Hans Burkhard Dick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Hans Burkhard Dick has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Albert Joseph Augustin
Department of Ophthalmology, zeb business school, Steinbeis University, Baden-Baden, Germany
9 shared publications Norbert Pfeiffer
6 shared publicationsFrank Krummenauer
3 shared publicationsOliver Schwenn
Department of Ophthalmology, University of Mainz, Mainz, Germany
3 shared publicationsF. Krummenauer
Epidemiologie und Informatik der Universität Mainz
2 shared publicationsJ. Kuchenbecker
Universitäts-Augenklinik Magdeburg
2 shared publications
Latest Publications
- 1 March 2006
- Published by Elsevier in Ophthalmology Clinics of North America
- Vol. 19 (1) , 107-124
Single Optic Accommodative Intraocular Lenses
- 1 March 2006
- Published by Elsevier in Ophthalmology Clinics of North America
- Vol. 19 (1) , 107-124
Single Optic Accommodative Intraocular Lenses
- 1 October 2005
- Published by Springer Nature in Der Ophthalmologe
- Vol. 102 (10) , 987-992
Rotationsstabilität monofokaler Intraokularlinsen mit C-Haptik versus Z-Haptik nach Kataraktchirurgie
Ziel der Studie war der Vergleich der Rotationsstabilität von Intraokularlinsen (IOL) mit C-Haptiken und solchen mit Z-Haptiken. Prospektiv wurden 50 Kataraktpatienten zu gleichen Teilen auf die im Design äquivalenten IOL MS 612 S (C-Haptik) und MS 6120 (Z-Haptik) randomisiert. Klinische Endpunkte: IOL-Rotation nach einem Tag, einem Monat und 3 Monaten postoperativ. Zum Signifikanzvergleich der Gruppen wurde der unverbundene Wilcoxon-Test angewandt bei stetigen Endpunkten und für den binären primären Endpunkt der Studie („Rotation um mindestens 10°“) der exakte Fisher-Test. In der Gruppe der C-Haptik ergab sich eine IOL-Rotation im Median von 0° am 1. Tag sowie von 2° mit dem Uhrzeigersinn nach 1 und 3 Monaten. In der Gruppe der Z-Haptik war die IOL am 1. Tag sowie nach 1 und 3 Monaten im Median um 0° rotiert. Tendenziell zeigten sich in der Gruppe der C-Haptiken größere Ausreißer (Spannweite nach 3 Monaten 0–21° bei C-Haptiken und 0–15,5° bei Z-Haptiken). Die Haptik-Gruppen unterschieden sich zu keinem postoperativen Zeitpunkt statistisch signifikant. Drei Monate postoperativ waren 32% der C-Haptik-IOL und 16% der Z-Haptik-IOL um mindestens 10° rotiert (p=0,32). Die Rotationsrichtung war bei C-Haptik-IOL zu 59% im Uhrzeigersinn, bei Z-Haptik-IOL rotierten 40% in diese Richtung (p=0,33). Drei Monate postoperativ wiesen beide IOL eine gute Rotationsstabilität auf mit einer durchschnittlich nur minimalen Abweichung von der Implantationsachse. Es lässt sich im Langzeitverlauf eine tendenziell höhere Rotationsstabilität bei IOL mit Z-Haptik feststellen, die sich aber als nicht statistisch signifikant erwies. In der visuellen Rehabilitation zeigte sich nach 3 Monaten kein statistisch signifikanter Unterschied der Gruppen. The aim of the study was to compare the rotational stability of intraocular lenses (IOLs) with C-loop haptics and those with Z haptics. A total of 50 patients with cataracts were prospectively randomised in equal numbers using a design equivalent to IOL MS 612 S (C-loop haptic) and MS 6120 (Z haptic, both HumanOptics, Erlangen). Complete ophthalmological examinations were performed including assessment of the IOL rotation after 1 day, 1 month and 3 months postoperatively. The significances between the groups were evaluated using the Wilcoxon test. The Fisher exact test was used for the primary finding of the study (rotation of at least 10°). The IOL group with the C-loop haptics showed a median lens rotation of 0° on the first day and 2° clockwise after 1 month and 3 months. In the Z haptic group, there was no median rotation in the IOL group. Moreover, the range of IOL rotation of the C-loop haptics was broader (3 months postoperatively: maximum in the C-loop haptics: 21° with 15.5° in the Z haptics). There was no significant difference at any time. At 3 months postoperatively, 32% of the C-loop haptic IOL and 16% of the Z haptic IOL rotated at least 10° (P=0.32). In 59% of the IOL with C-loop haptics, the direction of the rotation was clockwise. This was 40% for the IOL with Z haptics (P=0.33). At 3 months postoperatively, both IOLs demonstrated good rotational stability with a low mean deviation from the target axis. IOLs with Z haptics showed a tendency to greater rotational stability than C-loop haptics but without any significant difference. There was no significant difference in visual rehabilitation.
