Zhijing Liao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhijing Liao has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Guang Li
School of Engineering, The University of Manchester, Manchester, U.K.
7 shared publications - Peter Stansby
University of Manchester
4 shared publications - Christopher Edwards
College of Engineering, Mathematics and Physical Sciences, University of Exeter, Exeter, U.K.
3 shared publications Laura-Beth Jordan
FloWave Ocean Energy Research Facility, The University of Edinburgh, Edinburgh, U.K.
3 shared publicationsMichael Belmont
University of Exeter, Exeter, U.K.
3 shared publicationsMustafa Al-Ani
Bristol Research and Innovation Laboratory, Toshiba Europe Ltd., Bristol, U.K.
3 shared publications
Latest Publications
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (3) , 1743-1753
A Sea-State-Dependent Control Strategy for Wave Energy Converters: Power Limiting in Large Wave Conditions and Energy Maximising in Moderate Wave Conditions
Conventional control strategies for wave energy converters (WECs) maximise power capture of the WEC by amplifying its responses, but this exacerbates hardware constraint violations not generally taken into account, causing undesirable shutdown of electrical systems in adverse wave conditions. When WECs operate close to power take-off (PTO) capacity, the primary control objective is to limit peak power for hardware protection purposes, enabling longer continuous electricity generation time. In this paper, we propose a sea-state-dependent control strategy based on model predictive control to maximise the annual energy production of a WEC with a realistic PTO: in small to moderate sea states it adopts a conventional energy-maximising objective function to increase output power, while in higher sea states a speed-limiting objective function may be utilised to enable longer generating time before shutdown becomes necessary. While this control strategy applies to a wide range of WECs, here we carry out the case study on an attenuator WEC called M4, with gearbox transmission and a permanent magnet synchronous generator (PMSG) as its PTO, which is being designed for a 1/4 scale ocean test in Albany, Australia. Simulation results show that compared with a benchmark passive damping controller, a 66% increase in annual energy production can be expected at the targeted site.
- 5 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 15 (3) , 1743-1753
A Sea-State-Dependent Control Strategy for Wave Energy Converters: Power Limiting in Large Wave Conditions and Energy Maximising in Moderate Wave Conditions
Conventional control strategies for wave energy converters (WECs) maximise power capture of the WEC by amplifying its responses, but this exacerbates hardware constraint violations not generally taken into account, causing undesirable shutdown of electrical systems in adverse wave conditions. When WECs operate close to power take-off (PTO) capacity, the primary control objective is to limit peak power for hardware protection purposes, enabling longer continuous electricity generation time. In this paper, we propose a sea-state-dependent control strategy based on model predictive control to maximise the annual energy production of a WEC with a realistic PTO: in small to moderate sea states it adopts a conventional energy-maximising objective function to increase output power, while in higher sea states a speed-limiting objective function may be utilised to enable longer generating time before shutdown becomes necessary. While this control strategy applies to a wide range of WECs, here we carry out the case study on an attenuator WEC called M4, with gearbox transmission and a permanent magnet synchronous generator (PMSG) as its PTO, which is being designed for a 1/4 scale ocean test in Albany, Australia. Simulation results show that compared with a benchmark passive damping controller, a 66% increase in annual energy production can be expected at the targeted site.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (3) , 1737-1746
Modelling and Control Tank Testing Validation for Attenuator Type Wave Energy Converter – Part III: Model Predictive Control and Robustness Validation
Following the tank testing results of linear passive damping control and linear non-causal optimal control (LNOC) in the Part I and Part II papers, this paper presents further tank testing results focusing on two aspects: Firstly, a model predictive controller (MPC) is designed based on the model developed by system identification in Part I to optimally handle actuator saturation limits. The MPC control is demonstrated to significantly improve the energy output by 9.86% up to 463.42% compared with a well-tuned passive damper and can also outperform the LNOC presented in Part II in a range of irregular unidirectional waves. Secondly, the robustness of the MPC controller and the LNOC controller is validated in more realistic sea conditions when directional spreading waves and side waves are superimposed onto the dominant directional waves. The test results show that both MPC and LNOC can still significantly outperform the passive damping controller in all the sea conditions. These tank testing results pave a solid way for future sea trial testing of these advanced non-causal optimal control strategies developed for wave energy converters in sea trials.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (3) , 1737-1746
Modelling and Control Tank Testing Validation for Attenuator Type Wave Energy Converter – Part III: Model Predictive Control and Robustness Validation
