Romain Vayron
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Romain Vayron has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Jaber
Université Polytechnique Hauts-de-France, LAMIH, CNRS, UMR 8201, F-59313 Valenciennes, France
2 shared publications - Céline Falentin-Daudré
BEST/CB3S, UMR CNRS 7244, Institut Galilée, Université Sorbonne Paris Nord, Villetaneuse, 93430, France
2 shared publications - Frederic Robache
Univ. Polytechnique Hauts-de-France, CNRS, UMR 8201 - LAMIH - Laboratoire d’Automatique de Mécanique et d’Informatique Industrielles et Humaines, F-59313 Valenciennes, France
2 shared publications - Guillaume Haiat
Laboratoire Modelisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du General de Gaulle, 94010 Creteil, France
2 shared publications - Maxence Bigerelle
Univ. Polytechnique Hauts-de-France, CNRS, UMR 8201 - LAMIH - Laboratoire d’Automatique de Mécanique et d’Informatique Industrielles et Humaines, F-59313 Valenciennes, France
2 shared publications - Sophie Le Cann
Department of Biomedical Engineering, Lund University, Lund, Sweden
2 shared publications
Latest Publications
- Open Access
Femtosecond Laser Texturing of Ti-6Al-4V: From Ablation Behavior to Controlled Bi-Sinusoidal Surface Morphology
This work presents a systematic methodology for generating bi-sinusoidal surface topographies with controlled and reproducible characteristics on Ti-6Al-4V using a progressive 1D–2D–3D framework. Such deterministic topographies are of interest for dental implants, where surface micro-texture can influence an early biological response and osseointegration. Single-pulse ablation thresholds were first determined to be 0.175 J/cm2 at a 1031 nm wavelength using 306 fs pulses, with no polarization dependence. Studies were then carried out to identify fundamental ablation parameters, optimize scanning conditions for planar texturing, and extend the process to controlled three-dimensional surface architectures. During the 1D stage, increasing the fluence from 0.26 to 6.52 J/cm2 enlarged the crater diameter from approximately 7 to 32 µm and increased the areal roughness Sa from 0.012 to 0.020 µm. With an increasing pulse number, the crater diameter continued to grow up to 25 pulses before stabilizing. Multi-pulse tests below the threshold showed that repeated exposures caused ablation, highlighting incubation and energy accumulation, with an incubation factor of S = 0.84. In the 2D stage, scanned irradiation was used to quantify how fluence and pulse overlap affect the ablated depth and areal roughness, with depth increasing linearly with the number of passes, and roughness strongly governed by overlap and fluence. Finally, 3D texturing combining x–y scanning with a z-axis focal adjustment enabled reproducible bi-sinusoidal topographies.
Open AccessFemtosecond Laser Texturing of Ti-6Al-4V: From Ablation Behavior to Controlled Bi-Sinusoidal Surface Morphology
This work presents a systematic methodology for generating bi-sinusoidal surface topographies with controlled and reproducible characteristics on Ti-6Al-4V using a progressive 1D–2D–3D framework. Such deterministic topographies are of interest for dental implants, where surface micro-texture can influence an early biological response and osseointegration. Single-pulse ablation thresholds were first determined to be 0.175 J/cm2 at a 1031 nm wavelength using 306 fs pulses, with no polarization dependence. Studies were then carried out to identify fundamental ablation parameters, optimize scanning conditions for planar texturing, and extend the process to controlled three-dimensional surface architectures. During the 1D stage, increasing the fluence from 0.26 to 6.52 J/cm2 enlarged the crater diameter from approximately 7 to 32 µm and increased the areal roughness Sa from 0.012 to 0.020 µm. With an increasing pulse number, the crater diameter continued to grow up to 25 pulses before stabilizing. Multi-pulse tests below the threshold showed that repeated exposures caused ablation, highlighting incubation and energy accumulation, with an incubation factor of S = 0.84. In the 2D stage, scanned irradiation was used to quantify how fluence and pulse overlap affect the ablated depth and areal roughness, with depth increasing linearly with the number of passes, and roughness strongly governed by overlap and fluence. Finally, 3D texturing combining x–y scanning with a z-axis focal adjustment enabled reproducible bi-sinusoidal topographies.