- 1 October 2005
- Published by Springer Nature in Der Ophthalmologe
- Vol. 102 (10) , 987-992
Rotationsstabilität monofokaler Intraokularlinsen mit C-Haptik versus Z-Haptik nach Kataraktchirurgie
Ziel der Studie war der Vergleich der Rotationsstabilität von Intraokularlinsen (IOL) mit C-Haptiken und solchen mit Z-Haptiken. Prospektiv wurden 50 Kataraktpatienten zu gleichen Teilen auf die im Design äquivalenten IOL MS 612 S (C-Haptik) und MS 6120 (Z-Haptik) randomisiert. Klinische Endpunkte: IOL-Rotation nach einem Tag, einem Monat und 3 Monaten postoperativ. Zum Signifikanzvergleich der Gruppen wurde der unverbundene Wilcoxon-Test angewandt bei stetigen Endpunkten und für den binären primären Endpunkt der Studie („Rotation um mindestens 10°“) der exakte Fisher-Test. In der Gruppe der C-Haptik ergab sich eine IOL-Rotation im Median von 0° am 1. Tag sowie von 2° mit dem Uhrzeigersinn nach 1 und 3 Monaten. In der Gruppe der Z-Haptik war die IOL am 1. Tag sowie nach 1 und 3 Monaten im Median um 0° rotiert. Tendenziell zeigten sich in der Gruppe der C-Haptiken größere Ausreißer (Spannweite nach 3 Monaten 0–21° bei C-Haptiken und 0–15,5° bei Z-Haptiken). Die Haptik-Gruppen unterschieden sich zu keinem postoperativen Zeitpunkt statistisch signifikant. Drei Monate postoperativ waren 32% der C-Haptik-IOL und 16% der Z-Haptik-IOL um mindestens 10° rotiert (p=0,32). Die Rotationsrichtung war bei C-Haptik-IOL zu 59% im Uhrzeigersinn, bei Z-Haptik-IOL rotierten 40% in diese Richtung (p=0,33). Drei Monate postoperativ wiesen beide IOL eine gute Rotationsstabilität auf mit einer durchschnittlich nur minimalen Abweichung von der Implantationsachse. Es lässt sich im Langzeitverlauf eine tendenziell höhere Rotationsstabilität bei IOL mit Z-Haptik feststellen, die sich aber als nicht statistisch signifikant erwies. In der visuellen Rehabilitation zeigte sich nach 3 Monaten kein statistisch signifikanter Unterschied der Gruppen. The aim of the study was to compare the rotational stability of intraocular lenses (IOLs) with C-loop haptics and those with Z haptics. A total of 50 patients with cataracts were prospectively randomised in equal numbers using a design equivalent to IOL MS 612 S (C-loop haptic) and MS 6120 (Z haptic, both HumanOptics, Erlangen). Complete ophthalmological examinations were performed including assessment of the IOL rotation after 1 day, 1 month and 3 months postoperatively. The significances between the groups were evaluated using the Wilcoxon test. The Fisher exact test was used for the primary finding of the study (rotation of at least 10°). The IOL group with the C-loop haptics showed a median lens rotation of 0° on the first day and 2° clockwise after 1 month and 3 months. In the Z haptic group, there was no median rotation in the IOL group. Moreover, the range of IOL rotation of the C-loop haptics was broader (3 months postoperatively: maximum in the C-loop haptics: 21° with 15.5° in the Z haptics). There was no significant difference at any time. At 3 months postoperatively, 32% of the C-loop haptic IOL and 16% of the Z haptic IOL rotated at least 10° (P=0.32). In 59% of the IOL with C-loop haptics, the direction of the rotation was clockwise. This was 40% for the IOL with Z haptics (P=0.33). At 3 months postoperatively, both IOLs demonstrated good rotational stability with a low mean deviation from the target axis. IOLs with Z haptics showed a tendency to greater rotational stability than C-loop haptics but without any significant difference. There was no significant difference in visual rehabilitation.