Following the tank testing results of linear passive damping control and linear non-causal optimal control (LNOC) in the Part I and Part II papers, this paper presents further tank testing results focusing on two aspects: Firstly, a model predictive controller (MPC) is designed based on the model developed by system identification in Part I to optimally handle actuator saturation limits. The MPC control is demonstrated to significantly improve the energy output by 9.86% up to 463.42% compared with a well-tuned passive damper and can also outperform the LNOC presented in Part II in a range of irregular unidirectional waves. Secondly, the robustness of the MPC controller and the LNOC controller is validated in more realistic sea conditions when directional spreading waves and side waves are superimposed onto the dominant directional waves. The test results show that both MPC and LNOC can still significantly outperform the passive damping controller in all the sea conditions. These tank testing results pave a solid way for future sea trial testing of these advanced non-causal optimal control strategies developed for wave energy converters in sea trials.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (3) , 1747-1757
Modelling and Control Tank Testing Validation for Attenuator Type Wave Energy Converter - Part I: Experiment Setup and Control-Oriented Modelling
Advanced non-causal optimal control strategies have been demonstrated to significantly improve the energy output of a scale physical model of an attenuator type wave energy converter (WEC) by tank testing experiments using FloWave tank facilities in Edinburgh supported by Wave Energy Scotland's control project. The results are reported in a series of three papers, summarizing the tank testing setup, dynamic modelling, and validation of both linear non-causal optimal control (LNOC) and model predictive control (MPC) in regular and irregular waves. Compared with an optimally tuned passive damping control, both LNOC and MPC can significantly improve the energy output, by between 10% to 460%, using irregular waves with low to medium magnitude and peak periods ranging from $1.7\,\mathrm{s}$ to $2.8\,\mathrm{s}$ at $1/20^{\rm th}$ scale, as shown in Part II and Part III papers. These controllers also show robust performance in spread waves and side waves which are normally encountered in real sea conditions. Furthermore, the control technologies can be transferred to other types of WECs. The results pave the way for the sea trial testing and full control system validation involving the electricity generation stage and power conditioning stage. This Part I paper will focus on the tank testing setup, the passive damping control experimental results, and the control-oriented models for the WEC. Two state-space models derived respectively from the hydrodynamic model and system identification of experimental data, are validated and compared for use on the controller designs to be presented in Part II and Part III.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (3) , 1747-1757
Modelling and Control Tank Testing Validation for Attenuator Type Wave Energy Converter - Part I: Experiment Setup and Control-Oriented Modelling
Advanced non-causal optimal control strategies have been demonstrated to significantly improve the energy output of a scale physical model of an attenuator type wave energy converter (WEC) by tank testing experiments using FloWave tank facilities in Edinburgh supported by Wave Energy Scotland's control project. The results are reported in a series of three papers, summarizing the tank testing setup, dynamic modelling, and validation of both linear non-causal optimal control (LNOC) and model predictive control (MPC) in regular and irregular waves. Compared with an optimally tuned passive damping control, both LNOC and MPC can significantly improve the energy output, by between 10% to 460%, using irregular waves with low to medium magnitude and peak periods ranging from $1.7\,\mathrm{s}$ to $2.8\,\mathrm{s}$ at $1/20^{\rm th}$ scale, as shown in Part II and Part III papers. These controllers also show robust performance in spread waves and side waves which are normally encountered in real sea conditions. Furthermore, the control technologies can be transferred to other types of WECs. The results pave the way for the sea trial testing and full control system validation involving the electricity generation stage and power conditioning stage. This Part I paper will focus on the tank testing setup, the passive damping control experimental results, and the control-oriented models for the WEC. Two state-space models derived respectively from the hydrodynamic model and system identification of experimental data, are validated and compared for use on the controller designs to be presented in Part II and Part III.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (3) , 1758-1768
Modelling and Control Tank Testing Validation for Attenuator Type Wave Energy Converter - Part II: Linear Noncausal Optimal Control and Deterministic Sea Wave Prediction Tank Testing
Tank testing results from applying Linear non-causal optimal control (LNOC) to the Mocean M100 wave energy converter (WEC) are presented in this paper. Based on the two state-space models derived from Part I, two LNOC algorithms designed to increase power capture of the $1/20$ scaled M100 WEC prototype are tested separately in real-time under various irregular wave conditions. The deterministic sea wave prediction (DSWP) algorithm is employed to provide the required wave elevation/excitation force predictions for the LNOC using real-time wave measurements. Experimental data shows that the DSWP can predict the incoming waves with sufficiently high accuracy in various sea states. Compared with a well-tuned passive damper, LNOC based on a hydrodynamic model increases the power capture by up to 128% while LNOC based on a system identification (SysID) model increases the power capture by up to 323%. The technologies are transferrable. The testing procedure and the results also provide informative guidance for the tank testing of other advanced optimal controllers and their implementations on other types of WECs.