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Remodelage osseux et stabilité d'implants
Du fait de l'augmentation de la durée de vie de la population et de la fréquence de certains types d'accidents, la problématique de l'évolution des articulations et du vieillissement osseux devient primordiale, ce qui implique de nombreuses opérations chirurgicales nécessitant une pose d'implant. Bien que ces interventions soient réalisées depuis longtemps de façon routinière, il subsiste des risques d'échec chirurgical pouvant avoir des conséquences dramatiques pour le patient. Malgré les évolutions apportées, le taux d'échec implantaire est encore important car les phénomènes mis en jeu restent mal compris du fait de leur complexité et de leur nature multi-échelle. Un des aspects essentiels de la réussite des ces opérations concerne l'ostéointégration de l'implant, c'est-à-dire la capacité de l'os à se régénérer autour de ce corps étranger en l'intégrant durablement. La réussite chirurgicale dépend en premier lieu des caractéristiques physiques de l'interface os-implant transmettant les efforts biomécaniques qui jouent un rôle majeur dans le remodelage osseux. Ces travaux de recherche s'inscrivent dans le cadre du développement d'une approche expérimentale multimodale pour la caractérisation de l'interface os-implant afin d'évaluer l'impact de la reconstruction osseuse sur la réponse mécanique de l'implant. La première partie met en œuvre une approche multiphysique utilisant un modèle animal dédié. Des pastilles en titane sont implantées in vivo sur la partie proximale du tibia du lapin pendant différents temps de cicatrisation. Une technique de nanoindentation permet de mesurer les propriétés mécaniques de l'os néoformé à l'échelle microscopique. La technique de diffusion micro-Brillouin permet de mesurer la vitesse ultrasonore de l'os néoformé à la même échelle. Les résultats obtenus à partir de ces deux techniques permettent de déterminer la différence de densité volumique entre l'os mature et l'os néoformé aux différents temps de cicatrisation considérés. Dans la seconde partie, un dispositif ultrasonore destiné à l'étude de la stabilité d'implants dentaires en titane est présenté. La réponse ultrasonore obtenue en mode échographique est sensible aux propriétés du matériau (os, biomatériau) au contact de l'implant. Premièrement, la réponse ultrasonore d'implants dentaires insérés dans un substitut dentaire bioactif (silicate tricalcique) et sollicités par un protocole de fatigue mécanique in vitro est mesurée. Pour cela, un banc de fatigue mécanique simulant la mastication a été développé. Deuxièmement, ce même dispositif ultrasonore est utilisé pour déterminer in vitro la stabilité primaire d'un implant dentaire placé dans un os bovin. Troisièmement, une étude in vivo utilisant un modèle animal (lapins) a permis de mettre en évidence l'effet du temps de cicatrisation sur la réponse ultrasonore de l'implant. Ce dispositif ultrasonore permet de quantifier la stabilité primaire et secondaire d'un implant dentaire. Les phénomènes de propagation ultrasonore dans l'implant sont modélisés en utilisant des techniques de simulations numériques par éléments finis. Les simulations montrent le potentiel de la technique pour suivre les variations de plusieurs paramètres déterminants pour l'ostéointégration de l'implant dans des conditions contrôlées
- 31 March 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Remodelage osseux et stabilité d'implants
Du fait de l'augmentation de la durée de vie de la population et de la fréquence de certains types d'accidents, la problématique de l'évolution des articulations et du vieillissement osseux devient primordiale, ce qui implique de nombreuses opérations chirurgicales nécessitant une pose d'implant. Bien que ces interventions soient réalisées depuis longtemps de façon routinière, il subsiste des risques d'échec chirurgical pouvant avoir des conséquences dramatiques pour le patient. Malgré les évolutions apportées, le taux d'échec implantaire est encore important car les phénomènes mis en jeu restent mal compris du fait de leur complexité et de leur nature multi-échelle. Un des aspects essentiels de la réussite des ces opérations concerne l'ostéointégration de l'implant, c'est-à-dire la capacité de l'os à se régénérer autour de ce corps étranger en l'intégrant durablement. La réussite chirurgicale dépend en premier lieu des caractéristiques physiques de l'interface os-implant transmettant les efforts biomécaniques qui jouent un rôle majeur dans le remodelage osseux. Ces travaux de recherche s'inscrivent dans le cadre du développement d'une approche expérimentale multimodale pour la caractérisation de l'interface