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (3) , 467-471
Closed foldable capsular rings
A new foldable capsular tension and bending ring system with a sharp-edged design is described. The closed foldable capsular rings (CFCR) consist of 8 hydrophobic and 8 hydrophilic ring segments. The CFCRs have a 9.2 mm minimum overall diameter. The CFCRs were inserted using various cartridge systems or a two-folded technique with a forceps. The CFCRs were implanted after phacoemulsification through a small (1.6 to 3.2 mm) incision in 104 human adult eyes without intraoperative complications. No postoperative complications such as capsule folds or inward bending were observed over a 6-month follow-up. Posterior capsule opacification was minimal or absent in all eyes.
- 1 March 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (3) , 467-471
Closed foldable capsular rings
A new foldable capsular tension and bending ring system with a sharp-edged design is described. The closed foldable capsular rings (CFCR) consist of 8 hydrophobic and 8 hydrophilic ring segments. The CFCRs have a 9.2 mm minimum overall diameter. The CFCRs were inserted using various cartridge systems or a two-folded technique with a forceps. The CFCRs were implanted after phacoemulsification through a small (1.6 to 3.2 mm) incision in 104 human adult eyes without intraoperative complications. No postoperative complications such as capsule folds or inward bending were observed over a 6-month follow-up. Posterior capsule opacification was minimal or absent in all eyes.
- 1 February 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (2) , 302-307
Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens
To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindividual comparisons were made between preoperative and postoperative pupil sizes. The relationship between implanted IOL power and postoperative pupil width in each group was studied to determine whether lens magnification could lead to misinterpretation of the results. The difference between horizontal and vertical postoperative pupil diameters was assessed in eyes with horizontally aligned IOLs to determine the potential mechanical effect of the TPIOL on pupil size. The mean scotopic pupil diameter decreased significantly from 4.7 mm (range 3.0 to 6.0 mm) preoperatively to 3.6 mm (range 2.0 to 5.0 mm) postoperatively in myopic eyes and from 5.0 mm (range 4.0 to 6.0 mm) to 4.0 mm (range 2.0 to 5.0 mm) in hyperopic eyes. No significant correlation between the power of the TPIOL and the postoperative pupil size diameter was found, confirming that the IOL did not distort measurements of pupil size. Comparing horizontal and vertical pupil diameters under medical mydriasis revealed reduced pupil size in the axis of enclavation. The scotopic pupil diameter decreased by a mean of 1.1 mm in myopic eyes and 1.0 mm in hyperopic eyes after implantation of the iris-supported TPIOL. Postoperative pupil size was not related to IOL power, patients' emotional states, or other factors. The slightly smaller pupil diameter in the axis of enclavation suggests that this fixation method restricts pupil size under scotopic conditions, which could reduce the incidence of postoperative photic phenomena.
- 1 February 2005
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (2) , 302-307
Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens
To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindividual comparisons were made between preoperative and postoperative pupil sizes. The relationship between implanted IOL power and postoperative pupil width in each group was studied to determine whether lens magnification could lead to misinterpretation of the results. The difference between horizontal and vertical postoperative pupil diameters was assessed in eyes with horizontally aligned IOLs to determine the potential mechanical effect of the TPIOL on pupil size. The mean scotopic pupil diameter decreased significantly from 4.7 mm (range 3.0 to 6.0 mm) preoperatively to 3.6 mm (range 2.0 to 5.0 mm) postoperatively in myopic eyes and from 5.0 mm (range 4.0 to 6.0 mm) to 4.0 mm (range 2.0 to 5.0 mm) in hyperopic eyes. No significant correlation between the power of the TPIOL and the postoperative pupil size diameter was found, confirming that the IOL did not distort measurements of pupil size. Comparing horizontal and vertical pupil diameters under medical mydriasis revealed reduced pupil size in the axis of enclavation. The scotopic pupil diameter decreased by a mean of 1.1 mm in myopic eyes and 1.0 mm in hyperopic eyes after implantation of the iris-supported TPIOL. Postoperative pupil size was not related to IOL power, patients' emotional states, or other factors. The slightly smaller pupil diameter in the axis of enclavation suggests that this fixation method restricts pupil size under scotopic conditions, which could reduce the incidence of postoperative photic phenomena.
