shortage. This technique ensures an accurate output voltage magnitude with no phase delays. Simulation and experimental results of the proposed method are presented to validate the effectiveness.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 446-451
Effect of semiconductor devices' output parasitic capacitance on zero-current clamping phenomenon in PWM-VSI drives
In voltage source inverter drives (VSI), in order to avoid a shoot through in DC link due to the finite turn on and turn off times of the semiconductor devices a dead-time is inserted. Even though this dead-time is imperative it causes several aberrations in the output current waveform. Not only it gives rise to odd order harmonics but also it influences zero-current clamping. This paper investigates zero-current clamping phenomenon in a generic sense where output parasitic capacitance is in existence. The effects on voltage, power and torque due to the output parasitic capacitance is discussed. Simulations are carried out under practical conditions and results are presented. Results verify the credibility of the analysis.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 446-451
Effect of semiconductor devices' output parasitic capacitance on zero-current clamping phenomenon in PWM-VSI drives
In voltage source inverter drives (VSI), in order to avoid a shoot through in DC link due to the finite turn on and turn off times of the semiconductor devices a dead-time is inserted. Even though this dead-time is imperative it causes several aberrations in the output current waveform. Not only it gives rise to odd order harmonics but also it influences zero-current clamping. This paper investigates zero-current clamping phenomenon in a generic sense where output parasitic capacitance is in existence. The effects on voltage, power and torque due to the output parasitic capacitance is discussed. Simulations are carried out under practical conditions and results are presented. Results verify the credibility of the analysis.