os-implant afin d'évaluer l'impact de la reconstruction osseuse sur la réponse mécanique de l'implant. La première partie met en œuvre une approche multiphysique utilisant un modèle animal dédié. Des pastilles en titane sont implantées in vivo sur la partie proximale du tibia du lapin pendant différents temps de cicatrisation. Une technique de nanoindentation permet de mesurer les propriétés mécaniques de l'os néoformé à l'échelle microscopique. La technique de diffusion micro-Brillouin permet de mesurer la vitesse ultrasonore de l'os néoformé à la même échelle. Les résultats obtenus à partir de ces deux techniques permettent de déterminer la différence de densité volumique entre l'os mature et l'os néoformé aux différents temps de cicatrisation considérés. Dans la seconde partie, un dispositif ultrasonore destiné à l'étude de la stabilité d'implants dentaires en titane est présenté. La réponse ultrasonore obtenue en mode échographique est sensible aux propriétés du matériau (os, biomatériau) au contact de l'implant. Premièrement, la réponse ultrasonore d'implants dentaires insérés dans un substitut dentaire bioactif (silicate tricalcique) et sollicités par un protocole de fatigue mécanique in vitro est mesurée. Pour cela, un banc de fatigue mécanique simulant la mastication a été développé. Deuxièmement, ce même dispositif ultrasonore est utilisé pour déterminer in vitro la stabilité primaire d'un implant dentaire placé dans un os bovin. Troisièmement, une étude in vivo utilisant un modèle animal (lapins) a permis de mettre en évidence l'effet du temps de cicatrisation sur la réponse ultrasonore de l'implant. Ce dispositif ultrasonore permet de quantifier la stabilité primaire et secondaire d'un implant dentaire. Les phénomènes de propagation ultrasonore dans l'implant sont modélisés en utilisant des techniques de simulations numériques par éléments finis. Les simulations montrent le potentiel de la technique pour suivre les variations de plusieurs paramètres déterminants pour l'ostéointégration de l'implant dans des conditions contrôlées
- Open Access
Determining Relevant 3D Roughness Parameters for Sandblasted Surfaces: A Methodological Approach
This study presents a robust methodology for analyzing 3D roughness parameters to characterize sandblasted surfaces, identifying the most relevant descriptors for process optimization. Sandblasting with irregularly shaped corundum particles is performed using five grit sizes (25, 50, 90, 125, and 250 µm) and three pressure levels (2, 3, and 4 bar). The resulting surfaces are characterized through eight 3D roughness parameters: Sa, Spc, Sal, Sfd, Sdq, Sdr, Spd, and Str. A linear model of the form Q = a + b.D + d.D.P, where Q represents the roughness parameter, D is the average grit size, and P is the sandblasting pressure, is employed. For Spd, a nonlinear model, Spd = (a + b.D + d.D.P)2, yields a significantly improved determination coefficient, demonstrating the model’s enhanced ability to capture the complexity of the Spd parameter. The double-bootstrap analysis validates the statistical significance of all models, providing confidence intervals for each parameter. This approach emphasizes the importance of advanced 3D roughness descriptors for accurately analyzing surface textures in sandblasting processes, offering a reliable framework for surface characterization and industrial optimization.
Open AccessDetermining Relevant 3D Roughness Parameters for Sandblasted Surfaces: A Methodological Approach
This study presents a robust methodology for analyzing 3D roughness parameters to characterize sandblasted surfaces, identifying the most relevant descriptors for process optimization. Sandblasting with irregularly shaped corundum particles is performed using five grit sizes (25, 50, 90, 125, and 250 µm) and three pressure levels (2, 3, and 4 bar). The resulting surfaces are characterized through eight 3D roughness parameters: Sa, Spc, Sal, Sfd, Sdq, Sdr, Spd, and Str. A linear model of the form Q = a + b.D + d.D.P, where Q represents the roughness parameter, D is the average grit size, and P is the sandblasting pressure, is employed. For Spd, a nonlinear model, Spd = (a + b.D + d.D.P)2, yields a significantly improved determination coefficient, demonstrating the model’s enhanced ability to capture the complexity of the Spd parameter. The double-bootstrap analysis validates the statistical significance of all models, providing confidence intervals for each parameter. This approach emphasizes the importance of advanced 3D roughness descriptors for accurately analyzing surface textures in sandblasting processes, offering a reliable framework for surface characterization and industrial optimization.