- 1 February 2005
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 16 (1) , 8-26
Accommodative intraocular lenses: current status
The possibility of using a monofocal IOL with accommodative ability allows refractive cataract surgery with a clearly decreased potential of photic phenomena. Three IOLs of different designs and materials have demonstrated accommodative ability, but the degree of accommodative amplitude has been reported to different extents and variabilities. The plate-haptic CrystaLens has a hinged design that might permit forward movement of the optic as a result of pressure changes in the vitreous cavity. The 1CU has modified haptics that bend in the bag as the lens capsule contracts, which are supposed to cause anterior displacement of the lens optic. With the dual-optic one-piece Synchrony, springlike haptics separate a high-plus anterior lens from a posterior minus lens. With accommodative effort, the capsular bag expands and the springs express kinetic energy, which might allow the optics to separate as the anterior lens moves forward. This article seeks to clarify and distinguish the concepts of true accommodation and pseudo accommodation. Current designs of accommodative IOLs are supposed to work by the focus-shift principle to allow true pseudophakic accommodation. Studies that biometrically assessed optic shift found no or only low amplitudes of forward movement. The amount of forward movement, if present, was highly variable between patients. To date, most studies present psychophysical data for the proof of concept, which alone seems insufficient. Capsule bag performance and posterior capsule opacification with accommodative IOLs seem worse than those with standard intraocular lenses. The potential clinical benefits of accommodative IOL technology for both cataract patients and refractive patients may place accommodative IOLs in a competitive position with multifocal IOL technology.
- 1 February 2005
- Published by Wolters Kluwer Health in Current Opinion in Ophthalmology
- Vol. 16 (1) , 8-26
Accommodative intraocular lenses: current status
The possibility of using a monofocal IOL with accommodative ability allows refractive cataract surgery with a clearly decreased potential of photic phenomena. Three IOLs of different designs and materials have demonstrated accommodative ability, but the degree of accommodative amplitude has been reported to different extents and variabilities. The plate-haptic CrystaLens has a hinged design that might permit forward movement of the optic as a result of pressure changes in the vitreous cavity. The 1CU has modified haptics that bend in the bag as the lens capsule contracts, which are supposed to cause anterior displacement of the lens optic. With the dual-optic one-piece Synchrony, springlike haptics separate a high-plus anterior lens from a posterior minus lens. With accommodative effort, the capsular bag expands and the springs express kinetic energy, which might allow the optics to separate as the anterior lens moves forward. This article seeks to clarify and distinguish the concepts of true accommodation and pseudo accommodation. Current designs of accommodative IOLs are supposed to work by the focus-shift principle to allow true pseudophakic accommodation. Studies that biometrically assessed optic shift found no or only low amplitudes of forward movement. The amount of forward movement, if present, was highly variable between patients. To date, most studies present psychophysical data for the proof of concept, which alone seems insufficient. Capsule bag performance and posterior capsule opacification with accommodative IOLs seem worse than those with standard intraocular lenses. The potential clinical benefits of accommodative IOL technology for both cataract patients and refractive patients may place accommodative IOLs in a competitive position with multifocal IOL technology.
- 1 March 2004
- Published by Springer Nature in Der Ophthalmologe
- Vol. 101 (3) , 232-245
Phake Intraokularlinsen
- 1 March 2004
- Published by Springer Nature in Der Ophthalmologe
- Vol. 101 (3) , 232-245
Phake Intraokularlinsen
- 1 March 2003
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 13 (2) , 176-184
Endotoxins in Ophthalmic Viscosurgical Devices
Purpose: To measure the endotoxin concentration (EC) of 25 commercially available, hyaluronic acid- and hydroxypropylmethylcellulose-based (HPMC) ophthalmic viscosurgical devices (OVDs). Methods: The in vitro Limulus amebocyte lysate (LAL) assay, which indicates the presence of endotoxins originating from gram-negative bacteria, was used to determine the EC. The procedure was performed according to the European Pharmacopoeia/USP. EC including duplicate determinations, negative controls, dilution series with control standard endotoxin, dilution series with sample extract and positive sample control. Results: 16 OVDs (Amvisc®, Amvisc® Plus, Biolon®, Coatel®, Healon®, Healon® GV, Healon®5, HPMC Ophtal® L, Microvisc®, Microvisc® Plus, Ocucoat®, Provisc®, Rayvisc®, Viscoat®, Visco Shield® 2%, Visko® 1.4%) had an EC under 1.2 endotoxin units/mL, five (Adatocel®, HPMC Ophtal® H, LA Gel®, Viscorneal®, Viscorneal® Plus) had an EC ≥ 1.2 and ≤ 24 EU/ml, and four (Biocorneal®, Dispasan® also named Ophthalin, Dispasan® Plus, Visko® 1%) had an EC of > 24 EU/ml. Discussion: To avoid viscoelastic-related inflammatory or immunological reactions, the use of pure OVDs is recommended, especially for surgical procedures with an inherent possibility of leaving viscoelastic remnants in the eye (e.g., cataract surgery, viscocanalostomy or penetrating keratoplasty).