- 17 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 14 (3) , 1758-1768
Modelling and Control Tank Testing Validation for Attenuator Type Wave Energy Converter - Part II: Linear Noncausal Optimal Control and Deterministic Sea Wave Prediction Tank Testing
Tank testing results from applying Linear non-causal optimal control (LNOC) to the Mocean M100 wave energy converter (WEC) are presented in this paper. Based on the two state-space models derived from Part I, two LNOC algorithms designed to increase power capture of the $1/20$ scaled M100 WEC prototype are tested separately in real-time under various irregular wave conditions. The deterministic sea wave prediction (DSWP) algorithm is employed to provide the required wave elevation/excitation force predictions for the LNOC using real-time wave measurements. Experimental data shows that the DSWP can predict the incoming waves with sufficiently high accuracy in various sea states. Compared with a well-tuned passive damper, LNOC based on a hydrodynamic model increases the power capture by up to 128% while LNOC based on a system identification (SysID) model increases the power capture by up to 323%. The technologies are transferrable. The testing procedure and the results also provide informative guidance for the tank testing of other advanced optimal controllers and their implementations on other types of WECs.
- Open Access
- 3 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (3) , 1443-1450
A Fast Model Predictive Control Framework for Multi-Float and Multi-Mode-Motion Wave Energy Converters
Recently, multi-float and multi-mode-motion wave energy converters (M-WECs) have been developed to improve energy conversion capability. Although model predictive control (MPC) can be very effective to solve the constrained energy maximization control problem of point absorber WECs, the increased complexity of the M-WEC hydrodynamics can bring significant challenges due to computational demand. This brief proposes a novel computational-efficient fast MPC (FMPC) design method for the M-WECs requiring complex linear hydrodynamic models. The controller design objective is to maximize the energy conversion with some available wave forecasting information and to satisfy state and control input constraints to ensure safe operation. The main advantage of the proposed FMPC is the reduced computational burden with a negligible impact on performance. A demonstrative numerical simulation based on a 1:50 laboratory-scale M-WEC design, M4, for which linear hydrodynamics has been verified experimentally, is presented to verify the efficacy of the proposed control method in terms of both computational load and energy output.
- 3 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 31 (3) , 1443-1450
Open AccessA Fast Model Predictive Control Framework for Multi-Float and Multi-Mode-Motion Wave Energy Converters
Recently, multi-float and multi-mode-motion wave energy converters (M-WECs) have been developed to improve energy conversion capability. Although model predictive control (MPC) can be very effective to solve the constrained energy maximization control problem of point absorber WECs, the increased complexity of the M-WEC hydrodynamics can bring significant challenges due to computational demand. This brief proposes a novel computational-efficient fast MPC (FMPC) design method for the M-WECs requiring complex linear hydrodynamic models. The controller design objective is to maximize the energy conversion with some available wave forecasting information and to satisfy state and control input constraints to ensure safe operation. The main advantage of the proposed FMPC is the reduced computational burden with a negligible impact on performance. A demonstrative numerical simulation based on a 1:50 laboratory-scale M-WEC design, M4, for which linear hydrodynamics has been verified experimentally, is presented to verify the efficacy of the proposed control method in terms of both computational load and energy output.