- Open Access
Simple UV-Grafting of PolyAcrylic and PolyMethacrylic Acid on Silicone Breast Implant Surfaces: Chemical and Mechanical Characterizations
Poly(dimethyl siloxane) (PDMS) is one of the most widely used materials in the biomedical field. Despite its numerous advantages, its hydrophobic character promotes bacterial adhesion and biofilm formation. For breast implants, biocompatibility is challenged due to the biofilm formed around the implant that can degenerate to severe capsular contracture over time. Thus, the laboratory has set up strategies to prevent bacterial contamination by grafting covalently hydrophilic bioactive polymers on the surface of implants. In this study, poly(methacrylic acid) (PMAc) and poly(acrylic acid) (PAAc) were chosen as non-toxic and biocompatible bioactive polymers known for reducing bacteria adhesion. These polymers are also good candidates to lend reactivity on the surface for further functionalization. X-ray photoelectron Spectroscopy (XPS) and Fourier-Transform Infrared spectroscopy (FTIR) analysis have highlighted the covalent grafting of these polymers. Apparent water contact angle measurements have shown the change in hydrophilicity on the surface, and a colorimetric assay allowed us to assess the grafting rate of PMAc and PAAc. Tensile strength assays were performed to ensure that the functionalization process does not significantly alter the material’s mechanical properties. Analyses of the surface aspect and roughness by Scanning Electron Microscope (SEM) and optical profilometer allow us to formulate hypotheses to approach the understanding of the behavior of the polymer once grafted.
Open AccessSimple UV-Grafting of PolyAcrylic and PolyMethacrylic Acid on Silicone Breast Implant Surfaces: Chemical and Mechanical Characterizations
Poly(dimethyl siloxane) (PDMS) is one of the most widely used materials in the biomedical field. Despite its numerous advantages, its hydrophobic character promotes bacterial adhesion and biofilm formation. For breast implants, biocompatibility is challenged due to the biofilm formed around the implant that can degenerate to severe capsular contracture over time. Thus, the laboratory has set up strategies to prevent bacterial contamination by grafting covalently hydrophilic bioactive polymers on the surface of implants. In this study, poly(methacrylic acid) (PMAc) and poly(acrylic acid) (PAAc) were chosen as non-toxic and biocompatible bioactive polymers known for reducing bacteria adhesion. These polymers are also good candidates to lend reactivity on the surface for further functionalization. X-ray photoelectron Spectroscopy (XPS) and Fourier-Transform Infrared spectroscopy (FTIR) analysis have highlighted the covalent grafting of these polymers. Apparent water contact angle measurements have shown the change in hydrophilicity on the surface, and a colorimetric assay allowed us to assess the grafting rate of PMAc and PAAc. Tensile strength assays were performed to ensure that the functionalization process does not significantly alter the material’s mechanical properties. Analyses of the surface aspect and roughness by Scanning Electron Microscope (SEM) and optical profilometer allow us to formulate hypotheses to approach the understanding of the behavior of the polymer once grafted.
- Open Access
Influence of Surface Roughness on Nanocrystalline Diamond Films Deposited by Distributed Antenna Array Microwave System on TA6V Substrates
In this study, the characteristics of nanocrystalline diamond films synthesized at low surface temperature on Ti-6Al-4V (TA6V) substrates using a distributed antenna array microwave reactor aiming at biomedical applications were investigated. The surface roughness of the TA6V substrates is varied by scratching with emery paper of 1200, 2400, 4000 polishing grit. Nanocrystalline diamond (NCD) coatings with morphology, purity, and microstructure comparable to those obtained on silicon substrates usually employed in the same reactor and growth conditions are successfully achieved whatever the polishing protocol. However, the latter has a significant effect on the roughness parameters and hardness of the NCD films. The use of the finest polishing grit thus permits us to enhance the hardness value, which can be related to the work-hardening phenomenon arising from the polishing process.