- 1 March 2003
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 13 (2) , 176-184
Endotoxins in Ophthalmic Viscosurgical Devices
Purpose: To measure the endotoxin concentration (EC) of 25 commercially available, hyaluronic acid- and hydroxypropylmethylcellulose-based (HPMC) ophthalmic viscosurgical devices (OVDs). Methods: The in vitro Limulus amebocyte lysate (LAL) assay, which indicates the presence of endotoxins originating from gram-negative bacteria, was used to determine the EC. The procedure was performed according to the European Pharmacopoeia/USP. EC including duplicate determinations, negative controls, dilution series with control standard endotoxin, dilution series with sample extract and positive sample control. Results: 16 OVDs (Amvisc®, Amvisc® Plus, Biolon®, Coatel®, Healon®, Healon® GV, Healon®5, HPMC Ophtal® L, Microvisc®, Microvisc® Plus, Ocucoat®, Provisc®, Rayvisc®, Viscoat®, Visco Shield® 2%, Visko® 1.4%) had an EC under 1.2 endotoxin units/mL, five (Adatocel®, HPMC Ophtal® H, LA Gel®, Viscorneal®, Viscorneal® Plus) had an EC ≥ 1.2 and ≤ 24 EU/ml, and four (Biocorneal®, Dispasan® also named Ophthalin, Dispasan® Plus, Visko® 1%) had an EC of > 24 EU/ml. Discussion: To avoid viscoelastic-related inflammatory or immunological reactions, the use of pure OVDs is recommended, especially for surgical procedures with an inherent possibility of leaving viscoelastic remnants in the eye (e.g., cataract surgery, viscocanalostomy or penetrating keratoplasty).
- 1 January 2003
- Published by Elsevier in Ophthalmology
- Vol. 110 (1) , 150-162
Toric phakic intraocular lens
- 1 January 2003
- Published by Elsevier in Ophthalmology
- Vol. 110 (1) , 150-162
Toric phakic intraocular lens
- 1 November 2002
- Published by Springer Nature in Der Ophthalmologe
- Vol. 99 (11) , 825-834
Dynamische Aberrometrie während der Akkommodation phaker Augen sowie Augen mit potenziell akkommodativer Intraokularlinse
Eine objektive Messung des Akkommodationseffektes ist nach Implantation potenziell akkommodativer Intraokularlinsen (IOL) – auch aufgrund methodischer Probleme – sehr schwierig. Unter anderem wurden hierzu Messungen der Änderung der Vorderkammertiefe mittels Laserinterferenzbiometrie durchgeführt. Alle bisherigen Untersuchungen konnten bislang nicht eindeutig klären, ob und in welchem Ausmaß potenziell akkommodative IOL überhaupt funktionieren. Mittels Wellenfrontanalyse wurde das dynamische Verhalten potenziell akkommodativer IOL vermessen. Die Messungen wurden mit einem Hartmann-Shack-Aberrometer durchgeführt. Als Besonderheit waren sequenzielle dynamische Wellenfrontmessungen mit einer Frequenz von ca. 7 Hz möglich. An 43 Augen wurde 6–8 Wochen nach Implantation potenziell akkommodativer IOL (CrystaLens AT-45, C&C Vision; 1CU, Humanoptics) eine dynamische Wellenfrontanalyse durchgeführt. Über einen Zeitraum von 30 s erfolgten insgesamt 200 Einzelmessungen. Die Patienten fokussierten 10 s auf ein Objekt in der Ferne, dann für 10 s auf ein Objekt in der Nähe und danach wieder auf das Fernobjekt. Zum Vergleich wurden auch Messungen an gesunden Augen junger Patienten sowie an Augen mit implantierter Standardintraokularlinse vorgenommen. Der dynamische Verlauf der Aberrationen niedriger Ordnung (Defokus, Astigmatismus) sowie der sphärischen Aberration 4. Ordnung wurde analysiert. Die dynamische Wellenfrontanalyse ermöglicht eine objektive und untersucherunabhängige Messung der Akkommodation bei phaken wie auch pseudophaken Augen. Die dynamische Aberrometrie eignet sich, um den Effekt eines refraktiv-chirurgischen Eingriffes zur Korrektur der Presbyopie objektiv zu quantifizieren. Es ist wünschenswert, dass diese Technologie zusätzlich zu den gängigen psycho-physischen Untersuchungsmethoden zur Evaluation der verschiedenen Operationsverfahren zur Presyopiekorrektur eingesetzt wird, um eine objektive Beurteilung der Effizienz des jeweiligen Verfahrens zu erlangen. Since the introduction of potentially accommodative intraocular lenses (IOLs), it