- 20 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 2123-2131
High-Capacity Wave Energy Conversion by Multi-Float, Multi-PTO, Control and Prediction: Generalized State-Space Modelling With Linear Optimal Control and Arbitrary Headings
Wave energy converters with capacity similar to, or greater than, wind turbines are desirable for the supply of electricity to the grid. It is shown that this may be provided by multiple floats in a hinged raft-type configuration with multi-mode forcing. The case analysed has 8 floats and 4 power take off (PTO) units. Analysis is based on linear diffraction-radiation modelling, validated in wave basin experiments with a smaller number of floats. Control is desirable to improve energy capture, mainly demonstrated for point absorbers, but this has not previously been applied to such a complex problem with many degrees of freedom. The linear hydrodynamic model in a state-space form makes it possible to implement advanced control algorithms in real time. Linear non-causal optimal control (LNOC) is applied with wave force prediction from auto-regression. For the design case with zero heading, as the configuration heads naturally into the wave direction, energy capture is improved by between 21% and 83%. The energy capture is about 62% the maximum possible from idealised analyses. Off-design, non-zero headings are also analysed to indicate how energy capture can be reduced; the contribution from different modes of forcing varies with heading and energy capture is always improved by control, by several times at $90^{\circ }$ heading.
- 20 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 12 (4) , 2123-2131
High-Capacity Wave Energy Conversion by Multi-Float, Multi-PTO, Control and Prediction: Generalized State-Space Modelling With Linear Optimal Control and Arbitrary Headings
Wave energy converters with capacity similar to, or greater than, wind turbines are desirable for the supply of electricity to the grid. It is shown that this may be provided by multiple floats in a hinged raft-type configuration with multi-mode forcing. The case analysed has 8 floats and 4 power take off (PTO) units. Analysis is based on linear diffraction-radiation modelling, validated in wave basin experiments with a smaller number of floats. Control is desirable to improve energy capture, mainly demonstrated for point absorbers, but this has not previously been applied to such a complex problem with many degrees of freedom. The linear hydrodynamic model in a state-space form makes it possible to implement advanced control algorithms in real time. Linear non-causal optimal control (LNOC) is applied with wave force prediction from auto-regression. For the design case with zero heading, as the configuration heads naturally into the wave direction, energy capture is improved by between 21% and 83%. The energy capture is about 62% the maximum possible from idealised analyses. Off-design, non-zero headings are also analysed to indicate how energy capture can be reduced; the contribution from different modes of forcing varies with heading and energy capture is always improved by control, by several times at $90^{\circ }$ heading.
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1278-1286
Linear Non-Causal Optimal Control of an Attenuator Type Wave Energy Converter M4
Ocean waves provide a promising and abundant renewable energy resource. One reason wave energy technology is still not mature enough for commercialization is the high unit cost of generated electricity. This needs to be improved by combination of device and associated controller design. A multi-float and multi-mode-motion WEC (M-WEC) enables much higher energy conversion compared with a single-float, single-mode WEC (S-WEC); however, the added complexity in dynamics of an M-WEC makes the corresponding controller design more challenging. While all WEC control research has been based on the control of S-WECs it has shown that control can significantly improve energy conversion. This paper aims to design a linear non-causal optimal controller for a M-WEC to demonstrate that this improvement also applies to more complex systems with greater capacity and potentially lower electricity cost. We choose a multi-body attenuator type M-WEC called M4 for which the desirable feature of predominantly linear dynamics has been demonstrated. This means that a linear controller can be designed within a linear hydrodynamic model without introducing an intractable computational burden for real-time controller implementation. Numerical results show that the designed controller can significantly improve the performance of M4 over various wave periods by 40% to 100%.
- 13 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 11 (3) , 1278-1286
Linear Non-Causal Optimal Control of an Attenuator Type Wave Energy Converter M4
Ocean waves provide a promising and abundant renewable energy resource. One reason wave energy technology is still not mature enough for commercialization is the high unit cost of generated electricity. This needs to be improved by combination of device and associated controller design. A multi-float and multi-mode-motion WEC (M-WEC) enables much higher energy conversion compared with a single-float, single-mode WEC (S-WEC); however, the added complexity in dynamics of an M-WEC makes the corresponding controller design more challenging. While all WEC control research has been based on the control of S-WECs it has shown that control can significantly improve energy conversion. This paper aims to design a linear non-causal optimal controller for a M-WEC to demonstrate that this improvement also applies to more complex systems with greater capacity and potentially lower electricity cost. We choose a multi-body attenuator type M-WEC called M4 for which the desirable feature of predominantly linear dynamics has been demonstrated. This means that a linear controller can be designed within a linear hydrodynamic model without introducing an intractable computational burden for real-time controller implementation. Numerical results show that the designed controller can significantly improve the performance of M4 over various wave periods by 40% to 100%.