Open AccessInfluence of Surface Roughness on Nanocrystalline Diamond Films Deposited by Distributed Antenna Array Microwave System on TA6V Substrates
In this study, the characteristics of nanocrystalline diamond films synthesized at low surface temperature on Ti-6Al-4V (TA6V) substrates using a distributed antenna array microwave reactor aiming at biomedical applications were investigated. The surface roughness of the TA6V substrates is varied by scratching with emery paper of 1200, 2400, 4000 polishing grit. Nanocrystalline diamond (NCD) coatings with morphology, purity, and microstructure comparable to those obtained on silicon substrates usually employed in the same reactor and growth conditions are successfully achieved whatever the polishing protocol. However, the latter has a significant effect on the roughness parameters and hardness of the NCD films. The use of the finest polishing grit thus permits us to enhance the hardness value, which can be related to the work-hardening phenomenon arising from the polishing process.
- 21 March 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (13) , 4712-4719
Healthy and Pathological Porcine Blood Drop Evaporation: Effect of the Temperature
This study aims to understand and compare the evaporation dynamics of drops of healthy and pathological porcine blood (glomerulonephritis disease) evaporated on hydrophilic glass substrates at different surface temperatures (Ts): 23, 37, 60, and 90 degrees C. Subsequently, the different induced phenomena are characterized and described. Additionally, drops of water were evaporated at these four surface temperatures to better understand the difference between healthy and pathological porcine blood. Statistical studies were performed to analyze the evaporation rate, the maximum and average values of Marangoni numbers (Ma), and the evaporated specific time. The statistical tests showed significant differences in these parameters between healthy and pathological blood for each surface temperature. The mean and the maximum of the Ma increase with the increase in Ts caused by the increase in the temperature differences between the edge and the center of the drop. When comparing healthy and diseased blood, the Ma maximum and mean of healthy blood were higher than those of diseased blood for all Ts. Besides, this study emphasizes the influence of temperature on blood evaporation and the pattern caused by the Marangoni effect. These results demonstrate that differences between the two blood types are related to the disease and pave the way to developing a new methodology for medical decision-making.
- 21 March 2023
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 39 (13) , 4712-4719
Healthy and Pathological Porcine Blood Drop Evaporation: Effect of the Temperature
This study aims to understand and compare the evaporation dynamics of drops of healthy and pathological porcine blood (glomerulonephritis disease) evaporated on hydrophilic glass substrates at different surface temperatures (Ts): 23, 37, 60, and 90 degrees C. Subsequently, the different induced phenomena are characterized and described. Additionally, drops of water were evaporated at these four surface temperatures to better understand the difference between healthy and pathological porcine blood. Statistical studies were performed to analyze the evaporation rate, the maximum and average values of Marangoni numbers (Ma), and the evaporated specific time. The statistical tests showed significant differences in these parameters between healthy and pathological blood for each surface temperature. The mean and the maximum of the Ma increase with the increase in Ts caused by the increase in the temperature differences between the edge and the center of the drop. When comparing healthy and diseased blood, the Ma maximum and mean of healthy blood were higher than those of diseased blood for all Ts. Besides, this study emphasizes the influence of temperature on blood evaporation and the pattern caused by the Marangoni effect. These results demonstrate that differences between the two blood types are related to the disease and pave the way to developing a new methodology for medical decision-making.
- 28 October 2020
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 142 (12)
Multimodal Evaluation of the Spatiotemporal Variations of Periprosthetic Bone Properties
Titanium implants are widely used in dental and orthopedic surgeries. However, implant failures still occur because of a lack of implant stability. The biomechanical properties of bone tissue located around the implant need to be assessed to better understand the osseointegration phenomena and anticipate implant failure. The aim of this study was to explore the spatiotemporal variation of the microscopic elastic properties of newly formed bone tissue close to an implant. Eight coin-shaped Ti6Al4V implants were inserted into rabbit tibiae for 7 and 13 weeks using an in vivo model allowing the distinction between mature and newly formed bone in a standardized configuration. Nanoindentation and micro-Brillouin scattering measurements were carried out in similar locations to measure the indentation modulus and the wave velocity, from which relative variations of bone mass density were extracted. The indentation modulus, the wave velocity and mass density were found to be higher (1) in newly formed bone tissue located close to the implant surface, compared to mature cortical bone tissue, and (2) after longer healing time, consistently with an increased mineralization. Within the bone chamber, the spatial distribution of elastic properties was more heterogeneous for shorter healing durations. After 7 weeks of healing, bone tissue in the bone chamber close to the implant surface was 12.3% denser than bone tissue further away. Bone tissue close to the chamber edge was 16.8% denser than in its center. These results suggest a bone spreading pathway along tissue maturation, which is confirmed by histology and consistent with contact osteogenesis phenomena.