was hard to perform an objective evaluation of the accommodative amplitude in pseudophakic eyes. Laser interferometric measurements were performed to evaluate anterior chamber depth changes, which provides information on the functionality of potentially accommodative IOLs. By means of wavefront analysis, the dynamic behaviour of potentially accommodative IOLs can be determined. All measurements in this study were performed using a Hartmann-Shack aberrometer at a frequency of 7 Hz. Six to 8 weeks after implantation of potentially accommodative IOLs (CrystaLens AT-45, C&C Vision, 1CU, Humanoptics), 43 eyes were investigated using this dynamic wavefront analysis. Patients focussed at a distance target for 10 s, followed by focussing at a near target for 10 s and then again at a distance target for a further 10 s. During these 30 s, a total of 200 single measurements were performed. The same measurements were also conducted in healthy eyes of young persons as well as in eyes after implantation of standard IOLs for comparative purposes. The dynamic course of changes in low-order aberrations (defocus, astigmatism) as well as high-order (e.g., fourth-order spherical aberration) were analysed. Dynamic wavefront analysis allowed objective and observer-independent measurement of changes in accommodation in phakic and pseudophakic eyes. Dynamic aberrometry is capable of objectively quantifying the effect of any surgical option for the treatment of presbyopia. We recommend use of this technology in addition to the common psychophysical examinations to attain objective information on the efficacy of the treatment modality used.
- 1 November 2002
- Published by Springer Nature in Der Ophthalmologe
- Vol. 99 (11) , 825-834
Dynamische Aberrometrie während der Akkommodation phaker Augen sowie Augen mit potenziell akkommodativer Intraokularlinse
Eine objektive Messung des Akkommodationseffektes ist nach Implantation potenziell akkommodativer Intraokularlinsen (IOL) – auch aufgrund methodischer Probleme – sehr schwierig. Unter anderem wurden hierzu Messungen der Änderung der Vorderkammertiefe mittels Laserinterferenzbiometrie durchgeführt. Alle bisherigen Untersuchungen konnten bislang nicht eindeutig klären, ob und in welchem Ausmaß potenziell akkommodative IOL überhaupt funktionieren. Mittels Wellenfrontanalyse wurde das dynamische Verhalten potenziell akkommodativer IOL vermessen. Die Messungen wurden mit einem Hartmann-Shack-Aberrometer durchgeführt. Als Besonderheit waren sequenzielle dynamische Wellenfrontmessungen mit einer Frequenz von ca. 7 Hz möglich. An 43 Augen wurde 6–8 Wochen nach Implantation potenziell akkommodativer IOL (CrystaLens AT-45, C&C Vision; 1CU, Humanoptics) eine dynamische Wellenfrontanalyse durchgeführt. Über einen Zeitraum von 30 s erfolgten insgesamt 200 Einzelmessungen. Die Patienten fokussierten 10 s auf ein Objekt in der Ferne, dann für 10 s auf ein Objekt in der Nähe und danach wieder auf das Fernobjekt. Zum Vergleich wurden auch Messungen an gesunden Augen junger Patienten sowie an Augen mit implantierter Standardintraokularlinse vorgenommen. Der dynamische Verlauf der Aberrationen niedriger Ordnung (Defokus, Astigmatismus) sowie der sphärischen Aberration 4. Ordnung wurde analysiert. Die dynamische Wellenfrontanalyse ermöglicht eine objektive und untersucherunabhängige Messung der Akkommodation bei phaken wie auch pseudophaken Augen. Die dynamische Aberrometrie eignet sich, um den Effekt eines refraktiv-chirurgischen Eingriffes zur Korrektur der Presbyopie objektiv zu quantifizieren. Es ist wünschenswert, dass diese Technologie zusätzlich zu den gängigen psycho-physischen Untersuchungsmethoden zur Evaluation der verschiedenen Operationsverfahren zur Presyopiekorrektur eingesetzt wird, um eine objektive Beurteilung der Effizienz des jeweiligen Verfahrens zu erlangen. Since the introduction of potentially accommodative intraocular lenses (IOLs), it was hard to perform an objective evaluation of the accommodative amplitude in pseudophakic eyes. Laser interferometric measurements were performed to evaluate anterior chamber depth changes, which provides information on the functionality of potentially accommodative IOLs. By means of wavefront analysis, the dynamic behaviour of potentially accommodative IOLs can be determined. All measurements in this study were performed using a Hartmann-Shack aberrometer at a frequency of 7 Hz. Six to 8 weeks after implantation of potentially accommodative IOLs (CrystaLens AT-45, C&C Vision, 1CU, Humanoptics), 43 eyes were investigated using this dynamic wavefront analysis. Patients focussed at a distance target for 10 s, followed by focussing at a near target for 10 s and then again at a distance target for a further 10 s. During these 30 s, a total of 200 single measurements were performed. The same measurements were also conducted in healthy eyes of young persons as well as in eyes after implantation of standard IOLs for comparative purposes. The dynamic course of changes in low-order aberrations (defocus, astigmatism) as well as high-order (e.g., fourth-order spherical aberration) were analysed. Dynamic wavefront analysis allowed objective and observer-independent measurement of changes in accommodation in phakic and pseudophakic eyes. Dynamic aberrometry is capable of objectively quantifying the effect of any surgical option for the treatment of presbyopia. We recommend use of this technology in addition to the common psychophysical examinations to attain objective information on the efficacy of the treatment modality used.
- 1 September 2002
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 18 (5) , 509-518
Refractive Lens Exchange With an Array Multifocal Intraocular Lens
PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=26; hyperopia, average preoperative spherical equivalent refraction +3.04 ± 1.04 D). Follow-up was 6 months in ail eyes. Postoperatively, all eyes of both groups were within ±1.00 D of target refraction. No eye in group A and three eyes in group B sustained a loss of one line of BSCVA, Forty-seven eyes (94%) remained unchanged or gained one or more lines of their preoperative BSCVA In all eyes, postoperative UCVA was 20/40 or better. When compared to preoperative, uncorrected near visual acuity improved (statistically significant). All patients achieved uncorrected binocular visual acuity of 20/30 and J4 or better. Patient satisfaction was extremely high; no intraor postoperative complications were reported. CONCLUSION: Six-month results of implantation of the AMO Array multifocal IOL for refractive lens exchange demonstrated safety, efficacy, and predictability in correcting high ametropia and significant improvement of uncorrected near and distance visual acuity. [J Refract Surg 2002;18:509-518]
- 1 September 2002
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 18 (5) , 509-518
Refractive Lens Exchange With an Array Multifocal Intraocular Lens
PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=26; hyperopia, average preoperative spherical equivalent refraction +3.04 ± 1.04 D). Follow-up was 6 months in ail eyes. Postoperatively, all eyes of both groups were within ±1.00 D of target refraction. No eye in group A and three eyes in group B sustained a loss of one line of BSCVA, Forty-seven eyes (94%) remained unchanged or gained one or more lines of their preoperative BSCVA In all eyes, postoperative UCVA was 20/40 or better. When compared to preoperative, uncorrected near visual acuity improved (statistically significant). All patients achieved uncorrected binocular visual acuity of 20/30 and J4 or better. Patient satisfaction was extremely high; no intraor postoperative complications were reported. CONCLUSION: Six-month results of implantation of the AMO Array multifocal IOL for refractive lens exchange demonstrated safety, efficacy, and predictability in correcting high ametropia and significant improvement of uncorrected near and distance visual acuity. [J Refract Surg 2002;18:509-518]