- 28 October 2020
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 142 (12)
Multimodal Evaluation of the Spatiotemporal Variations of Periprosthetic Bone Properties
Titanium implants are widely used in dental and orthopedic surgeries. However, implant failures still occur because of a lack of implant stability. The biomechanical properties of bone tissue located around the implant need to be assessed to better understand the osseointegration phenomena and anticipate implant failure. The aim of this study was to explore the spatiotemporal variation of the microscopic elastic properties of newly formed bone tissue close to an implant. Eight coin-shaped Ti6Al4V implants were inserted into rabbit tibiae for 7 and 13 weeks using an in vivo model allowing the distinction between mature and newly formed bone in a standardized configuration. Nanoindentation and micro-Brillouin scattering measurements were carried out in similar locations to measure the indentation modulus and the wave velocity, from which relative variations of bone mass density were extracted. The indentation modulus, the wave velocity and mass density were found to be higher (1) in newly formed bone tissue located close to the implant surface, compared to mature cortical bone tissue, and (2) after longer healing time, consistently with an increased mineralization. Within the bone chamber, the spatial distribution of elastic properties was more heterogeneous for shorter healing durations. After 7 weeks of healing, bone tissue in the bone chamber close to the implant surface was 12.3% denser than bone tissue further away. Bone tissue close to the chamber edge was 16.8% denser than in its center. These results suggest a bone spreading pathway along tissue maturation, which is confirmed by histology and consistent with contact osteogenesis phenomena.
- 21 July 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 84 (1) , 60-67
Multimodal characterization of the bone-implant interface using Raman spectroscopy and nanoindentation
Titanium implants are widely used in dental and orthopedic surgeries. Osseointegration phenomena lead to direct contact between bone tissue and the implant surface. The quality of the bone-implant interface (BII), resulting from the properties of newly formed bone, determines the implant stability. This study investigates the BII properties using a dedicated in vivo implant model consisting of a coin-shaped Ti-6Al-4V implant inserted in a rabbit femur for 10 weeks. A gap created below the implant was filled with newly formed bone tissue after healing. The properties of mature and newly formed bone tissues were compared using: i) Raman spectroscopy to assess the nanoscale compositional bone properties and ii) nanoindentation to quantify microscale elastic properties in site-matched regions. The mineral-to-matrix ratio, crystallinity (mineral size and lattice order), and the collagen cross-link ratio were significantly lower in newly formed bone tissue (e.g., a mineral-to-matrix ratio of 9.3 ± 0.5 for proline 853 cm-1) compared to mature bone (15.6 ± 1). Nanoindentation measurements gave Young's modulus of 12.8 ± 1.8 GPa for newly formed bone and 15.7 ± 2.3 GPa for mature bone. This multimodal and multiscale approach leads to a better understanding of osseointegration phenomena.
- 21 July 2020
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 84 (1) , 60-67
Multimodal characterization of the bone-implant interface using Raman spectroscopy and nanoindentation
Titanium implants are widely used in dental and orthopedic surgeries. Osseointegration phenomena lead to direct contact between bone tissue and the implant surface. The quality of the bone-implant interface (BII), resulting from the properties of newly formed bone, determines the implant stability. This study investigates the BII properties using a dedicated in vivo implant model consisting of a coin-shaped Ti-6Al-4V implant inserted in a rabbit femur for 10 weeks. A gap created below the implant was filled with newly formed bone tissue after healing. The properties of mature and newly formed bone tissues were compared using: i) Raman spectroscopy to assess the nanoscale compositional bone properties and ii) nanoindentation to quantify microscale elastic properties in site-matched regions. The mineral-to-matrix ratio, crystallinity (mineral size and lattice order), and the collagen cross-link ratio were significantly lower in newly formed bone tissue (e.g., a mineral-to-matrix ratio of 9.3 ± 0.5 for proline 853 cm-1) compared to mature bone (15.6 ± 1). Nanoindentation measurements gave Young's modulus of 12.8 ± 1.8 GPa for newly formed bone and 15.7 ± 2.3 GPa for mature bone. This multimodal and multiscale approach leads to a better understanding of osseointegration phenomena.